A Sotgiu

Publications and source records attributed to A Sotgiu.

31 records · Page 2Linked to original sources

Simultaneous 280 MHz EPR imaging of rat organs during nitroxide free radical clearance.

A radio frequency (RF) (280 MHz) electron paramagnetic resonance (EPR) spectroscopy and imaging apparatus has been used to localize a pyrrolidine nitroxide free radical in the rat abdomen and thorax. The nitroxide 2,2.5.5,-tetramethylpyrrolidine-1-oxyl-3- carboxylic acid (PCA) had a whole body monoexponential decay with half-life of 13.3 +/- 0.7 (n = 4), 19.4 +/- 0.2 (n = 3), and 23 +/- 2 (n = 6) min for 1, 2, and 3 mmol/kg PCA, respectively. Up to seven one-dimensional longitudinal projections were collected on six rats in the presence of a 8 mT/m field gradient. With an injection dose of 3 mmol/kg, PCA half-lives were 19 +/- 1, 17 +/- 2, and 22 +/- 2 min (n = 6) in the lower abdomen, in the liver, and in the thorax, respectively. Thorax half-life was significantly longer than liver half-life. Sequential two-dimensional images of PCA distribution in a plane longitudinal to the rat body were obtained from eight spectra in the presence of a gradient of 12 mT/m (acquisition time 5 min; spatial resolution 8 mm). After 7 min, the nitroxide was detectable in the left side of the thorax area, but it was mostly localized in the liver. PCA was more uniformly distributed in the image collected after 17 min.

Animals↗

Oxygen-dependent reduction of a nitroxide free radical by electron paramagnetic resonance monitoring of circulating rat blood.

The effects of fraction of inspired oxygen (FiO2) on the reduction of a nitroxide free radical were studied by X-band electron paramagnetic resonance (EPR) monitoring of circulating rat blood. The decay half-life of the metabolism/elimination phase increased significantly by 24 +/- 8% during hyperoxia and decreased significantly by 16 +/- 4% during hypoxia.

Animals↗

Electron paramagnetic resonance imaging of a model of a beating heart.

This paper presents an apparatus that permits synchronization of the signal acquisition from a moving sample in electron spin resonance imaging experiments. The apparatus has been designed to observe a perfused beating heart and includes all the necessary apparatus to stimulate the heart and to synchronize the signal acquisition on this stimulus. The apparatus is completed by a low-frequency electron paramagnetic resonance bridge operated at 1.5 GHz, a re-entrant cavity for the sample and air coils to obtain the field gradients. Tests were carried out on a phantom consisting of a thin-walled silicon rubber tube of the approximate dimensions of a rat heart. The phantom movements are obtained by inflating and deflating the tube with a peristaltic pump that can be reversed by computer. The acquisitions are taken in synchronization with the pump positions. The hardware used to drive the pump and to synchronize the acquisitions is also described.

Animals↗

Whole rat electron paramagnetic resonance imaging of a nitroxide free radical by a radio frequency (280 MHz) spectrometer.

Low frequency (280 MHz) electron paramagnetic resonance spectroscopy has been used to follow uptake, distribution and reduction of the nitroxyl spin label PCA in the rat. No difference of half life was found in seven rats submitted to three administrations of PCA (11.3 +/- 0.4; 11.0 +/- 0.6 and 11.5 +/- 0.7 min). Transversal two-dimensional images of PCA distribution in the rat body were obtained over 6 min by means of field gradients. PCA was observed in three regions by projections along the longitudinal axis of the rat. PCA accumulation was found in the lower abdomen 12 min after the start of the PCA injection.

Animals↗

Electron paramagnetic resonance spectroscopy on isolated rat heart: a technical note.

Spin labels have been measured directly in the isolated rat heart, perfused by the Langendorff method, using a 1500 MHz low frequency electron paramagnetic resonance spectrometer. This apparatus was previously employed to measure spin label pharmacokinetics of nitroxide sensitive to oxygen in whole mice. The heart was introduced in a resonant cavity to measure the uptake and clearance of free radicals. Various kinetic parameters were measured and are discussed, taking into account the features of the Langendorff apparatus.

Animals↗

Whole mouse nitroxide free radical pharmacokinetics by low frequency electron paramagnetic resonance.

The in vivo uptake distribution and reduction of the oxygen-sensitive nitroxide spin label PCA in the mouse monitored by low frequency electron paramagnetic resonance (EPR) spectroscopy are reported. Spectra were obtained from the head and liver regions of pentobarbital anesthetized mice during different circulatory and ventilatory conditions. Identical clearances were found in these regions during normoxia. Moderate hypoxia (10% O2-90% N2) did not significantly affect the spin label reduction rate.

Animals↗

Three-dimensional in vivo ESR imaging in rats.

The first experiment of tridimensional in vivo ESR imaging at 1.2 GHz is described in this paper. The tails of rats weighing 300-350 grams were visualized using 1 cc of a 50 * 10(-3) M solution of nitroxide free radical injected in the caudal vein. In an even distribution of spin label is assumed this would correspond to a final concentration of about 10(-4) M. A reconstruction from projections was used to obtain the images. The apparatus utilizes stationary field gradients. Projections were obtained by sweeping the main field. For 3D reconstructions, the projections were collected along 32 * 8 field gradient orientations. The whole procedure takes approximately 18 minutes.

Animals↗

High-order coils as transmitters for NMR imaging.

High-order radiofrequency transmitter coils are described that permit, in the context of NMR imaging, a knowledgeable trade-off between coil complexity and the degree of inhomogeneity over a specified volume of space. A mathematical formulation of high-order coils is developed for an axially symmetric polarizing dc field and transverse rf field. The field is created by a number of longitudinal current filaments with equal angular separations on the wall of a cylinder. In its most general form, each current can be independently specified. Circularly or linearly polarized fields can be created. Quadrature and saddleshaped coils emerge as special cases of the general formulation. The development has been tested experimentally and good agreement found. High-order coils can also be used as receivers, permitting more equal weighting of the sensitivities of each pixel.

Magnetic Resonance Spectroscopy↗

Young Investigator Award presentation at the 13th Annual Meeting of the ESMRMB, September 1996, Prague. A proton-electron double-resonance imaging apparatus with simultaneous multiple electron paramagnetic resonance irradiation at 10 mT.

The detection of free radicals in vivo is very important for the study of many physiologic and pathologic conditions. Free radicals have been implicated in a number of diseases such as ischemia, inflammation, kidney damage, and cancer. Proton-electron double-resonance imaging (PEDRI) allows the indirect detection of free radicals via the Overhauser effect. Nitroxide free radicals used for in vivo PEDRI studies present spectra with two or three lines, but most PEDRI experiments performed to date have used only single-line electron paramagnetic resonance (EPR) irradiation. There is theoretical evidence that simultaneous irradiation of multiple EPR transitions could increase the maximum achievable PEDRI enhancement. From the experimental point of view, this requires the combined use of a suitable multiple-frequency EPR source and a multiple-tuned EPR resonator. A novel radiofrequency (RF) triple-tuned loop-gap resonator for use in PEDRI has recently been developed, and dynamic nuclear polarization (DNP) data were reported. In the present study we describe a new PEDRI apparatus, equipped with a triple-tuned resonator, that is suitable for simultaneous double- or triple-EPR irradiation of nitroxide free radicals. In particular, the details of the EPR hardware used to generate the two or three EPR frequencies are given, and PEDRI images obtained with simultaneous multiple EPR irradiation are shown. Moreover, DNP experimental results showing the increase of the enhancement as a function of the EPR power for single and simultaneous double EPR irradiation are presented. The main goal of this apparatus is to improve the sensitivity and/or to reduce EPR irradiation power in a PEDRI experiment. This is likely to be particularly important in future biologic applications of PEDRI where the applied power must be optimized to reduce sample heating.

Awards and Prizes↗

Highly homogeneous circularly polarized RF field for whole body NMR imaging.

Conditions for generation of polarized RF fields in cylindrical symmetry by high order coils are presented. Whole body NMR transmitters utilizing this principle would require a current control on a certain number of loops. In the present design this is obtained by feeding each loop by an appropriate linear combination of two in quadrature waves. The development has been experimentally tested by three scaled down experimental prototypes operated at 500 kHz and a good agreement has been found.

Humans↗