MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections.

The authors present a method for obtaining magnetic resonance (MR) images of intra- and extracranial vessels from thin contiguous transaxial sections. A section-selective gradient refocusing pulse sequence with a short repetition time caused flow-related enhancement from spins that flowed perpendicular to the transaxial sections. The signal was further enhanced by means of flow compensation gradients to rephase any phase shifts resulting from moving spins in the presence of the imaging gradients. Coronal and sagittal sections, reformatted from multiple transaxial sections, are shown to have excellent vessel contrast without the use of contrast material. These images were obtained in 12 minutes of acquisition time from as many as 60 sections of 3-mm thickness. Such a technique shows significant promise for MR angiography.

Cerebral Arteries↗

Two-second MR images: comparison with spin-echo images in 29 patients.

MR images can be obtained with a 2-sec scan time when an extremely short repetition rate (22 msec), limited flip angle (30 degrees), and gradient refocused echoes are used. Comparison of 415 such images obtained in 29 patients with routine T1-weighted (TR 500, TE 25) and T2-weighted (TR 2000, TE 80) images showed that images free of respiratory artifacts could be obtained in all patients. Although abdominal organs were well seen with 2-sec scan time, overall evaluation of these organs was better on routine T1-weighted images. Vascular structures, however, were seen as well or better on the 2-sec images in 60% of cases. The images were extremely sensitive to field nonhomogeneity, and metallic artifact was exaggerated in five patients with surgical clips. Two-sec MR images provide a rapid method of localizing abdominal organs for further evaluation. The sensitivity to blood flow may assist in the assessment of vascular patency.

Adrenal Glands↗

Cine MR determination of left ventricular ejection fraction.

Cine MR imaging provides tomographic images of the heart with both high spatial and high temporal resolution. As many as 32 images per cardiac cycle can be acquired with up to four separate anatomic slices and a total imaging time of 128 cardiac cycles. End-diastolic and end-systolic volumes were determined in 11 patients, and ejection fractions were calculated. The results correlated linearly with those from cardiac catheterization (correlation coefficient of .88). We conclude that cine MR imaging can be used to obtain quantitative information about the heart and has the potential to become a valuable noninvasive means of cardiac evaluation.

Cardiac Catheterization↗

A time-of-flight method of measuring flow velocity by magnetic resonance imaging.

A new time-of-flight method for direct imaging of flow velocities by magnetic resonance is presented. The technique uses selective exciting and refocusing RF pulses to selectively affect planes oriented in orthogonal directions in space, with the region of excitation perpendicular to the flow and the refocusing region parallel to and including the flow. The positions of the sources of the resulting spin echoes are imaged, showing a displacement equal to the product of the velocity and the echo time. These images clearly show the profile of the velocity distribution, both in laminar and nonlaminar flows.

Blood Flow Velocity↗

Effect of intersection spacing on MR image contrast and study time.

The effects of section separation on image contrast and calculated T1 relaxation times were investigated in healthy volunteers and a phantom using an early commercial version magnetic resonance imaging system. The effects are explained qualitatively on the basis of side lobes of excitation occurring outside the selected section resulting in reduction of the time permitted for T1 relaxation. The options for dealing with imperfect section selection, including separation of the sections (i.e., leaving gaps) and nonsequential excitation, are illustrated and the trade-offs involved in each explained.

Brain↗

Time-of-flight MR flow imaging: selective saturation recovery with gradient refocusing.

A novel magnetic resonance flow-imaging technique is presented and its suitability evaluated for both qualitative and quantitative imaging of flow. The method is derived from a selective saturation-recovery scheme consisting of a tagging and detection pulse followed by a bipolar read gradient. The detrimental phase effects causing signal loss at fast flow are shown to be greatly reduced because of the absence of a 180 degrees pulse and its associated section-selection gradient. The second loss mechanism intrinsic to 180 degrees spin echoes, the washout of excited spins between excitation and detection pulse, likewise is not present with the discussed technique. Assuming a parabolic flow profile, the authors calculated the signal evolution curve and found it to be in agreement with the experimental washout curve. The technique is shown to provide high-intensity signals for arteries such as carotid and vertebral arteries. Arteries and veins can be differentiated by judiciously choosing interpulse intervals or by alternating selective and nonselective tagging pulses.

Blood Flow Velocity↗

Encoding strategies for three-direction phase-contrast MR imaging of flow.

Three encoding strategies for the measurement of flow velocities in arbitrary directions with phase-contrast magnetic resonance imaging are presented; their noise and dynamic range performance are compared by means of theoretical analysis and computer simulation. A six-point measurement strategy is shown to be quite inefficient in terms of velocity variance per unit time. A simple four-point method exhibits equal dynamic range; its noise depends on flow direction but on average is equal to that of the six-point method. An alternate, balanced four-point method has noise that is direction independent and has, depending on implementation, possibly lower noise levels. Either four-point method is more efficient and is preferred over the six-point approach.

Blood Flow Velocity↗

Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging.

A method for minimizing field-echo delay in moment-nulled gradient-echo imaging is presented. Even though ramps are accounted for, the analysis yields simple closed-form solutions. The method is then generalized to the section-select waveform for three-dimensional volume imaging and to flow encoding for phase-contrast imaging. Three strategies for first-moment selection in phase-contrast imaging are discussed, including a new strategy that always yields the minimum echo delay. Trapezoidal and triangular gradient lobe shapes are analyzed.

Algorithms↗

Fast spin-echo MR imaging of the abdomen: contrast optimization and artifact reduction.

The effects of various fast spin-echo (FSE) magnetic resonance (MR) imaging parameters and artifact reduction techniques on FSE image contrast and quality were studied. The authors performed 139 abdominal MR examinations, comparing standard FSE images (echo train length [ETL] = 8, echo space [E-space] = 17 msec, bandwidth = +/- 16-kHz) with FSE images with an ETL of 16 (n = 22) or FSE images with a +/- 32-kHz bandwidth and an E-space of 11-14 msec (n = 22). FSE artifact reduction techniques were evaluated with spectral fat saturation (n = 40) or with a new flow compensation FSE sequence (n = 55). Images of liver lesions were reviewed qualitatively and with contrast-to-noise ratio (C/N) measurements. Decreasing the time of echo train sampling produced superior image quality, with increased anatomic sharpness, less image artifact, and improved liver-lesion C/N. Images obtained with an ETL of 16 showed more image blurring and a 23% decrease in relative contrast and 28% decrease in relative C/N for liver tumors. Increasing the bandwidth reduced E-space, producing a 12% decrease in background noise. Artifact reduction with fat saturation or flow compensation produced images with less ghosting artifact and superior overall image quality, with 39% and 20% increases in liver-tumor C/N, respectively. FSE image quality and contrast in the depiction of hepatic disease can be optimized with careful selection of imaging parameters and the use of artifact reduction techniques.

Abdomen↗

Improved reproducibility in measuring LV volumes and mass using multicoil breath-hold cine MR imaging.

There is a generally recognized need for improvement in quality of fast cardiac MR images. Consequently, breath-hold cine MR images were obtained with multiple surface coils connected to phased array receivers, and C/N, intra-observer and inter-observer variabilities for LV volumes and mass were evaluated. Two sets of short-axis images of the LV, one with multiple surface coils and another with a body coil, were acquired in eight subjects with a fast cine MR sequence using k-space segmentation (TR/TE = 7/2.2 msec, temporal resolution = 56 msec). C/N with multicoil imaging was 32.2 +/- 7.6 (mean +/- SD), significantly higher than that with a body coil (11.0 +/- 3.3, P < .01). The mean percentage differences in intra-observer and inter-observer measurements with multicoil imaging were significantly better than those with a body coil. In conclusion, multicoil imaging provides significant gain in C/N on breath-hold cine MRI of the heart. In addition, intra-observer and inter-observer reproducibilities are improved with multicoil imaging.

Adult↗

Breath-hold MR measurements of blood flow velocity in internal mammary arteries and coronary artery bypass grafts.

Breath-hold velocity-encoded cine MR (VENC-MR) imaging is a feasible method for measuring phasic blood flow velocity in small vessels that move during respiration. The purposes of the current study are to compare breathhold VENC-MR measurements of flow velocities in the internal mammary arteries (IMA) with nonbreath-hold measurements and to characterize the systolic and diastolic flow velocity curves in a cardiac cycle in native IMA and IMA grafts. Flow velocity in 30 native IMA and 8 IMA grafts were evaluated with a breath-hold VENC-MR sequence with K-space segmentation and view-sharing reconstruction (TR/TE = 16/9 msec, VENC = 100 cm/s). In 10 native IMA, nonbreath-hold VENC-MR images were acquired as well for comparison. Breath-hold VENC-MR imaging showed significantly higher systolic and diastolic peak velocities in native IMA (43.1 cm/second +/- 15.0 and 10.0 cm/second +/- 4.8), in comparison to those of nonbreath-hold VENC-MR imaging (27.6 cm/second +/- 10.2 and 7.3 cm/second +/- 3.9, P < .05). The diastolic/systolic peak velocity ratio in the IMA grafts (.88 +/- .41) was significantly higher than that in native IMA (.24 +/- .08, P < .01). Interobserver variability in the flow velocity measurement was less than 4%. Breath-hold VENC-MR imaging demonstrated higher peak flow velocity in the IMA than nonbreath-hold VENC-MR imaging. This technique is a rapid and effective method for the noninvasive assessment of blood flow velocity in IMA grafts.

Adult↗

Dynamic contrast-enhanced breath-hold MR imaging of thoracic malignancy using cardiac compensation.

The purpose of this paper was to evaluate the use of dynamic gadopentetate dimeglumine-enhanced, breath-hold spoiled gradient-recalled (SPGR) MR imaging with cardiac compensation (CMON) compared to spin-echo MR imaging in patients with thoracic malignancy. We retrospectively reviewed MR images from 29 patients with thoracic tumors. MR imaging included axial electrocardiogram (ECG)-gated T1-weighted, fast spin echo (FSE) T2-weighted, and contrast-enhanced breath-hold fast multiplanar SPGR imaging with CMON, which selects the phase-encoding gradient based on the phase within the cardiac cycle. Images were reviewed for lung masses, mediastinal or hilar tumor, disease of the pleura, chest wall, and bones and vascular compression or occlusion. Contrast-enhanced fast multiplanar SPGR imaging with CMON produces images of the chest that are free of respiratory artifact and have diminished vascular pulsation artifact. ECG-gated T1-weighted images were preferred for depicting mediastinal and hilar tumor. The gadopentetate dimeglumine-enhanced fast multiplanar SPGR images were useful for depicting chest wall tumor, vascular compression or thrombosis, osseous metastases, and in distinguishing a central tumor mass from peripheral lung consolidation. Pleural tumor was depicted best on the FSE T2-weighted images and the contrast-enhanced SPGR images. As an adjunct to spin echo T1-weighted and T2-weighted imaging, contrast-enhanced fast multiplanar SPGR imaging with CMON is useful in the evaluation of thoracic malignancy.

Aged↗

Evaluation of the iliac arteries: comparison of two-dimensional time of flight magnetic resonance angiography with cardiac compensated fast gradient recalled echo and contrast-enhanced three-dimensional time of flight magnetic resonance angiography.

We compared dynamic contrast-enhanced three-dimensional time of flight (3DTOF) magnetic resonance angiography (MRA) with two-dimensional time of flight (2DTOF) MRA with cardiac compensated fast gradient recalled echo (C-MON) and conventional angiography (CA) when it was available. C-MON re-orders the normal data acquisition to minimize ghosting artifacts generated by pulsatile flow. The initial phase of the study involved optimization of parameters and comparison C-MON with no C = MON in eight patients and volunteers. The final phase of the study involved 53 patients who were imaged with contrast-enhanced 3DTOF MRA and 2DTOF MRA with C-MON. Thirty of these patients also had CA. In the initial phase, 2DTOF MRA with C-MON was found to be equal (n = 3) or superior (n = 5) to 2DTOF without C-MON. In the final phase, the agreement among all imaging modalities varied from substantial to almost perfect (Cohen's kappa = .6-.83). The lowest agreement was using 2DTOF to evaluate the external iliac segments. The among suggested treatments varied from substantial to almost perfect for all imaging modalities (Cohen's kappa = .73-93). The diagnostic efficacies of 2DTOF with C-MON and contrast-enhanced 3DTOF were high overall, with the lowest value being a specificity of 63% for one reader in the evaluation of an external iliac segment using 2DTOF. In summary, 2DTOF with C-MON helped to eliminate artifacts due to pulsatility in the iliac arterial segments. In our experience, both dynamic contrast-enhanced 3DTOF MRA and 2DTOF MRA with C-MON performed well in the evaluation of the iliac arteries. Both studies have high interobeserver agreement and high diagnostic efficacy. Contrast-enhanced 3DTOF MRA should be reserved for situations in which the iliac vessels are extremely tortuous or occluded or the external iliac segments are poorly seen.

Adult↗

MR imaging of venous and arterial flow by a selective saturation-recovery spin echo (SSRSE) method.

Flow velocity imaging studies have been conducted by means of a selective saturation-recovery spin echo technique, and the dependence of signal amplitude on interpulse interval, echo delay, slice-selection gradient, and flow velocity was evaluated experimentally. The simple theory predicting a steady increase of signal intensity with increasing interpulse interval until this latter equals the transit time could be verified in phantoms and was shown to permit measurement of blood flow velocity in venous structures such as the femoral vein. The flow phantom experiments further showed that the final intensity, attained when inversion time (TI) = transit time, decreases with increasing flow velocity, an effect that cannot be explained by influx of spins between the 90 degree detection pulse and the 180 degree refocusing pulse. This signal reduction is due to slice-selection gradient-induced phase shifts across the pixel, caused by the intralumenal velocity gradient, leading to destructive interference of the spin isochromats. The velocity distribution can be mapped by plotting signal intensity as a function of interpulse interval for pixels in different radial positions. To highlight arterial flow, gating is required with the acquisition delay selected such that the interpulse period TI falls in a time zone of slow flow within the cardiac cycle. By subtracting images recorded with different acquisition delays, flow images showing arterial enhancement only can be obtained, as illustrated for the femoral artery in the thigh.

Blood Flow Velocity↗

Evaluation of thoracic aortic dissection using breath-holding cine MRI.

OBJECTIVE: Our goal was to determine if breath-hold cine MRI in transaxial planes can be used for the evaluation of thoracic aortic dissection instead of conventional cine MRI since rapid imaging is required in this clinical setting. MATERIALS AND METHODS: Twelve patients with thoracic aortic dissection were imaged using a 1.5 T imager. Breath-hold images were acquired with fast cine MR sequence (TR/TE = 9/2.8, 20 degrees flip angle) using segmented k-space data acquisition. Conventional non-breath-hold cine MR images (TR/TE = 22/7.5, 35 degrees flip angle, 2 averages) were taken with flow and respiratory compensation. RESULTS: Sharpness of edges of the vessels on fast cine MR images was better than that on conventional cine MR images in 34 (57%) of 60 images. Inhomogeneous blood signal in aortic lumen due to motion artifacts was found in 2 (3%) of fast cine MR images and in 15 (25%) of conventional cine MR images. The contrast-to-noise ratios of fast cine MR images were significantly better than those of conventional cine MR images (26.4 +/- 9.1 vs. 18.5 +/- 10.1; p < 0.05) when the region of interest for noise was placed to include ghosting artifacts. CONCLUSION: Breath-hold cine MRI is a rapid technique that gives high quality images of thoracic aortic dissection and can provide a diagnosis in < 10 min of imaging time.

Aged↗

Dural sinus occlusion: evaluation with phase-sensitive gradient-echo MR imaging.

The purpose of this study was to evaluate the usefulness of limited-flip-angle, phase-sensitive velocity imaging with gradient-recalled-echo (VIGRE) MR when combined with spin-echo MR in the diagnosis of dural sinus thrombosis. The VIGRE sequence consists of a rapid single-slice acquisition, 50/15/2 (TR/TE/excitations), and 30 degrees flip angle. At each slice position, a total of four images were reconstructed; these consisted of one magnitude image and three images sensitive to proton motion in each orthogonal direction. The flow direction and flow velocity (cm/sec) were obtained from each of the phase images, and results were correlated with data obtained from a phantom experiment. In normal controls, dural sinus velocities ranged from a mean of 9.9 to 14.4 cm/sec for the transverse and superior sagittal sinuses, respectively. Three patients with proved dural sinus occlusion were studied with spin-echo images at 1.5 T. Three-dimensional time-of-flight MR angiography was also performed in one patient. The presence of dural sinus occlusion was determined by the lack of flow void on the spin-echo images, the absence of phase shift on the VIGRE study, and the presence of retrograde flow on the phase image in the sinus proximal to the occluded segment. Time-of-flight angiography overestimated the extent of the thrombosis caused by spin saturation. Follow-up VIGRE studies detected the formation of collateral flow in one patient and recanalization with the establishment of normal antegrade sinus flow in the other. We conclude that phase-sensitive MR imaging is helpful in establishing the diagnosis and extent of dural sinus occlusion.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

MR imaging of the optic nerve and sheath: correcting the chemical shift misregistration effect.

The interface between soft-tissue structures and adipose tissue may be obscured by the chemical shift misregistration effect on MR images. In the orbit, this effect occurs at the edges at the optic nerve, even on high-resolution local coil images. In both phantom and clinical studies with a 1.5 T local coil imaging system, it was found that the chemical shift misregistration effect can be minimized by positioning the patient so that the optic nerve is parallel to the frequency encoding gradient. Alternatively, the effect can be corrected by using a computer program to combine "lipid" and "water" proton images. The sensitivity of MR for optic nerve lesions should be improved by these technical modifications.

Child↗