Search PubMed⌕ Search

Biomedical subjects

A Soyer

Publications and source records attributed to A Soyer.

18 recordsLinked to original sources

X-ray standing waves in a heterostructure: application to a Zn(1-x)CoxO epilayer on ZnO(00.1)-O substrate.

X-ray standing waves (XSW) in a thin epitaxic film are treated in the framework of the dynamical theory. It is demonstrated that the fluorescence yield around the main peak of the rocking curve has essentially the same characteristics as that of the usual XSW on a bulk crystal surface. Thus, XSW provide a direct method to probe the atom position in a thin film. The method was applied to an epilayer of the diluted magnetic semiconductor Zn0.94Co0.06O, in order to determine the Co-atom position. The XSW established that Co atoms occupy the substitutional Zn site in the ZnO matrix, although their coherent fraction, which measures the degree of order, is rather low. Moreover, the measurement of the Zn fluorescence in the film gives approximately the same value for the coherent fraction of the Zn atoms. Besides, by using the substrate rocking curve, it is shown that the XSW signal of the Zn atoms in the substrate can be detected through the film. This interesting approach allows the coherent fraction of an element of a substrate below an interface to be probed in situ. For the Zn fluorescence, the coherent fraction is lower near the interface than in the bulk. These results should relate to strains and defects on both sides of the interface.

Journal Article↗

Voronoï tessellation reveals the condensed matter character of folded proteins.

The packing geometry of amino acids in folded proteins is analyzed via a modified Voronoï tessellation method which distinguishes bulk and surface. From a statistical analysis of the Voronoï cells over 40 representative proteins, it appears that the packings are in average similar to random packings of hard spheres encountered in condensed matter physics, with a quite strong fivefold local symmetry. Moreover, the statistics permits one to establish a classification of amino acids in terms of increasing propensity to be buried in agreement with what is known from chemical considerations.

Chemical Phenomena↗

Kinetics of oxidation of the lipids and proteins of cod sarcoplasmic reticulum.

Lipid and protein oxidation in an NADH-Fe enzymic and an ascorbate-Fe nonenzymic system were determined simultaneously. The nonenzymic iron-reducing system gave rapid oxidation of lipid that leveled off at values much lower than those achieved in the enzymic system, which showed a continuous increase over the 1 or 2 h incubation times used. Protein sulfhydryl oxidation was more rapid in the nonenzymic system for total and accessible sulfhydryl groups, but the enzymic system oxidized the inaccessible sulfhydryl groups more rapidly. Both lipid and protein oxidations appeared to begin simultaneously. In the enzymic system, more lipid oxidation was achieved on a molar basis than oxidation of protein sulfhydryl groups, while in the nonenzymic system this was reversed. These data probably reflect the site specificity of the production of oxidizing elements in the two systems. The greater lipid oxidation in the enzymic system suggests that this may be the more important ferric iron-reducing system during storage of fish muscle.

Animals↗

Creutzfeldt-Jakob disease diagnosable by EEG and cerebrospinal fluid analysis without brain biopsy: a case report.

This case illustrates a classic example of CJD in its clinical presentation and course and the EEG. It also shows dramatically the utility of a newly developed protein assay in the diagnosis of this disease. This assay has the potential of eliminating the need for brain biopsy in most cases, thus providing a safer diagnostic method for both staff and patients. In addition, the case points out that anatomical structural studies such as CT and MRI do not replace the utility of EEG in the comprehensive evaluation of rapid onset dementia, but rather complement the usefulness of EEG.

Cerebrospinal Fluid Proteins↗

Scanning electron microscopic evaluation of the effects of an air-abrasive system on dental implants: a comparative in vitro study between machined and plasma-sprayed titanium surfaces.

An in vitro comparative study was conducted in order to evaluate the effects of an air-abrasive system on dental implant surfaces. Eight new titanium dental implants, four standard machined implants (machined group), and four standard plasma-sprayed implants (plasma-sprayed group) were selected for investigation. Both neck and body surfaces of the implants were analyzed. Each pair of implants in each group was treated as follows: the spray of the air-abrasive unit was applied to each area for 5 seconds on the first implant and 15 seconds on the second implant. A total of 24 areas were observed: 16 test implants and 8 controls. Scanning electron photomicrographs were analyzed by 3 examiners using a category rating scale (kappa = 0.594). The images were also computerized for texture analysis. The results indicate that a single air-powder abrasive treatment of the dental implants selected for this study modified their exposed surfaces. After treatment, the threaded neck surface of a machined group implant was least affected, whereas the body was the most altered. In the plasma-sprayed group, comparisons between implant surfaces showed little change. In the machined group, more change was observed in both neck and body areas. In all specimens, a 5-second exposure to the air-powder abrasive did not induce deep changes in the surfaces. A 15-second exposure modified all the specimen surfaces. Further studies are needed to evaluate the effect of these changes on the biological osseointegration process.

Air↗

Digital image ratio: a new radiographic method for quantifying changes in alveolar bone. Part 1: Theory and methodology.

A new world, digital image ratio (DIR), has been developed for directly measuring changes in alveolar bone. The image on the computer monitor represents the relative mass change between two radiographs. Fourier filtering is used to reduce noise artefacts. This method is validated through an experiment with a step wedge. DIR needs only a preliminary calibration of the experimental conditions of operation and avoids tedious calibrations for each measurement as in the case of digital image substraction. Low-voltage X-ray techniques are suggested for long-term quantitative studies of patients to minimize irradiation doses.

Absorptiometry, Photon↗

Digital image ratio: a new radiographic method for quantifying changes in alveolar bone. Part II: Clinical application.

As reported in a previous paper (1) we have developed a new technique, Digital Image Ratio (DIR), which theoretically avoids some of the drawbacks of quantitative digital substraction radiography. DIR allows the direct computation and visualization of bone-mass-ratio changes. This second paper describes the use of DIR analysis to examine 20 sites in 8 patients undergoing regenerative periodontal therapy. Standardized reproducible radiographs of these 20 sites were taken before and 12 months after surgery. Ten experimental sites were treated with bone graft substitutes (natural coral or natural coral+collagen), and 10 control sites by debridement alone. None of the experimental sites had a density ratio below 1, where 1 indicates no change. The error was +/- 0.07 (0.93-1.07). The experimental sites showed an 18% mean increase in bone density (1.18), which increased to 23% (1.23) for sites filled with natural coral alone. All the control sites had values close to 1.00 (1.00 +/- 0.07) except for 3 sites, which showed a 9-15% loss of bone density. It is thus possible to compare and quantify the changes in experimental and control sites in the same patient using the percentage gain or loss of bone density. This demonstrates that DIR is suitable for clinical applications, and can be used in clinical analysis when bone changes are expected.

Alveolar Process↗

Computer reconstruction of nucleolar architecture by interactive three-dimensional color display.

The first complete three dimensional ultrastructural reconstruction of pancreatic cell nucleoli, was done using EM and computer 3D-assisted reconstruction of serial sections with interactive 3D back-to-front and color display methods based on voxel representation. The purpose of the study was to depict the architecture of the nucleolar components. We obtained information about the location of the nucleolus within the nuclear volume and about the shape and polarity of the 3 main nucleolar territories.

Animals↗

Three-dimensional computer reconstructions from serial sections of cell nuclei.

The analysis of ultrathin serial sections as 3-dimensional (3D) information requires interpretation and display of a large amount of data. We suggest a simple way to solve this problem; it permits presentation of a series of sections as a 3D color image of good quality. It involves a picture system with specialized hardware and software written for this purpose. 3D images of cellular organelles have been drawn either by manually defining the contour of the objects or by thresholding of the volumes in the structures. These 2 methods allow rapid drawing of the image on the screen. It is possible to determine the position, shape and size of 3D structures. This interactive system allows the user to choose between several options: colors, removal of parts of the object, and cutout.

Animals↗

Incidence and causes of hyperbilirubinaemia in a hospital population: with particular reference to blood transfusion.

We surveyed a large hospital population of patients to establish the incidence and causes of hyperbilirubinaemia. In a review of 6890 patients, we found an overall incidence of hyperbilirubinaemia of 9%. We reviewed the case histories of 175 patients with hyperbilirubinaemia to analyse the causes and contributory factors. In 22% of patients with hyperbilirubinaemia, hepatobiliary disease was the sole cause and was a contributory cause in another 7%. Disorders of oxygen transport were the single most common cause of hyperbilirubinaemia, being the sole cause in 38% of patients and a contributing cause in a further 9%. Blood transfusion was the sole cause of elevation in bilirubin level in only three patients (1.7%), but was a very significant contributing factor in a further 18%. It is likely that Gilbert's syndrome was a contributing factor in some cases but, as there is no definitive test for diagnosis, clear identification was not possible.

Australia↗

Lateralization of brainstem lesions by brainstem auditory evoked potentials.

In eight patients with unilateral pontine and midbrain lesions, brainstem auditory evoked potentials (BAEPs) were studied with ipsilateral (Cz-Ai) and contralateral (Cz-Ac) recordings after monaural stimulation. In all cases, the most prominent abnormality was noted in BAEP generated by stimulating the ear ipsilateral to the lesions. The Cz-Ai and Cz-Ac patterns showed similar abnormalities in five of the patients and dissociated abnormalities in two patients. We conclude that: (1) Lateralization of BAEP is possible in unilateral pontine and midbrain lesions. (2) Monaural stimulation with Cz-Ai and Cz-Ac recordings is essential for lateralization. (3) The BAEP in monaural stimulation is predominantly generated from the auditory structures ipsilateral to the stimulated ear.

Brain Diseases↗