32-element receiver-coil array for cardiac imaging.

A lightweight 32-element MRI receiver-coil array was designed and built for cardiac imaging. It comprises an anterior array of 21 copper rings (75 mm diameter) and a posterior array of 11 rings (107 mm diameter) that are arranged in hexagonal lattices so as to decouple nearest neighbors, and curved around the left side of the torso. Imaging experiments on phantoms and human volunteers show that it yields superior performance relative to an eight-element cardiac array as well as a 32-element whole-torso array for both traditional nonaccelerated cardiac imaging and 3D parallel imaging with acceleration factors as high as 16.

Algorithms↗

Toward single breath-hold whole-heart coverage coronary MRA using highly accelerated parallel imaging with a 32-channel MR system.

Coronary MR angiography (CMRA) is generally confined to the acquisition of multiple targeted slabs with coverage dictated by the competing constraints of signal-to-noise ratio (SNR), physiological motion, and scan time. This work addresses these obstacles by demonstrating the technical feasibility of using a 32-channel coil array and receiver system for highly accelerated volumetric breath-hold CMRA. The use of the 32-element array in unaccelerated CMRA studies provided a baseline SNR increase of as much as 40% over conventional cardiac-optimized phased array coils, which resulted in substantially enhanced image quality and improved delineation of the coronary arteries. Modest accelerations were used to reduce breath-hold durations for tailored coverage of the coronary arteries using targeted multi-oblique slabs to as little as 10 s. Finally, high net accelerations were combined with the SNR advantages of a 3D steady-state free precession (SSFP) technique to achieve previously unattainable comprehensive volumetric coverage of the coronary arteries in a single breath-hold. The merits and limitations of this simplified volumetric imaging approach are discussed and its implications for coronary MRA are considered.

Coronary Angiography↗

Inherently self-calibrating non-Cartesian parallel imaging.

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Algorithms↗

Rapid volumetric MRI using parallel imaging with order-of-magnitude accelerations and a 32-element RF coil array: feasibility and implications.

RATIONALE AND OBJECTIVES: Many clinical applications of Magnetic Resonance Imaging are constrained by basic limits on imaging speed. Parallel MRI relaxes these limits by using the sensitivity patterns of arrays of radiofrequency receiver coils to encode spatial information in a manner complementary to traditional encoding with magnetic field gradients. Until now, parallel MRI has been used to achieve modest improvements in imaging speed; order-of-magnitude improvements have been elusive given fundamental losses in signal-to-noise ratio. The goal of this work was to demonstrate that, with appropriate hardware and careful SNR management, rapid volumetric imaging at high accelerations is in fact feasible. MATERIALS AND METHODS: Contrast-enhanced MRI with an axial 3D spoiled gradient echo imaging sequence was performed in healthy adult subjects using a 32-element RF coil array and a prototype 32-channel MR imaging system. Large imaging volumes were prescribed, in place of traditional limited slabs targeted only to suspect regions. RESULTS: As much as 16-fold net accelerations of imaging were achieved repeatably using this approach. The use of large 3D volumes allowed comprehensive anatomical coverage at clinically useful spatial and/or temporal resolution. The need for careful, time-consuming, and subject-specific scan prescription was also eliminated. CONCLUSION: The highly parallel imaging approach presented here allows previously inaccessible volumetric coverage for time-sensitive MRI examinations such as contrast-enhanced MRA, and simultaneously provides a substantially simplified imaging paradigm. The resulting capability for rapid volumetric imaging promises to combine the strengths of MRI with some of the advantages of alternative imaging modalities such as multidetector CT.

Adult↗

Phase-constrained parallel MR image reconstruction.

A generalized method for phase-constrained parallel MR image reconstruction is presented that combines and extends the concepts of partial-Fourier reconstruction and parallel imaging. It provides a framework for reconstructing images employing either or both techniques and for comparing image quality achieved by varying k-space sampling schemes. The method can be used as a parallel image reconstruction with a partial-Fourier reconstruction built in. It can also be used with trajectories not readily handled by straightforward combinations of partial-Fourier and SENSE-like parallel reconstructions, including variable-density, and non-Cartesian trajectories. The phase constraint specifies a better-conditioned inverse problem compared to unconstrained parallel MR reconstruction alone. This phase-constrained parallel MRI reconstruction offers a one-step alternative to the standard combination of homodyne and SENSE reconstructions with the added benefit of flexibility of sampling trajectory. The theory of the phase-constrained approach is outlined, and its calibration requirements and limitations are discussed. Simulations, phantom experiments, and in vivo experiments are presented.

Algorithms↗

Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations.

A method is described for establishing an upper bound on the spatial encoding capabilities of coil arrays in parallel MRI. Ultimate intrinsic signal-to-noise ratio (SNR), independent of any particular conductor arrangement, is calculated by expressing arbitrary coil sensitivities in terms of a complete set of basis functions that satisfy Maxwell's equations within the sample and performing parallel imaging reconstructions using these basis functions. The dependence of the ultimate intrinsic SNR on a variety of experimental conditions is explored and a physically intuitive explanation for the observed behavior is provided based on a comparison between the electromagnetic wavelength and the distance between aliasing points. Imaging at high field strength, with correspondingly short wavelength, is shown to offer advantages for parallel imaging beyond those already expected due to the larger available spin polarization. One-dimensional undersampling of k-space yields a steep drop in attainable SNR for more than a 5-fold reduction of scan time, while 2D undersampling permits access to much higher degrees of acceleration. Increased tissue conductivity decreases baseline SNR, but improves parallel imaging performance. A procedure is also provided for generating the optimal coil sensitivity pattern for a given acceleration, which will serve as a useful guide for future coil designs.

Algorithms↗