Search PubMed⌕ Search

Biomedical subjects

Achim Schweikard

Publications and source records attributed to Achim Schweikard.

7 recordsLinked to original sources

Fully automatic detection of corresponding anatomical landmarks in volume scans of different respiratory state.

A method is described which provides fully automatic detection of corresponding anatomical landmarks in volume scans taken at different respiratory states. The resulting control points are needed for creating a volumetric deformation model for motion compensation in radiotherapy. Prior to treatment two CT volumes are taken, one scan during inhalation, one during exhalation. These scans and the detected control point pairs are taken as input for creating the four-dimensional model by using thin-plate splines.

Algorithms↗

Resampling: an optimization method for inverse planning in robotic radiosurgery.

By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design permits a large number of distinct beam directions to be used in one single treatment. These major technical differences provide an opportunity to improve upon the well-established principles for treatment planning used with GammaKnife or LINAC radiosurgery. With this objective in mind, our group has developed over the past decade an inverse planning tool for robotic radiosurgery. This system first computes a set of beam directions, and then during an optimization step, weights each individual beam. Optimization begins with a feasibility query, the answer to which is derived through linear programming. This approach offers the advantage of completeness and avoids local optima. Final beam selection is based on heuristics. In this report we present and evaluate a new strategy for utilizing the advantages of linear programming to improve beam selection. Starting from an initial solution, a heuristically determined set of beams is added to the optimization problem, while beams with zero weight are removed. This process is repeated to sample a set of beams much larger compared with typical optimization. Experimental results indicate that the planning approach efficiently finds acceptable plans and that resampling can further improve its efficiency.

Computer Simulation↗

Computer aided robotic radiosurgery.

Radiosurgery involves the precise delivery of sharply collimated high-energy beams of radiation to a distinct target volume along selected trajectories. Historically, accurate targeting required the application of a stereotactic frame, thus limiting the use of this procedure to single treatments of selected intracranial lesions. However, the scope of radiosurgery has undergone a remarkable broadening since the introduction of image-guided robotic radiosurgery. Recent developments in real-time image guidance provide an effective frameless alternative to conventional radiosurgery and allow both the treatment of lesions outside the skull and the possibility of performing hypofractionation. As a consequence, targets in the spine, chest and abdomen can now also be radiosurgically ablated with submillimetric precision. Meanwhile, the combination of image guidance, robotic beam delivery, and non-isocentric inverse planning can greatly enhance the conformality and homogeneity of radiosurgery. The aim of this article is to describe the technological basis of image-guided radiosurgery and provide a perspective on future developments. The current clinical usage of robotic radiosurgery will be reviewed with an emphasis on those applications that may represent a major shift in the therapeutic paradigm.

Brain Neoplasms↗

Planning and analyzing robotized TMS using virtual reality.

Transcranial Magnetic Stimulation (TMS) is a powerful method to examine the brain and non-invasively treat disorders of the central nervous system. Magnetic stimulation of the motor cortex results in the activation of corresponding muscle groups. Hereby, accurate placement of the TMS coil to the patient's head is crucial to successful stimulation. We developed a way to position the TMS coil using a robot and navigate it in virtual reality based on an online registration of the cranium relative to 3D magnetic resonance imaging data. By tracking the head and robotic motion compensation, fixation of the patient's head becomes obsolete. Furthermore, a novel method for motor cortex mapping is presented. The robotized TMS system is used to obtain the characteristic field of a TMS coil. This field is registered to the field of motor evoked potential measurements at the patient's head to yield a prediction of the motoric center of a target muscle.

Brain Mapping↗

Respiration tracking in radiosurgery.

Respiratory motion is difficult to compensate for with conventional radiotherapy systems. An accurate tracking method for following the motion of the tumor is of considerable clinical relevance. We investigate methods to compensate for respiratory motion using robotic radiosurgery. In this system the therapeutic beam is moved by a robotic arm, and follows the moving target through a combination of infrared tracking and synchronized x-ray imaging. Infrared emitters are used to record the motion of the patient's skin surface. The position of internal gold fiducials is computed repeatedly during treatment, via x-ray image processing. We correlate the motion between external and internal markers. From this correlation model we infer the placement of the internal target during time intervals where no x-ray images are taken. Fifteen patients with lung tumors have recently been treated with a fully integrated system implementing this new method. The clinical trials confirm our hypothesis that internal motion and external motion are indeed correlated. In a preliminar study we have extended our work to tracking without implanted fiducials, based on algorithms for computing deformation motions and digitally reconstructed radiographs.

Clinical Trials as Topic↗

Numerical determination of the susceptibility caused geometric distortions in magnetic resonance imaging.

The goal of this work is the design of highly accurate surgical navigation methods purely based on magnetic resonance imaging. In this context we numerically examine the geometrical distortions which occur in magnetic resonance imaging. We extend an existing method for computing magnitude and direction of distortions for any internal point. In particular, a multi-grid approach for a fast and efficient calculation of the static magnetic field throughout the imaging volume is presented and compared to the analytical solution for simple geometries. We found that shifts in the range of up to 2.5 mm occur in MRI of femur bones with 1.5 Tesla. Our new method was implemented and has been found capable of accurately correcting for geometrical distortions within reasonable computing times. In particular, we show that the registration accuracy for mutual information (MI) based MR-CT fusion can be much improved. Thus the value of the optimization functional in MI registration for MR-CT substantially increases after our distortion correction.

Abdomen↗

[Design of an inverse planning system for radiotherapy using linear optimization].

Our approach shows that inverse planning for intensity-modulated beams in radiotherapy can be solved efficiently by the mathematical method of linear optimization. The completeness property of this method guarantees that calculated treatment plans fulfill the dose constraints given by the oncologist. Techniques developed by our group can also avoid the possible infeasibility caused by a physically impossible dose distribution. In contrast to other optimization methods, the simplex algorithm used for linear optimization allows a very high optimization speed, i.e., very short planning cycles. These preconditions were integrated in the development of the software system MIPART ("Munich Inverse Planning And Radiotherapy Treatment"). The object-oriented software architecture of MIPART achieves a maximum of extensibility and flexibility. Our clinical tests show that MIPART can be easily integrated in the clinical routine in spite of the complexity of data in the field of intensity-modulated radiotherapy. Moreover, qualitatively better treatment plans can be generated than in conventional treatment planning, especially in complicated cases.

Humans↗