Search PubMed⌕ Search

Biomedical subjects

A Rosenfeld

Publications and source records attributed to A Rosenfeld.

At least 19 recordsLinked to original sources

Measurement and production of electron deflection using a sweeping magnetic device in radiotherapy.

The deflection and removal of high energy electrons produced by a medical linear accelerator has been attained by a Neodymium Iron Boron (NdFeB) permanent magnetic deflector device. This work was performed in an attempt to confirm the theoretical amount of electron deflection which could be produced by a magnetic field for removal of electrons from a clinical x-ray beam. This was performed by monitoring the paths of mostly monoenergetic clinical electron beams (6 MeV to 20 MeV) swept by the magnetic fields using radiographic film and comparing to first order deflection models. Results show that the measured deflection distance for 6 MeV electrons was 18 +/- 6 cm and the calculated deflection distance was 21.3 cm. For 20 MeV electrons, this value was 5 +/- 2 cm for measurement and 5.1 cm for calculation. The magnetic fields produced can thus reduce surface dose in treatment regions of a patient under irradiation by photon beams and we can predict the removal of all electron contaminations up to 6 MeV from a 6 MV photon beam with the radiation field size up to 10 x 10 cm2. The model can also estimate electron contamination still present in the treatment beam at larger field sizes.

Computer-Aided Design↗

Matchline dosimetry in step and shoot IMRT fields: a film study.

The Varian millennium 120 multileaf collimator has curved leaf ends. Transmission through the leaf ends generates a small asymmetric penumbral dose effect. This design can lead to hot spots between neighbouring beam segments during step and shoot IMRT dose delivery. We have observed some matchlines with film for clinical beams optimized using the pinnacle radiotherapy treatment planning system; hence we sought to verify the optimum leaf offset required to minimize the matchline effect. An in-house program was created to control the MLC leaf banks in 2 cm steps with a 2 cm gap. The gap was varied by the following offset values from 0.0 to 0.1 cm. Two types of radiographic films (Kodak EDR and XV films) and a radiochromic film (Gafchromic MD-55-2) were used to measure the optical density maps. The films were positioned in a solid water phantom perpendicular to the beam axis and irradiated at d(max) using a 6 MV photon beam. An ion chamber (IC4) was used to measure point doses for normalization in a beam umbral minima position. The relative mean peak to valley dose ratios measured with no leaf offset were 1.31, 1.30 and 1.31 for the XV, EDR2 and Gafchromic films, respectively. For a 0.07 cm gap per leaf and a performance of end leaf repeatability of 0.01 cm, the central matchline was reduced to about 1.0 for all dosimeters, with two mini-peaks measured as 1.05, 1.05 and 1.08 each side of the matchline, for XV, EDR2 and Gafchromic, respectively. The average relative dose across the umbra for this offset was XO-mat V = 1.01, EDR = 1.01 and radiochromic film = 1.02, respectively. While we expected the beam penumbral tails from segment neighbours to cause overprediction of the dose in the central valley regions due to the energy response of radiographic films, by normalizing all dosimeters to an ion chamber reading in the minimum we could not observe any major shape distortion between the radiographic film and radiochromic film results. In conclusion, relative doses measured by radiographic and radiochromic films agree well with IC4 within +/-2%.

Film Dosimetry↗

Intensity modulated radiation therapy: film verification of planar dose maps.

A new slow response radiographic film (Kodak EDR) is compared with a more traditional faster responding dosimetry film (Kodak XV) in an intensity modulated radiation therapy x-ray field. Dose profiles derived from the two films are compared with doses obtained using a radiotherapy dose planning system (Philips-Pinnacle) which calculates planar dose using a collapsed cone convolution algorithm. Comparisons of the dose maps delivered from film with the Pinnacle dose maps are useful to ensure accurate dose delivery. The Pinnacle dose maps agreed with measurement using both film types to within +/- 3% (in the umbral region) at depths ranging from d(max) to 15 cm. Both XV and EDR films can be used to verify IMRT. EDR film is better suited for dosimetry for combined field dose maps due to its useful dose range of 1-5 Gy. We found XV to be more suitable for individual field dose maps (dose range 0-1 Gy) as no scaling of monitor units were required to achieve acceptable optical density response.

Algorithms↗

MOSFET dosimetry for microbeam radiation therapy at the European Synchrotron Radiation Facility.

Preclinical experiments are carried out with approximately 20-30 microm wide, approximately 10 mm high parallel microbeams of hard, broad-"white"-spectrum x rays (approximately 50-600 keV) to investigate microbeam radiation therapy (MRT) of brain tumors in infants for whom other kinds of radiotherapy are inadequate and/or unsafe. Novel physical microdosimetry (implemented with MOSFET chips in the "edge-on" mode) and Monte Carlo computer-simulated dosimetry are described here for selected points in the peak and valley regions of a microbeam-irradiated tissue-equivalent phantom. Such microbeam irradiation causes minimal damage to normal tissues, possible because of rapid repair of their microscopic lesions. Radiation damage from an array of parallel microbeams tends to correlate with the range of peak-valley dose ratios (PVDR). This paper summarizes comparisons of our dosimetric MOSFET measurements with Monte Carlo calculations. Peak doses at depths <22 mm are 18% less than Monte Carlo values, whereas those depths >22 mm and valley doses at all depths investigated (2 mm-62 mm) are within 2-13% of the Monte Carlo values. These results lend credence to the use of MOSFET detector systems in edge-on mode for microplanar irradiation dosimetry.

Animals↗

Surface charging and impulsive ion ejection during ultrashort pulsed laser ablation.

We report time-resolved studies using femtosecond laser pulses, accompanied by model calculations, that illuminate the difference in the dynamics of ultrashort pulsed laser ablation of different materials. Dielectrics are strongly charged at the surface on the femtosecond time scale and undergo an impulsive Coulomb explosion. This is not seen from metals and semiconductors where the surface charge is effectively quenched.

Journal Article↗

Simulations of silicon microdosimetry measurements in fast neutron therapy.

Experimental silicon microdosimetry measurements were performed at a Fast Neutron Therapy facility. Monte Carlo based calculations of these measurements were made using the GEANT4 toolkit. Reasonable agreement between theoretical and experimental results was obtained and the contribution of elastic and inelastic reaction products to the final microdosimetric spectrum was determined.

Computer Simulation↗

Measurements in radiotherapy beams using on-line MOSFET detectors.

When acquiring data to characterise radiation beams for radiotherapy treatment planning measurements in steep dose gradients such as beam penumbra or dose build-up are often required. A metal oxide semiconductor field effect transistor (MOSFET) with its inherent high spatial resolution was used for penumbra measurements in a 120 kVp X ray beam. The customised MOSFET system features a pulsed readout that allows the acquisition of data points in user defined time intervals of less than 1 s. Using a modified scanning beam data acquisition system the penumbra was acquired on-line in 0.1 mm steps. Measurements were made at different distances behind the beam collimator. From the extrapolation of the penumbra width to a location directly under the block the spatial resolution of the MOSFET system can be estimated to be better than 0.1 mm. This excellent spatial resolution has many potential applications in radiotherapy dosimetry, including the characterisation of multileaf collimator systems.

Equipment Design↗

Statutory and regulatory recognition for clinical nurse specialists in Oregon.

Clinical nurse specialists (CNSs) in Oregon initiated the process of achieving statutory and regulatory recognition several years ago. Throughout this process, specific phases of activity and events helped CNSs to identify what was required to achieve this goal. The resulting lessons learned are shared in this report. Statutory recognition of CNSs in Oregon occurred in 1999, and the administrative rules for CNS practice were published in 2001. These administrative rules delineate the CNS scope of practice and other aspects of CNS practice consistent with national standards.

Humans↗

The ruv proteins of Thermotoga maritima: branch migration and resolution of Holliday junctions.

In homologous recombination in bacteria, the RuvAB Holliday junction-specific helicase catalyzes Holliday junction branch migration, and the RuvC Holliday junction resolvase catalyzes formation of spliced or patched structures. RuvAB and RuvC from the hyperthermophile Thermotoga maritima were expressed in Escherichia coli and purified to homogeneity. An inverted repeat sequence with unique termini was produced by PCR, restriction endonuclease cleavage, and head-to-tail ligation. A second inverted repeat sequence was derived by amplification of a second template containing a three-nucleotide insertion. Reassociation products from a mixture of these two sequences were homoduplex linear molecules and heteroduplex heat-stable Holliday junctions, which acted as substrates for both T. maritima RuvAB and RuvC. The T. maritima RuvAB helicase catalyzed energy-dependent Holliday junction branch migration at 70 degrees C, leading to heteroduplex linear duplex molecules with two three-nucleotide loops. Either ATP or ATP gamma S hydrolysis served as the energy source. T. maritima RuvC resolved Holliday junctions at 70 degrees C. Remarkably, the cleavage site was identical to the preferred cleavage site for E. coli RuvC [(A/T)TT(downward arrow)(G/C)]. The conservation of function and the ease of purification of wild-type and mutant thermophilic proteins argues for the use of T. maritima proteins for additional biochemical and structural studies.

Amino Acid Sequence↗

Needs and opportunities for improving the health, safety, and productivity of medical research facilities.

Medical research facilities, indeed all the nation's constructed facilities, must be designed, operated, and maintained in a manner that supports the health, safety, and productivity of the occupants. The National Construction Goals, established by the National Science and Technology Council, envision substantial improvements in occupant health and worker productivity. The existing research and best practices case studies support this conclusion, but too frequently building industry professionals lack the knowledge to design, construct, operate, and maintain facilities at these optimum levels. There is a need for more research and more collaborative efforts between medical and facilities engineering researchers and practitioners in order to attain the National Construction Goals. Such collaborative efforts will simultaneously support attainment of the National Health Goals. This article is the summary report of the Healthy Buildings Committee for the Leadership Conference: Biomedical Facilities and the Environment sponsored by the National Institutes of Health, the National Association of Physicians for the Environment, and the Association of Higher Education Facilities Officers on 1--2 November 1999 in Bethesda, Maryland, USA.

Air Pollution, Indoor↗

The journalist's role in bioethics.

In the late 1950s and early 1960s, emerging advances in the biomedical sciences raised insufficiently noticed ethical issues, prompting science reporters to serve as a sort of Early Warning System. As awareness of bioethical issues increased rapidly everywhere, and bioethics itself arrived as a recognized discipline, the need for this early-warning press role has clearly diminished. A secondary but important role for the science journalist is that of investigative reporter/whistleblower, as in the Tuskegee syphilis trials and the government's secret plutonium experiments. Because the general public gets most of its information from the popular media, ways are suggested for journalists and bioethicists to work together.

Bioethical Issues↗

Refining the scale-up of chromatographic separations.

The use of heavily loaded columns and complex processing conditions makes scale-up of chromatographic separations a non-trivial process. The wide ranges of process conditions that must be investigated demands that a large number of preliminary experiments must usually be made in small columns and laboratory-scale work stations. These preliminary data can be biased by improper column packing, poor distributors and dispersion in auxiliary apparatus, and it is important to understand these disturbing factors in detail. Moreover, it is precisely at this macroscopic level that our understanding of the chromatographic process is weakest, for large columns as well as small. This paper addresses three of these factors: Efficient elimination of peripheral effects and characterization of both header flow distribution and packing non-uniformity. This will be done using a variety of experimental and analytical approaches including nuclear magnetic resonance imaging, computational fluid dynamics and mass transfer, and careful experimentation.

Acetone↗

Dose response of various radiation detectors to synchrotron radiation.

Accurate dosimetry is particularly difficult for low- to medium-energy x-rays as various interaction processes with different dependences on material properties determine the dose distribution in tissue and radiation detectors. Monoenergetic x-rays from synchrotron radiation offer the unique opportunity to study the dose response variation with photon energy of radiation detectors without the compounding effect of the spectral distribution of x-rays from conventional sources. The variation of dose response with photon energies between 10 and 99.6 keV was studied for two TLD materials (LiF:Mg,Ti and LiF:Mg,Cu,P), MOSFET semiconductors, radiographic and radiochromic film. The dose response at synchrotron radiation energies was compared with the one for several superficial/orthovoltage radiation qualities (HVL 1.4 mm Al to 4 mm Cu) and megavoltage photons from a medical linear accelerator. A calibrated parallel plate ionization chamber was taken as the reference dosimeter. The variation of response with x-ray energy was modelled using a two-component model that allows determination of the energy for maximum response as well as its magnitude. MOSFET detectors and the radiographic film were found to overrespond to low-energy x-rays by up to a factor of 7 and 12 respectively, while the radiochromic film underestimated the dose by approximately a factor of 2 at 24 keV. The TLDs showed a slight overresponse with LiF:Mg, Cu, P demonstrating better tissue equivalence than LiF:Mg, Ti (maximum deviation from water less than 25%). The results of the present study demonstrate the usefulness of monoenergetic photons for the study of the energy response of radiation detectors. The variations in energy response observed for the MOSFET detectors and GAF chromic film emphasize the need for a correction for individual dosimeters if accurate dosimetry of low- to medium-energy x-rays is attempted.

Biophysical Phenomena↗

Methanococcus jannaschii flap endonuclease: expression, purification, and substrate requirements.

The flap endonuclease (FEN) of the hyperthermophilic archaeon Methanococcus jannaschii was expressed in Escherichia coli and purified to homogeneity. FEN retained activity after preincubation at 95 degrees C+ for 15 min. A pseudo-Y-shaped substrate was formed by hybridization of two partially complementary oligonucleotides. FEN cleaved the strand with the free 5' end adjacent to the single-strand-duplex junction. Deletion of the free 3' end prevented cleavage. Hybridization of a complementary oligonucleotide to the free 3' end moved the cleavage site by 1 to 2 nucleotides. Hybridization of excess complementary oligonucleotide to the free 5' end failed to block cleavage, although this substrate was refractory to cleavage by the 5'-3' exonuclease activity of Taq DNA polymerase. For verification, the free 5' end was replaced by an internally labeled hairpin structure. This structure was a substrate for FEN but became a substrate for Taq DNA polymerase only after exonucleolytic cleavage had destabilized the hairpin. A circular duplex substrate with a 5' single-stranded branch was formed by primer extension of a partially complementary oligonucleotide on virion phiX174. This denaturation-resistant substrate was used to examine the effects of temperature and solution properties, such as pH, salt, and divalent ion concentration on the turnover number of the enzyme.

Archaeal Proteins↗

Identification of electrophoretically separated proteases from midgut and hemolymph of adult Anopheles stephensi mosquitoes.

Digestion of blood within the mosquito midgut is mediated primarily by a series of proteases, and several previous studies have described protease activity within homogenates of the midgut of the malaria vector Anopheles stephensi. We have expanded on these previous data by resolving protease isoforms from the midgut as well as the hemolymph of adult An. stephensi mosquitoes via gel electrophoresis and zymography. Using this procedure, we have been able to identify multiple isozymes of trypsin, chymotrypsin, and aminopeptidase. We were able to detect an increase in the intensity of some of these protease bands plus the appearance of new bands 24 hr after mosquitoes had taken a blood meal. Furthermore, we detected 2 endogenous trypsin isozymes within the hemolymph. There was no upregulation of these hemolymph isozymes after a blood meal, thus suggesting that they may not be involved in digestion of the blood meal by the mosquito.

Animals↗

Psychiatry and children in the child welfare system.

The child welfare system is, for better or worse, an unavoidable associate of the child and adolescent psychiatrist. Although the child psychiatrist rarely plays an integral role in decision making about the children who are involved with the system, the authors point out that a large percentage of children maintained in and involved with the system have psychiatric and developmental disorders. When these children's difficulties are either minimized or unrecognized by child welfare workers, the interventions and treatment that the children receive may be inappropriate. Worse still, when the children's difficulties are improperly addressed, the vicissitudes of the system may further harm them. The authors propose several ways in which the child and adolescent psychiatrist can have an important reparative role and voice in child welfare systems.

Adolescent↗