Search PubMed⌕ Search

Biomedical subjects

A Warsinke

Publications and source records attributed to A Warsinke.

13 recordsLinked to original sources

Homogeneous indirect fluorescence quenching immunoassay for the determination of low molecular weight substances.

This paper describes the principle of a homogeneous indirect fluorescence quenching immunoassay that uses monoclonal antibodies. It is a carrier-free assay system that is performed completely in solution. The assay system was established for the determination of a low molecular weight substance (hapten), the herbicide diuron, used as a model analyte. A fluorescein-monuron conjugate together with a fluorescence-quenching monoclonal anti-fluorescein antibody and an anti-analyte antibody (here an anti-diuron/monuron monoclonal antibody) were used as central components of the assay. The fluorescein-monuron conjugate can be bound either by the anti-fluorescein monoclonal antibody or by the anti-diuron/monuron monoclonal antibody. Due to steric hindrance, binding of both antibodies to the conjugate was not possible at the same time. By selecting the antibody concentrations appropriately, a dynamic equilibrium can be established that permits the preferential binding of the anti-diuron/monuron antibody to the conjugate, which allows the fluorescein in the conjugate to fluoresce. This equilibrium can be easily altered by adding free analyte (diuron), which competes with the conjugate to bind to the anti-diuron/monuron antibody. A reduction of anti-diuron/monuron antibody binding to the conjugate results in an increase in the binding of the anti-fluorescein antibody, which leads to a decrease in the fluorescence of the conjugate. The fluorescence is therefore a direct indicator of the state of equilibrium of the system and thus also the presence of free unconjugated analyte. The determination of an analyte based on this test principle does not require any washing steps. After the test components are mixed, the dynamic equilibrium is rapidly reached and the results can be obtained in less than 5 min by measuring the fluorescence of the fluorescein. We used this test principle for the determination of diuron, which was demonstrated for concentrations of approximately 5 nM.

Antibodies, Monoclonal↗

Research and development in biosensors.

Progress in biosensors has mainly been made by the improvement of the biological components and the implementation of microsystem technologies. Enzymes are still the most appropriate recognition elements because they combine high chemical specificity and inherent biocatalytic signal amplification. A breakthrough has been achieved in the application of membrane-integrated receptor systems for analyte recognition and signal transduction in biosensors. Sensor integration of RNA aptamers has been initiated, and the performance of fully synthetic molecularly imprinted polymers has been improved.

Antibodies↗

Operation of a miniature redox hydrogel-based pyruvate sensor in undiluted deoxygenated calf serum.

An amperometric sensor for the detection of pyruvate in biological fluids was formed by modifying the tip of a 0.25 mm gold wire with a layer of electrically "wired" recombinant pyruvate oxidase (POP). The sensor did not require O2 for its operation. The electroactive area of the tip of the microwire was increased by electrodeposition of platinum black. The POP was adsorbed on the platinum black and then "wired" with the cross-linked, subsequently deposited poly(4-vinylpyridine), part of the pyridine functions of which were complexed with [Os(bpy)2Cl](+/2+) and part quaternized with 2-bromoethylamine. In the resulting thin layer the POP was well "wired". When the electrode was poised at 0.4 V vs Ag/ AgCl, the sensitivity at pH 6 was 0.26 A cm(-2) M(-1) and the current increased linearly with the pyruvate concentration through the 2 x 10(-6) - 6 x 10(-4) M range. Thiamine diphosphate, flavin adenine dinucleotide, and MgCl2 were not required for the assay, but stabilized the stored enzyme electrode. Placement of a dialysis membrane (MWCO 3500) on the electrode alleviated the severe interference of ascorbate. In calf serum, the detection limit was 30 microM, suggesting that the electrode might be used in the continuous monitoring of pyruvate in hypoxic organs.

Animals↗

Development of a creatinine ELISA and an amperometric antibody-based creatine sensor with a detection limit in the nanomolar range.

Creatinine-specific antibodies have been generated and used for highly sensitive and specific immunochemical creatinine determinations. Creatinine was derivatized at N3 and coupled to KLH carrier protein. On the basis of this immunogen, monoclonal antibodies were developed by hybridoma technology. Antibodies from various clones have been characterized with BIAcore 2000 with respect to the dissociation constant and specificity. Antibodies of clone B90-AH5 exhibited the lowest dissociation constant (0.74 microM) and the highest specificity for creatinine and were chosen for the development of a competitive ELISA and an amperometric creatinine sensor. The creatinine sensor was constructed by fixing a creatinine-modified membrane on the top of a platinum working electrode which was then incorporated into a stirred electrochemical measuring cell. For creatinine determination the creatinine-containing sample was incubated with B90-AH5 and anti-IgG(mouse)-glucose oxidase conjugate and applied to the measuring cell. After a washing step glucose was added and the produced hydrogen peroxide was registered at Eappl = +600 mV vs Ag/AgCl. The measuring range was 0.01-10 microg/mL. The highest sensitivity for creatinine was achieved at 330 ng/mL (3 microM) and the lower detection limit at 4.5 ng/mL (40 nM). This is far below the relevant clinical range, which is 5-17 microg/mL (44-150 microM) and allows a reliable determination of very low creatinine concentrations in serum, where standard methods cannot be applied. After each measurement the sensor was regenerated with 10 mM HCl without any loss in binding activity.

Antibodies, Monoclonal↗

Enzyme kinetic assays with surface plasmon resonance (BIAcore) based on competition between enzyme and creatinine antibody.

A procedure is described which allows the characterization of enzyme by a hybrid approach using an enzyme and an antibody. The presented method is related to the affinity determination of antibodies by the 'affinity in solution' procedure for BlAcore. The antibody is used as an indicator for the concentration of substrate, which is also the antigen. A mixture of enzyme, substrate and antibody is incubated, and an aliquot of this solution is injected periodically into a flowcell containing immobilized substrate, which is bound by the antibody, but not cleaved by the enzyme. The chosen initial concentration of substrate inhibits the binding of antibody to the immobilized substrate by 90%. During the enzymatic reaction, increased amounts of antibody bind to the surface, as the substrate concentration is decreased. With this method, the cleavage of creatinine with creatinine iminohydrolase (6 mU/ml) was monitored for up to 11 h. A recently developed monoclonal antibody against creatinine was used as the indicating protein. For the calculation of enzyme activity, the signals were compared with a calibration curve for inhibition of antibody binding to the chip by creatinine in solution.

Aminohydrolases↗

A bienzyme electrode for L-malate based on a novel and general design.

The coimmobilization of a NAD(P) + -dependent dehydrogenase with salicylate hydroxylase (SHL, EC 1.14.13.1) in front of a Clark-electrode yields a flexible new design for dehydrogenase based biosensors. The feasibility of the approach has been tested with malic enzyme (MDH, EC 1.1.1.40) as the dehydrogenase, resulting in a novel L-malate sensor. It had substantial advantages over the biosensor approaches reported earlier: effective re-oxidation of NADPH by SHL yielded an extended linear range from 0.01 to 1.2 mmol 1(-1) L-malate and strongly reduced NADP+ -requirement (<0.025 mmol 1(-1)), while the working stability was increased to more than 30 days. The results obtained from six real samples showed a close correlation with the standard enzymatic method. The presented scheme with SHL and the Clark-electrode can be employed together with any NAD(P)+ -dependent dehydrogenase.

Biosensing Techniques↗

Determination of L-phenylalanine based on an NADH-detecting biosensor.

An enzyme carbon paste electrode containing three different enzymes was developed for the determination of L-phenylalanine. This sensor is based on the enzymatic/electrochemical recycling of tyrosinase in combination with salicylate hydroxylase and L-phenylalanine dehydrogenase (PADH). The enzymes salicylate hydroxylase and tyrosinase were coimmobilized first in a carbon paste electrode for the sensitive detection of NADH. The principle of the bienzyme scheme is as follows: the first enzyme, salicylate hydroxylase, converts salicylate to catechol in the presence of oxygen and NADH. The second enzyme, tyrosinase, then oxidizes the catechol to o-quinone, which is electrochemically detected and reduced back to catechol at the electrode at an Eappl = -50 mV vs Ag/AgCl. This results in an amplified signal due to the recycling of the catechol and o-quinone between tyrosinase and the surface of the electrode. Prior to adding PADH, the salicylate hydroxylase-tyrosinase carbon paste electrode was characterized in terms of its sensitivity to NADH, pH dependence, buffer composition, interferences, and stability. Interference from ascorbic acid and uric acid was found to be minimal. Human serum was used to investigate whether this bienzyme system was suitable for the detection of NADH in serum and blood samples. The sensitivity for NADH was increased by a factor of 33 times using the bienzyme amplification scheme (electroreduction of o-quinone at Eappl = -50 mV) as opposed to the salicylate hydroxylase single-enzyme system (at which catechol would have been oxidized at Eappl = +150 mV vs Ag/AgCl). The detection limit for NADH achieved by the bienzyme carbon paste electrode was 1 vs 100 microM for the single-enzyme carbon paste electrode. The salicylate hydroxylase-tyrosinase system was then coupled with phenylalanine dehydrogenase for L-phenylalanine determination. This multienzyme sensor was able to achieve a linear range of 20-150 microM and a detection limit of 5 microM for L-phenylalanine. The sensitivity is sufficient since the reference clinical range for L-phenylalanine is 78-206 microM.

Amino Acid Oxidoreductases↗

Production and characterization of monoclonal antibodies against urea derivatives.

A panel of monoclonal antibodies was generated against the urea-based hapten N-(2-N-chloroacetylaminobenzyl)-N'-4-chlorophenylurea as a tool for building up sensitive immune assays to detect urea derivatives and to screen them for catalytic antibodies (Abs). Eleven hybridomas were obtained that produced Abs reactive to the hapten. All Abs were of IgG class. Cross reactivities of the Abs to different haptens were examined, especially to a possible transition-state analog. Only four of the hybridomas (R2-DA10/F7, R2-GE7/H2, R2-HC2/A5, R2-HD6/F7) produced Abs crossreactive with the transition-state analog. From the 11 hybridomas, hybridoma B76-BF5 was chosen for further characterization. Compared to the other Abs, B76-BF5 showed the strongest binding and had a rather restricted specificity. These Abs could be used to build up a sensitive enzyme immunoassay for the detection of the hapten. All Abs were screened for crossreactivity with the pesticides monuron and diuron. No reactivity could be detected. In addition, the nucleotide sequences of the variable light and heavy chain genes of the similarly reactive Abs B76-BF5, B76-BB3, R2-DA10/F7, and R2-GA6/G3 were determined to clarify whether structure and binding specificity of these Abs showed any correlation.

Acetamides↗

Biosensors for food analysis.

Concerning speed, cost and on-line capabilities, biosensors offer attractive alternatives to existing methods for food analysis. They make monitoring and control of manufacturing processes possible. Furthermore, portable biosensors could be used for monitoring in manufacturing, retail and distribution of foods. An overview is given about existing biosensors for foodstuffs that could find applications in food industry.

Acids↗

Second generation biosensors.

Enzyme-membrane electrodes using glucose oxidase in combination with peroxide detection dominate in the field of laboratory analyzers for diluted samples. Using the same indication principle, extremely fast responding glucose sensors have been fabricated by covering thin metal electrodes with a porous enzyme layer. In the second generation auxiliary enzymes and/or co-reactants are coimmobilized with the analyte converting enzyme in order to improve the analytical quality and to simplify the performance. Following this line oxidizable interferences are suppressed by using a glucose oxidase/peroxidase complex which communicates with the electrode at a low working potential. Furthermore, fluctuations of pH or buffer capacity are ineffective when using a glucose oxidase/peroxidase layer covered fluoride FET in the potentiometric glucose determination. Enzymatic recycling of the analyte and/or accumulation of intermediates increase the sensitivity by several orders of magnitude. Inclusion of NAD bound to PEG in the glucose dehydrogenase layer allows a reagentless glucose measurement.

Biosensing Techniques↗

Electrochemical immunoassays.

Immunoassays (IA) use the specific antigen antibody complexation for analytical purposes. Radioimmunoassays (RIA), fluorescence immunoassays (FIA) and enzyme immunoassays (EIA) are well established in clinical diagnostics. For the development of hand-held devices which can be used for point of care measurements, electrochemical immunoassays are promising alternatives to existing immunochemical tests. Moreover, for opaque or optically dense matrices electrochemical methods are superior. Potentiometric, capacitive and amperometric transducers have been applied for direct and indirect electrochemical immunoassays. However, due to their fast detection, broad linear range and low detection limit, amperometric transducers are preferred. Competitive and noncompetitive amperometric immunoassays have been developed with redox compounds or enzymes as labels. This review will give an overview of the most frequently applied principles in electrochemical immunoassays. The potential of an indirect competitive amperometric immunoassay for the determination of creatinine within nanomolar range and the circumvention of the most serious problem in electrochemical immunoassays, namely regeneration, will be discussed.

Animals↗