Search PubMed⌕ Search

Biomedical subjects

A Villani

Publications and source records attributed to A Villani.

At least 37 records · Page 2Linked to original sources

Clinical value of blood pressure variability.

Blood pressure (BP) is known to continuously fluctuate over time and both the amplitude and frequency of these changes have been reported to be clinically relevant. Indeed, it has been shown that the occurrence of pronounced BP changes at the time of the physician's visit may introduce errors in the diagnosis of hypertension and in the assessment of the efficacy of antihypertensive treatment. Moreover, several studies have provided evidence that the end organ damage of hypertension is not only more closely related to 24h average BP values than to casual BP readings, it is also significantly and independently related to the degree of BP variability during the day and night. Results from a recent follow-up study support the possibility that the degree of BP variability may also have prognostic relevance in hypertensive patients. Recent progress in technology has offered us non-invasive techniques for the assessment of beat-to-beat finger blood pressure variability and for the detailed quantification of all its frequency components from the fastest to the slowest ones. Their role as additional surrogate endpoints in essential hypertension needs to be addressed in future studies.

Blood Pressure↗

[Anesthesiologic management of susceptible children at risk for malignant hyperthermia].

In order to prevent malignant hyperthermia (MH) in children, the authors are currently using a perioperative anaesthetic protocol. In vitro contracture tests with halothane and caffein are performed in selected patients: those with previous signs suggestive of MH, but not severe enough for a definite diagnosis; those with susceptibility to MH in their relatives; those affected by myopathies or other disorders very frequently associated with MH. Even though CK should be considered an unreliable predictor of MH susceptibility, trigger agents are avoided in children with high and constant CK levels. However, prophylactic dantrolene is never employed. In this way, over the last decade no episodes of classic malignant hyperthermia in a large number of children submitted to anaesthesia (more than 50,000) have been observed.

Anesthesia, General↗

Evaluation of methacholine dose-response curves by linear and exponential mathematical models: goodness-of-fit and validity of extrapolation.

Several models have been proposed to analyse dose-response curves recorded in bronchoprovocation challenge tests. The aims of the present work were: 1) to investigate which model (linear vs exponential) and which minimization method (trials and errors vs Levenberg-Marquardt) gives better results in terms of data interpolation (goodness-of-fit); and 2) to verify the validity of extrapolation by comparing forced expiratory volume in one second (FEV1) observed after 4 mg methacholine with values extrapolated after truncation of the curves at 2 mg. For these purposes, methacholine dose-response curves were obtained in 832 subjects from a random population sample, as part of the European Community Respiratory Health Survey (ECRHS) in Italy. Methacholine was inhaled up to a maximum dose of 6 mg by dosimeter technique. The coefficient of determination (r2) was significantly higher with the exponential model (0.81 +/- 0.22; mean +/- SD) than with the linear model (0.69 +/- 0.27). With both models, extrapolated values were usually lower than observed values. As a consequence, a 20% fall in FEV1 with respect to postsaline FEV1 was observed in only 24% and 21% of the tests, where a 20% fall had been predicted, respectively, according to the linear and exponential model. In conclusion, exponential models are better than linear models with respect to data interpolation of methacholine dose-response curves. However, they are worse with respect to extrapolation to higher doses. With any model, extrapolation of dose-response curves by one doubling-dose should be avoided.

Adult↗

Bronchoalveolar lavage studies in children without parenchymal lung disease: cellular constituents and protein levels.

We evaluated bronchoalveolar lavage fluid (BAL) for cellular constituents, concentration of total protein (TP), albumin (AL), fibronectin (FN), and hyaluronic acid (HA) in 16 children aged 2-32 months without pulmonary inflammatory or parenchymal disease to establish reference values. We compared our data to those reported in older children and in normal adult volunteers. BAL results were obtained simultaneously from the right middle lobe and the lingula. Results indicated that children younger than 3 years of age had a higher number of cells/mL than older children and adults (59.9 x 10(4) vs. 17.6 x 10(4) and 12 x 10(4)). Differential cell count revealed that the percentages of alveolar macrophages (AM), lymphocytes (LYM), and eosinophils (EOS) were similar to those obtained in older children and in adults, whereas the percentage of neutrophils (NEU) was higher in younger children (NEU 5.5 vs 1.6 and 1.2%, respectively) than in older children and adults. The latter difference was even greater in infants under 12 months of age (NEU 7.6%). The concentrations of TP, AL, FN, and HA in children's BAL samples were compared to values reported for adults. There were no differences between infants and children 13-32 months of age or normal adults. BAL fluid obtained simultaneously from the middle lobe and lingula were not significantly different. In conclusion, this is the first report on BAL values (cellular and noncellular constituents) in children younger than 3 years. The results may be used as reference values for further studies in children with parenchymal lung disease in this age group.

Adult↗

Lack of placebo effect on ambulatory blood pressure.

Several studies have reported that, at variance with clinic blood pressure, ambulatory blood pressure is not reduced by treatment with placebo. However, this evidence has usually been obtained in small groups of subjects and no data are available from a larger sample of patients. To address this issue we have analyzed data from 116 outpatients involved in placebo-controlled studies on antihypertensive treatment. The patients were studied before and at the end of a 6- to 8-week period of placebo. In all patients, blood pressure was measured by sphygmomanometry and over the 24 h by automatic ambulatory monitoring. Administration of placebo was accompanied by a significant reduction in systolic and diastolic clinic blood pressure (-5.3 +/- 1.1 and -4.4 +/- 0.6 mm Hg, respectively; P < .01), but not in 24-h, daytime and nighttime blood pressure. Hourly systolic and diastolic blood pressure profiles were virtually superimposable in the two different periods, except for the first 4 h, in which systolic blood pressure was slightly but significantly lower during than before placebo (149.5 +/- 1.2 v 146.4 +/- 1.2 mm Hg; P < .05). These results provide a large database indicating that 24-h average blood pressure is not reduced by placebo, thus it is not necessary to include a placebo control group in antihypertensive drug studies in which ambulatory blood pressure monitoring is employed. A small placebo effect occurs, however, in the first hours of ambulatory monitoring. This may lead to a slight overestimation of the peak blood pressure effect of a drug and an underestimation of its trough-to-peak ratio if placebo correction of the data is not made or if the first part of ambulatory blood pressure monitoring is not excluded from data analysis.

Blood Pressure↗

Permanent blood pressure control over the 24 h by trandolapril.

Noninvasive ambulatory blood pressure monitoring (ABPM) has proved to be an innovative tool for the assessment of the efficacy of antihypertensive drugs. It enables evaluation of the magnitude of the drug-related blood pressure fall and also of the duration of this effect throughout 24 h. Moreover, ambulatory blood pressures have advantages compared to office blood pressure: they are not affected by the white coat effect occurring at the time of the doctor's visit, are devoid of a placebo effect, are more reproducible than occasional clinic measurements, and may yield important information on the prognosis of hypertensive patients. Ambulatory blood pressure recordings were used to test the antihypertensive effect of a novel angiotensin converting enzyme, trandolapril, in 62 mild to moderate essential hypertensive outpatients. After a 4 week wash-out, period, patients were randomized to 2 mg trandolapril or placebo for 6 weeks. A 4-week wash-out period was scheduled at the end of the treatment period. Ambulatory blood pressure recordings were performed at the end of each period, starting in the morning. Trandolapril (n = 31) significantly reduced 24 h systolic and diastolic blood pressure as compared to pre- and posttreatment periods and to placebo (n = 17). The reduction involved both the daytime and nighttime blood pressure values and was evident also in the last hours of the recording, the trough-to-peak ratio being 0.6 for systolic and 0.7 for diastolic blood pressure. Thus, trandolapril at a dose of 2 mg once daily is an effective long-lasting antihypertensive drug.

Adult↗

Blood pressure reduction and end-organ damage in hypertension.

VALUE OF AMBULATORY BLOOD PRESSURE MONITORING: Studies that have used ambulatory blood pressure monitoring techniques have shown that the average 24-h or daytime blood pressure values are more closely related to the end-organ damage associated with hypertension than are isolated office readings. IMPORTANCE OF BLOOD PRESSURE VARIABILITY IN PROGNOSIS: More recently, blood pressure variability, measured as the overall 24-h blood pressure standard deviation, has been shown to have a significant relationship to end-organ damage in hypertensive patients. The potential clinical relevance of blood pressure variability has been strengthened in a recent prospective study. The possible prognostic value of blood pressure variability has practical implications for antihypertensive treatment; it may mean, for example, that the optimal antihypertensive drug should reduce not only the mean 24-h values but also the degree of fluctuation in blood pressure. This is more likely to occur with long-acting drugs, which induce a more balanced reduction in blood pressure throughout the 24 h. USE OF THE TROUGH:PEAK RATIO: A proposed measure of a balanced 24-h blood pressure effect is the trough:peak ratio of the blood pressure fall. This ratio can be obtained by clinic blood pressure measurements but ambulatory blood pressure monitoring offers some distinct advantages. One of these advantages is that by revealing the possibility of an excessive fall in blood pressure at the time of the peak effect or an uncontrolled rise at the trough, ambulatory monitoring can also reveal the possible impact of pharmacological treatment on 24-h blood pressure variability.

Antihypertensive Agents↗

Respiratory syncytial virus lung infection in infants: immunoregulatory role of infected alveolar macrophages.

Thirteen previously healthy children with acute onset of severe lower respiratory tract signs and symptoms underwent bronchoscopy and bronchoalveolar lavage (BAL) for diagnostic purposes. BAL samples were assessed for viral, bacterial, mycobacterial, and fungal cultures. Cytospin preparations of BAL cells were assessed for expression of respiratory syncytial virus (RSV), HLA-DR, interleukin-1 beta, and tumor necrosis factor proteins. Purified alveolar macrophages from 2 RSV-infected children were assessed for viral replication. Three children had bacterial pneumonia and 6 were infected with RSV. BAL cells from RSV-infected children demonstrated viral protein expression. Alveolar macrophages were the predominant cell type recovered by BAL and demonstrated coexpression of RSV, HLA-DR, interleukin-1 beta, and tumor necrosis factor proteins. Purified alveolar macrophages from 2 RSV-infected children replicated RSV by infectious center assays. Thus, alveolar macrophages are infected by RSV in vivo and coexpress potent immunomodulatory molecules that potentially regulate the local immune response or lung injury due to this virus.

Bronchoalveolar Lavage Fluid↗

Restricted replication of respiratory syncytial virus in human alveolar macrophages.

The cellular factors that regulate infection and replication of respiratory syncytial virus (RSV) in human alveolar macrophages were examined. RSV-exposed alveolar macrophages demonstrated a time-dependent expression of viral glycoproteins, maximal by 24 h post-infection resulting in infection of approx. 38% of the cells. Essentially all (33%) of these freshly isolated alveolar macrophages replicated RSV as shown by infectious centre assays. This RSV-permissive subpopulation of alveolar macrophages consisted primarily of major histocompatibility class II-expressing cells as determined by fluorescence-activated cell sorting. Re-infection of alveolar macrophages did not significantly alter the number of cells infected or capable of replicating RSV. However, in vitro differentiation of alveolar macrophages prior to infection resulted in a significant (P < 0.05), time-dependent decrease (approx. sevenfold) in the number of cells that replicated virus. The mechanism by which cellular differentiation restricted RSV replication is unknown. Production of defective interfering particles did not account for this decrease. Alveolar macrophages infected with RSV produce a variety of cytokines potentially contributing to this restricted viral replication. Pretreatment with several of these cytokines did not affect viral infection or replication. However, tumour necrosis factor (TNF alpha) significantly (P < 0.05) decreased viral replication but only by 30 to 60%. Thus RSV replication is reduced by in vitro differentiation of alveolar macrophages and, to a lesser degree, by pretreatment with TNF.

Adult↗

Intra-hospital transport of the anaesthetized patient.

This study evaluated the anaesthetic management of 20 patients, undergoing intra-operative radiation therapy for pancreatic or rectal tumours. Patients with a re-approximated surgical incision were transferred from the operating room to the radiotherapy department while still under anaesthesia. The risks of such transport as well as guidelines for the patient's care during this phase are examined. The results of this study indicate that in order to transport anaesthetized patients safely it is necessary to ensure stable cardiovascular, respiratory and metabolic conditions prior to their transfer. It is also important to guarantee adequate analgesia and to establish appropriate monitoring during transport.

Aged↗

[Anesthesia in thymectomy. Experience with 115 cases].

The authors have conducted a retrospective study on 115 patients with myasthenia gravis undergoing transsternal or transcervical thymectomy at the Policlinico A. Gemelli of Rome in the period June 1984- to June 1991. A prolonged postoperative mechanical ventilation immediately and a few days following surgery was required respectively in 7 and 3 patients, while atelectasia and broncopneumonia have developed in 10 patients. No relationship could be established between the incidence of respiratory complications and factors such as preoperative symptomatology and treatment anesthetic agents, the surgical approach to the thymus and thymic pathology. However a significantly greater postoperative morbidity has been observed in the group of patients receiving suxametonium as compared to the patients receiving non-depolarizing muscle relaxants. Vecuronium and atracurium very frequently allowed ad adequate resumption of spontaneous respiration after anesthesia and made possible a safe early extubation of patients before leaving the operating room. The authors also stressed that all patients, irrespective of their clinical conditions, must be transferred after thymectomy. Oto the surgical ICU where anticholinesterase therapy can be safely restarted and cardiorespiratory status carefully monitored.

Adolescent↗

Noninvasive automatic blood pressure monitoring does not attenuate nighttime hypotension. Evidence from 24 h intraarterial blood pressure monitoring.

Automatic ambulatory blood pressure monitoring makes use of repeated cuff inflations throughout the day and night. This may interfere with the cardiovascular effects of sleep and thus alter the 24 h blood pressure profile. The possibility that intermittent automatic blood pressure measurements prevent nocturnal hypotension was examined in 17 mild or moderate essential hypertensive patients in whom blood pressure was recorded intraarterially for 48 h by the Oxford technique. During the first or the second 24 h period, blood pressure was also monitored noninvasively by the SpaceLabs (Redmond, WA) 5300 (n = 10) and by the Sandoz Pressure System SPS 1558 (Lavanchy Electronique, Prilly, Switzerland) (n = 7) devices, automatic measurements being performed at 15 min intervals during the day and at 30 min intervals during the night. Separate computer analysis of 24 h intraarterial tracings obtained in absence and in concomitance of contralateral automatic blood pressure monitoring showed that the occurrence of automatic measurements had not interfered with the day-night intraarterial blood pressure and heart rate profiles. Thus the frequent cuff inflations that characterize automatic blood pressure monitoring do not attenuate nighttime hypotension and bradycardia. This finding supports use of the noninvasive approach in assessing blood pressure profiles.

Adult↗

Respiratory syncytial virus infection of alveolar macrophages in adult transplant patients.

Pulmonary epithelial cells are thought to be the primary cellular targets for infection by respiratory syncytial virus (RSV) in vivo. To determine whether other pulmonary cells are infected by RSV, bronchoalveolar lavage cells from six adult transplant patients, four of whom had acute RSV infection, were examined by in situ immunohistochemistry to identify infected lung cells. Both alveolar macrophages and epithelial cells were infected with RSV in vivo. At the single-cell level, three-color immunofluorescent studies revealed that both RSV-infected epithelial cells and alveolar macrophages expressed Class II molecules of the major histocompatibility complex, but only the alveolar macrophage coexpressed interleukin-1 beta. Paraformaldehyde-fixed bronchoalveolar lavage cells from RSV-infected but not uninfected patients induced a marked proliferative response by cloned T cells indicating that in vivo infected cells expressed bioactive interleukin-1. Together, these studies indicate that the alveolar macrophage may have a critical role in the lung immune response to RSV.

Adult↗

Ambulatory blood pressure monitoring.

This paper reviews the evidence that, in patients with hypertension, end-organ damage correlates more closely with blood pressure values obtained by ambulatory blood pressure monitoring than with those obtained by conventional sphygmomanometry. However, ambulatory blood pressure monitoring is not suitable for routine use in the clinical setting because of a lack of standard reference values and data regarding the prognostic significance of this method. Ambulatory blood pressure values are reproducible and this method avoids the so-called placebo effect; thus, this method is useful in clinical studies investigating the efficacy and duration of action of antihypertensive drugs. Data from 1 study in which hypertensive patients were treated with slow release verapamil 240 mg, enalapril 20 mg, nitrendipine 20 mg and placebo, given once daily for 8 weeks according to a double-blind parallel group design, showed that mean 24-hour ambulatory blood pressure was reduced by all 3 drugs compared with placebo. Verapamil and enalapril showed similar antihypertensive efficacy and both drugs reduced night-time blood pressure more effectively than nitrendipine.

Blood Pressure Monitors↗

Changes in 24 hour blood pressure and in cardiac and vascular structure in normotensive subjects with parental hypertension.

Subjects with family history of hypertension represent a suitable model to investigate the mechanisms responsible for early cardiovascular structural and functional changes occurring in essential hypertension. In our study we have addressed the factors involved in determining the mild elevation in office blood pressure frequently observed in normotensive subjects with hypertensive parents. In 15 normotensive subjects with both parents hypertensive (FH++) and in 15 normotensive subjects with one parent hypertensive (FH(+)-) we found no evidence of a hyperreactivity to stress as compared to the responses of 15 normotensive subjects with no parental hypertension (FH--). On the contrary FH++ subjects were characterized by a significant although mild increase in their blood pressure values recorded either at rest and in ambulatory conditions over the 24 hours, including night sleep. FH++ and FH(+)- subjects also showed a greater left ventricular mass thickness and a greater minimal forearm vascular resistance than FH-- subjects. Thus, the elevation in blood pressure found in the pre-hypertensive stage in subjects with positive family history for hypertension does not reflect a hyperreactivity to the stress associated with physician's visit but indicates an early and persistent blood pressure elevation. This blood pressure elevation is accompanied by early cardiovascular structural changes which may indicate that these subjects are exposed to a higher risk even before developing overt hypertension.

Adult↗