Search PubMed⌕ Search

Biomedical subjects

A Schaefer

Publications and source records attributed to A Schaefer.

At least 37 records · Page 2Linked to original sources

Activation of Raf/ERK1/2 MAP kinase pathway is involved in GM-CSF-induced proliferation and survival but not in erythropoietin-induced differentiation of TF-1 cells.

The involvement of MAPK pathways in differentiation, proliferation and survival was investigated by comparing Epo and GM-CSF signalling in human factor-dependent myeloerythroid TF-1 cells with abnormal Epo-R. GM-CSF withdrawal induced cell-cycle arrest and apoptosis accompanied by increased caspase-3 activity, DNA degradation and reduced expression of the antiapoptotic Bcl-2 and Bcl-xl proteins. Readministration of GM-CSF but not Epo reversed these processes and induced proliferation. The GM-CSF promoted cell survival and proliferation correlated with MEK-1 dependent ERK1/2, Elk-1 and CREB phosphorylation and Egr-1, c-Fos expression as well as with increased STAT-5, AP-1, c-Myb and NF-kappaB DNA-binding. In contrast, Epo failed to activate the Raf-1/ERK1/2 MAPK pathway or to induce Egr-1 and/or c-Fos expression, while it induced erythroid differentiation in GM-CSF-deprived cells. In addition, the Epo-induced haemoglobin production was inhibited in the presence of GM-CSF. These results demonstrate that the activation of MAPK cascade is not necessary for Epo-induced haemoglobin production in TF-1 cells and suggest a negative cross-talk between the signalling of GM-CSF-stimulated cell proliferation and Epo-induced erythroid differentiation.

Cell Differentiation↗

Preparation and investigation of tumor affinity, uptake kinetic and transport mechanism of iodine-123-labelled amino acid derivatives in human pancreatic carcinoma and glioblastoma cells.

In developing radioiodinated agents for pancreatic and brain tumor imaging by single photon emission tomography (SPET), we prepared p-amino-3-[123I]iodo-l-phenylalanine (IAPA), p-[123I]iodo-l-phenylalanine (IPA), L-8-[123I]iodo-1,2,3,4-tetrahydro-7-hydroxyisoquinoline-3-carboxylic acid (ITIC) and L-3-[123I]iodo-alpha-methyl-tyrosine (IMT) in radiochemical yields up to 95%, and we investigated their uptake in human pancreatic carcinoma and glioblastoma cells as well as the mechanisms promoting the tumor uptake. The radiopharmaceutical uptake into tumor cells was rapid (t(1/2) < or = 5 min) and temperature- and pH-dependent. The radioactivity concentration in tumor cells varied from 10 to 33% of the total activity (105-310 cpm/1000 cells) following a 30-min incubation at 37 degrees C (pH 7.4). In comparison, accumulation of the radiopharmaceuticals into normal brain and pancreatic tissue remained relatively low. Depolarizing the plasma membrane potential in high K+ buffer significantly altered the radioactivity concentration in the tumor cells, suggesting that membrane potential plays a certain role in the cellular uptake. Competitive inhibition experiments with specific amino acid transport inhibitors indicated that the uptake of IAPA, IPA and IMT into human pancreatic carcinoma and glioblastoma cells is predominantly mediated by the L and ASC transport systems, while no substantial involvement of the transport system A in their tumor uptake could be demonstrated. In contrast, results of the present investigation indicated that ITIC is not taken up into tumor cells via the common neutral amino acid carrier systems, including the A, L and ASC system. Furthermore, preloading with naturally occurring L-amino acids failed to stimulate the cellular uptake of the radiopharmaceuticals. These data indicate that the investigated radiopharmaceuticals exhibit interesting characteristics with promise for in vivo tumor investigations to ascertain their potential as radioligands for glioma and pancreatic carcinoma imaging by SPET.

Amino Acids↗

Paroxysmal nocturnal hemoglobinuria: insights from recent advances in molecular biology.

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired hemolytic anemia characterized by the increased sensitivity of red cells to complement, leading to intravascular hemolysis and hemoglobinuria. Other clinical features are cytopenias caused by bone marrow failure and an increased risk of thrombosis. If unrecognized and not treated appropriately, PNH is often associated with a substantial morbidity and mortality. PNH is caused by the expansion of a hematopoietic progenitor cell that caries a somatic mutation in the X-linked phosphatidylinositol glycan complementation group A (PIGA) gene. The PIGA gene encodes a protein essential in the biosynthesis of glycosylphosphatidylinositol (GPI)-anchor molecules. A proportion of blood cells from patients with PNH is therefore deficient in all GPI-linked surface proteins. Considerable progress in the field of PNH research in the last 7 years has resulted from the cloning of the PIGA gene. The purpose of the current article is to describe the structure and function of the PIGA gene, to summarize the lessons learned from the analysis of PIGA gene mutations, to review the impact of mouse models on our current understanding of the human disease, and to discuss the possible pathogenesis of PNH. In addition, we will outline novel approaches to PNH diagnosis, research, and therapy that became available thanks to the cloning of the PIGA gene.

Animals↗

Isoflurane and sevoflurane anesthesia in pigs with a preexistent gas exchange defect.

BACKGROUND: Decreased arterial partial pressure of oxygen (PaO2) during volatile anesthesia is well-known. Halothane has been examined with the multiple inert gas elimination technique and has been shown to alter the distribution of pulmonary blood flow and thus PaO2. The effects of isoflurane and sevoflurane on pulmonary gas exchange remain unknown. The authors hypothesized that sevoflurane with a relatively high minimum alveolar concentration (MAC) would result in significantly more gas exchange disturbances in comparison with isoflurane or control. METHODS: This study was performed in a porcine model with an air pneumoperitoneum that generates a reproducible gas exchange defect. After a baseline measurement of pulmonary gas exchange (multiple inert gas elimination technique) during propofol anesthesia, 21 pigs were randomly assigned to three groups of seven animals each. One group received isoflurane anesthesia, one group received sevoflurane anesthesia, and one group was continued on propofol anesthesia (control). After 30 min of volatile anesthesia at 1 MAC or propofol anesthesia, a second measurement (multiple inert gas elimination technique) was performed. RESULTS: At the second measurement, inert gas shunt was 15 +/- 3% (mean +/- SD) during sevoflurane anesthesia versus 9 +/- 1% during propofol anesthesia (P = 0.02). Blood flow to normal ventilation/perfusion (V(A)/Q) lung areas was 83 +/- 5% during sevoflurane anesthesia versus 89 +/- 1% during propofol anesthesia (P = 0.04). This resulted in a PaO2 of 88 +/- 11 mmHg during sevoflurane anesthesia versus 102 +/- 15 mmHg during propofol anesthesia (P = 0.04). Inert gas and blood gas variables during isoflurane anesthesia did not differ significantly from those obtained during propofol anesthesia. CONCLUSIONS: In pigs with an already existent gas exchange defect, sevoflurane anesthesia but not isoflurane anesthesia causes significantly more gas exchange disturbances than propofol anesthesia does.

Acid-Base Equilibrium↗

[Influence of single-photon emission scan duration measured with the ECAT ART PET scanner].

AIM: The aim was to study the influence of single-photon-transmission scan duration in 3D-PET on the quantitative values of attenuation coefficients and noise in transmission images and of activity concentrations and noise in attenuation corrected emission images of thorax phantom- and patient data. METHOD AND MATERIAL: Using dual collimated Cs-137 singles transmission sources (E gamma = 662 KeV, A = 2* 614 MBq) on an ECAT ART tomograph series of transmission scans of a thorax phantom were acquired pre- and post-injection of 18F. 17 patients underwent two transmission scans. The scan time of the short transmission was chosen according to the results of the phantom studies (noise of Poisson statistics less than 4%). Transmission and attenuation corrected emission images were evaluated with respect to estimated linear attenuation coefficients, noise and specific activities in organs. RESULTS: The phantom studies reveal little variation of the estimated linear attenuation coefficients as a function of scan duration. The estimates of the attenuation coefficients are found to be 1% lower than the expected values for pre- and up to 6.5% lower for post-injection transmissions. The noise level in the transmission images increases as expected for Poisson data. The noise level in the attenuation corrected emission images shows only little increase with decreasing transmission scan time whereas it is strongly influenced by a variation of emission scan time. In patient studies, less than 3% difference was found in the estimated linear attenuation coefficients as well as in the activity concentrations between short (pre or post-injection) and long transmission scans. The noise levels in transmission and emission images are 1% (pre-injection) and 4% (post-injection) higher for short transmission scans. CONCLUSION: Due to the high photon flux, single photon transmission offers good clinical performance with significantly reduced transmission scan durations (< 2 min/bed in pre-, < 4 min/bed in post-injection transmission).

Aged↗

[Radiation exposure to patients caused by single-photon transmission measurement in PET].

AIM: The aim of the study was the determination of the radiation exposure to the patient caused by single-photon transmission measurement for 3D whole-body PET. MATERIAL AND METHOD: Single-photon-transmission measurement is performed using two Cs-137 point-sources (E gamma = 662 keV, A = 2*614 MBq) on a 3D PET scanner (ECAT ART). During a simulation of a whole body transmission scan (axial length: 75 cm, 6 contigous bed positions) dose measurements with thermoluminescent dosimeters were carried out using a thorax and an abdomen phantom. Following the guidelines of the ICRU report No. 60 an estimation of the effective dose caused by a single-photon transmission measurement was calculated. RESULTS: For a total acquisition time of 360 min (6 beds with an acquisition time of 60 min per bed) the absorbed doses amounted to: surface (xyphoid) 189 microGy, heart 196 microGy, lungs 234 microGy, vertebra 240 microGy, liver 204 microGy, gonads 205 microGy, thyroid 249 microGy and bladder 185 microGy resulting in a conversion factor of 1.7*10(-4) mSv/(h*MBq). The estimation of the effective dose for a patient's transmission (acquisition time of 3.2 min per bed) yields a value of 11 microSv. An estimation of the ratio of the conversion factors for transmission measurements in single-photon- and in coincidence mode (two Ge-68/Ga-68 rod sources of 40 MBq each), respectively, resulted in a value of 0.18. The comparison of the effective doses caused by single-photon transmission and by emission measurement (injection of 250 MBq of FDG) yields a ratio of 2.3*10(-3). CONCLUSION: The radiation exposure of the patient caused by the transmission measurement for 3D whole-body-PET can be neglected. In comparison with the coincidence-transmission using uncollimated line sources of low activity the radiation exposure is still reduced using single photon trans-mission with collimated point sources of high activity.

Computer Simulation↗

Prevention of adriamycin-induced mdr1 gene amplification and expression in mouse leukemia cells by simultaneous treatment with the anti-recombinogen bromovinyldeoxyuridine.

The anti-recombinogenic substance (E)-5-(2-bromovinyl)-2'-deoxyuridine (BVDU) was tested for its ability to prevent adriamycin-induced mdr1 gene amplification and expression in mouse leukemia cells in vitro. F4-6 cells that were treated with stepwise enhanced doses of adriamycin acquired resistance against adriamycin. While 20 ng/ml adriamycin showed strong toxic effects in sensitive cells, the same dose was tolerated at the end of the long-term experiment following treatment with stepwise enhanced doses of adriamycin. In parallel experiments, 0.5 or 1 microg/ml BVDU was given together with adriamycin. BVDU prevented the formation of resistance against adriamycin treatment. Using differential PCR, the signal intensity of the mdr1a-specific band appeared markedly increased in adriamycin-resistant cells, while the signal intensities of the adriamycin + BVDU-treated cells resembled the intensity ratio of the untreated control cells. Beyond that, in resistant F4-6 cells increased expression of mdr genes was demonstrated by Northern blot analysis.

Animals↗

Evaluation of l-3-[123I]iodo-alpha-methyltyrosine SPET and [18F]fluorodeoxyglucose PET in the detection and grading of recurrences in patients pretreated for gliomas at follow-up: a comparative study with stereotactic biopsy.

Based on the results of stereotactic biopsy, we evaluated in a prospective fashion the efficiency of l-3-[123I]iodo-alpha-methyltyrosine-single-photon emission tomography (SPET) and [18F]fluorodeoxyglucose (FDG) positron emission tomography (PET) in the detection and grading of recurrences in patients previously treated for gliomas. The patient population comprised 30 individuals, nine with astrocytomas of grade II, ten with astrocytomas of grade IV, three with oligoastrocytomas of grade II, six with oligodendrogliomas of grade II and two with anaplastic oligodendrogliomas of grade III) suspected of recurrence and scheduled for further treatment. IMT SPET data were acquired using either by dual-or a triple-headed SPET camera, Multispect 2/3. FDG uptake was measured with an ECAT ART PET camera. Two independent observers classified PET and SPET images as positive or negative for tumour tissue. Uptake of FDG and IMT was evaluated visually and, in the case of IMT, also quantitatively by calculating the ratios between tracer accumulation in the lesion and the unaffected contralateral regions of reference using the region of interest (ROI) technique. The PET and SPET results were compared with the histopathological findings obtained either by stereotactic biopsy or in one case by open surgery. Glucose metabolism and amino acid uptake of recurrences of brain tumours as assessed by FDG-PET and IMT-SPET correlated highly with the histopathological findings. Based on the histopathological data, FDG-PET and IMT-SPET findings confirmed recurrence in all cases of high-grade gliomas (IV). A difference could be demonstrated in low-grade (II-III) tumour recurrences. True-positive IMT-SPET results were found in 86% of grade III and 75% of grade II recurrences, whereas FDG-PET yielded a sensitivity of 71% in tumours of grade III and 50% in those of grade II. With respect to the grade of malignancy of brain tumours at recurrence, IMT-SPET, in contrast to FDG-PET, does not permit adequate in vivo grading of non-mixed brain tumours of astrocytic or oligodendroglial origin. However, in this study FDG-PET did not permit discrimination between upgrading of low-grade oligoastrocytomas (II) into anaplastic oligodendrogliomas (III) and upgrading into glioblastomas (IV) The results of this study indicate that FDG-PET and IMT-SPET are equivalent to stereotactic biopsy in their ability to identify high-grade tumours at recurrence. IMT-SPET proved to be superior to FDG-PET in confirming low-grade recurrences. In the case of suspected progression of the grade of malignancy in ordinary gliomas, FDG-PET correlated significantly with the histopathological grading, whereas IMT-SPET did not. However, tumour grading by FDG-PET has a limitation in mixed brain tumours in that it is not possible to discriminate between progression of the oligo- versus the astrocytic tumour entity. In this case histopathological evaluation of the tumour grade remains necessary.

Adult↗

Monoclonal antibody MAb-170 for immunoscintigraphic detection of ovarian tumors.

OBJECTIVE: The technetium Tc 99m-labeled monoclonal antibody MAb-170 was designed for diagnostic use in patients with gynecologic adenocarcinoma. Our investigation was initiated to verify its usefulness for radioimmunoscintigraphy of ovarian tumors. STUDY DESIGN: Most of the 82 patients participating in this study underwent immunoscintigraphy before first-look surgery. RESULTS: Radioimmunoscintigraphy recognized 36 of 41 patients with adenocarcinoma of the ovaries, corresponding to an overall sensitivity of 88%. Specificity was 90% (38/42). The calculation of accuracy gave a result of 89% (74/83). Of 110 known lesions, 92 were visualized successfully; thus the local-regional sensitivity was 84%. Of 160 benign tumor sites, 154 showed no evidence of tracer accumulation, corresponding to a local-regional specificity of 96%. The smallest lesion visualized was an adenocarcinoma of the corpus uteri with a diameter of 1.5 cm. CONCLUSION: The monoclonal antibody MAb-170 is a promising radiopharmaceutical for immunoscintigraphy of ovarian adenocarcinoma.

Adenocarcinoma↗

Effect of processed and non-processed coffee samples on gastric potential difference. Study with healthy male Helicobacter pylori-positive and Helicobacter pylori-negative volunteers.

In an open trial with 18 healthy male volunteers (21-45 years old) the effect of processed (test) and non-processed (reference) coffee samples of same origin on the gastric potential difference (GPD) was studied. Test coffee samples were processed with the patented "Darboven improvement procedure" before roasting. All treatment groups were subdivided according to the Helicobacter pylori status of the volunteers. The evaluation of the target parameters Reizindex (RI), area under the baseline (AUB), maximum potential difference (Pdmax) and total time (ttot) revealed a significant lower RI (p = 0.0282) and AUB (p = 0.0136), and a significant shorter ttot (p = 0.0286) for the processed coffee. Total cholesterol, high-density lipoprotein (HDL) cholesterol, and pancreatic peptides showed a comparable marked increase of the arithmetic mean with both coffee samples, however, being more intense in the Helicobacter pylori-positive subgroup than in the Helicobacter pylori-negative subgroup. No negative findings concerning tolerability and safety could be seen. In conclusion, the test coffee samples processed with a new method to improve the stomach mucosal irritation-potential of coffee charges revealed a remarkably lower stomach mucosal irritation.

Adult↗

Improved labelling of no-carrier-added 123I-MIBG and preliminary clinical evaluation in patients with ventricular arrhythmias.

Meta-[123I]iodobenzylguanidine (123I-MIBG) is currently used to assess myocardial sympathetic innervation by single photon emission tomography (SPET). In recent studies, an enhanced cardiac uptake of 123I-MIBG with high specific activity has been reported, suggesting the clinical potential of no-carrier-added (n.c.a.) 123I-MIBG in the assessment of abnormalities in cardiac sympathetic function. This paper describes the preparation of n.c.a. 123I-MIBG by non-isotopic Cu(I)-assisted [123I]iododebromination and by [123I]iododestannylation, both resulting in n.c.a. 123I-MIBG with radiochemical yields of 88 +/- 6% and high specific activity (> or = 6.3 TBq.mumol-1) in a total synthesis time of less than 50 min. The diagnostic potential of n.c.a. 123I-MIBG (> 6.3 TBq.mumol-1) was studied in 13 patients (nine patients with malignant ventricular arrhythmias and four patients suspected of phaeochromocytoma) and compared to commercial 123I-MIBG (approximately 75 MBq.mumol-1) using a dual-headed SPET camera (MULTISPECT II). High specific activity results in higher 123I-MIBG uptake in the heart and in the liver in all patients. The calculated heart-to-lung and heart-to-liver count ratios 4.5 h post-injection increased by 22 +/- 6% and 10 +/- 5% with n.c.a. 123I-MIBG compared to commercial 123I-MIBG respectively. In contrast, no significant correlation between the specific activity of 123I-MIBG and lung uptake could be established in this study. Analysis of radioactivity in blood after the intravenous injection of n.c.a. and commercially available 123I-MIBG showed an initial rapid clearance of radioactivity from blood, followed by a plateau from 60 min onwards. Within the first 24 h, more than 85% of the plasma activity was unchanged 123I-MIBG. The free 123I-iodide concentration determined 24 h post-injection was 2 +/- 1% with commercial 123I-MIBG and 3 +/- 2% with n.c.a. 123I-MIBG. In conclusion, the results of this investigation indicate that n.c.a. 123I-MIBG is a promising clinical tool for imaging myocardial sympathetic dysfunction by SPET. High specific activity n.c.a. 123I-MIBG can now be prepared by simple one-step methods giving high radiochemical yields and high purity suitable for clinical application. This encourages the further clinical validation of n.c.a. 123I-MIBG on a large scale.

3-Iodobenzylguanidine↗

[Radiation exposure of the patient caused by transmission measurement for myocardial perfusion SPECT].

AIM: The aim was the determination of the radiation exposure to the patient caused by the transmission measurement for myocardial perfusion SPECT. METHOD AND MATERIAL: Beside the emission measurement (Tc-99m-MIBI, A = 500 MBq) the myocardial perfusion SPECT simultaneously includes a transmission measurement using a Am-241-line source (A = 5550 MBq). During a simulation of the myocardial perfusion SPECT (without Tc-99m-MIBI) dose measurements with thermoluminescent dosimeters were carried out using a thorax phantom. RESULTS: For an acquisition time of 20 min the absorbed doses amounted to: surface (xyphoid) 30 microGy, heart 25 microGy, lung 14 microGy, second thoracic vertebra 16 microGy, upper anterior mediastinum 16 microGy, liver 0 microGy. An estimation of the ratio of the effective doses caused by the transmission and the emission measurement of 3.6 x 10(-3) and 4.1 mSv, respectively, resulted in a value of 9 x 10(-4). CONCLUSION: The radiation exposure of the patient caused by the transmission measurement can be neglected, and is therefore not a limiting factor regarding the general application of transmission measurement for clinical myocardial perfusion SPECT.

Heart↗

Stimulation of the Ca2+-mediated egr-1 and c-fos expression in murine erythroleukaemia cells by cyclosporin A.

The Ca2+-induced expression of the primary response genes egr-1 and c-fos was investigated in the murine erythroleukaemia cell line ELM-I-1. Exposure of the cells to the Ca2+-ionophore A23187 led to a rapid transient rise in egr-1 and c-fos mRNA production followed by an increase in Egr-1 and c-Fos protein levels as well as an increase in Egr-1 and activator protein 1 (AP-1) DNA-binding activity. Preincubation of the cells with KN-62, a specific inhibitor of Ca2+/calmodulin-dependent protein kinases, strongly decreased the Ca2+-mediated expression of egr-1 and c-fos. In contrast, treatment with cyclosporin A, which inhibits the Ca2+/calmodulin-dependent protein phosphatase 2B or calcineurin, increased both egr-1 and c-fos mRNA production and the DNA-binding activity of the Egr-1 and AP-1 transcription factors in response to the intracellular Ca+ concentration ([Ca2+]i)-increasing agents A23187 or cyclopiazonic acid. Enhancement of the Ca2+-induced c-fos and egr-1 expression by cyclosporin A was correlated with the capability of this agent to inhibit calcineurin phosphatase activity in ELM-I-1 cells. Studies on the phosphorylation state and DNA-binding activity of the cAMP response element-binding protein (CREB) did not demonstrate an early Ca2+-dependent activation of this transcription factor, suggesting that the regulation of c-fos and egr-1 expression by Ca2+ is not linked to CREB in the haematopoietic ELM-I-1 cells. The results indicate that calcineurin exerts negative regulatory effects on both egr-1 and c-fos expression in murine erythroleukaemia cells, in addition to the calcineurin-mediated down-regulation of c-myb expression observed previously in this cell system. This study therefore emphasizes the important role of calcineurin as a negative modulator of gene expression in certain cell types.

Animals↗

[Contribution of nuclear medicine to the diagnosis of recurrent brain tumors and cerebral radionecrosis].

The evaluation of brain tumor recurrence and therapy-induced benign changes following surgery and/or irradiation is a diagnostic challenge for imaging methods based on either morphology (cCT/MRI) or function (SPECT/PET). Current literature and the present data of our own patients demonstrate the diagnostic efficiency of IMT-SPECT and FDG-PET in the detection of recurrence and in-vivo grading. Thirty-nine patients suspected of brain tumor recurrence at follow-up were studied by FDG-PET and IMT-SPECT. Thirty-four of 39 patients showed recurrences; in 12 cases even a change in the grade of malignancy was observed. All high-grade recurrences could be confirmed by either methods. IMT-SPECT showed a higher sensitivity in detecting low-grade tumors at recurrence. In contrast to IMT-SPECT, FDG-PET supports sufficient in-vivo grading. Both methods can be used to differentiate between tumor recurrence and radionecrosis. In conclusion the results of our study demonstrate the efficiency of IMT-SPECT and FDG-PET in confirming recurrences and determining the actual tumor grade.

Adult↗

Erythrocytes participate significantly in blood transport of amino acids during the post absorptive state in normal humans.

To investigate the participation of erythrocytes in the blood transport of amino acids during the course of intestinal absorption in humans, erythrocyte and plasma amino-acid concentrations were determined following ingestion of an oral load of amino acids. In addition to baseline plasma and erythrocyte amino acid concentrations in 18 subjects, plasma and erythrocyte amino acids kinetics during the 125 min following an oral amino acid load were further determined in 9 of the 18 subjects. The results showed that human erythrocytes contained most amino acids at similar or higher concentrations than plasma. Furthermore, the correlations observed between plasma and erythrocyte contents clearly indicated that erythrocytes were involved in the transport of amino acids by the blood. For some amino acids erythrocyte transport sometimes exceeded that of plasma. Significant correlation coefficients showed that strong plasma-erythrocyte relationships existed for alanine, valine, methionine, isoleucine, leucine, phenylalanine, and ornithine. In conclusion, our data supported the hypothesis that both blood compartments, plasma and erythrocytes, are involved significantly in the blood transport of amino acids in humans during the postabsorptive state.

Adolescent↗

Role of the plasma and erythrocytes in veno-arterial portal changes during post prandial state in the rat.

The determination of plasma and whole blood free amino acid concentrations in arterial and portal venous blood during post prandial state in the rat was used to estimate the role of the erythrocytes in amino acid exchanges. The erythrocyte contents were calculated from plasma, whole blood concentrations and the hematocrit. The veno-arterial concentration differences in plasma were significant for all amino acids except a-aminobutyrate and ornithine whereas in the erythrocytes only 8 amino acids exhibit significant differences (ASP, ALA, VAL, MET, ILE, LEU, TYR, PHE). For 6 amino acids, a significant correlation between the plasma and the erythrocyte concentration has been found (VAL, ILE, LEU, TYR, PHE, HIS). These data suggest that in vivo during the time of contact between blood and organ tissues, some amino acids but not all are significantly taken up by the erythrocytes. Thus, it may be concluded that erythrocyte amino acid blood transport in arterio-venous portal exchanges, concerns particularly tyrosine and essential amino acids. The erythrocyte amino acid transport represents quantitatively about 20 per cent of the total blood transport.

Amino Acids↗