Teicoplanin resistance in Staphylococcus haemolyticus, developing during treatment.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A Shelton.
Explore the source record for details and available documents.
The convex bileaflet valve replaces the flat biflap inflow valve designed by Long Sheng Yu and the tricusp semilunair outflow valve. One reason is easier manufacturing. Convex bileaflet valves are developed for the 11, 20, 40, 70 and 140cc ventricles. Testing included curves (Cardiac Output versus Venous Pressure, Cardiac Output versus Heart rate), flow visualization studies, paint and bloodbag studies. The curves and flow visualization were done by connecting ventricles to one of our standard mock circulations. Paint and bloodbag studies were done by connecting the hearts to a bloodbag, but the bag was filled with water for the paint studies. The curves show high cardiac output, even with pumping at high heart rates (150 BPM+). The flow visualization shows a good stream through the sinus Valsalvae. No stagnating flow is visible. The bloodbag studies which provoke thrombosis show it on the edges of the heart valves, and little in the groove between the valve and the sinus Valsalvae. Heparninzation prevents the thrombosis. Results of our tests were good. The convex bileaflet valve seems to have good future.
The action of ciprofloxacin and norfloxacin on two strains of Escherichia coli was studied by diverse methods including electronmicroscopy, viable counting and continuous turbidimetric monitoring. During the first few hours of exposure to inhibitory concentrations of the drugs, the opacity of bacterial cultures continued to increase for a period that was inversely proportional to the drug concentration. This change corresponded to the appearance of filamentous bacteria, swollen forms and some lysis. There was subsequently a gradual drop in opacity during which extensive lysis occurred. As judged by viable counts of bacteria washed free of drug, cell death occurred within 30 min of first exposure to the drugs and continued over a 3-h period. Ultrastructure studies demonstrated that lysis was preceded by the formation of vacuoles, predominantly at the poles of the cells. At these sites, breaks in the cell walls eventually occurred, resulting in extrusion of the cytoplasmic contents.
Urine samples were collected from 200 subjects undergoing intravenous pyelography. The urine histamine levels were compared with those of 132 normal control subjects, 11 subjects with systemic mastocytosis, six subjects with idiopathic anaphylaxis, and ten subjects experiencing mild anaphylactic reactions during allergy immunotherapy. Compared with normal controls, as a group, all subjects receiving intravenous contrast media had increased urine histamine (P less than 0.05 by Student's t-test) while those subjects experiencing adverse reactions had considerably larger increases. The urine histamine levels in the subjects experiencing systemic reactions were in the same range as those observed in patients having mild anaphylactic reactions to immunotherapy and somewhat lower than those found in idiopathic anaphylaxis or systemic mastocytosis. These data suggest that some histamine release accompanies infusions of contrast media in all subjects and that larger amounts of histamine release are associated with adverse reactions.
OBJECTIVE: To elucidate the factors leading to catheter loss from recurrent infection in patients on continuous ambulatory peritoneal dialysis (CAPD). DESIGN: All catheters removed from patients were prospectively examined for infection. SETTING: CAPD unit in large tertiary-care general hospital. PATIENTS: Sixty-five consecutive patients undergoing catheter removal for whatever cause; 20 catheters rejected because of desiccation or contamination in transit. INTERVENTIONS: None. MAIN OUTCOME MEASURES: Micro-organisms linked to catheter removal; their locations on removed catheters. RESULTS: Of 45 catheters removed between January 1994 and August 1995, 26 were infected: 13/26 infections were caused by Staphylococcus aureus and 7/26 by Pseudomonas aeruginosa. In only one case was S. epidermidis associated with catheter removal. The most striking finding was that the inner cuff harbored large numbers of the infecting organisms, even when antibiotics had eradicated them from the peritoneal cavity and exit site, where present, and the catheter lumen. CONCLUSION: The importance of S. aureus and Ps. aeruginosa rather than S. epidermidis in catheter loss due to relapsing infection is confirmed. Persistence of the causative organisms in the inner cuff is a likely explanation for relapse after treatment, and might be due to the predominantly intraperitoneal administration of antibiotics. A clinical trial of the effect on catheter retention of empirical use of systemic or oral agents that give high tissue levels and are active against intracellular micro-organisms, along with recommended intraperitoneal regimens, is indicated.
Konstantinov et al, in October, 1991, published a novel way to bridge a patient for heart transplantation. They proposed to cut off both ventricles high under the atrioventricular groove, leaving the atria, aorta, and pulmonary artery and their valves intact and to attach pneumatically driven, valveless pulsating pouches to assist the heart until a donor could be found. The removal of the ventricles just below the atrioventricular groove is called the "high cut"; it, however, destroys the chordae tendineae rendering the mitral and tricuspid valves insufficient. These have to be replaced by tissue inflow valves. We chose to cut off the ventricles at a lower level (the "low cut") to leave the papillary muscles on both sides intact, thereby saving the integrity of the mitral and tricuspid valves. Pulsating pouches were made to fit the heart at this lower level. They can be easily connected to the remaining heart after a specially disigned cuff has been sutured over the ventricular stumps. The pouches were pumped during the systole of the natural heart, but the myocardium may have to be electrically stimulated during systole to prevent undue distension. If the turgor is too weak to prevent distension, a sleeve over the ventricles is provided. To find the best location for these pouches, human cadaver implantations were done and the pre peritoneal cavity was found to be the most suitable. In vitro testing to determine how much flow could be pumped was done by attaching the pouches to fresh pig hearts and connecting them to a double sided mock circulation.(ABSTRACT TRUNCATED AT 250 WORDS)