The Nordic Trueness Project 2002: use of reference measurement procedure values in a general clinical chemistry survey.

Up to 136 laboratories participated in a joint effort to assess the trueness of routine measurements for 14 serum components. An unmodified, fresh-frozen human serum ("IMEP-17 Material 1"), produced for an international inter-laboratory comparison, served as the "master material". The serum had assigned values of the highest available metrological quality, and is assumed to involve no or negligible commutability problems. The material was used in the assignment of traceable values to two other reference sera, "CAL" and "X", through parallel measurements on the three materials according to a common protocol. In this transfer process, uncertainty estimates were provided for all values. The material CAL had been supplied with reference measurement procedure values in 1997, and the two sets of assigned values agreed well. A lyophilized control serum "HK02" was also included in the routine analysis series. It, too, had assigned values based on reference measurement procedures. Significant matrix effects were found. The project has provided: Assigned traceable values for 14 components in a fresh-frozen serum, available to Nordic laboratories for the coming years as "NFKK reference serum X"; Confirmation of earlier assigned reference measurement procedure values for a number of components in CAL, the main calibrator in the Nordic Reference Interval project (NORIP). The transferred values will now serve as the primary reference.; Evidence of long-term stability ( > or = 5 years) of the fresh-frozen serum CAL when stored at -80 degrees C; Evidence of substantial matrix effects in the processed serum HK02. The findings should be used to discuss to what extent reference measurement procedure values are useful and cost-efficient for this type of material.

Blood Chemical Analysis↗

The Nordic Reference Interval Project 2000: recommended reference intervals for 25 common biochemical properties.

Each of 102 Nordic routine clinical biochemistry laboratories collected blood samples from at least 25 healthy reference individuals evenly distributed for gender and age, and analysed 25 of the most commonly requested serum/plasma components from each reference individual. A reference material (control) consisting of a fresh frozen liquid pool of serum with values traceable to reference methods (used as the project "calibrator" for non-enzymes to correct reference values) was analysed together with other serum pool controls in the same series as the project samples. Analytical data, method data and data describing the reference individuals were submitted to a central database for evaluation and calculation of reference intervals intended for common use in the Nordic countries. In parallel to the main project, measurements of commonly requested haematology properties on EDTA samples were also carried out, mainly by laboratories in Finland and Sweden. Aliquots from reference samples were submitted to storage in a central bio-bank for future establishment of reference intervals for other properties. The 25 components were, in alphabetical order: alanine transaminase, albumin, alkaline phosphatase, amylase, amylase pancreatic, aspartate transaminase, bilirubins, calcium, carbamide, cholesterol, creatine kinase, creatininium, gamma-glutamyltransferase, glucose, HDL-cholesterol, iron, iron binding capacity, lactate dehydrogenase, magnesium, phosphate, potassium, protein, sodium, triglyceride and urate.

Biomarkers↗

Minimally processed fresh frozen human reference sera: preparation, testing, and application to international external quality assurance.

The preparation of unmodified or minimally processed fresh frozen human sera is described, as well as the previous use of such sera, e.g. in Nordic and international external quality assurance (EQA) activities. The unmodified serum is prepared from fresh donors' blood collected in dry bags and allowed to coagulate. The serum is collected "on the clot", pooled, filtered, mixed, dispensed in polypropylene vials and frozen at -80 degrees C without further processing. Some batches were slightly modified by spiking or dilution. Critical steps of the production and use of the sera are described and improvements are discussed. A total of 34 different batches have been prepared since 1985. Results from homogeneity and stability studies are presented. The studies cover 18 routine components in serum stored at +4 degrees C to 37 degrees C for up to 34 days. Good stability was observed for storage of all components, with the exception of triglyceride. Amylase, creatininium, glucose, gamma-glutamyltransferase, urate (and perhaps carbamide) showed deterioration after 13 days of incubation at 37 degrees C. The long-term stability at -80 degrees C is reviewed and new data are presented, e.g. as consensus values from EQA schemes, where the same serum has been sent out three times over 5 years, and from reference measurement procedure values that have been assigned twice with an interval of 5 years. Furthermore, a 10-year stability study has been started.

Blood Specimen Collection↗

Reference individuals, blood collection, treatment of samples and descriptive data from the questionnaire in the Nordic Reference Interval Project 2000.

The rules for recruitment of reference individuals, inclusion and preparation of individuals, blood collection, treatment of samples (and control materials) and analysis at the 102 medical laboratories attending the Nordic Reference Interval Project (NORIP) are given as well as the rules for central exclusion of reference individuals. The individuals (18-91-year-olds) should be evenly distributed on age and gender groups. The 3002 reference individuals who contributed at least one reference value to the finally suggested reference intervals were characterized using the information in the questionnaire. Gender, age and country are the main entries in the tables. Other variables in the cross-tables or figure are height, weight, body mass index, ethnic origin, heredity for diabetes, chronic disease, oestrogens or oral contraceptives, other medication, hard physical activity, previous blood donations, smoking habits, use of alcohol, hours since last meal and time of blood collection (hour, day of week, month, year). The Danes had the highest alcohol consumption and the Icelanders had the highest body mass index. The information in this article may interest potential users of the Nordic Reference Interval Project bio-bank and database (NOBIDA) in which serum, Li-heparin plasma and EDTA buffy coat from the mentioned individuals are stored below -80 degrees C.

Adolescent↗

Calibration of the Ektachem Amylase method using human reference materials and the Phadebas Blue Starch method as an interim reference method.

In a multilaboratory study a consensus was established to calibrate the Ektachem Amylase method to reproduce the results of the Phadebas Blue Starch method. The calibration graph has a slope = 3.39 and intercept = 25. For the Ektachem Amylase method the reaction-rate ratio between salivary and pancreatic amylase was calculated to be 0.89, relative to that of the Phadebas Blue Starch method. A calibration value for the Nordic Amylase Calibrator to be used on Ektachem analysers was determined to be close to 469 U l-1 for the current batch. However, since the difference from the stated value of 460 U l-1 is negligible, the authors recommend the use of the stated value for this and future batches of the Nordic Amylase Calibrator. An error of around 10% introduced by the presence of salivary amylase is comparable to the methods accepted by the Scandinavian Committee on Enzymes. Introduction of a consensus calibration reduced the interlaboratory variation by up to 40% at all levels.

Amylases↗

A programme for assigning target values for external quality assessment schemes in countries with no authorized reference laboratories. Annex. Experiences with deviating results on Ektachem 700 XR.

The use of consensus values in external quality assessment schemes (EQAS) involves several problems and should preferably be replaced with target values obtained by methods of high metrological level. However, such values are difficult to obtain. In the present study we transferred values from the NIST (former NBS) certified reference serum SRM 909 to lyophilized and frozen test sera for various inorganic components using flame absorption or flame emission spectrometry. Enzyme values were assigned by laboratories of members of the former Scandinavian Enzyme Committee. The assignment was based on 2-4 determinations each day through 3 days of experiment. A total of 10 laboratories participated in the work. The results were utilized in a Danish EQAS. One practical concern is the fairly long time (9 months) which was needed for production, collection and compiling all data. To get an impression of how much dry chemistry analysers, e.g, could influence consensus values a Kodak Ektachem 700 XR was studied using lyophilized and frozen sera. The results are reported in the annex. On NIST SRM 909 the values found for sodium(I) were 6% too high even though the findings on frozen human sera were accurate. For aspartate aminotransferase a result three times the target values was found on a human lyophilized serum, while the values on the frozen sera only were slightly too high.

Blood↗

The basis for common reference intervals for serum potassium.

In order to investigate the relevance of the currently used lower reference limit for S-Potassium in Danish hospital laboratories, analytical bias in the measurement of S-Potassium was compared with the lower reference limit in each of 52 Danish hospital laboratories. The acceptable bias range was estimated according to Gowans et al on the basis of the result of two different reference sample groups. The estimated acceptable 0.95 bias range was 0.24 mmol/L, so the observed bias range of 0.23 mmol/L was within this limit. As all preanalytical errors tend to increase the measured S-Potassium, all acceptable bias should be in the direction of decreasing the measured value. It can be concluded that analytical performance allows for more uniform (even common) reference interval(s) in all Danish and perhaps Nordic hospital laboratories, provided that preanalytical errors can be controlled.

Chemistry, Clinical↗

A Nordic reference serum suitable for use as trueness control in the clinical routine laboratory.

The described reference serum is characterized by: liquid human serum at "normal" level stored in frozen state at -80 degrees C; minimum damage of proteins; aseptic preparation; cryoprecipitate and excess fibrin removed; serum cleared by ultracentrifugation; pH at 7.2-7.6; available in sealed glass ampoules with inert gas (one ml serum in each); specified components among most frequently analyzed analytes; homogeneity assured and stability monitored; produced under strict rules for good manufacturing practices (GMP). The assigned values are traceable to reference measurement procedures and reference materials of highest achievable metrological level; according to the present proposal the maximum allowable uncertainty of the assigned value is based on biological variation (shared common reference intervals); the uncertainty should ideally not exceed 1/5 of the maximum allowable bias of results obtained on patients samples (even 1/2 would theoretically be acceptable and, for a practical guide approximately < 1% may suffice). The present document provides some guidance of how the reference serum could be established in practice. The document also indicates the use of the material and further extension of the concept. The present work is done as a NORDKEM project.

Blood Chemical Analysis↗

Appropriate sera for calibration and control of specific protein assays.

An ultracentrifugation technique is described which makes it possible to prepare protein calibrators and control sera which (i) are stable (more than 8 years documented for nine proteins), (ii) are clear (remains clear for more than 8 years at -80 degrees C), (iii) contain genuine proteins (documented electrophoretically and immunologically), and (iv) are reproducible to prepare (collection and preparation).

Blood↗

A quality manual for the clinical laboratory including the elements of a quality system. Proposed guidelines.

Development of quality manuals is a means for the promotion of quality in clinical laboratories by describing the total quality system. It also provides opportunity of checking whether the quality system is implemented in reality and demonstrates to the hospital administration and the clinicians that the laboratory is committed to quality. The intention of these guidelines is to describe the elements of the quality system for a large clinical laboratory, and to present such a system in the form of a quality manual. The proposed guidelines comply, where relevant, with ISO/IEC guide 25 'General requirements for the technical competence of testing laboratories' and EN 45001 'General criteria for the operation of testing laboratories'. The document may be used as an aid for laboratories wishing to be accredited according to EN 45001, or intending to apply for formal certification of their quality systems, according to ISO 9001 'Quality systems--Model for quality assurance in design/development, production, installation, and servicing' utilizing ISO 9004 'Quality management and quality system elements--guidelines; Part 2 Guidelines for service'. However, information about the minimum requirements for official recognition should be obtained from the particular accreditation or certification body concerned.

Chemistry, Clinical↗

[Quality assurance of results of clinical chemical analyses in Danish hospital laboratories].

During the past 35 years, voluntary professional assessment of quality of the results of analyses in Danish hospital laboratories has been undertaken under the auspices of the Danish Society of Clinical Chemistry. The analytical quality of the laboratories is described by their "imprecision" and "accuracy" as expressed by "coefficient of variation" and "bias", respectively. The participation in these programmes was 90%. During the period between 1968 and 1987, inter-laboratory variation decreased markedly where all analyses were concerned. To ensure the necessary and adequate quality, establishment of specifications of quality based on clinical/biological goals of quality has proved necessary. The commonest reasons for large imprecision and bias from the target values are less specific methods of analysis, errors in calibration and sporadic "outliers". As the result of a stable organisation for ensuring quality, Denmark is well equipped for the introduction of the great demands in documentation of quality which may be anticipated from the Common Market during the immediate future.

Chemistry Techniques, Analytical↗

Reference intervals based on hospitalized 'healthy' patients and medical students in relation to analytical bias for serum potassium.

The reliability of reference intervals for measurements of serum (S)-potassium in Danish hospital laboratories was investigated (i) by estimation of reference interval based on two different, healthy subpopulations and (ii) by comparison of reference intervals for S-potassium with analytical bias in each of 52 Danish laboratories. (i) The reference values from 227 hospitalized 'healthy' patients were obtained during the period 1979 to 1987 from the first-drawn serum specimen from the hospitalized patients, who were later discharged from the hospital without a diagnosis. The estimated 0.95 reference interval was 3.34 to 4.52 mmol l-1. The other reference sample group consisted of 314 medical students from whom blood was collected in the period from 1983 to 1987. Here the estimated reference interval was from 3.44 to 4.53 mmol l-1. The concentration values from both reference sample groups were corrected for analytical bias (+0.05 mmol l-1). (ii) The 52 Danish laboratories revealed a considerable variability in reference intervals which, regarding the lower reference limit, ranged from 3.2 to 3.7 mmol l-1 in strong contrast to the analytical bias (ranging from -0.08 to +0.15 mmol l-1) in 50 laboratories (two outliers). There was no relationship between lower reference limit and analytical bias in the individual laboratories. It is concluded that analytical performance allows for more uniform (even common) reference intervals throughout the Danish and perhaps Nordic hospital laboratories.

Adolescent↗

Practical aspects of internal quality assurance.

The final analytical quality of a result is influenced by external and internal factors. The quality of external elements is influenced by the individual laboratory through its choice of method and supply; such elements are, e.g. reference materials, calibrators, control materials, reagents, reagent kits, instruments and disposables. The internal elements can be described through rules for good laboratory practice (GLP), and include all aspects of internal quality assurance. In this paper, GLP is used to describe the proper milieau in which the optimally selected method is working. The control system for acceptance or rejection of any particular batch of analysis, as well as the long-term control, are also described separately.

Bias↗

Quality assurance in clinical laboratories. An updated supplement to a bibliography.

A supplement to a bibliography (Scand J Clin Lab Invest 1987;47 suppl. 187:1-96) dealing with quality assurance in the clinical laboratory is presented. The increasing role of national and international standardizing bodies is stressed as well as implementation of rules of "good laboratory practice". Objectively established quality goals for all services is highly needed in order to provide a rationale for the efforts dedicated to quality improvements. Quality goals for many clinical chemistry and haematology investigations are now available.

Blood Chemical Analysis↗

External quality assessment of automated blood leukocyte differential counts and other simultaneous measured quantities.

An external quality assessment scheme (EQAS) of automated differential counts of leukocytes has been carried out using selected fresh blood specimens. The measurements were carried out one day after blood drawing because of the delay in the mail. Reference laboratories established target values for differential counts. They counted visually 600-700 cells in each specimen on smears. The consensus value among 12 laboratories for manual count of total leukocytes was used as target value, but was found on average 9% smaller than the average instrumental value. H1 results compared favorable with the target value for the differentials. The less advantageous findings on Coulter S + IV are partly explained by the age of the specimen when measured. The data indicated that better calibration of the instruments could decrease the overall variation of platelets counts and haemoglobin determinations. An EQAS involving measurement on fresh specimens is in progress.

Blood Preservation↗