Search PubMed⌕ Search

Biomedical subjects

A Vinegar

Publications and source records attributed to A Vinegar.

36 records · Page 2Linked to original sources

The pathogenesis of experimental pulmonary histoplasmosis. Correlative studies of histopathology, bronchoalveolar lavage, and respiratory function.

A murine model of acute pulmonary histoplasmosis was employed to study the pathogenesis of the disease process by means of histopathology, bronchoalveolar lavage, and respiratory function tests. These studies were performed on C57BL/6 mice from 8 h to 8 wk after intranasal inoculation of 10(5) yeast forms of Histoplasma capsulatum and on age-matched control animals that received saline only. At Week 1, the histopathology was characterized by subacute inflammation consisting of polymorphonuclear leukocytes (PMN), lymphocytes, and macrophages that infiltrated the interstitium around small bronchioles and adjacent alveoli. At Weeks 2 and 4, the infiltrates were comprised predominantly of lymphocytes and macrophages; noncaseating granulomas were present at Week 2. Aggregates of lymphoid cells were prominent along the bronchial tree and in perivascular distribution. Those in close contact with bronchiolar epithelium resembled hyperplastic bronchus associated lymphoid tissue. Quantitative studies of cells in the BAL fluid revealed a large influx of PMN at Week 1 with return to normal range by Week 2. At this time there was a significant (p less than 0.02) increase in lymphocytes that persisted through Week 8, although histopathologic changes were minimal in lung at this time. A significant decrease in the DLCO/TLC at Week 2 in association with a normal vital capacity indicated impairment of respiratory function secondary to the alveolitis induced by H. capsulatum infection rather than a reduction of lung volume. This model offers promise for additional correlative studies of lymphocyte subsets in lung tissue and alveolar spaces as well as of the functions subserved by these respective populations.

Animals↗

Morphology of tracheal and bronchial epithelium and type II cells of the peripheral lung of the guinea pig after inhalation of toluene diisocyanate vapors.

Toluene diisocyanate (TDI), a polymerizing agent used in production of plastics, can cause airways disease in some exposed individuals. Using guinea pigs as a model, the response of the airways and the type II cells of the peripheral lung was monitored morphologically and morphometrically after exposure to TDI vapors at 30 ppb, 260 ppb, and 3100 ppb. The two low doses of TDI caused little change in airways epithelium. There was no gross inflammatory cell infiltrate, however, surface infoldings and intracellular ciliated cysts increased in numbers. Animals exposed to 3100 ppb TDI 4 h/day for 5 days, sustained considerable damage to the epithelium, and stratified nonkeratinizing cells lined the airways until one week after exposure. Polymorphonuclear leukocytes were present in the early period after exposure. Increased numbers of eosinophils were present between one and two weeks following exposure. Mitoses in the epithelium were common during recovery. In the peripheral lung, though a modest subjective increase in the number of type II cells was seen after 3100 ppb TDI, the volume density of type II cells, and organellar components (lamellar bodies, mitochondria, cisternal bodies) did not change significantly after any exposure level of TDI.

Animals↗

Effect of exposure to 500 ppm sulfur dioxide on the lungs of the ferret.

Male ferrets (Mustela putorius furo) were exposed 3 h/day, 3 days/week for 12 weeks to 500 ppm SO2. Determinations were made of airway responsiveness by producing histamine dose-effect curves. Lung tissues were fixed and studied by light and electron microscopy. Epithelial cells of the trachea and bronchus were most affected. Lesions observed included changes in ciliated cells, edema and cell infiltration. The most responsive animals to histamine were 2 from the exposed group. Nasal discharge and dried mucus were observed after 3 days of exposure. Coughing was first noted after 2 weeks. Results favor further pursuit of the use of the ferret as a model for human airways disease.

Animals↗

Pulmonary physiology of the ferret and its potential as a model for inhalation toxicology.

Physiological measurements were made from anesthetized, tracheotomized, supine male ferrets. Six animals weighing 576 +/- 12 g, had tidal volumes (Vt) of 6.06 +/- 0.30 ml, respiratory frequencies (f) of 26.7 +/- 3.9 min(-1), dynamic lung compliance (CDYN) of 2.48 +/- 0.21 ml cmH2O(-1), pulmonary resistance (RL) of 22.56 +/- 1.61 cmH2O L(-1) sec. Pressure-volume curves from nine ferrets (including the above six) revealed almost infinitely compliant chest walls so that lung and total respiratory system curves were essentially the same. Total lung capacity (TLC) (89 +/- 5 ml) and functional residual capacity (FRC) (17.8 +/- 2.0 ml) were determined by gas freeing the lungs in vivo. The TLC of these ferrets was about the same as in 2.5 kg rabbits. Maximum expiratory flow-volume curves showed peak flows of 10.1 vital capacities (VC) sec(-1) at 75% VC and flows of 8.4 and 5.4 VC sec(-1) at 50% and 25% VC. No particular problems were encountered in making these measurements using conventional techniques available in laboratories capable of making pulmonary function measurements on rats and guinea pigs. Preliminary studies of airways reactivity showed equal increases in pulmonary resistance in response to equivalent challenges of aerosolized carbachol and histamine. Light and electron microscopic studies showed that the airways of ferrets are even more like those of humans than are the dog's. The ease with which physiological measurements can be made and the favorable aspects of the lung anatomy indicate the ferret may be more useful, as well as less expensive, than the dog for use in studies of pulmonary physiology and inhalation toxicology.

Aerosols↗

Respiratory mechanics of a small carnivore: the ferret.

The ferret, Mustela putorius furo, is a small relatively inexpensive carnivore with minimal housing requirements. Measurements were made from anesthetized tracheotomized supine males. Values obtained during tidal breathing for six animals (576 +/- 12 g) were as follows: tidal volume, 6.06 +/- 0.30 ml; respiratory frequency, 26.7 +/- 3.9 breaths min-1; dynamic lung compliance, 2.48 +/- 0.21 ml cmH2O-1; pulmonary resistance, 22.56 +/- 1.61 cmH2O . l-1 . s. Pressure-volume curves from nine ferrets revealed almost infinitely compliant chest walls so that lung and total respiratory system curves were essentially the same. Total lung capacity (TLC, 89 +/- 5 ml) and functional residual capacity (17.8 +/- 2.0 ml) were determined by gas freeing the lungs in vivo. The TLC of these ferrets is about the same as in 2.5-kg rabbits. Maximum expiratory flow-volume curves showed peak flows of 10.1 vital capacities (VC) . s-1 at 75% VC and flows of 8.4 and 5.4 VC . s-1 at 50 and 25% VC.

Animals↗

Pulmonary defense mechanisms in Boa constrictor.

We studied aerosol deposition and the response to inhaled particles and irritants in lungs of Boa constrictor. Snakes which breathed submicrometric particles radiolabeled with 99mTc retained 41.4 +/- 9.9% of the aerosol in the trachea, 42.5 +/- 8.8% in the anterior faveolar regions, and 8.7 +/- 4.1% in the posterior saccular regions of the lungs. Low activity recovered in the gastrointestinal tract over a 5-h period following aerosol exposure indicated slow clearance of inhaled particles. In contrast to mammalian lungs, there are no macrophages resident on the surface of boa lungs, and uningested particles persist for up to 4 days without being phagocytized. Particles and irritant stimuli (Fe2O3, endotoxin, and N-formylmethionylphenylalanine) elicited only eosinophilic granulocytes that were not phagocytic. The numbers of these cells peaked at 24 h following exposure and declined gradually over the next 7 days. Lavage fluid from stimulated snake lungs contained many large lamellar figures continuous with tubular myelin, a form of surfactant. Very little of this material was recovered from control lungs. Response to inhaled particles and lung injury in boas increased surfactant release, elicited eosinophilic granulocytes, but did not recruit phagocytic mononuclear cells.

Animals↗

Dynamic mechanisms determine functional residual capacity in mice, Mus musculus.

Awake mice (22.6--32.6 g) were anesthetized intravenously during head-out body plethysmography. One minute after pentobarbital sodium anesthesia, tidal volume had fallen from 0.28 +/- 0.04 to 0.14 +/- 0.02 ml and frequency from 181 +/- 20 to 142 +/- 8. Functional residual capacity (FRC) decreased by 0.10 +/- 0.02 ml. Expiratory flow-volume curves were linear, highly repeatable, and submaximal over substantial portions of expiration in awake and anesthetized mice; and expiration was interrupted at substantial flows that abruptly fell to and crossed zero as inspiration interrupted relaxed expiration. FRC is maintained at a higher level in awake mice due to a higher tidal volume and frequency coupled with expiratory braking (persistent inspiratory muscle activity or increased glottal resistance). In anesthetized mice, the absence of braking, coupled with reductions in tidal volume and frequency and a prolonged expiratory period, leads to FRCs that approach relaxation volume (Vr). An equation in derived to express the difference between FRC and Vr in terms of the portion of tidal volume expired without braking, the slope of the linear portion of the expiratory flow-volume curve expressed as V/V, the time fraction of one respiratory cycle spent in unbraked expiration, and respiratory frequency.

Anesthesia↗

A technique for measuring frequency response of pressure, volume, and flow transducers.

A device and methodology is presented for testing the frequency response of pressure, volume, or flow transducers. Also reported are responses of selected transducers of all three types over the range of 2--120 Hz. Several pressure transducers tested had good frequency response when connected to the test system with a minimum of interconnecting fittings; others did not. Use of additional connectors degraded the response as did the addition of air-filled catheters. The frequency response of the pneumotachometers tested were influenced largely by the response characteristics of the associated pressure transducer and interconnecting fittings. These results emphasize the need to test the response characteristics of any transducer with specific connectors and fittings that are to be used to make the actual measurements of pressure, volume, or flow.

Mathematics↗

Biochemical and physiologic changes in lungs of rats exposed to a cadmium chloride aerosol.

The purpose of this study was to examine the in vivo effects of acute exposure to a cadmium chloride aerosol on the activity of pulmonary enzymes and selected physiologic parameters that are altered by exposure to oxidant agents. Male rats were exposed for 1 hour to 0.5 per cent aerosol of cadmium chloride. At 1,5, and 11 days after exposure to cadmium chloride, exposed rats compared to control rats (data expressed as per cent of control values) had lung-to-body weight ratios of 192, 174, and 140 per cent; lung glucose-6-phosphate dehydrogenase activities of 90, 107, and 135 per cent; lung superoxide dismutase activities of 96, 101, and 132 per cent; tidal volumes of 62, 63, and 89 per cent; respiratory frequencies of 170, 145, and 108 per cent; and lung weight-specific static deflation volumes at 30 cm water of 30, 13, and 31 per cent. A zero-order clearance of cadmium from whole lung was observed, with a half-time of 27.4 days. Light microscopic examination of lung tissue revealed initial pulmonary edema on day 1 that progressed to interstitial pneumonitis on day 5, with some recovery by 11 days after exposure. The cadmium induced biochemical, physiologic, and pathologic alterations were similar to the responses observed in lungs of rats exposed to a wide variety of pulmonary irritants; thus, the changes observed may represent a nonspecific response to tissue injury.

Aerosols↗

Thermoregulation in a brooding female Indian python, Python molurus bivittatus.

At varying environmental temperatures, measurements of body temperatures and gas exchange of a female Indian python (Python molurus bivittatus) show that during the brooding period this animal can regulate its body temperature by physiological means analogous to those in endotherms. Ambient temperatures below 33 degrees C result in spasmodic contractions of the body musculature with a consequent increase in metabolism and body temperature.

Animals↗

Simulated blood levels of CF3I in personnel exposed during its release from an F-15 jet engine nacelle and during intentional inhalation.

Of the agents under consideration for protecting unoccupied areas from fire, CF3I (trifluoroiodomethane) has physicochemical properties that give it potential as a "drop-in" replacement for halon 1301. One of the issues concerning the use of CF3I is the potential hazard to ground crews should an inadvertent discharge occur while workers are in or near an engine nacelle. A discharge test of CF3I was conducted on an F-15A jet to record CF3I concentration time histories at locations near the aircraft. The conditions of the discharges simulated an inadvertent ground discharge with the engine nacelle doors open and also with the doors closed. The use of three types of gas analysis instrumentation allowed gas sampling from several locations during the discharge tests. Concentrations measured at selected sensor locations were used as the input to a physiologically based pharmacokinetic model to simulate blood levels that would be attained by individuals inhaling CF3I at sensor locations. Blood levels reached during these exposures were compared with the blood level associated with the lowest observable adverse effect level (LOAEL) for cardiac sensitization to evaluate the possibility of safe egress. The highest blood concentrations simulated were twice the target blood concentration associated with cardiac sensitization. However, simulated blood concentrations of subjects who actually inhaled CF3I reached levels that were 100 times the target level without reported adverse effect. Thus, actual human data may supersede the use of the cardiac sensitization LOAEL obtained from animal studies.

Aircraft↗

Hepatotoxicity in guinea pigs following acute inhalation exposure to 1,1-dichloro-2,2,2-trifluoroethane.

Groups of 10 male Hartley guinea pigs were exposed to 3.0, 2.0, 1.0, or 0.1% (v/v) 1,1-Dichloro-2,2,2-trifluoroethane (HCFC-123) or 1.0% (v/v) halothane by inhalation for 4 hr. A sixth group of 10 guinea pigs received only air. All animals were sacrificed 48 hr postexposure. Gross and histopathologic examination of the liver, heart, and kidney and routine hematology and clinical chemistry analyses [including isocitrate dehydrogenase (ICDH)] were done on all guinea pigs. Lesions related to HCFC-123 and halothane exposure were limited to the liver and included centrolobular vacuolar (fatty) change, multifocal random degeneration and necrosis, and centrolobular degeneration and necrosis. These lesions were observed in 90-100% of the exposed animals and were absent in the air-only controls. There was significant individual animal variation in susceptibility to both HCFC-123 and halothane, resulting in a spectrum of histologic lesions and clinical chemistry values within each exposure group. Alanine aminotransferase, aspartate aminotransferase, and ICDH were the most significant predictors of hepatocellular damage. Similarities in the response between halothane and HCFC-123 in this guinea pig model suggests that humans susceptible to halothane-induced hepatitis may be susceptible to HCFC-123 by a common mechanism of toxicity.

Administration, Inhalation↗

A physiologically based pharmacokinetic model for chloropentafluorobenzene in primates to be used in the evaluation of protective equipment against toxic gases.

Chloropentafluorobenzene (CPFB) has been proposed as an innocuous simulant for the uptake of toxic gases. Exposure to CPFB in a training exercise could be inferred afterwards from a measurement of CPFB in expired breath. To understand the relationship between exposure and measurement, we have developed a physiologically-based pharmacokinetic (PB-PK) model for CPFB in primates. To test the model, inhalation exposures were conducted on anesthetized rhesus monkeys. CPFB concentration in expired breath was measured during and after exposure. Simulations of CPFB uptake and clearance agreed with experimental measurements in seven of eight monkeys. A human version of the model was used to simulate exposures consisting of a single breath or a few breaths. By showing a measurable CPFB concentration in expired breath after several hours of clearance, simulations with the human model indicated the suitability of CPFB as a simulant for toxic gases.

Animals↗