Stability, specificity and fluorescence brightness of multiply-labeled fluorescent DNA probes.

In this work, we studied the fluorescence and hybridization of multiply-labeled DNA probes which have the hydrophilic fluorophore 1-(straightepsilon-carboxypentynyl)-1'-ethyl- 3,3,3', 3'-tetramethylindocarbocyanine-5,5'-disulfonate (Cy3) attached via either a short or long linker at the C-5 position of deoxyuridine. We describe the effects of labeling density, fluorophore charge and linker length upon five properties of the probe: fluorescence intensity, the change in fluorescence upon duplex formation, the quantum yield of fluorescence (Phif), probe-target stability and specificity. For the hydrophilic dye Cy3, we have demonstrated that the fluorescence intensity andPhifare maximized when labeling every 6th base using the long linker. With a less hydrophilic dye, a labeling density this high could not be achieved without serious quenching of the fluorescence. The target specificity of multiply-labeled DNA probes was just as high as compared to the unmodified control probe, however, a less stable probe-target duplex is formed that exhibits a lower melting temperature. A mechanism that accounts for this destabilization is proposed which is consistent with our data. It involves dye-dye and dye-nucleotide interactions which appear to stabilize a single-stranded conformation of the probe.

Carbocyanines↗

Molecular mechanism controlling the incorporation of fluorescent nucleotides into DNA by PCR.

The efficiency and yield of incorporation of fluorescent nucleotides into DNA by polymerase chain reaction (PCR) have been investigated with linear amplification (PCR with single-stranded template and single primer). In the present study, we prepared single-stranded templates with defined sequences and used dUTP attached to the fluorescent label with linkers of different lengths. Incorporation and yield of the modified dUTP were reduced when the sequence demanded that multiple dyes be inserted at adjacent sites. The interactions between the polymerase and cyanine-labeled sites on the extending strand probably terminated the chain extension. Thus, because labeling density was increased, the yield of PCR was reduced. We also found that the interactions between the primer and dye-labeled sites on template disturb primer annealing and lead to a decrease in PCR yield.

Base Sequence↗

Automatic multiparameter fluorescence imaging for determining lymphocyte phenotype and activation status in melanoma tissue sections.

A system has been developed that combines multiparameter fluorescence imaging and computer vision techniques to provide automatic phenotyping of multiple cell types in a single tissue section. This system identifies both the nuclear and cytoplasmic boundary of each cell. A routine based on the watershed algorithm has been developed to segment an image of Hoechst-stained nuclei with an accuracy of greater than 85%. Deformable splines initially positioned at the nuclear boundaries are applied to images of fluorescently labelled cell-surface antigens. The splines lock onto the peak fluorescence signal surrounding the cell, providing an estimate of the cell boundary. From measurements acquired at this boundary, each cell is classified according to antigen expression. The system has been piloted in biopsies from melanoma patients participating in a clinical trial of the antibody R24. Thin tissue sections have been stained with Hoechst and three different fluorescent antibodies to antigens that permit the typing and evaluation of activity of T-cells. Changes in the infiltrates evaluated by multiparameter imaging were consistent with results obtained by immunoperoxidase analysis. The multiparameter fluorescent technique enables simultaneous determination of multiple cell subsets and can provide the spatial relationships of each cell type within the tissue.

Antigens, CD↗

Tumor labeling in vivo using cyanine-conjugated monoclonal antibodies.

Far-red-emitting cyanine fluorochromes have many properties desirable for in vivo imaging: absorption and emission at wavelengths where blood and tissue are relatively transparent, high quantum yields, and good solubility even at high molar ratios of fluorochrome to antibody. Potentially, conjugation by multiple linkages should minimize hydrolysis in vivo. We conjugated two tumor-targeting monoclonal antibodies: anti-SSEA-1 (IgM, kappa) at ratios of 1.2-35 mol dye/mol antibody and 9.2.27 (IgG2a, kappa) at 0.6-6 mol dye/mol antibody, using the cyanine fluorochromes Cy3.18, Cy5.18, and Cy5.5.18. Nude mice were inoculated using the SSEA-1-expressing MH-15 teratocarcinoma or the 9.2.27 antigen-expressing SK-MEL-2 melanoma to give tumors at several sites. Conjugated antibody was injected, and mice were imaged immediately after injection and at appropriate intervals thereafter using a standard camera lens, dissecting microscope, or endoscopes. Images were acquired using either an image-intensified video camera or cooled CCD cameras. Immediately after injection, major blood vessels and the heart, liver, and kidneys were readily visualized. After 1 day, tumor-targeting antibody conjugates were concentrated in tumors and there was little circulating conjugate; however, the bladder and kidneys were still visible. Tumors labeled by specific antibody were the most fluorescent tissues at 2 days after injection, but non-specific antibody conjugates did not concentrate in the tumors. The small intestine was weakly visualized by both specific and non-specific antibody conjugates. These data support the possibility of visualizing tumor metastasis by optical means, including currently available endoscopes.

Animals↗

Directly labeled DNA probes using fluorescent nucleotides with different length linkers.

Directly labeled fluorescent DNA probes have been made by nick translation and PCR using dUTP attached to the fluorescent label, Cy3, with different length linkers. With preparation of probes by PCR we find that linker length affects the efficiency of incorporation of Cy3-dUTP, the yield of labeled probe, and the signal intensity of labeled probes hybridized to chromosome target sequences. For nick translation and PCR, both the level of incorporation and the hybridization fluorescence signal increased in parallel when the length of the linker arm is increased. Under optimal conditions, PCR yielded more densely labeled probes, however, the yield of PCR labeled probe decreased with greater linear density of labeling. By using a Cy3-modified dUTP with the longest linker under optimal conditions it was possible to label up to 28% of the possible substitution sites on the target DNA with reasonable yield by PCR and 18% by nick translation. A mechanism involving steric interactions between the polymerase, cyanine-labeled sites on template and extending chains and the modified dUTP substrate is proposed to explain the inverse correlation between the labeling efficiency and the yield of DNA probe synthesis by PCR.

Carbocyanines↗

Cyanine dye dUTP analogs for enzymatic labeling of DNA probes.

Fluorescence in situ hybridization (FISH) has become and indispensable tool in a variety of areas of research and clinical diagnostics. Many applications demand an approach for simultaneous detection of multiple target sequences that is rapid and simple, yet sensitive. In this work, we describe the synthesis of two new cyanine dye-labeled dUTP analogs, Cy3-dUTP and Cy5-dUTP. They are efficient substrates for DNA polymerases and can be incorporated into DNA probes by standard nick translation, random priming and polymerase chain reactions. Optimal labeling conditions have been identified which yield probes with 20-40 dyes per kilobase. The directly labeled DNA probes obtained with these analogs offer a simple approach for multicolor multisequence analysis that requires no secondary detection reagents and steps.

Base Sequence↗

A novel fluorescence ratiometric method confirms the low solvent viscosity of the cytoplasm.

Two homologous indocyanine dyes, Cy3.18 and Cy5.18, can be used as a ratio pair for fluorometric determination of solvent viscosity. Succinimidyl ester derivatives of these dyes can be attached to inert carrier macromolecules, such as Ficoll 70, for measurement of intracellular or intravesicular solvent viscosity. When the viscosity of the solvent was varied by various methods, the fluorescence intensity ratio (Cy3/Cy5) in a mixture of Cy3.18-Ficoll 70 (Cy3F70) and Cy5.18-Ficoll 70 (Cy5F70) in solution was found to be solely a function of solvent viscosity and was insensitive to other solvent parameters such as dielectric constant, temperature, and the ability of the solvent to form hydrogen bonds. Most important, it was insensitive to the presence of large macromolecules, such as proteins, which increase the shear viscosity but have little effect on solvent viscosity. Following microinjection into the cytoplasm of living tissue culture cells, no binding of Cy3F70 or Cy5F70 to intracellular components was detected by fluorescence recovery after photobleaching. Fluorescence intensity ratio imaging of Cy3F70 and Cy5F70 in non-motile interphase CV1 and PtK1 cells showed that the solvent viscosity of cytoplasm was not significantly different from water and showed no spatial variation.

Biophysical Phenomena↗

A photocross-linking fluorescent indicator of mitochondrial membrane potential.

Ionic dyes that distribute across membranes according to electrical potential have proven valuable as fluorescent indicators of mitochondrial energetics in living cells. Applications have been limited, however, as potential-dependent staining is lost during cell fixation. We have produced a membrane potential indicator whose potential-dependent distribution can be made permanent, to enable correlation of membrane potential with cytochemical information from immunofluorescence. A carbocyanine dye was derivatized with a photoreactive nitrophenylazide moiety so that irradiation would induce nonspecific, covalent attachment to nearby molecules. Photo-induced cross-linking was observed in paper chromatography, when irradiation caused immobilization of the dye. The new dye, named PhoCy (photofixable cyanine), showed specific staining of mitochondria in living Swiss 3T3 fibroblasts. When living cells were stained, irradiated, and fixed with formaldehyde, mitochondrial staining was retained owing to cross-linking with mitochondrial components. Omission of irradiation eliminated mitochondrial staining in fixed cells. Labeling, irradiation, and fixation procedures were optimized to produce bright specific staining with minimal background. The indicator's sensitivity to mitochondrial potential was demonstrated by treating cells with 2,4-dinitrophenol, an uncoupler of mitochondrial electron transport, which decreased mitochondrial staining in living cells and in the corresponding fixed specimens.

3T3 Cells↗

Imaging cytometry by multiparameter fluorescence.

A system is described for performing multicolor fluorescence image cytometry of cell preparations. After the setting up stage, the operation is automatic: the microscope fields are found and focused; then images are acquired for each fluorophore, corrected and analyzed, without any operator interaction. Human peripheral blood lymphocytes on microscope slides were used as a test system. In these experiments, three fluorescent antibodies were used to identify lymphocyte sub-populations, and a DNA content probe was used to identify all nucleated cells. The cell subset percentages determined by image cytometry were comparable to percentages obtained when cells from the same preparation were analyzed by flow cytometry. Multicolor fluorescence imaging cytometry can potentially be extended to the analysis of cells in smears, fine needle biopsies, imprints, and tissue sections.

Algorithms↗

A calcium-sensitive fluorescent analog of calmodulin based on a novel calmodulin-binding fluorophore.

Structure-activity studies of tetramethinemerocyanine fluorophores enabled the synthesis of novel dyes which showed spectral changes during reversible, calcium-dependent association with calmodulin. These spectral changes were greatly enhanced in dyes with a quaternary nitrogen and specifically placed hydrophobic chains. One such dye was covalently attached to calmodulin, producing a calmodulin analog with calcium-sensitive fluorescence. The analog, MeroCaM, showed a calcium-induced 3.4-fold increase in excitation ratio (608/532 nm excitation, 623 nm emission), which was fully reversed by lowering free calcium levels. MeroCaM's excitation ratio showed a half-maximal change at 300-400 nM calcium, below calcium concentrations reported to produce half-maximal saturation of calcium-calmodulin binding. However, the calcium dependence of MeroCaM's phosphodiesterase activation paralleled that of calmodulin. MeroCaM's fluorescence changes therefore appear to reflect primarily calcium binding to high affinity sites. MeroCaM's maximal phosphodiesterase activation was 30-40% that of calmodulin. In myosin light chain kinase activation, MeroCaM and calmodulin displayed indistinguishable maximal activation levels and concentration dependence of activation. Changes in MeroCaM's calcium affinity induced by magnesium, phosphodiesterase, and melittin were similar to those reported for calmodulin. Experiments with melittin revealed that target protein interaction could alter the fluorescence changes produced by calcium binding. MeroCaM showed promising brightness and photostability when imaged in individual living fibroblasts. The long excitation and emission wavelengths of MeroCaM, and the strong dependence of its excitation ratio on calcium concentrations, suit it well for use as a probe of calmodulin-dependent calcium signaling in living cells, as well as for experiments in vitro.

3',5'-Cyclic-AMP Phosphodiesterases↗

Cyanine dye labeling reagents--carboxymethylindocyanine succinimidyl esters.

Ten carboxymethylindocyanine dyes which form the basis of a new series of fluorescent probes have been synthesized and converted into succinimidyl active esters for fluorescent labeling of proteins or other amino-containing substances. Fluorescence emission maxima for members of the series range from 575 to 780 nm. Hydrophilic, water-soluble reagents have been obtained which yield labeled antibodies with little tendency to form precipitates. The fluorescence intensities achieved are higher than those produced by labeling with the cyanine isothiocyanates described previously (Mujumdar et al.: Cytometry 10:11-19, 1989). The utility of these reagents has been demonstrated in antibody labeling for two-color immunofluorescent imaging of internal structures in a mammalian cell and for two-color flow-cytometry experiments. The use of values of chromophore-equivalent weight (W/Ceq), calculated from quantitative absorption data on dye samples, is proposed as an aid in formulating labeling procedures.

Animals↗

Use of 4-heptylumbelliferyl-beta-D-glucoside to identify Gaucher's disease heterozygotes.

Three fluorometric beta-glucosidase assays were compared for their ability to identify Gaucher's disease heterozygotes, using leukocytes as the source of enzyme: the pH 5.5-taurocholate assay of Peters et al.; the conduritol B epoxide dependent variation of that assay; and the newly developed method described herein. While the first two procedures utilize the standard substrate 4-methylumbelliferyl-beta-D-glucopyranoside to estimate beta-glucosidase activity, the new assay uses 4-heptylumbelliferyl-beta-D-glucoside as (C7UGlc) substrate. Use of this substrate enhances the specificity of the method for lysosomal glucocerebrosidase, thereby minimizing the contribution of the nonspecific cytosolic beta-glucosidase to estimates of substrate hydrolysis. Using Student's t test for the three assays examined, the C7UGlc assay procedure was determined to have the lowest p value (p less than 0.001) and highest t value (t = 4.95) for the discrimination between the mean glucocerebrosidase value of control and obligate Gaucher heterozygote samples. The high reliability and simplicity of the C7UGlc assay lends adequate reason to favor this assay for regular clinical diagnosis of Gaucher heterozygotes.

Brain↗

Cyanine dye labeling reagents for sulfhydryl groups.

Cyanine and merocyanine dyes are introduced as new fluorescent reagents for covalently labeling proteins and other biomolecules. These dyes, which contain iodoacetamide functional groups, have high extinction coefficients and moderate quantum yields. A major advantage of these polymethine dyes is the easy manipulation of their spectral properties during synthesis. Cyanines containing reactive functional groups can be made with absorption maxima ranging from less than 500 nm to greater than 750 nm. This property opens additional regions of the spectrum for experiments involving the simultaneous multicolor analysis of different fluorescent probes. The cyanines, which are relatively insensitive to solvent property changes, are complemented by the merocyanines, which are keen indicators of solvent polarity.

Carbocyanines↗

Cyanine dye labeling reagents containing isothiocyanate groups.

New isothiocyanate derivatives of cyanine dyes were synthesized as fluorescent covalent labeling reagents for proteins and other biomolecules. These dyes have maximum absorbance in the red and near infrared regions of the spectrum, have high extinction coefficients and have adequate quantum yields. Incorporating two alkyl sulfonate groups in the dye structures increases their water solubility, which is beneficial for labeling biological molecules in aqueous solution. Reactivities of proteins with these new cyanines are similar to their reactivities with fluorescein isothiocyanate. These new labeling reagents are complementary to the fluorescein and rhodamine reagents, expanding the possibilities of multicolor analyses. Sheep anti-mouse-IgG antibody was labeled with a pentamethine cyanine dye (CY5.8-ITC) and used with a fluoresceinated antibody as a second reagent for detecting human T-cell subsets by flow cytometry.

Antibodies↗

Calcium signals recorded from two new purpurate indicators inside frog cut twitch fibers.

Two new Ca indicators, purpurate-3,3'diacetic acid (PDAA) and 1,1'-dimethylpurpurate-3,3'diacetic acid (DMPDAA), were synthesized and used to measure Ca transients in frog cut muscle fibers. These indicators are analogues of the purpurate components of murexide and tetramethylmurexide, in which two acetate groups have been incorporated into each molecule to render it membrane impermeant. The apparent dissociation constant for Ca is 0.95 mM for PDAA and 0.78 mM for DMPDAA. One of the indicators was introduced into a cut fiber, which was mounted in a double Vaseline-gap chamber, by diffusion from the end-pool solutions. The time course of indicator concentration, monitored optically in the middle of the fiber in the central-pool region, suggests that 19% of the PDAA or 27% of the DMPDAA became bound or sequestered inside the fiber. In resting fibers, the absorbance spectrum of either indicator was well fitted by the indicator's [Ca] = 0 mM cuvette absorbance spectrum, which is consistent with the idea that PDAA and DMPDAA do not enter the sarcoplasmic reticulum as tetramethylmurexide appears to be able to do (Maylie, J., M. Irving, N.L. Sizto, G. Boyarsky, and W. K. Chandler, 1987. Journal of General Physiology. 89:145-176). After an action potential, the absorbance of either indicator underwent a rapid and transient change that returned to the prestimulus baseline within 100-200 ms. The amplitude of this change had a wavelength dependence that matched the indicator's Ca-difference spectrum. The average amplitude of peak free [Ca] was 21 microM (PDAA or DMPDAA) if all the indicator inside a fiber was able to react with Ca as in cuvette calibrations, and was 26 (PDAA) or 28 microM (DMPDAA) if only freely diffusible indicator could so react. These results suggest that PDAA and DMPDAA are the first Ca indicators that provide a reliable estimate of both the amplitude and time course of (the spatial average of) free [Ca] in a twitch muscle fiber after an action potential.

Action Potentials↗

Impermeant potential-sensitive oxonol dyes: II. The dependence of the absorption signal on the length of alkyl substituents attached to the dye.

We have measured the potential-dependent light absorption changes of 43 impermeant oxonol dyes with an oxidized cholesterol bilayer lipid membrane system. The size of the signal is strongly dependent on the chain length of alkyl groups attached to the chromophore. Dye molecules with intermediate chain lengths give the largest signals. To better understand the dependence of the absorbance signal on alkyl chain length, a simple equilibrium thermodynamic analysis has been derived. The analysis uses the free energy of dye binding to the membrane and the "on-off" model (E.B. George et al., J. Membrane Biol., 103:245-253, 1988a) for the potential-sensing mechanism. In this model, a population of dye molecules in nonpolar membrane binding sites is in a potential-dependent equilibrium with a second population of dye that resides in an unstirred layer adjacent to the membrane. Dye in the unstirred layer is in a separate equilibrium with dye in the bulk bathing solution. The equilibrium binding theory predicts a "sigmoidally shaped" increase in signal with increasing alkyl chain length, even for very nonpolar dyes. We suggest that aggregation of the more hydrophobic dyes in the membrane bathing solution may be responsible for their low signals, which are not predicted by the theory.

Adsorption↗

Impermeant potential-sensitive oxonol dyes: III. The dependence of the absorption signal on membrane potential.

We have measured potential-dependent changes in the absorption of light by oxidized cholesterol bilayer lipid membranes in the presence of impermeant oxonol dyes. The magnitude of the absorption signal increased linearly with the size of potential steps over a range of 500 mV. The signal also increased when the offset voltage of the pulse train was increased from -150 to +150 mV. The data are consistent with the "on-off" mechanism proposed by E. B. George et al. (J. Membrane Biol. 103:245-253, 1988) in which the probe undergoes potential-dependent movement between a binding site in the membrane and an aqueous region just off the surface of the membrane. An equilibrium thermodynamic analysis of the experimental data indicates that the negatively charged oxonol chromophore senses only 5-10% of the total membrane potential difference across the membrane when it is driven into a nonpolar binding site on the membrane.