Security aspects of teleradiology between the university centre and outlying hospitals in Tyrol.

We assessed a data security system using biometric fingerprint techniques and smartcards to control access to a teleradiology system. Clinical cases were initially discussed between the referring physician and radiologist in Tyrol using a video-phone. Subsequent correspondence, including the transmission of images between the referring physician and the radiologist, was carried out by e-mail using the security system to prevent unauthorized access to patient information. Seventy-eight teleradiology sessions were conducted using this data security system. Speed and stability of data exchange were unaffected by the additional security feature. The average log-on time to the system was 7.8 s. The average training time on how to use the system was 15 min. The radiologist was able to issue a final patient report using the system within 1.5 of the initial contact. The data security feature was user-friendly and did not hinder the normal teleradiology consultation.

Austria

MRI findings in cerebral fat embolism.

The purpose of this retrospective study was to demonstrate the MRI features of cerebral manifestations in patients with fat embolism syndromes in comparison with cerebral CT (CCT). Magnetic resonance imaging was performed according to standard protocols revealing multiple small non-confluent hyperintense intracerebral lesions larger than 2 mm on proton-density and T2-weighted images to various extents in three of four patients with clinically suspected cerebral fat embolism. Cerebral CT was negative in all patients. Our findings confirm that MRI can detect cerebral fat embolism with a higher sensitivity than CCT. Thus, MRI should be the first choice for imaging of cerebral fat embolism.

Adolescent

A cost analysis of an emergency computerized tomography teleradiology system.

We carried out a cost analysis of a teleradiology system for emergency computerized tomography (CT) examinations. Teleradiology was implemented by connecting two spiral CT scanners in the University Hospital in Innsbruck and the Regional Hospital in Zwettl. It enabled the remote hospital in Zwettl to get fast and competent reports of emergency CT examinations when there was no specialist radiologist available. In 13 months' use for routine night and weekend service, the system proved fast and reliable. During the study period 121 emergency examinations of 116 patients were transmitted from Zwettl to Innsbruck. The fixed costs of teleradiology were for the ISDN connection and amounted to DM230 plus DM696/year rental. The average cost of one emergency CT examination by teleradiology was DM372 (range 308-453). One possible alternative, transporting the films by taxi for reporting elsewhere, was cheaper (estimated cost DM156), but would have been much slower. Another alternative, transporting the patient to the nearest central hospital for scanning, was much more expensive: DM524 by road or DM4667 by helicopter ambulance.

Austria

[Virtual endoscopy with post-processing helical CT data sets].

PURPOSE: The purpose of this work was to test a newly developed, post-processing software for virtual CT endoscopic methods. Virtual endoscopic images were generated from helical CT data sets in the region of the shoulder joint (n = 2), the tracheobronchial system (n = 3), the nasal sinuses (n = 2), the colon (n = 2), and the common carotid artery n = 1). Software developed specifically for virtual endoscopy ("Navigator") was used which, after a previous threshold value selection, makes the reconstruction of internal body surfaces possible by an automatic segmentation process. We have evaluated the usage of the software, the reconstruction time for individual images and sequences of images as well as the quality of the reconstruction. All pathological findings of the virtual endoscopy were confirmed by surgery. RESULTS: The post-processing program is easy to use and provides virtual endoscopic images within 50 seconds. Depending of the extent of the data set, virtual tracheobronchoscopy as a cine loop sequence required about 15 minutes. Through use of the threshold value-dependent surface reconstruction the demands on the computer configuration are limited; however, this also created quality problems in image calculation as a consequence of the accompanying loss of data. CONCLUSIONS: The Navigator software enables the calculation of virtual endoscopic models with only moderate demands on the hardware.

Artifacts

Technetium-99m human immunoglobulin scintigraphy in psoriatic arthropathy: first results.

Standard bone scintigraphy [using technetium-99m methylene diphosphonate (MDP)] is widely held to be the most sensitive method for the early detection of psoriatic arthropathy. Preliminary results of this study reveal that 99mTc human immunoglobulin (HIG) scintigraphy demonstrates a typical premature pattern of extradermal psoriatic disease in digits indicative of the early stage of psoriatic arthritis. This pattern was also found in a rare case of psoriatic arthropathy without skin lesions. 99mTc-HIG scintigraphy appears to reveal the initial inflammatory characteristics of later bone lesions. In the advanced stage of psoriatic arthritis, 99mTc-MDP and 99mTc-HIG scans were found to be equally sensitive in the detection of the affected joints. Thus 99mTc-HIG scintigraphy seems to be useful in the early detection of psoriatic arthropathy and also in advanced psoriatic arthritis, as well as for the detection of psoriatic arthropathy without skin lesions.

Arthritis, Psoriatic