Search PubMed⌕ Search

Biomedical subjects

A Rozkovec

Publications and source records attributed to A Rozkovec.

24 records · Page 2Linked to original sources

Platelet kinetics in congenital heart disease.

The survival of 111indium labelled platelets has been determined in a series of 47 subjects comprising nine with cyanotic congenital disease (Eisenmenger's syndrome), seven with congenital heart disease associated with left to right shunts, six with primary pulmonary hypertension, six with peripheral vascular disease, 11 with cardiac disorder associated with low cardiac output and eight normal volunteers. Compared with the value in the normals of 9.5 days, mean survival was significantly shortened in those with Eisenmenger's syndrome (8.4 days) and with peripheral vascular disease (8.5 days). It was normal in patients with left to right shunts (9.5 days). Gamma camera imaging in selected patients failed to reveal any abnormal sites of deposition of labelled platelets except in one patient with peripheral vascular disease who had bilateral abnormal activity in his lower limbs and a shortened platelet survival (8.0 days). From theoretical considerations, it was concluded that the reduction in platelet survival in Eisenmenger's syndrome was such that, had it been the result of pulmonary intravascular platelet deposition, abnormal activity should have been visible on chest scanning with the gamma camera. The absence of scintigraphic evidence of abnormal platelet deposition in the lungs of these patients, combined with the linear configuration of their platelet survival curves, suggests that the accelerated platelet destruction is in the reticuloendothelial (RE) system rather than intravascular. Indirect evidence in favour of increased RE destruction of platelets in Eisenmenger's syndrome was the finding of an approximate doubling of intrasplenic platelet transit time, indicating abnormal platelet pooling within the spleen.

Blood Platelets↗

Characteristics of transcutaneous oxygen tension monitors in normal adults and critically ill patients.

The performance characteristics of two transcutaneous PO2 monitors were detailed in eleven healthy adults and eighteen critically ill patients (twelve following cardiopulmonary bypass). There was no significant difference in their performance when blood was used as the calibrating medium. In critically ill patients they proved to be of value for recording short term trends in arterial PO2 rather than for measuring absolute values.

Adult↗

Evaluation of a simple device for regulating intravenous infusions.

Dial-A-Flo, an infusion control device, is assessed for accuracy, in vitro and in vivo. The unit did not permit accurate control and particularly so at lower flow rates. The normal spontaneous variations in venous pressure that occur around an infusion cannula tip, further increase the error of gravity-fed infusions. Dial-A-Flo has no advantage over a standard administration set alone, and should not be used for controlled administration of cardiac drugs.

Evaluation Studies as Topic↗