Search PubMed⌕ Search

Biomedical subjects

Abd-Elgawad Radi

Publications and source records attributed to Abd-Elgawad Radi.

4 recordsLinked to original sources

Reagentless, reusable, ultrasensitive electrochemical molecular beacon aptasensor.

A bifunctional derivative of the thrombin-binding aptamer with a redox-active Fc moiety and a thiol group at the termini of the aptamer strand was synthesized. The ferrocene-labeled aptamer thiol was self-assembled through S-Au bonding on a polycrystalline gold electrode surface and the surface was blocked with 2-mercaptoethanol to form a mixed monolayer. By use of a fluorescent molecular beacon, the effect of counterions on quadruplex formation was established. The aptamer-modified electrode was characterized electrochemically by cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The modified electrode showed a voltammetric signal due to a one-step redox reaction of the surface-confined ferrocenyl moiety of the aptamer immobilized on the electrode surface in 10 mM N-(2-hydroxyethyl)piperazine-N'-2-ethanesulfonic acid (HEPES) buffer of pH 8.0. An increase in the DPV current signal was evident after blocking with 2-mercaptoethanol, effectively removing aptamer nonspecifically absorbed rather than bound to electrode surface or due to the formation of the aptamer-thrombin affinity interaction. The impedance measurement, in agreement with the differential pulse voltammetry (DPV), showed decreased Faradaic resistances in the same sequence. The "signal-on" upon thrombin association could be attributed to a change in conformation from random coil-like configuration on the probe-modified film to the quadruplex structure. The DPV of the modified electrode showed a linear response of the Fc oxidation signal to the increase in the thrombin concentration in the range between 5.0 and 35.0 nM with a linear correlation of r = 0.9988 and a detection limit of 0.5 nM. The molecular beacon aptasensor was amenable to full regeneration by simply unfolding the aptamer in 1.0 M HCl, and could be regenerated 25 times with no loss in electrochemical signal upon subsequent thrombin binding.

Aptamers, Nucleotide↗

Reusable impedimetric aptasensor.

A novel impedimetric aptasensor using a mixed self-assembled monolayer composed of thiol-modified thrombin binding aptamer and 2-mercaptoethanol on a gold electrode is reported. The changes of interfacial features of the electrode were probed in the presence of the reversible redox couple, Fe(CN)6(3-/4-), using impedance measurements. The electrode surface was partially blocked due to the self-assembly of aptamer or the formation of the aptamer-thrombin complex, resulting in an increase of the interfacial electron-transfer resistance detected by electrochemical impedance spectroscopy or cyclic voltammetry. The aptasensor was regenerated by breaking the complex formed between the aptamer and thrombin using 2.0 M NaCl solution, and the immobilized aptamer subsequently was used for repeated detection of thrombin. The aptamer-functionalized electrode showed a linear response of the charge-transfer resistance to the increase of thrombin concentration in the range of 5.0-35.0 nM and the thrombin was easily detectable to a concentration of 2.0 nM.

Aptamers, Nucleotide↗

Electrochemical study of zolpidem at glassy carbon electrode and its determination in a tablet dosage form by differential pulse voltammetry.

The oxidative behaviour of, a hypnotic drug, zolpidem was studied at glassy carbon electrode in Britton-Robinson buffer over the pH range 2.0-11.0 using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug was effected in a single irreversible, diffusion-controlled step. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 8.0 at +0.889 V (vs. Ag/AgCl) on glassy carbon electrode. This process could be used to determine zolpidem concentrations in the range 5.0 x 10(-7) M to 1.0 x 10(-5) M with a detection limit of 2.0 x 10(-7) M. The method was applied, without any interference from the excipients, to the determination of the drug in a tablet dosage form.