Regional blood flow during pulsatile cardiopulmonary bypass and after circulatory arrest in an infant model.

BACKGROUND: Pulsatile perfusion systems have been proposed as a means of improving end-organ perfusion during and after cardiopulmonary bypass. Few attempts have been made to study this issue in an infant model. METHODS: Neonatal piglets were subjected to nonpulsatile (n = 6) or pulsatile (n = 7) cardiopulmonary bypass and 60 minutes of circulatory arrest. Cerebral, renal, and myocardial blood flow measurements were obtained at baseline, on bypass before and after circulatory arrest, and after bypass. RESULTS: Cerebral blood flow did not differ between groups at any time and was diminished equally in both groups after circulatory arrest. Renal blood flow was diminished in both groups during bypass but was significantly better in the pulsatile group than in the nonpulsatile group prior to, but not after, circulatory arrest. Myocardial blood flow was maintained at or above baseline in the pulsatile group throughout the study, but in the nonpulsatile group, it was significantly lower than baseline during CPB prior to circulatory arrest and lower compared with baseline and with the pulsatile group 60 minutes after CPB. CONCLUSIONS: Pulsatile bypass does not improve recovery of cerebral blood flow after circulatory arrest, may improve renal perfusion during bypass but does not improve its recovery after ischemia, and may have beneficial effects on myocardial blood flow during bypass and after ischemia compared with nonpulsatile bypass in this infant model.

Animals↗

Design of a physiologic pulsatile flow cardiopulmonary bypass system for neonates and infants.

Cardiopulmonary bypass surgical techniques that allow a surgeon to operate on the infant's heart use an extracorporeal circuit consisting of a pump, oxygenator, arterial and venous reservoirs, cannulae, an arterial filter, and tubing. The extracorporeal technique currently used in infants and neonates is sometimes associated with neurologic damage. We are developing a modified cardiopulmonary bypass system for neonates that has been tested in vitro and in one animal in vivo. Unlike other extracorporeal circuits which use steady flow, this system utilizes pulsatile flow, a low prime volume (500 ml) and a closed circuit. During in vitro experiments, the pseudo patient's mean arterial pressure was kept constant at 40 mmHg and the extracorporeal circuit pressure did not exceed a mean pressure of 200 mmHg. In our single in vivo experiment, the primary objective was to determine whether physiologic pulsatility with a 10 F (3.3 mm) aortic cannula could be achieved. The results suggest that this is possible.

Animals↗

Design and performance of a physiologic pulsatile flow neonate-infant cardiopulmonary bypass system.

The authors have designed an alternative infant cardiopulmonary bypass (CPB) system using the University of Texas neonatal pulsatile pump, which produces physiologic pulsatile flow and allows a low priming volume. This system has been tested with normothermic CPB (n = 8), and deep hypothermic circulatory arrest (n = 14) in 3 kg piglets. Data obtained during these studies suggest that this system can produce flow characteristics that approximate normal physiologic values. Unlike other pulsatile pumps, this pump can produce a very small stroke volume, ranging from 0.5 to 7.1 ml with a pump rate of 120 beats/min. These stroke volumes correspond to our target value of 1 ml/kg body weight. This system is designed to cause minimal hemodilution and minimal exposure of blood to foreign surface areas. The pump does not produce negative pressure, and therefore the venous reservoir is not essential, and only a cardiotomy reservoir is required. Conclusions after in vivo testing are, first, that physiologic pulsatile flow can be achieved readily with this system using a 10 Fr aortic cannula in 3 kg piglets; and second, that a significant reduction in priming volume and hemodilution can be obtained using this system.

Animals↗

Evaluation of a physiologic pulsatile pump system for neonate-infant cardiopulmonary bypass support.

An alternate physiologic pulsatile pump (PPP) system was designed and evaluated to produce sufficient pulsatility during neonate-infant open heart surgery. This hydraulically driven pump system has a unique "dual" pumping chamber mechanism. The first chamber is placed between the venous reservoir and oxygenator and the second chamber between the oxygenator and patient. Each chamber has two unidirectional tricuspid valves. Stroke volume (0.2-10 ml), upstroke rise time (10-350 msec), and pump rate (2-250 beats per minute [bpm]) can be adjusted independently to produce adequate pulsatility. This system has been tested in 3-kg piglets (n = 6), with a pump flow of 150 ml/kg/min, a pump rate of 150 bpm, and a pump ejection time of 110 msec. After initiation of cardiopulmonary bypass (CPB), all animals were subjected to 25 minutes of hypothermia to reduce the rectal temperatures to 18 degrees C, 60 minutes of deep hypothermic circulatory arrest (DHCA), then 10 minutes of cold perfusion with a full pump flow, and 40 minutes of rewarming. During CPB, mean arterial pressures were kept at less than 50 mm Hg. Mean extracorporeal circuit pressure (ECCP), the pressure drop of a 10 French aortic cannula, and the pulse pressure were 67+/-9, 21+/-6, and 16+/-2 mm Hg, respectively. All values are represented as mean+/-SD. No regurgitation or abnormal hemolysis has been detected during these experiments. The oxygenator had no damping effect on the quality of the pulsatility because of the dual chamber pumping mechanism. The ECCP was also significantly lower than any other known pulsatile system. We conclude that this system, with a 10 French aortic cannula and arterial filter, produces adequate pulsatility in 3 kg piglets.

Animals↗

Decrease in red blood cell deformability caused by hypothermia, hemodilution, and mechanical stress: factors related to cardiopulmonary bypass.

During extracorporeal circulation in cardiopulmonary bypass (CPB) surgery, blood is exposed to anomalous mechanical and environmental factors, such as high shear stress, turbulence, decreased oncotic pressure caused by dilution of plasma, and moderate and especially deep hypothermia widely applied during CPB in infants. These factors cause damage to the red blood cells (RBCs), which is manifest by immediate and delayed hemolysis and by changes in the mechanical properties of RBCs. These changes include, in particular, decrease in RBC deformability impeding the passage of RBCs through the microvessels and may contribute to the complications associated with CPB surgery. We investigated in vitro the independent and combined effects of hypothermia, plasma dilution, and mechanical stress on deformability of bovine RBCs. Our studies showed each of these factors to cause a significant decrease in the deformability of RBCs, especially acting synergistically. The impairment of RBC deformability caused by hypothermia was found to be more pronounced for RBCs suspended in phosphate buffered saline (PBS) than for RBCs suspended in plasma. The decrease in RBC deformability caused by mechanical stress was significantly exacerbated by dilution of plasma with PBS. In summary, results of our in vitro study strongly point to a possible detrimental consequence of conventional CPB arising from increased RBC rigidity, which may lead to impaired microcirculation and tissue oxygen supply.

Animals↗

Pulsatile and nonpulsatile flows can be quantified in terms of energy equivalent pressure during cardiopulmonary bypass for direct comparisons.

The purpose of this study was to quantify and compare pulsatile and nonpulsatile pressure and flow waveforms in terms of energy equivalent pressure (EEP) during cardiopulmonary bypass in a neonatal piglet model. EEP is the ratio of the area under the hemodynamic power curve and the flow curve. Piglets, mean weight of 3 kg, were used in physiologic pulsatile pump (n = 7), pulsatile roller pump (n = 6), and nonpulsatile roller pump (n = 7) groups. Data (waveforms of the femoral artery pressure, pump flow, and preaortic cannula extracorporeal circuit pressure) were collected during normothermic cardiopulmonary bypass at 35 degrees C (15 minutes on-pump), before deep hypothermic circulatory arrest (pre-DHCA) at 18 degrees C, and after cold reperfusion and rewarming (post-DHCA) at 36 degrees C. The pump flow rate was 150 ml/kg/min in all three groups. During pulsatile perfusion, the pump rate was 150 bpm in both pulsatile groups. Although there was no difference in mean pressures in all groups, EEP and the percentage increase of pressure (from mean pressure to EEP) of mean arterial pressure and preaortic cannula extracorporeal circuit pressure were higher with pulsatile perfusion compared with nonpulsatile perfusion (p < 0.001). In particular, the physiologic pulsatile pump group produced significantly higher hemodynamic energy compared with the other groups (p < 0.001). These results suggest that pulsatile and nonpulsatile flows can be quantified in terms of EEP for direct comparisons, and pulsatile flow generates higher energy, which may be beneficial for vital organ perfusion during cardiopulmonary bypass.

Animals↗

Monitoring regional cerebral oxygen saturation using near-infrared spectroscopy during pulsatile hypothermic cardiopulmonary bypass in a neonatal piglet model.

Impairment of cerebral oxygenation in neonates and infants after hypothermic nonpulsatile cardiopulmonary bypass (CPB) support is well documented. The objectives of this study were: 1) using a neonatal piglet model to continuously monitor the regional cerebral oxygen saturation (rSO2) by near-infrared spectroscopy during pulsatile hypothermic CPB; and 2) to quantify the pulsatile flow in terms of energy equivalent pressure (EEP). After initiation of CPB, all piglets (n = 5) were subjected to 15 minutes of core cooling, reducing the rectal temperature to 25 degrees C, followed by 60 minutes of hypothermic CPB, then 10 minutes of cold reperfusion, and 30 minutes of rewarming. During CPB, mean arterial pressures (MAPs) and pump flow rates were maintained at 40-45 mm Hg and 150 ml/kg/min, respectively. During normothermic CPB, the rSO2 was significantly increased, compared with the pre-CPB level (56.8 +/- 5.2% vs. 41.8 +/- 5.5%, p < 0.01). At the end of cooling, the rSO2 level was 76.8 +/- 8.6% (p < 0.001 vs. pre-CPB). After 60 minutes of hypothermic CPB and 30 minutes of rewarming, the rSO2 level was decreased to 38.6 +/- 4.2%, which was not significantly different compared with the pre-CPB level. The average increase in pressure (from MAP to EEP) was 5 +/- 1%, and the average increase in extracorporeal circuit pressure (from ECCP to EEP) was 13 +/- 2%. This extra pressure may help to provide better regional cerebral oxygen saturation. During pulsatile CPB, there was no rSO2 deficiency in this high flow model. Near-infrared spectroscopy responded well to changes in rSO2 during different stages of these experiments and might be a helpful tool for intraoperative monitoring.

Animals↗

Error associated with the choice of an aortic cannula in measuring regional cerebral blood flow with microspheres during pulsatile CPB in a neonatal piglet model.

The effectiveness of an infant pulsatile cardiopulmonary bypass (CPB) system on maintaining regional cerebral blood flow (CBF) using two different types of aortic cannulae in 3 kg piglets has been investigated. The University of Texas Neonatal Pulsatile Pump was used with either a DLP (Group I, n = 6) or an Elecath (Group II, n = 7) 10Fr aortic cannula. In all the subjects, nasopharyngeal temperature was reduced to 18 degrees C, followed by 1 hr of deep hypothermic circulatory arrest (DHCA), then 45 min of rewarming. During cooling and rewarming, alpha-stat blood gas management was used. The radionuclide labeled microsphere technique was used to determine blood flows in the cerebellum, basal ganglia, brainstem, right and left hemispheres, as well as global CBF (ml/100 g/min). When the DLP aortic cannula was used, regional and global CBF appeared to be higher pre- and post DHCA. In both groups regional CBF was significantly decreased following DHCA. Although better pulsatile flow was attained using the DLP cannula and this may have resulted in higher regional CBF, these results must be interpreted in light of the large standard deviations noted when this cannula was chosen for the studies. These results demonstrate the importance of choosing an appropriate aortic cannula for measuring regional CBF with a pulsatile neonate-infant CPB system.

Animals↗