Multicentric evaluation of a new assay for prothrombin fragment F1+2 determination.

A multicenter study of a recently developed ELISA for the determination of prothrombin fragment F1+2 was performed in order to evaluate analytical and clinical aspects. Mean intra-assay and inter-assay reproducibility were found to be 11.0 and 12.6%, respectively. The measuring range covered by the calibration curve reaches from 0.04 to 10.0 nM/l F1+2. Testing 133 healthy subjects a reference range of 0.37 to 1.11 nM/l F1+2 (2.5-97.5 percentile) with a median of 0.66 nM/l F1+2 was calculated. Minor difficulties with blood sampling (venous occlusion for 2 min) did not affect F1+2 plasma concentrations. Significantly increased F1+2 levels were measured in patients with leukemia (p < 0.0001), severe liver disease (p < 0.005) and after myocardial infarction (p < 0.01). Elevated F1+2 concentration before the beginning of heparin therapy (1.25 nM/l) decreased to 0.77 nM/l (p < 0.0001) after 1 day of therapy. For patients in the stable phase of oral anticoagulant therapy decreasing F1+2 concentrations were measured with increasing INR. F1+2 levels were already significantly reduced in patients with INR < 2.0 (0.56 nM/l; p = 0.0005). Thus F1+2 determination may be helpful in identifying activation processes as well as in monitoring anticoagulant therapy.

Administration, Oral↗

Silica clotting time (SCT) as a screening and confirmatory test for detection of the lupus anticoagulants.

We have developed a Silica Clotting Time (SCT) test suitable to screen patients with lupus anticoagulants (LA) and compatible with photo-optical instruments. The SCT results were considered to be positive for LA whenever the clotting times were longer than the upper normal limit at low phospholipid concentration and to be confirmed when the prolonged clotting times were corrected to normal by high phospholipid concentration. We studied plasmas from healthy subjects, patients with known diagnoses of LA, patients with acquired deficiencies of blood coagulation and hemophiliacs with anti-factor VIII antibodies. The test was positive for all LA patients, and negative for all non-LA patients except 7 hemophiliacs with anti-factor VIII antibodies. Our data indicate that the SCT is a sensitive test, suitable for screening patients suspected of having LA. Its compatibility with photo-optical instruments makes it a suitable candidate to replace the kaolin clotting time. The contemporaneous performance of SCT at low and high phospholipid concentrations provides screening and confirmation in a single procedure.

Anticoagulants↗

Multicenter evaluation of three commercial methods for measuring protein S antigen.

This collaborative study was designed to assess the performance of commercial methods for protein S (PS) antigen measurement. Twenty-five different samples were distributed deep-frozen (24 plasmas) or lyophilized (one plasma) to five laboratories. They were analyzed blind in each laboratory by the method used locally and by three commercial methods which included two electroimmunoassays (EIA), Asseraplate-PS (Diagnostica Stago), Rellplate-S (American Diagnostica) and an ELISA system, Asserachrom-PS (Diagnostica Stago). 1. Reproducibility. Average between-laboratory coefficients of variation were 15.4%, 17.6% and 25.3% for Asserachrom-PS, Asseraplate-PS and Rellplate-S. 2. Specificity. Results of all methods showed that PS is underestimated when C4b binding protein is high. This influence was particularly evident for the ELISA Asserachrom-PS and disappeared when the antibody-antigen incubation period was prolonged to overnight. 3. Sensitivity. In all laboratories ELISA detected even the lowest PS concentration (4 U/dl), whereas the two EIAs were less sensitive (lower detection limit 14 U/dl). All methods and laboratories correctly diagnosed a plasma sample from a PS congenitally deficient patient. Conclusions. This study shows that better standardization of PS immunoassays is necessary to improve accuracy and reduce interlaboratory variability before a candidate plasma standard can be successfully calibrated in an international collaborative study.

Anticoagulants↗

Markers of procoagulant imbalance in patients with inherited thrombophilic syndromes.

In 107 asymptomatic and untreated patients with inherited syndromes associated with thrombophilia (antithrombin III, protein C and protein S deficiencies), we compared in parallel two plasma peptides which reflect activation of the common coagulation pathway: the prothrombin fragment 1 + 2 (F1 + 2) and fibrinopeptide A (FPA). Both F1 + 2 and FPA were measured with simple, commercially available ELISA methods. High levels of F1 + 2 or FPA were found in about one fourth of the patients as a whole. When patients were divided according to the type of inherited thrombophilic syndrome, it appeared that F1 + 2 was more frequently elevated in protein C and protein S deficiencies than in antithrombin deficiency; and that, in general, it was no more frequently elevated than FPA. Although our data confirm the existence of a procoagulant imbalance in inherited thrombophilic syndromes due to defects of natural anticoagulant proteins, they do not confirm that such imbalance can be more frequently diagnosed by measuring F1 + 2 levels, particularly in patients with antithrombin deficiency.

Adolescent↗

Recombinant tissue factor as substitute for conventional thromboplastin in the prothrombin time test.

Relipidated recombinant tissue factor (r-TF) has been assessed in comparison with conventional rabbit brain thromboplastin (Manchester Reagent) for its suitability for measurement of prothrombin time (PT). The International Sensitivity Index (ISI) of r-TF calibrated against the International Reference Preparation BCT/253 (human plain) was found to be 0.96 and 1.12 with instrumental and manual techniques. Our study of plasmas from patients with congenital deficiencies of clotting factors covering a wide range of severity demonstrates that r-TF is able to detect even minor deficiencies of factors involved in the extrinsic and common coagulation pathways. Patients with liver diseases were correctly diagnosed with a prevalence of abnormal results comparable for both reagents. Between-assay reproducibility expressed as coefficient of variation was 2.3% and 3.9% at normal and abnormal PT levels. In conclusion, our evaluation shows that relipidated r-TF possesses the necessary requisites of sensitivity, diagnostic accuracy and reproducibility which make it a suitable candidate for PT determination both for monitoring oral anticoagulant therapy and diagnosing congenital and acquired clotting factor deficiencies. Moreover, being a highly defined reagent it may constitute a step forward in the standardization of PT testing.

Anticoagulants↗

Effects of subcutaneously administered dermatan sulfate (MF 701) on the coagulation and fibrinolytic parameters of healthy volunteers.

Eight healthy volunteers were given single subcutaneous doses of dermatan sulfate (DS, 100, 200 and 400 mg), heparin (5,000 IU) and placebo in random order. Wash-out between treatments was greater than or equal to 10 days. Serial blood samples were taken before and up to 24 hours after treatment to measure coagulation and fibrinolytic parameters. Thrombin generation was significantly inhibited by DS and heparin as compared to placebo. The effect of DS was dose-dependent. Peak inhibition after 200 mg DS was comparable to that of 5,000 IU heparin, but lasted longer. A small, bordeline significant prolongation of APTT was observed after 400 mg DS and heparin. The changes in PAI and fibrinolytic activities were those of the circadian variation. No changes were seen in the other parameters tested. In conclusion, single s.c. doses of DS (200, or 400 mg) inhibit ex vivo thrombin generation equally or more than 5,000 IU heparin and for a longer time. The effect of both treatments on fibrinolysis is negligible.

Adult↗

Effect of fish oil and coconut oil diet on the LDL receptor activity of rat liver plasma membranes.

The influence of 4 weeks treatment with fish oil and coconut oil enriched diets on the chemical composition of rat liver plasma membranes and LDL and on the binding of LDL to liver membranes was investigated. Rats fed fish oil diet showed a total, LDL and HDL plasma cholesterol concentration lower than the values observed in rats fed coconut oil and to a lesser extent lower than those of rats fed standard laboratory diet. LDL of rats on fish oil diet had a relative percentage of cholesterol and phospholipid lower, while that of triacylglycerol was greater. Furthermore, fish oil feeding was associated with a greater concentration of n - 3 fatty acids and a lower arachidonic and linoleic acid content in LDL. Liver plasma membranes isolated from fish oil rats showed a higher percentage of n - 3 fatty acids, while only a trace amount of these fatty acids was found in control and coconut oil fed animals. In binding experiments performed with LDL and liver membranes from fish oil fed rats and control rats, binding affinity (Kd = 3.47 +/- 0.93 and 4.56 +/- 1.27, respectively) was significantly higher (P less than 0.05) as compared to that found using membranes and lipoprotein from coconut oil fed rats (Kd = 6.82 +/- 2.69). In cross-binding experiments performed with fish oil LDL and coconut oil liver plasma membranes or coconut oil LDL and fish oil liver plasma membranes, the LDL binding affinity was comparable and similar to that found in fish oil fed animals. No difference was found in the Bmax among all the groups of binding experiments. Our data seem to indicate that during fish oil diet the higher binding affinity of LDL to liver plasma membranes might be partly responsible of the hypocholesterolemic action of marine oil rich diet as compared to saturated diet. Furthermore, the modifications of binding affinity induced by changes of LDL and membrane source, suggest that lipoprotein and liver plasma membrane composition may be an important variable in binding studies.

Animals↗

Factor VII clotting assay: influence of different thromboplastins and factor VII-deficient plasmas. CISMEL Study Group.

Being a putative predictor of ischemic heart disease, the measurement of factor VII (FVII) coagulant activity will be presumably requested to clinical laboratories with increasing frequency. To assess the influence on FVII assays of different thromboplastins and FVII-deficient plasmas we compared performances of all possible combinations of 5 thromboplastins and 6 deficient plasmas. The reproducibility of the clotting times of the dose-response curves for human and rabbit thromboplastins were acceptable (CV lower than 7%), whereas bovine thromboplastin had a higher CV. Reproducibility was very similar for all deficient plasmas when they were used in combination with a given thromboplastin. Responsiveness of the dose-response curve did not depend on the deficient plasma but rather on the thromboplastin: one rabbit thromboplastin was the least responsive, the bovine thromboplastin the most responsive, the human and the remaining two rabbit thromboplastins had intermediate responsiveness. Assay sensitivity to cold-activated FVII varied according to the thromboplastin: the bovine thromboplastin was the most sensitive, the human thromboplastin the least sensitive, of the three rabbit thromboplastins two were relatively sensitive, one was almost insensitive. In conclusion, our results indicate that thromboplastin rather than deficient plasma is the crucial factor in the standardization of FVII assay.

Adult↗

Fibrinogen assays: a collaborative study of six different methods. C.I.S.M.E.L. Comitato Italiano per la Standardizzazione dei Metodi in Ematologia e Laboratorio.

This collaborative study, organized by the Hemostasis Subcommittee of C.I.S.M.E.L., evaluated the accuracy, precision, and comparability of the following six widely used fibrinogen assays: total clottable fibrinogen (Blombäck and Blombäck), clotting time (Von Clauss), turbidimetry (Ellis and Stransky), Chromotime System, prothrombin time (PT)-derived, and radial immunodiffusion (RID). The same frozen samples, with normal and high contents of fibrinogen, were examined in four laboratories. The methods were calibrated with an internal standard whose fibrinogen content was determined gravimetrically. Both the Von Clauss and the RID methods were reliable, accurate, and precise, if adequate calibration was used. The PT-derived method was highly reproducible, but had some problems with accuracy. We demonstrate that an adequate calibration procedure is indispensable for reliable fibrinogen measurements whatever method is used. Because neither the calibration procedures proposed by the manufacturers nor the use of lyophilized commercial plasmas is adequate for this purpose, we urge that an international standard for fibrinogen measurement be promptly established.

Calibration↗

A prothrombin time-based functional assay of protein S.

Protein S activity was measured as the degree of prolongation of a prothrombin time-based clotting assay in which diluted test sample, protein S-depleted plasma previously incubated with Protac to fully activate protein C, bovine thromboplastin and calcium ions are mixed. Assay specificity was first demonstrated by observing that the prolongation of the clotting time was dependent on protein S and was subsequently confirmed by testing plasma samples from patients with conditions known to affect protein S activity. High sensitivity, reproducibility (interassay coefficient of variation lower than 5%) and easy handling of samples and reagents make this assay suitable for screening of congenital and acquired protein S deficiency.

Anticoagulants↗

Lipid composition and fluidity of liver mitochondria, microsomes and plasma membrane of rats with chronic dietary iron overload.

The effect of chronic dietary iron overload on the lipid composition and physical state of rat liver mitochondria, microsomes and plasma membranes was investigated. After 9 weeks of iron treatment, a significant decrease of polyunsaturated and a parallel increase of saturated fatty acids was observed in mitochondrial and plasma membrane phospholipids. By contrast, no appreciable modification of the fatty acid composition of microsomal membranes was detected. The cholesterol/phospholipid molar ratio as well as the lipid/protein ratio, did not reveal any significant difference in any of the fractions studies. Finally, no change in the molecular order of the various membranes, as assessed by electron spin resonance spectrometry, was observed following iron intoxication. These data indicate that, although in vivo chronic hepatic iron overload induces a modification of fatty acid profile in cellular structures consistent with the in vivo occurrence of lipid peroxidation, these changes do not bring about appreciable modifications of other physico-chemical parameters relevant to membrane integrity and cell viability.

Animals↗

Ambulatory 24-hr pH monitoring of esophagus, fundus, and antrum. A new technique for simultaneous study of gastroesophageal and duodenogastric reflux.

A method for outpatient 24-hr simultaneous recording of pH in the distal esophagus, fundus, and antrum was developed in order to detect acid, alkaline, alkalacid gastroesophageal reflux, and duodenogastric reflux and to study these phenomena in patients complaining of gastroesophageal reflux and dyspepsia related symptoms. Two hundred ninety-four studies were performed in 42 healthy volunteers and 237 patients. Three-probe ambulatory 24-hr esophagogastric pH monitoring applicability, tolerability, and capability to determine a relationship between symptoms which occurred during the tests, gastroesophageal reflux, and duodenogastric reflux episodes were assessed. Eighty-nine percent of the three-probe esophagogastric pH studies were easily performed. The examination was tolerated well by 86.1% of the patients and poorly by 13.9%. A temporal correlation between symptoms and pH activities was recognized in 61.3% when the esophageal tracing was considered (acid gastroesophageal reflux recording) and in 95.6% when the three pH traces were simultaneously interpreted. Alkalacid gastroesophageal reflux and duodenogastric reflux total percentage times were significantly higher in patients complaining of dyspeptic symptoms than in patients only affected by typical gastroesophageal symptoms. Three-probe 24-hr ambulatory esophagogastric pH monitoring is a simple, well-tolerated test that should be routinely adopted for the study of patients complaining of unclear upper gastrointestinal tract symptomatology.

Adolescent↗

Asymptomatic homozygous protein C deficiency.

We report a family in which 2 homozygotes with similarly very low protein C levels have different clinical symptoms. One had recurrent venous thrombosis starting at the age of 28 years, the other is still asymptomatic at 38 years despite exposure to thrombotic risk factors. Our review of 13 additional cases reveals a highly variable phenotypic expression of homozygous protein C deficiency, which can be subdivided into two groups. In the first group are 8 kindreds in which homozygotes presented at birth with unmeasurable protein C levels and life-threatening thrombosis and 1 kindred in which homozygotes are characterized by very low levels of protein C but delayed onset (10 months of age) of thrombosis. In the second group are 4 kindreds characterized by very low, but measurable, protein C levels in homozygotes who survived beyond the neonatal period into adulthood with histories of moderately severe thrombosis. The present case demonstrates that protein C levels lower than 10% are compatible with a negative history for thrombosis, not only in the neonatal period but also during adulthood, and suggests that in some homozygotes other factors need to interact for full clinical penetrance of the defect.

Adult↗

Effects of bile acid pool composition on hepatic metabolism of cholesterol in man.

This work reviews the evidence concerning the role of the bile acid pool composition in the regulation of the overall hepatic metabolism of cholesterol in man. It has been known that bile acids regulate bile secretion, biliary lipid transport and hepatic cholesterol metabolism. However, the intimate mechanisms of these regulatory functions are not well understood. Current thinking attributes most of this regulation to the size of the bile acid pool. A typical example is represented by the negative feed-back mechanism by which bile acids returning to the liver control their own synthesis. Recent evidence however tend to suggest that not only the size but also the composition contributes to the regulatory activity of the bile acid pool. Specifically the hydrophobic-hydrophilic balance of the pool, as resulting from the characteristics and the proportions of the individual bile acids present within the pool, seems to dictate most of the effects of bile acids on hepatic cholesterol metabolism. Thus abundance within the pool of hydrophobic bile acids, such as deoxycholic or chenodeoxycholic acid, seems to induce a greater biliary lipid secretion and to exert inhibition of cholesterol and bile acid synthesis whereas hydrophilic bile acids such as ursodeoxycholic acid seem to be uneffective. It follows that by changing the composition of the bile acid pool it is possible to influence the hepatic metabolism of cholesterol.