Search PubMed⌕ Search

Biomedical subjects

Adam Gacek

Publications and source records attributed to Adam Gacek.

4 recordsLinked to original sources

The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability.

Bioelectrical fetal heart activity being recorded from maternal abdominal surface contains more information than mechanical heart activity measurement based on the Doppler ultrasound signals. However, it requires extraction of fetal electrocardiogram from abdominal signals where the maternal electrocardiogram is dominant. The simplest technique for maternal component suppression is a blanking procedure, which relies upon the replacement of maternal QRS complexes by isoline values. Although, in case of coincidence of fetal and maternal QRS complexes, it causes a loss of information on fetal heart activity. Its influence on determination of fetal heart rate and the variability analysis depends on the sensitivity of the heart-beat detector used. The sensitivity is defined as an ability to detect the incomplete fetal QRS complex. The aim of this work was to evaluate the influence of the maternal electrocardiogram suppression method used on the reliability of FHR signal being calculated.

Electrocardiography↗

A granular description of ECG signals.

In this paper, we develop a general framework of a granular representation of ECG signals. The crux of the approach lies in the development and ongoing processing realized in the setting of information granules-fuzzy sets. They serve as basic conceptual and semantically meaningful entities using which we describe signals and build their models (such as various predictive schemes or classifiers). A comprehensive two-phase scheme of the design of the information granules is proposed and described. At the first phase, we discuss the temporal granulation through a series of temporal windows (granular windows) and an aggregation of the values of signal by means of fuzzy sets. To address this issue, offered is a detailed method of building a fuzzy set based on numeric data and a certain optimization criterion that strikes a balance between the highest experimental relevance of the fuzzy set supported by numeric data and its substantial specificity. At the next phase of the granular design, a collection of information granules is further summarized with the use of fuzzy clustering (Fuzzy C-Means). The resulting prototypes (centroids) formed by this grouping process serve as elements of the granular vocabulary. We discuss ways of using these vocabularies in the knowledge-based representation, modeling, and classification of ECG beats.

Algorithms↗

Computationally effective algorithm for robust weighted averaging.

One of the greatest disadvantages of the weighted signal averaging method is its sensitivity to the presence of noise and outliers in data and the need to estimate the noise variance in all signal cycles. The robust weighted averaging method based on the epsilon-insensitive loss function is free of these disadvantages, but has a very high computational burden and requires a choice of the insensitivity parameter epsilon. In this study, a new computationally effective algorithm for robust weighted averaging with automatic adjustment of the insensitivity parameter is introduced.

Algorithms↗

A genetic segmentation of ECG signals.

This paper is concerned with a development of a segmentation technique for electrocardiogram (ECG) signals. Such segmentation is aimed at a lossy signal compression in which each segment can be captured by a simple geometric construct such as, e.g., a linear or quadratic function. The crux of the proposed construct lies in the determination of the optimal segments of data over which they exhibit the highest possible monotonicity (or lowest variability) of the ECG signal. In this sense, the proposed approach generalizes a fundamental and commonly encountered problem of function (data) linearization. The segments are genetically developed using a standard technique of genetic algorithms (GAs). The two fundamental GA constructs, namely a topology of a chromosome and a fitness function governing the optimization process are discussed in detail. The chromosome being coded as a series of floating point numbers contains the endpoints of the segments (segmentation points). The fitness function to be maximized quantifies a level of monotonicity of the ECG data encountered within the segments and takes into consideration differences between the extreme values (minimum and maximum) of its derivatives. As a result of the genetic optimization, we build segments of ECG signals encompassing monotonic (increasing or decreasing) regions of the signal exhibiting a minimal level of variability. A series of experiments dealing with several classes of ECG signals (namely, normal, left bundle branch block beat, and right bundle branch block beat) visualize the effectiveness of the approach and shows the specificity of the linear segments of data. Furthermore, we elaborate on the relationship between the values of the fitness function and the approximation capabilities (quantified by a sum of squared errors between the local model and the data) of the segments of the signal and show that these two descriptors are highly related.

Algorithms↗