Search PubMed⌕ Search

Biomedical subjects

Alba Macià

Publications and source records attributed to Alba Macià.

5 recordsLinked to original sources

Different sample stacking strategies to analyse some nonsteroidal anti-inflammatory drugs by micellar electrokinetic capillary chromatography in mineral waters.

Three on-column preconcentration techniques were compared to analyse a group of nonsteroidal anti-inflammatory drugs (NSAIDs) using micellar electrokinetic capillary chromatography (MEKC) under pH-suppressed electroosmotic flow (EOF) in water samples. The analysed drugs were ibuprofen, fenoprofen, naproxen, ketoprofen, and diclofenac sodium. The micellar background electrolyte (BGE) solution was formed by 75 mM sodium dodecyl sulfate (SDS), 40% (v/v) acetonitrile, and 25 mM sodium phosphate at pH 2.5. When this BGE solution was used the applied voltage was reversed, -10 kV, and the drugs were separated within 20 min. The on-column preconcentration modes, characterised all of them for the sample matrix removal out of the capillary by itself under a reverse potential at the same time as the EOF was reduced, were stacking with reverse migrating micelles (SRMM), stacking with reverse migrating micelles-anion selective exhaustive injection (SRMM-ASEI), and field-enhanced sample injection with reverse migrating micelles (FESI-RMM). The sensitivity was improved up to 154-, 263-, and 63-fold, respectively when it was calculated through the peaks height. The optimised methods were validated with spiked mineral water by combining off-line solid-phase extraction (SPE) and the proposed on-line sample stacking strategies. The detection limits (LODs) of NSAIDs in mineral water were at ng/L levels.

Anti-Inflammatory Agents, Non-Steroidal↗

Separation and on-column preconcentration of some nonsteroidal anti-inflammatory drugs by microemulsion electrokinetic capillary chromatography using high-speed separations.

Various strategies have been investigated for separating a group of nonsteroidal anti-inflammatory drugs (NSAIDs) by microemulsion electrokinetic capillary chromatography (MEEKC) using high-speed separations. The parameters that of affect the separation, such as the nature of the oil droplet and the buffer, and the surfactant concentration have been studied. In addition, several organic solvents were used to decrease the retention of the analytes in the oil droplet phase and to improve the resolution of the NSAIDs. The optimum microemulsion background electrolyte (BGE) solution made of 0.8% w/w ethyl acetate, 6.6% w/w butan-1-ol, 6.0% w/w acetonitrile, 1.0% w/w sodium dodecyl sulfate (SDS), and 85.6% w/w of 10 mM sodium tetraborate at pH 9.2 resolved the drugs within 8 min. The short-end injection procedure is an alternative for reducing the analysis time. When this procedure was used, the microemulsion BGE solution consisted of 0.8% w/w ethyl acetate, 6.6% w/w butan-1-ol, 17.0% w/w methanol, 1.0% w/w SDS, and 74.6% w/w of 10 mM sodium tetraborate, pH 9.2, and the NSAIDs were separated within 3 min. The reversed electrode polarity stacking mode (REPSM) technique was applied to the on-line concentration of the NSAIDs. In this technique, the sample matrix was pumped out of the capillary using a polarity-switching step. When this technique was applied, the sensitivity was enhanced up to 40-fold and the limits of detection (LODs) were in the low microg.L(-1) levels.

2-Propanol↗

Application of capillary electrophoresis with different sample stacking strategies for the determination of a group of nonsteroidal anti-inflammatory drugs in the low microg x L(-1) concentration range.

Several on-column sample preconcentration modes--large-volume sample stacking using the EOF pump (LVSEP), LVSEP with anion-selective exhaustive injection (LVSEP-ASEI) and field-amplified sample injection with sample matrix removal using the electroosmotic flow (EOF) pump (FAEP)--were used to analyze some nonsteroidal anti-inflammatory drugs (NSAIDs) by capillary electrophoresis, and then compared. Methanol was the background electrolyte solvent to suppress the EOF. The effect of the type and length of the solvent plug, and the sample injection time were investigated in FAEP to determine the conditions that provided the best response. LVSEP, LVSEP-ASEI, and FAEP improved the sensitivity of the peak area by 100-, 1200-, and 1800-fold, respectively. The methodology developed, in combination with solid-phase extraction (SPE), was applied to the analysis of water samples.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of some acidic drugs in surface and sewage treatment plant waters by capillary electrophoresis-electrospray ionization-mass spectrometry.

We describe an analytical method involving solid-phase extraction (SPE) and capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) for determining some pharmaceutical compounds - naproxen, clofibric acid and bezafibrate - in real water samples. The electrospray parameters were optimized to maximize sensitivity. When a mixed aqueous-organic solvent and CZE-ESI-MS were used to analyze these drugs in water samples, the capillary was coated with hexadimethrin bromide (HDB) to permanently reverse the EOF. The method was developed from off-line SPE-CZE-MS and was validated with surface water. The detection limits were 100 ng.L(-1) for all analytes. The method was applied to analyze water samples from the influent and effluent of a sewage treatment plant. A liquid-liquid extraction step was required before SPE, and the compounds studied were found, some of them between detection and quantification limits.

Acids↗

Improving sensitivity by large-volume sample stacking using the electroosmotic flow pump to analyze some nonsteroidal anti-inflammatory drugs by capillary electrophoresis in water samples.

Large-volume sample stacking using the electroosmotic flow (EOF) pump (LVSEP) has been used to analyze some nonsteroidal anti-inflammatory drugs (NSAIDs) in water samples. With methanol as the run buffer solvent to suppress the EOF, sensitivity was enhanced by 80-100-fold. The sample for the analysis of real water sample was pretreated by solid-phase extraction (SPE). When the method was based on off-line SPE-LVSEP-CE, sensitivity improved by as much as 1000 times.

Anti-Inflammatory Agents, Non-Steroidal↗