Search PubMed⌕ Search

Biomedical subjects

A W Nathan

Publications and source records attributed to A W Nathan.

At least 19 recordsLinked to original sources

Ventricular arrhythmia, Cheyne-Stokes respiration, and death: observations from patients with defibrillators.

OBJECTIVE: To determine whether ventricular arrhythmia related to nocturnal hypoxaemia during Cheyne-Stokes respiration (CSR) explains the observation that CSR is an independent marker of death in heart failure. DESIGN: Prospective, observational study. PATIENTS: 101 patients at high risk of clinical serious ventricular arrhythmia fitted with an implantable cardioverter-defibrillator (ICD). MEASUREMENTS: Patients were studied at baseline for CSR during sleep. Arrhythmia requiring device discharge was used as a surrogate marker for possible sudden cardiac death. RESULTS: 101 patients (42 with CSR) were followed up for a total of 620 months. Twenty six patients experienced 432 ICD discharge episodes. Twenty four (6%), 210 (49%), 125 (29%), and 73 (17%) episodes occurred across the time quartiles 0000-0559, 0600-1159, 1200-1759, and 1800-2359, respectively. Kaplan-Meier analysis showed a relative risk of 1 (95% confidence interval 0.5 to 2.2, p = 1) for device discharge in the CSR group. The average (SED) numbers of nocturnal ICD discharges per patient per month of follow up were 0.01 (0.01) and 0.04 (0.02) for patients with and without CSR, respectively (p = 0.6). CONCLUSION: These findings refute the proposition that CSR is related to heart failure death through nocturnal serious ventricular arrhythmia.

Aged↗

Effects of intravenous dofetilide on induction of atrioventricular re-entrant tachycardia.

OBJECTIVE: To assess the efficacy and safety of intravenous dofetilide in preventing induction of atrioventricular re-entrant tachycardia. DESIGN: A multicentre, open, dose ranging trial. Fifty one patients with electrically inducible atrioventricular re-entrant tachycardia were allocated to one of five doses of dofetilide (1.5, 3, 6, 9, and 15 microgram/kg), two thirds of the dofetilide dose being given over a 15 minute loading period and the remainder over a 45 minute maintenance period. MAIN OUTCOME MEASURE: Responders were defined as patients in whom dofetilide prevented reinduction of atrioventricular re-entrant tachycardia at the end of the infusion. RESULTS: Intravenous dofetilide had no effect on tachycardia inducibility at the two lower doses (1.5 and 3 microgram/kg) but prevented the reinduction of tachycardia at the three higher doses (6, 9, and 15 microgram/kg) at a rate of 36% (11/31). There was a clear relation between plasma dofetilide concentrations and efficacy (p = 0.009). In non-responders, dofetilide increased the cycle length of induced atrioventricular re-entrant tachycardia. Dofetilide increased the atrial and ventricular effective refractory periods, as well as the antegrade and retrograde effective refractory period of the accessory pathway. Treatment related side effects were reported in four patients, one with a new sustained incessant supraventricular tachycardia. CONCLUSIONS: Dofetilide shows promise as an agent for the prevention of atrioventricular re-entrant tachycardia in patients without structural heart disease.

Adolescent↗

Dissociation of pituitary-adrenal and catecholamine activation after induced cardiac arrest and defibrillation.

To avoid factors which confound attempts to characterize the neuroendocrine response to cardiac arrest, we studied the pituitary-adrenocortical and catecholamine responses to induced ventricular fibrillation (VF) and direct current cardioversion in 10 patients undergoing testing of 'implanted cardioverter defibrillator' devices under sedation. Plasma concentrations of epinephrine were increased 5 min after VF (from a mean basal of 0.39 (S.E.M. 0.09) to a peak of 0.632 (0.212) nmol litre-1; P < 0.05) but were unchanged at other times. Plasma concentrations of norepinephrine did not change at any time. Plasma concentrations of cortisol increased significantly at 10 min (from a mean of 367 (SEM 62) to 539 (64) nmol litre-1; P < 0.001) and remained increased 30 min after VF (470 (74) nmol litre-1; P < 0.05) but had returned towards baseline at 60 min, whereas plasma prolactin concentrations were increased at 5 min (from a mean of 224 (SEM 54) to 320 (63) mu. litre-1; P < 0.01) and remained increased until the end of the sampling period at 60 min (288 (65) mu. litre-1; P < 0.05). Concentrations of adrenocorticotrophic hormone (ACTH) (n = 5) tended to increase but this was not statistically significant. We conclude that a short period of cardiac arrest in lightly sedated humans activated the pituitary-adrenocortical axis but did not appear to stimulate catecholamine secretion. These findings raise questions about the nature and mechanisms of the neuroendocrine response to cardiac arrest.

Adrenocorticotropic Hormone↗

Recurrence of accessory pathway conduction after successful radiofrequency ablation: histological findings.

The histological findings from a patient with Wolff-Parkinson-White syndrome (right superior paraseptal accessory pathway) who underwent successful radiofrequency ablation and had recurrence of tachycardia one month later in the absence of overt pre-excitation are reported. Histology revealed three small, oval to circular shaped, whitish, smooth areas on the right endocardial surface, the one being situated at the atrial free wall, and the other two being at the ventricular aspect. A very small hole was present in the interventricular component of the membranus septum. The accessory pathway band passed to either side of the small hole albeit disrupted by fibrous tissue in places. These findings indicate that multiple applications may cause penetration of the myocardium, and to achieve success, complete disruption of the pathway at some point along its course is required. Recurrence of retrograde accessory pathway conduction can be explained with the impedance mismatch hypothesis.

Adult↗

Arrhythmia recognition strategies and hardware decisions for the implantable cardioverter-defibrillator--a review.

The avoidance of inappropriate shocks from the implantable cardioverter-defibrillator (ICD), together with its need to apply antitachycardia pacing to either atria or ventricles, demands considerable sophistication in the design of algorithms to interpret electrical or other cardiac signals in real-time. Methods based on rate and using single short-gap bipolar leads lack discrimination. Right ventricular electrogram morphology algorithms offer improvement but no universal algorithm exists; however, for any given patient an optimum algorithm of this type might be found. One improvement would be to provide atrial information in addition, by employing more than one electrode or a long-gap single bipolar lead. Alternatively, transducer signals could be included, once their efficacy and reliability have been improved. A different approach would be to use the much more sophisticated algorithms at present being tried with surface electrocardiograms. Integrated Circuit technology is reaching the point where this could be done but the requirement for exceptionally high reliability means that special system structures, such as a Memory Intensive Computer Architecture, may be required. When decisions on these approaches are to be made, it must also be remembered that ICDs will soon be implanted and programmed as a routine rather than a highly specialized procedure.

Algorithms↗

The role of cardioversion therapy in patients with implanted cardioverter defibrillators.

Stable ventricular tachycardias can be treated with pacing or electrical countershock. Use of pacing includes several advantages, but it is not always effective; when pacing is not effective, shocks can be used for cardioversion of the arrhythmia. Use of such shocks includes advantages and disadvantages, but generally they are well tolerated and form an important part of the treatment of patients with sustained ventricular arrhythmias.

Cardiac Pacing, Artificial↗

Clinical validation of a radionuclide detector to measure ejection fraction in critically ill patients.

The use of a new non-imaging nuclear probe (Cardioscint) capable of continuous online monitoring of left ventricular function is described in critically ill patients undergoing mechanical ventilation. Ejection fraction, measured by the Cardioscint, was compared with that measured by echocardiography. The mean difference was -1.1% (95% confidence interval -2.9 to +0.6%). Mean difference +/- 2 SD was +10.6 to -12.8% (95% confidence intervals +7.5 to 13.6% and -15.8 to -9.0%, respectively). Examples of fluid loading and inotropic support showed comparable changes in stroke counts measured by the Cardioscint and stroke index measured by thermodilution. The Cardioscint is a practical bedside method for continuous or repeated measurement of ejection fraction and for assessing the response to therapeutic interventions in critically ill patients.

Adult↗

Survey of the attitudes of British physicians to pacing.

OBJECTIVES: To assess how the opinions of cardiologists, physicians, and general practitioners on the indications for permanent pacing compare with published guidelines, and to determine whether resources, pacing experience, and position influence referral practices. DESIGN: Anonymous postal survey by questionnaire from St Bartholomew's Hospital, London and the King's Fund Institute, London. The questionnaire established the respondent's position, resources, and previous pacing experience. Eleven clinical and electrocardiographic situations were described and respondents were asked to decide on whether pacing was indicated. The responses received were compared with the guidelines provided by the 1984 American College of Cardiology/American Heart Association task force. PARTICIPANTS: The 630 members of the British Cardiac Society, 1370 randomly selected general physicians, and 2000 general practitioners. RESULTS: Patients with symptoms were more likely to be referred for pacing than symptom free patients regardless of underlying aetiology. In relatively symptom free patients the frequency with which pacing was recommended was low, even when it was unequivocally indicated on prognostic grounds. Failure to recommend pacing was unrelated to diagnostic facilities or referral difficulties. Respondents with pacing experience were more likely to recommend pacing. CONCLUSIONS: The physicians surveyed had a conservative approach towards recommending pacing. Most physicians were influenced predominantly by symptoms and the prognostic indications for pacing were not well appreciated.

Attitude of Health Personnel↗

North American Society of Pacing and Electrophysiology policy statement. The NASPE/BPEG defibrillator code.

A new generic code, patterned after and compatible with the NASPE/BPEG Generic Pacemaker Code (NBG Code) was adopted by the NASPE Board of Trustees on January 23, 1993. It was developed by the NASPE Mode Code Committee, including members of the North American Society of Pacing and Electrophysiology (NASPE) and the British Pacing and Electrophysiology Group (BPEG). It is abbreviated as the NBD (for NASPE/BPEG Defibrillator) Code. It is intended for describing the capabilities and operation of implanted cardioverter defibrillators (ICDs) in conversation, record keeping, and device labeling, and incorporates four positions designating: (1) shock location; (2) antitachycardia pacing location; (3) means of tachycardia detection; and (4) antibradycardia pacing location. An additional Short Form, intended only for use in conversation, was defined as a concise means of distinguishing devices capable of shock alone, shock plus antibradycardia pacing, and shock plus antitachycardia and antibradycardia pacing.

Defibrillators, Implantable↗

High-risk coronary angioplasty with elective intra-aortic balloon pump support.

Percutaneous transluminal coronary angioplasty was attempted with elective percutaneous intra-aortic balloon pump support in 21 patients (mean age 60 years, range 40-82; 18 males) with unstable angina (n = 2), multivessel coronary disease requiring multivessel angioplasty (n = 2), severe left ventricular dysfunction (ejection fraction 10-30%; n = 16) or ventricular fibrillation at diagnostic angiography (n = 1). Fourteen patients had 3-vessel disease (1 with vein grafts also diseased), 6 had 2-vessel disease and 1 had isolated left anterior descending disease. Twenty-five procedures were performed (one in 18 patients, two in 2 patients and three in one patient) on 42 lesions in 34 vessels/grafts. There was no angioplasty-related death. Successful dilatation was achieved in 38/42 lesions (90%) in 21/25 procedures (84%) without major complication. Three procedures were complicated: one by major coronary dissection without sequelae, one by haemodynamic deterioration due to distal occlusion and one by an unstable residual stenosis in the attempted vessel necessitating urgent bypass surgery. The only complication related to the intra-aortic balloon pump was local haematoma in 2 patients. In conclusion, elective intra-aortic balloon pump support may be safely used to stabilise high-risk patients undergoing coronary angioplasty, leading to a satisfactory primary success rate.

Adult↗

Effects of laser-generated tissue debris on aggregation of human platelets.

This study examined the effects of laser-generated tissue debris from thrombus, atheroma, and normal aorta on platelet aggregation. Debris supernatant and suspension from lased thrombus induced dose-related aggregation, maximal at 48 +/- 12% and 65 +/- 2%, respectively. Debris suspension from normal aorta induced maximal aggregation of 35 +/- 12%, but the debris from atheromatous aorta surprisingly had no effect on platelet aggregation. The debris particle count was in the range of 10(10) to 10(12) per liter. Aspirin, 0.2 and 2.0 mmol/L, only weakly inhibited the debris-induced aggregation, and heparin up to 10 U/ml was ineffective. However, iloprost reduced aggregation to 40 +/- 11% of control at 0.3 ng/ml, and totally abolished it at 3 ng/ml. Soluble and particulate laser-generated debris from vascular tissue and thrombus may cause platelet aggregation in vitro. This may have implications for laser coronary angioplasty.

Aged↗

The right ventricular outflow tract as an alternative permanent pacing site: long-term follow-up.

The long-term characteristics of the right ventricular outflow tract have been assessed as an alternative permanent pacing site to the right ventricular apex. Thirty-three consecutive patients requiring ventricular pacing were randomized to be paced from one of the two sites. Pacing was performed using a screw-in lead, and a programmable pacemaker was used to facilitate threshold testing. There was no significant difference in the lead positioning time or any acute implant measurement (e.g., threshold at 0.5 msec 0.4 +/- 0.2 V for both sites, P = 0.99). Chronic measurements were also comparable during follow-up (mean 73 months) with a mean threshold at most recent follow-up of 0.15 +/- 0.2 msec (apex) and 0.13 +/- 0.21 msec (outflow tract) at 5 V, P = 0.81. There was only one pacing related complication, a lead dislodgment (outflow tract) in a pacemaker twiddler. Overall, both sites were highly satisfactory.

Aged↗