Search PubMedSearch

Biomedical subjects

A Waggoner

Publications and source records attributed to A Waggoner.

5 recordsLinked to original sources

Sensitive detection of RNAs in single cells by flow cytometry.

A rapid and sensitive fluorescent in situ hybridization method has been developed to probe RNA contents of individual cells by flow cytometry. Fixed cells in suspension were hybridized with 5' end-fluorophore-labeled oligodeoxynucleotides complementary to defined regions of the RNA of interest and analyzed by flow cytometry. With this method, we monitored combinations of histone H4 mRNA, 18S rRNA and 28S rRNA levels in synchronized HeLa S3 cells by multicolor analysis. A fluorescence signal equivalent to 1800 copies of histone H4 mRNA per cell was detected with signal-to-background ratio of 5.4. If non-specific binding of the fluorophore-labeled probe can be reduced, as few as 100 copies of mRNA of the size of H4 could be detected in individual cells by flow cytometry.

Base Sequence

Flow cytometric analysis of lymphocyte phenotypes in bronchoalveolar lavage fluid: comparison of a two-color technique with a standard immunoperoxidase assay.

Characterization of lymphocytes in bronchoalveolar fluid has provided insight into the pathogenesis of many pulmonary diseases. Identification of lymphocyte phenotypes has become highly successful due to development of specific monoclonal antibodies and reliable methods for detecting labeled cells such as flow cytometry (FCM) and immunocytochemistry. FCM permits rapid screening of many cells, but this analysis may be confounded by heterogeneity in the size and granularity of the cells being evaluated. Such heterogeneity may lead to exclusion of cells of interest and inclusion of unwanted cells. Often peripheral blood leukocytes are used to define the gate for lung lymphocytes, but this gate may be inappropriate due to considerable variation in size and granularity of cells in bronchoalveolar lavage (BAL) fluid. Here we report an alternative method for generating a gate which employed fluorescence and side scatter signals to analyze lymphocyte subsets in BAL fluid by FCM. This gating technique avoids the pitfalls inherent in using the conventional lymphocyte gate to analyze lung cells. To validate this approach, we compared the results generated by this gate and those from the conventional forward/side light scatter gate to results derived from an immunocytochemical technique (ABC) that has been extensively employed in our laboratory to identify lymphocyte subsets in blood and lavage fluid. FCM tended to underestimate the proportions of T-cell subsets compared with ABC when the conventional gate was used. Counting only cells that stained with fluorescein-conjugated anti-CD45 antibody and that had side scatter properties of lymphocytes, however, resulted in excellent agreement between FCM and ABC. It appears that the CD45+/side scatter gate includes the vast majority of lymphocytes in BAL fluid while excluding most of the nonlymphoid cells that contaminate the conventional gate. It was this latter group of cells, and erythrocytes in particular, that led to the artificially low values for lymphocyte phenotypes in BAL fluid by FCM when the conventional lymphocyte gate was used. Although erythrocytes in BAL fluid may be eliminated by hypotonic lysis, this may also result in contamination of the conventional lymphocyte gate with nuclear debris and particulates from macrophages. Despite these advantages, the fluorescence/side scatter gate may not always be optimal for the evaluation of T lymphocytes if BAL fluid contains CD45+, nonlymphoid cells with low side light scatter. In these instances, additional antibodies such as anti-CD14 and anti-CD11 may be employed to determine the size of contaminant monocytic cells and neutrophils.(ABSTRACT TRUNCATED AT 400 WORDS)

Bronchoalveolar Lavage Fluid

Isopotentiality and an optical determination of series resistance in Limulus ventral photoreceptors.

1. Photoreceptor somas in the ventral rudimentary eye of Limulus polyphemus were impaled with three micropipettes. Two micropipettes were connected in a voltage-clamp circuit and the cells were stimulated by brief flashes. The third micropipette did not measure any significant deviations from the 'clamped' voltage during responses to the flashes, in several geometries of electrode placement, even for very bright flashes. Therefore using the described techniques there is no evidence for spatial non-uniformity of intracellular voltage in the soma of these photoreceptors. 2. A voltage-sensitive dye was used to monitor light-induced changes in membrane voltage while intracellular voltage was held clamped by a feed-back circuit. With a known series resistance connected between the bath and ground the dye recorded a light-induced change in membrane voltage. When there was no added series resistance, the light-induced change was smaller and often undetectable. From these data the naturally occurring series resistance was calculated to be less than or equal to 30 k omega. 3. From these measurements, as well as from calculations for a model spherical cell, we conclude that membrane potential can be controlled to within 2 mV using our micropipette 'point clamp' methods, for all but the brightest stimuli.

Animals

Optical probes of membrane potential.

There are two basically different mechanisms for the fluorescence and absorption changes of merocyanine, cyanine and oxonol dyes. The permeant dyes (cyanine and oxonol dyes, with delocalized charges) work by a potential-dependent accumulation mechanism. These dyes show large (up to 80%) fluorescence and absorption changes with suspensions of cells, and the changes are complete in seconds. The impermeant dyes (merocyanine dyes, with localized charges) and the permeant dyes also show optical changes that take place in fractions of milliseconds. The rapid optical changes are relatively small (less than or equal to 5 X 10(-3)) but can often be easily detected in experiments with single cells. The rapid, nonaccumulative, optical changes result from membrane-localized dye movements. Cyanine dye-absorption changes occur because of a potential-dependent partition of dye between the membrane and the adjacent aqueous region at the high dye-concentration side of the membrane. Dimers and larger aggregates are formed in the aqueous region during the change. Merocyanine dyes may also work by the same mechanism. DiS-C3-(5) is presently the best dye for measuring membrane potentials of cells, organelles, and vesicles in suspension, but several other cyanines work nearly as well (P.J. Sims, A.S. Waggoner, C.-H. Wang, J.F. Hoffman, Biochemistry 13:3315, 1974). For each system, the ratio of dye to membrane must be varied until the optimum fluorescence change is found. A separate calibration curve must be obtained for each system. For measuring fluorescence and/or absorption changes in single cells, merocyanine 540 and diBA-C4-(5) work well but produce some photodynamic damage with high intensity illumination. A rhodanine merocyanine (WW-375) gives very large absorption changes and does not damage tissue during strong illumination. As the mechanisms of the optical changes are worked out, it should be possible to design and synthesize more sensitive, less toxic dyes that are easier to calibrate. And, as the mechanisms of the optical changes are worked out, these dyes may be useful for studying the structure and dynamics of excitable membranes.

Anilino Naphthalenesulfonates