Development of a collimator blurring compensation method using fine angular sampling projection data in SPECT.

Due to the collimator aperture, spatial resolution of SPECT data varies with source-to-detector distance. Since the radius of detector rotation is bigger when scanning larger patients, spatial resolution is degraded in these cases. Emitted gamma rays travel not only along the central axis of the collimator hole but also off-axis due to the collimator aperture. However, an off-axis ray at one angle would be a central-axis ray at another angle; therefore, raw projection data at one angle can be thought of as an ensemble of central-axis rays collected from a small arc equal to the collimator aperture. Thus, fine angular sampling can compensate for collimator blurring. By using a sampling pitch of less than half the collimator aperture angle, compensation was performed by subtracting the weighted sum of the projection data from the raw projection data. Collimator geometry and detector rotation radius determined the weighting function. Cylindrical phantom with four different-sized rods and torso phantom for Tl-201 cardiac SPECT simulation were used for evaluation. Aperture angle of the collimator was 7 degrees. Projection sampling pitch was 2 degrees. In both phantom studies, the proposed method showed improvement in contrast and reduction of partial volume effect, thereby indicating that the proposed method can compensate adequately for image blurring caused by the collimator aperture.

Artifacts↗

Reconstitution of Saccharomyces cerevisiae prereplicative complex assembly in vitro.

The assembly of the prereplicative complex (pre-RC) at the origin of replication in eukaryotes is a highly regulated and highly conserved process that plays a critical role in preventing multiple rounds of DNA replication per cell division cycle. This study analyzes the molecular dynamics of the assembly of Saccharomyces cerevisiae pre-RC in vitro using ARS1 plasmid DNA and yeast whole cell extracts. In addition, pre-RC assembly was reconstituted in vitro using ARS1 DNA and purified origin-recognition complex (ORC), Cdc6p and Cdt1p-Mcm2-7p. The results reveal sequential recruitment of ORC, Cdc6p, Cdt1p and Mcm2-7p on to ARS1 DNA. When Mcm2-7p is maximally loaded, Cdc6p and Cdt1p are released, suggesting that these two proteins are co-ordinately regulated during pre-RC assembly. In extracts from sid2-21 mutant cells that are deficient in CDT1, ORC and Cdc6p bind to ARS1 but Cdt1p and Mcm2-7p do not. However, Mcm2-7p does bind in the presence of exogenous Cdt1p or Cdt1p-Mcm2-7p complex. Cdt1p-Mcm2-7p complex, which was purified from G1-, early S or G2/M-arrested cells, exhibits structure-specific DNA binding, interacting only with bubble- or Y-shape-DNA, but the biological significance of this observation is not yet known.

Cell Cycle Proteins↗

Oral and oropharyngeal squamous cell carcinomas expressing CCR7 have poor prognoses.

OBJECTIVE AND METHODS: Tumor cell migration and metastasis have many similarities with leukocyte trafficking regulated by chemokines and their receptors. In this study, we investigated the expression of CC chemokine receptor 7 (CCR7) in oral and oropharyngeal squamous cell carcinomas (SCCs) using an immunohistochemical approach. RESULTS: Among 90 cases of oral and oropharyngeal SCCs, 54 cases (60%) were positive for CCR7. The CCR7-positive group had a significantly lower incidence of being disease-free and an overall lower survival rate than the CCR7-negative group (p<0.01 and p<0.01, respectively). Among the 35 patients who died of cancer, 28 patients (80%) were positive for CCR7. The expression of CCR7 was significantly associated with five clinical factors. SCCs expressing CCR7 tend to have large, lymph node metastases, progressive stages, local recurrences and cancer death. The CCR7 expression of metastatic SCCs in draining lymph nodes was detected, and the staining score of CCR7 between primary SCCs and metastatic SCCs were significantly correlated (p<0.01). CONCLUSIONS: The investigation of CCR7 expression in oral and oropharyngeal SCCs may be useful to predict patients prognoses.

Carcinoma, Squamous Cell↗

Optimum energy window setting on Hg-201 x-rays photopeak for effective Tl-201 imaging.

For more effective Tl-201 imaging, the location and width of the energy window set on the Hg-201 x-rays photopeak was investigated using Monte Carlo simulation and phantom experiments. We calculated energy spectra and investigated the amount of primary and scattered photons within various energy windows set on the x-rays photopeak. The energy resolution (ER) at 71 keV (the peak of the x-rays photopeak) was changed to 10%, 12%, 14% and 16%. The relationships between the energy window and the primary counts rate or the scatter fraction (= scattered counts/primary counts, SF) were obtained. By compromise between the primary counts rate and the SF for ER = 12%, the optimum energy window was determined as a wider off-peak window, 77 keV +/- 14.3% (66-88 keV). This off-peak window increased the primary counts rate by 12.5% and decreased the SF by -17% as compared with the conventional on-peak energy window (71 keV +/- 10%, 64-78 keV). When this off-peak widow acquisition was compared with the conventional on-peak window one on a gamma camera, planar and SPECT images using the off-peak widow clearly showed superior results qualitatively and quantitatively.

Algorithms↗

Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system.

OBJECTIVE: Attenuation artifacts adversely affect the diagnostic accuracy of myocardial perfusion imaging. We assessed the clinical usefulness of X-ray CT based attenuation correction (AC) in patients undergoing myocardial perfusion imaging by comparing their myocardial AC- and non-corrected (NC) SPECT images with the coronary angiography (CAG). METHODS: We retrospectively reviewed the myocardial SPECT images of 30 patients (18 men, 12 women; mean age 68 years). Thirteen of 30 patients with coronary artery disease (CAD) and 17 without CAD were confirmed by CAG. They underwent sequential CT and myocardial SPECT imaging with thallium-201 (111 MBq) under an exercise or pharmacological stress protocol using our combined SPECT/ CT system. Two readers reviewed the myocardial SPECT images for the presence of CAD on a 4-point scale where 1 = normal, 2 = probably normal, 3 = probably abnormal, and 4 = abnormal. Two reading sessions were held. First, non-corrected (NC)-SPECT and second, AC-SPECT images using X-ray CT images were interpreted. Interobserver variability was assessed with kappa statistics. Diagnostic performance (accuracy) of coronary arterial stenosis was compared between AC- and NC-images. RESULTS: Interobserver agreement for visual assessment was substantial or almost perfect. For AC-images, the observer consensus for analysis was 0.84 for the LAD-, 0.87 for the LCX-, and 0.71 for the RCA-territory. For NC-images, it was 0.91, 0.71, and 0.78. AC resulted in statistically significant improvements in overall diagnostic accuracy (sensitivity/ specificity/accuracy = 76%/93%/89%, 67%/86%/81%, respectively, for AC- and NC-images). CONCLUSIONS: Because of an increase in the specificity, diagnostic accuracy was significantly increased on AC-images. These preliminary data suggest that X-ray CT based AC in myocardial SPECT imaging has the potential to develop into a reliable clinical technique.

Aged↗

Attenuation correction using asymmetric fanbeam transmission CT on two-head SPECT system.

For transmission computed tomography (TCT) systems using a centered transmission source with a fan-beam collimator, the transmission projection data are truncated. To achieve sufficiently large imaging field of view (FOV), we have designed the combination of an asymmetric fan-beam (AsF) collimator and a small uncollimated sheet-source for TCT, and implemented AsF sampling on a two-head SPECT system. The purpose of this study is to evaluate the feasibility of our TCT method for quantitative emission computed tomography (ECT) in clinical application. Sequential Tc-99m transmission and Tl-201 emission data acquisition were performed in a cardiac phantom (30 cm in width) with a myocardial chamber and a patient study. Tc-99m of 185 MBq was used as the transmission source. Both the ECT and TCT images were reconstructed with the filtered back-projection method after scatter correction with the triple energy window (TEW) method. The attenuation corrected transaxial images were iteratively reconstructed with the Chang algorithm utilizing the attenuation coefficient map computed from the TCT data. In this AsF sampling geometry, an imaging FOV of 50 cm was yielded. The attenuated regions appeared normal on the scatter and attenuation corrected (SAC) images in the phantom and patient study. The good quantitative accuracy on the SAC images was also confirmed by the measurement of the Tl-201 radioactivity in the myocardial chamber in the phantom study. The AsF collimation geometry that we have proposed in this study makes it easy to realize TCT data acquisition on the two-head SPECT system and to perform quantification on Tl-201 myocardial SPECT.

Aged↗

Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source.

Attenuation correction is very important for quantitative SPECT imaging. We designed an uncollimated non-uniform line array source (non-uniform LAS) for attenuation correction based on transmission computed tomography (TCT) using Tc-99m and compared its performance with an uncollimated uniform line array source (uniform LAS) in a thorax phantom study. This non-uniform LAS was attached to one camera head of a dual-head gamma camera, and transmission data were acquired with another camera head with a low-energy, general purpose, parallel-hole collimator at 50 cm-distance apart from the source. The modified TEW using a subtraction factor of 1.0 was employed to correct scattered Tc-99m photons for transmission data. In the phantom experiment, eight TCT data were acquired with the scanning time changed from 2 minutes to 20 minutes for each LAS. The Tc-99m attenuation coefficient (mu) maps with the non-uniform LAS and uniform LAS improved the statistical count variation in the mediastinum filled with water as the scanning time got longer. The Tc-99m mu-map with the non-uniform LAS and 6 minutes of scanning time had equal quality at the center of the thorax phantom to that with the uniform LAS and 16 minutes of scanning time. In conclusion, for the TCT imaging with combination of the parallel hole collimator and uncollimated Tc-99m external source the non-uniform LAS can reduce the Tc-99m radioactivity or the TCT scanning time compared with the uniform LAS.

Humans↗

Accurate scatter correction for transmission computed tomography using an uncollimated line array source.

We investigated scatter correction in transmission computed tomography (TCT) imaging by the combination of an uncollimated transmission source and a parallel-hole collimator. We employed the triple energy window (TEW) as the scatter correction and found that the conventional TEW method, which is accurate in emission computed tomography (ECT) imaging, needs some modification in TCT imaging based on our phantom studies. In this study a Tc-99m uncollimated line array source (area: 55 cm x 40 cm) was attached to one camera head of a dual-head gamma camera as a transmission source, and TCT data were acquired with a low-energy, general purpose (LEGP), parallel-hole collimator equipped on the other camera head. The energy spectra for 140 keV-photons transmitted through various attenuating material thicknesses were measured and analyzed for scatter fraction. The results of the energy spectra showed that the photons transmitted had an energy distribution that constructs a scatter peak within the 140 keV-photopeak energy window. In TCT imaging with a cylindrical water phantom, the conventional TEW method with triangle estimates (subtraction factor, K = 0.5) was not sufficient for accurate scatter correction (micro = 0.131 cm(-1) for water), whereas the modified TEW method with K = 1.0 gave the accurate attenuation coefficient of 0.153 cm(-1) for water. For the TCT imaging with the combination of the uncollimated Tc-99m line array source and parallel hole collimator, the modified TEW method with K = 1.0 gives the accurate TCT data for quantitative SPECT imaging in comparison with the conventional TEW method with K = 0.5.

Equipment Failure Analysis↗