Search PubMed⌕ Search

Biomedical subjects

Akihiro Kanamori

Publications and source records attributed to Akihiro Kanamori.

6 recordsLinked to original sources

Decrease of knee flexion torque in patients with ACL reconstruction: combined analysis of the architecture and function of the knee flexor muscles.

A decrease of deep knee flexion torque after anterior cruciate ligament (ACL) reconstruction, using a semitendinosus (and gracilis) tendon, has been reported. However, the cause of this weakness remains controversial. Architectural and functional differences in the knee flexor muscles influence this weakness. the fiber length of the semitendinosus, gracilis, semimembranosus, and biceps femoris were directly measured in six human cadavers. The flexion torque and EMG of the hamstrings were measured in both limbs of 16 patients (23+/-5 years) after ACL reconstruction (12-43 months post-operation), using ipsilateral semitendinosus tendon. Magnetic resonance imagings were taken, over both the thighs of those patients, to measure muscle volume and to confirm a state of semitendinosus tendon regeneration. The position of the musculotendinous junction of the semitendinosus was also analyzed. The fiber length of the semitendinosus and gracilis were three to four times longer than that of the semimembranosus and biceps femoris. The difference of flexion torque between the normal and ACL reconstructed limbs significantly increased as the knee flexion angle increased. The EMG value for the semimembranosus and biceps femoris of both limbs as well as the semitendinosus of the ACL reconstructed limbs, significantly reduced as the knee flexion angle was increased. The volume of the semitendinosus in the reconstructed limb was significantly smaller than in normal limbs. The regeneration of the semitendinosus tendon was confirmed in all subjects, and the musculotendinous junction position of the reconstructed limb in almost all subjects was found in further image from the knee joint space than that for the normal limb. The decrease of deep knee flexion torque, after ACL reconstruction, could be due to the atrophy and shortening of the semitendinosus after its tendon has been harvested, as well as the lack of compensation from the semimembranosus and biceps femoris, due to the architectural differences between the semitendinosus and the semimembranosus and biceps femoris.

Achilles Tendon↗

A biomechanical analysis of two reconstructive approaches to the posterolateral corner of the knee.

The objective of this study was to evaluate the effects of the biceps femoris tenodesis and popliteofibular ligament reconstruction on knee biomechanics. Ten human cadaveric knees were tested in the intact, posterolateral corner (PLC)-deficient, and PLC-reconstructed conditions using a robotic/universal force moment sensor testing system. The knees were subjected to: (1) a 134 N posterior tibial load, and (2) a 10 Nm external tibial torque applied to the tibia at full extension, 30 degrees and 90 degrees of flexion. External tibial rotation of the intact knee ranged from 18.3+/-4.6 degrees at full extension to 27.9+/-4.6 degrees at 30 degrees under the 10 Nm external tibial torque. These values increased after sectioning the PLC by 2.8 degrees -7.5 degrees at 30 degrees and 90 degrees respectively. After the popliteofibular ligament reconstruction, external tibial rotation values were not significantly different from those for the intact knee at any angle tested, while values following the biceps tenodesis were as much as 5.7 degrees greater than the intact knee. Under the 134 N posterior tibial load, there were minimal decreases in posterior tibial translation of up to 0.9 mm with the biceps tenodesis and up to 1.6 mm with the popliteofibular ligament reconstruction compared to the intact knee. The in situ forces in the biceps tenodesis were not significantly different than the intact PLC at full extension or 30 degrees, while the in situ forces in the popliteofibular graft were not significantly different at any flexion angle. Our data suggests that by restoring external tibial rotation the popliteofibular ligament reconstruction more closely reproduces the primary function of the PLC as compared to the biceps tenodesis.

Adult↗

The effect of axial tibial torque on the function of the anterior cruciate ligament: a biomechanical study of a simulated pivot shift test.

PURPOSE: Various techniques are used to produce the pivot shift phenomenon after anterior cruciate ligament (ACL) injury. In particular, the amount of applied axial tibial torque varies among examiners. Thus, the objective of this study was to determine the effect of the magnitude and direction of axial tibial torque in combination with valgus torque on the resulting knee kinematics during such a simulated pivot shift test. TYPE OF STUDY: This was a biomechanical study that used cadaveric knees with the intact knee of the same specimen serving as a control. METHODS: On 19 human cadaveric knees (age, 26 to 69 years), a constant 10-Nm valgus torque was applied at 15 degrees of knee flexion. Then, internal and external tibial torque was applied incrementally from 0 to 10 Nm and the resulting kinematics of the ACL-intact and ACL-deficient knee, as well as the in situ force in the ACL, were measured using a robotic/universal force-moment sensor testing system. RESULTS: In response to isolated valgus torque, the coupled anterior tibial translation for the ACL-intact and ACL-deficient knee was 1.6 +/- 2.4 mm and 8.5 +/- 4.7 mm, respectively; therefore the difference between the ACL-intact and ACL-deficient knee was 6.9 +/- 3.4 mm. With an external tibial torque greater than 5 Nm, the tibia translated up to 4 mm posteriorly for both the ACL-intact and ACL-deficient knee. Whereas, internal tibial torque greater than 1.6 Nm caused a rapid increase in coupled anterior tibial translation up to 10.2 mm in the ACL-deficient knee, while causing only a gradual increase for the ACL-intact knee. With excessive internal torque of 10 Nm, the difference in coupled anterior tibial translation was only 4.4 +/- 2.2 mm, suggesting a decrease in the sensitivity of the test. Correspondingly, the in situ force in the ACL under 10 Nm valgus tibial torque was 43 +/- 17 N, and increased up to 87 +/- 32 N as a 10-Nm internal torque was added. By applying a 3.3-Nm external tibial torque in addition to the 10-Nm valgus torque, the in situ force decreased to 21 +/- 14 N. CONCLUSIONS: This study showed that a minimal amount of internal torque in combination with valgus torque may be a suitable way to elicit a pivot shift from an ACL-deficient knee.

Adult↗

The effectiveness of reconstruction of the anterior cruciate ligament with hamstrings and patellar tendon . A cadaveric study comparing anterior tibial and rotational loads.

BACKGROUND: The objective of this study was to evaluate the effectiveness of reconstructions of the anterior cruciate ligament to resist anterior tibial and rotational loads. We hypothesized that current reconstruction techniques, which are designed mainly to provide resistance to anterior tibial loads, are less effective in limiting knee instability in response to combined rotational loads. METHODS: Twelve fresh-frozen young human cadaveric knees (from individuals with a mean age [and standard deviation] of 37 +/- 13 years at the time of death) were tested with use of a robotic/universal force-moment sensor testing system. The loading conditions included (1) a 134-N anterior tibial load with the knee at full extension and at 15 degrees, 30 degrees, and 90 degrees of flexion, and (2) a combined rotational load of 10 N-m of valgus torque and 10 N-m of internal tibial torque with the knee at 15 degrees and 30 degrees of flexion. The kinematics of the knees with an intact and a deficient anterior cruciate ligament, as well as the in situ force in the intact anterior cruciate ligament, were determined in response to both loads. Each knee then underwent reconstruction of the anterior cruciate ligament with use of a quadruple semitendinosus-gracilis tendon graft and was tested. A second reconstruction was performed with a bone-patellar tendon-bone graft, and the same knee was tested again. The kinematics of the reconstructed knees and the in situ forces in both grafts were determined. RESULTS: The results demonstrated that both reconstructions were successful in limiting anterior tibial translation under anterior tibial loads. Furthermore, the mean in situ forces in the grafts under a 134-N anterior tibial load were restored to within 78% to 100% of that in the intact knee. However, in response to a combined rotational load, reconstruction with either of the two grafts was not as effective in reducing anterior tibial translation. This insufficiency was further revealed by the lower in situ forces in the grafts, which ranged from 45% to 65% of that in the intact knee. CONCLUSIONS: In current reconstruction procedures, the graft is placed close to the central axis of the tibia and femur, which makes it inadequate for resisting rotational loads. Our findings suggest that improved reconstruction procedures that restore the anatomy of the anterior cruciate ligament may be needed.

Adult↗

Biomechanical analysis of an anatomic anterior cruciate ligament reconstruction.

BACKGROUND: The focus of most anterior cruciate ligament reconstructions has been on replacing the anteromedial bundle and not the posterolateral bundle. HYPOTHESIS: Anatomic two-bundle reconstruction restores knee kinematics more closely to normal than does single-bundle reconstruction. STUDY DESIGN: Controlled laboratory study. METHODS: Ten cadaveric knees were subjected to external loading conditions: 1) a 134-N anterior tibial load and 2) a combined rotatory load of 5-N x m internal tibial torque and 10-N x m valgus torque. Resulting knee kinematics and in situ force in the anterior cruciate ligament or replacement graft were determined by using a robotic/universal force-moment sensor testing system for 1) intact, 2) anterior cruciate ligament deficient, 3) single-bundle reconstructed, and 4) anatomically reconstructed knees. RESULTS: Anterior tibial translation for the anatomic reconstruction was significantly closer to that of the intact knee than was the single-bundle reconstruction. The in situ force normalized to the intact anterior cruciate ligament for the anatomic reconstruction was 97% +/- 9%, whereas the single-bundle reconstruction was only 89% +/- 13%. With a combined rotatory load, the normalized in situ force for the single-bundle and anatomic reconstructions at 30 degrees of flexion was 66% +/- 40%and 91% +/- 35%, respectively. CONCLUSIONS: Anatomic reconstruction may produce a better biomechanical outcome, especially during rotatory loads. CLINICAL RELEVANCE: Results may lead to the use of a two-bundle technique.

Analysis of Variance↗

Measurement of posterior tibial translation in the posterior cruciate ligament-reconstructed knee: significance of the shift in the reference position.

BACKGROUND: The measurement of anterior or posterior tibial translation depends on the existence of a repeatable and accurate reference position of the knee from which the corresponding translation is measured. HYPOTHESIS: Clinical measurements of posterior tibial translation alone do not accurately reflect the laxity of posterior cruciate ligament-reconstructed knees. STUDY DESIGN: Controlled laboratory study. METHODS: Ten human cadaveric knees were tested by using a robotic/universal force-moment sensor testing system. The reference positions and the resulting kinematics in response to a 134-N anterior-posterior tibial load were determined for the intact and reconstructed knees. Posterior cruciate ligament reconstruction was performed with the graft tensioned and fixed at two different positions: 1) 90 degrees of knee flexion with a 134-N anterior tibial load and 2) full extension with no load. RESULTS: Posterior cruciate ligament reconstruction with graft fixation at full extension with no load resulted in anterior shift of the reference position by 1.5 to 3.2 mm. The reconstruction resulted in an overconstrained knee with significantly decreased total anterior-posterior translation of 2.6 to 3.2 mm. However, the posterior tibial translation measured was not significantly different from that of the intact knee. Posterior cruciate ligament reconstruction with graft fixation performed at 90 degrees of flexion with a 134-N anterior tibial load resulted in kinematics similar to those of the intact knee. CONCLUSION: Posterior tibial translations that are measured clinically can be misleading because the reference position of the knee can be shifted significantly after posterior cruciate ligament reconstruction. CLINICAL RELEVANCE: The measurement of total anterior-posterior translation may be a more accurate way to assess kinematics of the reconstructed knee.

Adult↗