Integration of chemical and biochemical analysis systems into a glass microchip.

This review focuses on the integration of chemical and biochemical analysis systems into glass microchips for general use. By combining multiphase laminar flow driven by pressure and micro unit operations, such as mixing, reaction, extraction and separation, continuous-flow chemical processing systems can be realized in the microchip format, while the application of electrophoresis-based chip technology is limited. The performances of several analysis systems were greatly improved by microchip integration because of some characteristics of microspace, i.e., a large specific interface area, a short molecular diffusion time, a small heat capacity and so on. By applying these concepts, several different analysis systems, i.e., wet analysis of cobalt ion, multi-ion sensor, immunoassay, and cellular analysis, were successfully integrated on a microchip. These microchip technologies are promising for meeting the future demands of high-throughput chemical processing.

Biosensing Techniques↗

Nanochannels on a fused-silica microchip and liquid properties investigation by time-resolved fluorescence measurements.

We have fabricated nanometer-sized channels, demonstrated a technique for the introduction of liquid into the channels, and carried out time-resolved fluorescence measurements of aqueous solutions. In this study, 330-nm- and 850-nm-sized channels were fabricated on fused-silica substrates by fast atom beam etching and hydrofluoric acid bonding methods. A liquid introduction method utilizing capillary action was demonstrated. The liquid introduction was observed under an optical microscope, and the liquid velocity during the introduction was analyzed by surface energy and macroscale hydrodynamics. The liquid velocity due to capillary action in the nanometer-sized channel seemed more than four times slower than the estimation. Then, aqueous solutions of rhodamine 6G (R6G), sulforhodamine 101 (SR101), and rhodamine B (RB) in the channels were measured by time-resolved fluorescence spectroscopy; spectra of the same solution in a 250-microm-sized channel were also measured as a reference for the macrospace. Although the fluorescence spectra in the 330-nm-, 850-nm- and 250-microm-sized channels agreed with one another, the fluorescent decays in the nanometer-sized channels were faster for R6G and SR101 and slower for RB than the respective decays in the 250-microm-sized channels. The results suggested the solutions had lower dielectric constants and higher viscosities in the nanometer-sized channels.

Journal Article↗

Pile-up glass microreactor.

We made a 'pile-up' microreactor in which ten levels of microchannel circuits were integrated to form a single glass entity. Solutions were distributed to each layer via cylindrical holes with a diameter much larger than that of the microchannel. Fabrication of the pile-up reactor was completed using only conventional photolithography, wet etching and thermal bonding techniques, and no special facilities or instruments were required. An amide formation reaction between amine in aqueous solution and acid chloride in organic solution was carried out using the pile-up reactor. The yield of the amide formation reaction is dependent on the size of the specific surface area between the two solutions, and the small space inside the microchannels is good for acquiring a large specific surface area without any stirring processes. The maximum throughput for the ten-layered pile-up reactor was ten times larger than that of a single-layered one, yet the reaction yield was still high. Productivity of the pile-up reactor for the reaction was as high as on a gram per hour scale. This value suggests that many conventional plants producing fine chemicals can be replaced by microreactors through the numbering-up technology.

Journal Article↗

Three-layer flow membrane system on a microchip for investigation of molecular transport.

A stable three-layer flow system, water/organic solvent/water, has been successfully applied for the first time in a microchannel to get rapid transport through an organic liquid membrane. In the continuous laminar flow region, the analyte (methyl red) was rapidly extracted across the microchannel from the donor to the acceptor phase through the organic solvent phase (cyclohexane). Thermal lens microscopy was used to monitor the process. The thickness of the organic phase, sandwiched by the two aqueous phases, was approximately 64 microm, and it was considered as a thin liquid organic membrane. Permeability studies showed the effects of molecular diffusion, layer thickness, and organic solvent-water partition coefficient on the molecular transport. In the microchip, complete equilibration was achieved in several seconds, in contrast to a conventionally used apparatus, where it takes tens of minutes. The thickness of the organic and aqueous boundary layers was defined as equal to the microchannel dimensions, and the organic solvent-water partition coefficient was determined on a microchip using the liquid/liquid extraction system. Experimental data on molecular transport across the organic membrane were in agreement with the calculated permeability based on the three-compartment water/organic solvent/water model. This kind of experiment can be performed only in a microspace, and the system can be considered as a potential biological membrane for future in vitro study of drug transport.

Azo Compounds↗

Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels.

We demonstrated a liquid/liquid and a gas/liquid two-phase crossing flow in glass microchips. A 250-microm-wide microchannel for aqueous-phase flow was fabricated on a top glass plate. Then, as a way to utilize the surface energy difference for stable phase confluence and separation, a 250-microm-wide microchannel for organic-phase (or gas-phase) flow was fabricated on a bottom glass plate and the wall was chemically modified by octadecylsilane (ODS) group. The top and bottom plates were sealed only by pressure. A microchannel pattern was designed so that the two phases made contact at the crossing point of the straight microchannels. The crossing point was observed with an optical microscope. Results showed that the ODS modification of the microchannel wall clearly improved stability of the interface between the two fluids. Pressure difference between fluids was measured and the interface of water and nitrobenzene was stable for the pressure difference from +300 Pa to -200 Pa. The pressure drop in a countercurrent flow configuration was also estimated, and the pressure difference required to realize the counter current flow was less than the allowable pressure range. Finally, we discussed the advantages of utilizing this approach.

Journal Article↗

Continuous-flow chemical processing on a microchip by combining microunit operations and a multiphase flow network.

A new design and construction methodology for integration of complicated chemical processing on a microchip was proposed. This methodology, continuous-flow chemical processing (CFCP), is based on a combination of microunit operations (MUOs) and a multiphase flow network. Chemical operations in microchannels, such as mixing, reaction, and extraction, were classified into several MUOs. The complete procedure for Co(II) wet analysis, including a chelating reaction, solvent extraction, and purification was decomposed into MUOs and reconstructed as CFCP on a microchip. Chemical reaction and molecular transport were realized in and between continuous liquid flows in a multiphase flow network, such as aqueous/aqueous, aqueous/organic, and aqueous/organic/aqueous flows. When the determination of Co(II) in an admixture of Cu(II) was carried out using this methodology, the determination limit (2sigma) was obtained as 18 nM, and the absolute amount of Co chelates detected was 0.13 zmol, that is, 78 chelates. The sample analysis time was faster than that of a conventional processing system. Moreover, troublesome operations such as phase separation and acid and alkali washing, all necessary for the conventional system, were simplified. The CFCP methodology proposed here can be applied to various on-chip applications.

Journal Article↗