Search PubMed⌕ Search

Biomedical subjects

A Wilke

Publications and source records attributed to A Wilke.

At least 19 recordsLinked to original sources

BRIGEP--the BRIDGE-based genome-transcriptome-proteome browser.

The growing amount of information resulting from the increasing number of publicly available genomes and experimental results thereof necessitates the development of comprehensive systems for data processing and analysis. In this paper, we describe the current state and latest developments of our BRIGEP bioinformatics software system consisting of three web-based applications: GenDB, EMMA and ProDB. These applications facilitate the processing and analysis of bacterial genome, transcriptome and proteome data and are actively used by numerous international groups. We are currently in the process of extensively interconnecting these applications. BRIGEP was developed in the Bioinformatics Resource Facility of the Center for Biotechnology at Bielefeld University and is freely available. A demo project with sample data and access to all three tools is available at https://www.cebitec.uni-bielefeld.de/groups/brf/software/brigep/. Code bundles for these and other tools developed in our group are accessible on our FTP server at ftp.cebitec.uni-bielefeld.de/pub/software/.

Bacterial Proteins↗

[Preoperative marking of thoracic disc herniation].

INTRODUCTION: The operative therapy for thoracic disc herniations not only presents high demands on the operating surgeon, but also an additional difficulty in the certain identification of intraoperative height localisation. In this retrospective case analysis, we examine the value and practicability of CT-guided percutaneous marking for localisation of the appropriate vertebral segment. METHODS AND RESULTS: Between 1986 and 1998, eight patients were treated for a thoracic disc herniation. For these patients, the intraoperative height localisation was determined by a BV system. In two cases, healthy intervertebral discs were accidentally removed due to a faulty height localisation. DISCUSSION: At present, the intraoperative use of BV systems for localizing affected intervertebral segments in the operative therapy of a thoracic disc herniation is finding growing application.

Adult↗

[Cytokine profile of a human bone marrow cell culture under the influence of UHMW-PE wear particles].

There is considerable evidence that orthopaedic wear debris plays a crucial role in the pathology of aseptic loosening of joint prostheses. The purpose of the present study was to evaluate the influence of ultra-high-molecular-weight polyethylene (UHMW-PE) on the cytokine response in a modified in vitro model. UHMW-PE particles (psi < 7.5 microm) were suspended in soluble collagen type I and subsequently solidified in different concentrations (105,106 and 107 particles per well) on the bottom of the wells. Human bone marrow cells in a concentration of 3 x 106 cells per well were seeded on the collagen-particle substrata and maintained for up to 12 days. The cytokine response (IL-1_, IL-6 and TNF-_) of the cells to the particles were examined by ELISA compared to cells on control collagen surfaces without any particles. Assays for viability using LDH activity were done immediately. Light and scanning microscopic evaluation revealed that the UHMWPE particles, which have built large conglomerates (psi7.5_m), were mainly surrounded by the cells and less phagocytosed. The results of the cytokine release revealed significant differences in interleukin (IL)6, tumor necrosis factor (TNF)- _ and IL-1beta. The cell viability was not affected by the UHMW-PE particles. The results demonstrate that the particle induced cytokine response by UHMW-PE is mainly by the release of Interleukin 6 and TNF- _. Moreover the results confirm that the present method is useful to evaluate the in vitro effects of UHMW-PE wear particles with direct particle cell contact.

Bone Marrow Cells↗

[Histomorphometric evaluation of bone ingrowth of porous titanium by a computer-assisted analyzing system].

The objective of this study was to evaluate the bone ingrowth of a new vacuum plasma sprayed titanium surface (vps-ti) in comparison to cs-titanium implants in a göttinger minipig model. Fifteen göttinger minipigs each received the two implants, vacuum plasma sprayed titanium with a porosity of 50% and a pore size of 200 microm (vps-ti) and an implant with a similar porosity but a different pore size 500 microm (cs-ti), at the proximal femur metaphysis by press-fit technique. The pigs were euthanized at three different postsurgical periods: 4, 8 and 12 weeks. Each femur was harvested and qualitative (macroscopic and microscopic) and quantitative (histomorphometric) histological analysis was done on histological slides. The results indicated that there was a difference in bone ingrowth between the two implants, whereas the bone ingrowth of vps-ti was superior to cs-ti after 4 and 8 weeks healing time. 12 weeks post implantationem no statistiscal difference was evident. The pore size of 200 microm seemed superior to a pore size of 500 microm. Whether or not these effects lead to a better mechanical stability remains unanswered.

Animals↗

Development of a high-performance-liquid-chromatographic method for the determination of biapigenin in biorelevant media.

A new precise, rapid and selective high-performance-liquid-chromatographic (HPLC) method has been developed to quantify biapigenin in St. John's Wort (SJW) preparations and to investigate its release characteristics in the dissolution test using both compendial and biorelevant media. Experiments were carried out on a LiChroCart 125-4, RP-18 (5 microm) column, using gradient elution at a flow rate of 1 ml/min. The binary mobile phase consisted of solvent A (acetic acid, 5:100, w:w) and B (a mixture of acetonitrile and methanol (3:1, v:v)). Detection was performed at a wavelength of 270 nm using a photodiodearray detector. The limit of detection was 0.05 microg/ml, the injection volume 20 microl. Five SJW preparations were chosen to determine the amount of biapigenin in the dosage form and to investigate their release characteristics. Best results in terms of release as well as discriminating the tested products were obtained, using fed state simulated intestinal fluid (FeSSIF), where over 80% of biapigenin was dissolved after 20 min comparing to 70% using simulated gastric fluid sine pepsin (SGF(sp)) as compendial medium. Experiments in fasted state simulated intestinal fluid (FaSSIF) show 80% release of biapigenin within 80 min.

Apigenin↗

Comprehensive biocompatibility testing of a new PMMA-hA bone cement versus conventional PMMA cement in vitro.

For more than 50 years PMMA bone cements have been used in orthopaedic surgery. In this study attempts were made to show whether cultured human bone marrow cells (HBMC) show an osteogenetic response resulting in new bone formation, production of extracellular matrix (ECM) and cell differentiation when they were cultured onto polymerized polymethylmethacrylate (PMMA)-hydroxyapatite (HA), conventional PMMA bone cement being taken as reference. Biocompatibility parameters were collagen-I and -II synthesis, the detection of the osteoblast markers alkaline phosphatase (ALP) and osteocalcin, the number of adherent cells and the cytodifferentiation of immunocompetent cells. Cement surface structure, HA stability in culture medium and chemical element analysis of specimens were considered. Fresh marrow cells were obtained from the human femora during hip replacement. Incubation time was up to ten weeks. We used atomic forced microscopy (AFM) and scanning electron microscopy (SEM) for cement specimen analysis. Fluorescent activated cell sorter (FACS), immunohistochemical staining. SEM and light microscopy (LM) served us to judge the cellular morphology. Products of the extracellular matrix were analyzed by protein dot blot analysis, SEM energy dispersive X-ray analysis (SEM-EDX) and Ca2+/PO(4)3- detection. HA particles increased the osteogenetic potential of PMMA bone cement regarding the cellular production of collagen, alkaline phosphatase (AP), the number of osteoblasts and the cellular differentiation pattern in vitro. Both tested cements showed good biocompatibility in a human long-term bone marrow cell-culture system.

Bone Cements↗

[Analysis of factors affecting the prognosis of vertebral metastases].

The goal of this study was to evaluate factors for the prognosis of patients with metastatic spinal tumors. 139 patients with vertebral metastases were studied. The modified Tokuhashi Score (a preoperative score composed of six parameters) and single factors were analysed with statistical methods. The modified Tokuhashi Score showed a significant correlation (p = 0,0019) with survival time of patients. Additionally, only the Karnofsky Index as single parameter showed statistically significant correlation(p = 0.0016). Regarding the logistic regression, primary tumor, age, sex and Karnofsky Index were identified as prognostic factors for survival time. This trial could demonstrate that the Tokuhashi Score is a successful predicting tool for the assessment of prognosis of patients with vertebral metastases.

Adult↗

Comparative analysis of the biosorption of cadmium, lead, nickel, and zinc by algae.

Thirty strains of algae were examined for their biosorption abilities in the uptake of cadmium, lead, nickel, and zinc from aqueous solution. A wide range of adsorption capacities between the different strains of algae and between the four metals can be observed. The cyanophyceae Lyngbya taylorii exhibited high uptake capacities for the four metals. The algae showed maximum capacities according to the Langmuir Adsorption Model of 1.47 mmol lead, 0.37 mmol cadmium, 0.65 mmol nickel, and 0.49 mmol zinc per gram of dry biomass. The optimum pH for L. taylorii was between pH 3 and 7 for lead, cadmium, and zinc and between pH 4 and 7 for nickel. Studies with the algae indicated a preference for the uptake of lead over cadmium, nickel, and zinc in a four metal solution. The metal binding abilities of L. taylorii could be improved by phosphorylation of the biomass. The modified biosorbent demonstrated maximum capacities of 2.52 mmol cadmium, 3.08 mmol lead, 2.79 mmol nickel, and 2.60 mmol zinc per gram of dry biomass. Investigations with phosphated L. taylorii indicated high capacities for the four metals also at low pH. The selectivity remained quite similar to the unmodified algae.

Absorption↗

Cell differentiation under the influence of rh-BMP-2.

Bioactive bone growth factors will likely play an important role in the regeneration of bone. BMP-2 is known to promote osteoblastic cell differentiation and osteogenesis. Whether the BMPs act on human osteoblastic cells by increasing immature cell growth and/or differentiation is unknown. The goal of this study was to analyse possible effects of rhBMP-2 on cell differentiation using a human bone marrow cell culture. rhBMP-2 was added to the culture medium once. Fourteen days after addition of rhBMP-2 the cells were incubated with monoclonal antibodies. The cells were counted and analysed in a fluorescence-activating cell sorter (FACS). Compared to the controls there was an increasing effect on granulocytes, B cells and stem cells. The T-cells and monocytes show no increase or decrease after rhBMP-2 treatment.

Adult↗

A new semirigid implant for instrumentation of scoliosis: preliminary report.

A new set of pedicle screws, lamina and pedicle hooks, longitudinal rods and a titanium cable was developed to overcome the increasingly obvious hazards of overly rigid spinal instrumentation. Results of the first 12 consecutive scoliosis patients with this new system are reported, with an average follow-up time of 18 months. No major complications occurred. The average correction of the deformity was well within the range of more rigid systems. The new Dorsal Dynamic Spondylodesis (DDS) system proved to be easy to use, fast, powerful, safe, versatile, and biomechanically sound. Reduction of stress-shielding effects and protection of adjacent segments can be expected, and the system warrants future application in selected prospective cases with long-term follow-up.

Equipment Design↗

Batch-to-batch reproducibility of St. John's wort preparations.

Over the last few years, St. John's Wort products have enjoyed a tremendous surge in interest and sales for the therapy of mild to moderate depression. Although the complete spectrum of active substances in this herbal extract has not yet been elucidated, it is certain that hyperforin is an important component. Further, it appears that the hypericins may also contribute to the antidepressive activity. In this study, the content uniformity of eleven St. John's Wort products sold exclusively in pharmacies was determined. The main objective was to determine the batch-to-batch reproducibility of the various products. The hyperforin was analysed according to a previously published HPLC method, while the total hypericin content was determined by an electrochemical method. The results indicate that some, but not all, products show very reproducible batch-to-batch properties. Also, individual products have different hypericin and hyperforin levels, and are therefore not switchable--even when products are manufactured under similar extraction and processing conditions, have the same raw material:extract ratios (on a dry basis) and contain the same amount of extract per unit dosage form.

Anthracenes↗

Evaluation of bioresorbable polymers of lactic acid in a culture of human bone marrow cells.

Long term cultures of human bone marrow cells on poly(L-lactide-co-D,L-lactide) 70:30 and 90:10 plates were observed by means of scanning electron microscopy (SEM), SEM-EDX (SEM combined with energy dispersive X-ray analysis), flow cytometry, histochemical stainings, and culture medium analysis. After 14 days culture, cell numbers were only slightly lower compared with our reference material, hydroxyapatite, and much higher compared with polyethylene. There was evidence of collagenous matrix production with osteoblast activity. Acridine orange stainings as well as flow cytometry after incubation with propidium iodide showed only a few non-viable cells. By means of flow cytometry, we found about 30% of cells with granulocyte-markers, some monocyte-derived cells, and only small amounts of lymphocytes. After 9 weeks culture, there was evidence of calcium-phosphate deposition with extracellular matrix. There were only slight differences between the two tested polymers. Our culture system with human bone marrow cells plated on two bioresorbable polymers suggests a biocompatibility almost as good as hydroxyapatite, which is usually well tolerated. There was even evidence of mineralized collagenous matrix after some weeks of culture, which was detected earlier than the mineralization of cell-free controls.

Biocompatible Materials↗

[Recurrent ventricular fibrillation after defibrillation in a patient with pacemaker].

HISTORY: A 62-year-old patient was admitted for an operation of a hernia of the right groin in the surgical department. He had a dual chamber pacemaker because of a binodal disease. Pre-operatively the patient was reanimated because of ventricular fibrillation in dilated cardiomyopathy and was defibrillated 12 times, unexpectedly often. DIAGNOSIS: The reason of the repeated ventricular fibrillation was a spike-on-T-phenomenon due to loss of the sensing function of the pacemaker (entrance bloc). TREATMENT: Therefore, the pacemaker was explanted, and the ventricular fibrillation came to an end. The patient recovered. CONCLUSIONS: The repeated defibrillations with the electrodes over the basis and the apex of the heart damaged the pacemaker. The following fibrillation episodes were founded on a spike-on-T-phenomenon. In order to prevent such damage of pacemakers, pacemaker patients should be defibrillated and cardioverted in anterior-posterior position of the electrodes.

Cardiomyopathy, Dilated↗

Missing osteoconductive effect of a resorbable PEO/PBT copolymer in human bone defects: a clinically relevant pilot study with contrary results to previous animal studies.

PEO/PBT 70/30 (POLYACTIVE(R) 70/30), a degradable porous copolymer with elastic properties, was found to be osteoconductive in many animal studies. The aim of this study was to determine the osteoconductive effect in a human paired control iliac defect model. In seven patients undergoing anterior spinal interbody fusion surgery, two bicortical iliac defects for autograft harvesting were created. The defect size was identical for both defects measuring about 40 x 15 mm (group I). One defect was filled with the degradable implants, whereas the remaining one was left untreated as a control. The defect site for treatment was chosen randomly. In three further patients, only one defect measuring about 40 x 35 mm was created (group II). All patients were examined clinically and radiologically by spiral-CT after 1, 6, 12, 24, and 52 weeks. Three-dimensional reconstructions as well as CT-volumetric measurements using 1 mm sections were used as evaluation methods. In group I, a two-tailed paired t-test showed that the treated defects had significantly less formation of new bone than the untreated ones (p < 0.05 after 12 weeks, p < 0.01 after 52 weeks). Also, in group II, not much bone ingrowth could be observed. The histological evaluation of one patient in group I revealed no bone within the pores, and a fibrous layer between bone and implant was always present. Therefore, PEO/PBT 70/30 cannot be recommended as a bone substitute for clinical use. Differences in bone regeneration between humans and certain animal species as well as inapplicable defect models in previous animal studies are discussed as possible reasons for the failure.

Animals↗

Loosening of a fenestrated femoral prosthesis: a case report with histomorphologic analysis.

The explanted loose stem of a trabecular cementless femoral prosthesis (Holz-Copf) was histologically analyzed revealing soft tissue 3 mm thick between the metal of the prosthesis and the cancellous bone. Direct contact between the implant and bone could not be found. Removal of the prosthesis was impossible by simple extraction so that a transfemoral approach was required. Prostheses with large fenestrations may be loose but at the same time ingrown with sufficient bone to require invasive procedures for their removal.

Arthritis↗

Thoracic disc herniation: a diagnostic challenge.

An unusual case of lower thoracic disc herniation combined with shoulder pain is presented in this case report, A literature search showed that shoulder pain associated with a lower thoracic disc herniation has not yet been reported. An acromioplasty for chronic impingement syndrome was performed to relieve the patient's shoulder symptoms. An unsatisfactory outcome plus a progressive but incomplete paraplegia, prompted further investigation and this revealed a low thoracic herniation. The nucleotomy which followed afterwards lead to a rapid improvement of both the shoulder symptoms and the incomplete paraplegia. This case report shows that chronic shoulder pain may be caused or exacerbated by a thoracic disc herniation in the low thoracic spine. Therefore, prior to performing surgery for peripheral joint symptomatology, the possibility of a central sensitising trigger should be excluded by physical examination of neural tissue dynamics as well as any other necessary confirmatory investigations.

Adult↗

[Angina pectoris in extracoronary diseases].

Chest pain can arise from cardiovascular or noncardiovascular causes. Among the latter are the skin, the chest wall, intrathoracic structures, or subdiaphragmatic organs. The problem to attribute the chest discomfort to either the heart or extracardiac organs arises because the heart, pleura, aorta, and esophagus are all supplied by sensory fibers from the same spinal segments. In contrast to the diseases mentioned above, angina pectoris in sensu strictu is defined as chest pain or discomfort of cardiac origin that arises because of temporary imbalance between myocardial oxygen supply and demand. The metabolic oxygen requirements of the myocardium are essentially dictated by myocardial contraction since only a fraction of the consumed oxygen is needed by the quiescent heart. Therefore, the factors that primarily influence myocardial oxygen consumption include heart rate, the force of cardiac contraction, and myocardial wall tension, as determined by pressure (afterload), volume (preload), and wall thickness. Extracoronary diseases, e.g. hypertensive heart disease, aortic stenosis or cardiomyopathies, can influence these factors and induce angina pectoris (Figure 1). On the other hand, different diseases influencing the oxygen supply, e.g. anemia, can cause angina pectoris, too. In addition, the modulation of the coronary tone by mediators and cytokines can cause angina, coronary spasm being one example. The neurophysiological substrate of angina pectoris are ganglia which are present within the heart, particularly in epicardial fat. The sympathetic nervous system is the main conveyer of afferent pain fibers from the heart and pericardium, but many fibers may travel by the vagus and the phrenic nerves. Therefore, multiple thoracic structures may cause similar pain syndromes in the distressed patient. The blood supply of intrinsic cardiac ganglia arises primarily from branches of the proximal coronary arteries. Adenosine, among a number of substances, can modulate the activity generated by cardiac afferent nerve endings and intrinsic cardiac neurones. During myocardial ischemia adenosine is released in large quantities into the interstitial space. Given as an intravenous bolus to healthy volunteers or to patients with ischemic heart disease and angina pectoris, adenosine provokes angina pectoris-like pain, which is similar to habitual angina pectoris with regard to quality and location. But other mediators (e.g. bradykinin, histamine, prostaglandins, potassium, lactate) can be involved in the development of angina pectoris, too. As most emphasis should be given to the most serious causes first, the cardiologist has to consider ischemic cardiac disease in the differential diagnosis of nearly every case of acute chest pain. The differential diagnosis contains several causes of nonischemic cardiac chest pain. Dissecting aortic aneurysm may cause severe anterior chest pain that can be mistaken for myocardial infarction. Patients frequently will note the sudden onset of the pain rather than the relatively slower onset of ischemic pain. Furthermore, they feel as a tear and describe it as the most severe pain they have ever had. Pericarditis can be characterized as a sharp precordial knife-like pain that is often increased by lying down, breathing, swallowing, or any other thoracic motion. Radiation of pericardial pain is often relieved by sitting up or leaning forward. It may involve the shoulders, upper back, and neck because of the irritation of the diaphragmatic pleura. Acute pulmonary embolism is associated with severe chest pain. It may mimic acute myocardial infarction. Pulmonary embolism should be suspected when dyspnea or tachypnea seems to be disproportionate to the severity of the chest pain. Diffuse esophageal spasm is the extracardiac condition that is confused most often with ischemic cardiac chest pain. This pain presents as a deep thoracic pain that may be present over most of the thorax. It may extend down the anterome

Angina Pectoris↗

Implant fixation by bone ingrowth.

The term osseointegration referred originally to an intimate contact of bone tissue with the surface of a titanium implant; the term bone ingrowth refers to bone formation within an irregular (beads, wire mesh, casting voids, cut grooves) surface of an implant. The section dealing with the historical background describes the development of macroporous, microporous, and textured surfaces with an emphasis on the evolution of porous and textured metal surfaces. The principal requirements for osseointegration and bone ingrowth are systematically reviewed as follows: i) the physiology of osseointegration and bone ingrowth, including biomaterial biocompatibility with respect to cellular and matrix response at the interface; ii) the implant surface geometry characteristics; iii) implant micromotion and fixation modes; and iv) the implant-bone interface distances. Based on current methods of bone ingrowth assessment, this article comparatively reviews and discusses the results of experimental studies with the objective of determining local and systemic factors that enhance bone ingrowth fixation.

Animals↗