Chronic copper toxicosis in growing swine.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A V Jain.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A gas-liquid chromatographic (GLC) method is described for the determination of diethylstilbestrol (DES) in molasses-based liquid feed supplements, using dienestrol diacetate as the internal standard. A sample equivalent to 110 mug DES was diluted, acidified with dilute sulfuric acid, extracted with chloroform, and subjected to basic sodium acetate cleanup. The bis-(trimethylsilyl) acetamide derivative was prepared and determined by GLC. Interfering peaks and/or low recoveries were found to be related to emulsions and the procedure incorporates centrifugation to minimize these.
A collaborative study was conducted for screening nitrate in forages with a commercially available test strip. The method involves extracting a finely ground sample with deionized water. The test strip is dipped in the sample extract. The color of the reaction zone on the test strip changes from white to pink or purple depending on the nitrate concentration in sample extract. The nitrate present in the extract is determined by comparing the color of the test strip to the color scale on the test strip container. Six blind quintuplicates of forage samples were analyzed by 20 collaborators. Nitrate concentrations in forage samples tested ranged from < 1000 ppm nitrate to > 10,000 ppm nitrate on dry matter basis. Each collaborator was asked to assign each sample to one of the 4 following nitrate concentration ranges: (1) < 1000 ppm, (2) 1000 to 5000 ppm, (3) > 5000 ppm to 10,000 ppm, and (4) > 10,000 ppm. Nineteen of 20 collaborators reported results. Results from 2 laboratories were rejected as outliers by inspection and chi 2 test. Sensitivity rates (p+) ranged from 0.965 to 0.998, with standard errors of 0.006 to 0.16. Specificity rates (p-) ranged from 0.991 to 0.997 for the 4 ranges, with standard errors of 0.003 to 0.006. False-positive rates (pf+) ranged from 0.006 to 0.046, with standard errors of 0.006 to 0.025. False-negative rates (pf-) ranged from 0.003 to 0.007, with standard errors of 0.003 to 0.006. Screening nitrate in forages with a test strip has been adopted first action by AOAC INTERNATIONAL.