Search PubMed⌕ Search

Biomedical subjects

A Rios

Publications and source records attributed to A Rios.

135 records · Page 8Linked to original sources

A double-blind, multicenter comparative study of two regimens of clindamycin hydrochloride in the treatment of patients with acute streptococcal tonsillitis/pharyngitis.

In a double-blind, prospective, randomized, multicenter study, 164 patients with a clinical and bacteriologic diagnosis of acute streptococcal tonsillitis/pharyngitis were enrolled to compare the efficacy and safety of two regimens of clindamycin. A rapid identification test of Group A beta-hemolytic streptococci (GABHS) was used to initiate the therapy; however, a positive tonsillar/pharyngeal culture was required at pretreatment to determine if the patient was assessable. Another culture was repeated at least 2 days after the 10 days of drug therapy. From 164 patients enrolled (mean age, 27.7 years; range, 14 to 60 years), 141 were assessable for efficacy; 22 patients were excluded because they did not have a positive culture at pretreatment and 1 patient did not complete the study due to a side effect (rash). All patients were included in the safety analysis. Patients received either clindamycin hydrochloride capsules 150 mg four times per day (QID) or clindamycin hydrochloride capsules 300 mg two times per day (BID) and placebo capsules BID for 10 days. There were no significant differences between groups in terms of demographics, medical history, and evolution of symptoms. The clinical efficacy rate in the two groups at day 12 was as follows: QID group--cured, 64 (92.8%) of 69 patients; improved, 5 (7.2%) of 69 patients; BID group--cured, 67 (93.1%) of 72 patients; improved, 5 (6.9%) of 72 patients. There were no significant differences between the groups. Both regimens were well tolerated with only 1 patient in the QID group who did not complete the therapy due to a rash.(ABSTRACT TRUNCATED AT 250 WORDS)

Acute Disease↗

Intracranial metastases from an ovarian dysgerminoma in a 2-year-old dog.

A 2-year-old, intact female rottweiler was presented for signs of lethargy. A mass was ultrasonographically observed, cranial and lateral to the left kidney. Exploratory laparotomy revealed a mass in the left ovary that was diagnosed histopathologically as an ovarian dysgerminoma. Two weeks after surgery, the dog was readmitted with signs of peripheral vestibular disease that progressed to central vestibular disease. Magnetic resonance imaging of the brain revealed the presence of a mass in the caudal fossa. The histopathological diagnosis of the mass was metastases from the ovarian dysgerminoma.

Animals↗

Administration of BCG cell wall skeleton into malignant effusions: toxic and therapeutic effects.

Thirty-nine patients with 40 refractory malignant effusions (26 pleural and 14 peritoneal) were treated locally with a nonviable mycobacterial vaccine. The vaccine was administered into the effusion and consisted of BCG cell wall skeleton and trehalose dimycolate attached to oil microdroplets. A dose range of 150--3000 microgram was tested. The overall response rate was 44.0% (complete response [CR] plus partial response [PR]) and was not clearly dose-related. The response rates for each site were 13.6% (CR) and 31.8% (PR) for pleural effusions and 33.3% (CR) and 8.3% (PR) for peritoneal effusions. Toxic effects consisted of fever (40%), serosal pain (37.5%), and increased effusion (27.5%) and were not clearly dose-related. Gastrointestinal toxic effects were seen in 50% of patients treated for peritoneal effusions. Response correlated with prior exposure to BCG vaccine or tuberculosis, and with a febrile response to vaccine administration. This vaccine has a therapeutic effect on both pleural and peritoneal effusions.

BCG Vaccine↗

Factors affecting humidity of inspired gas in a neonatal lung model.

OBJECTIVE: The American National Standards Institute recommends an absolute humidity of > or = 30 mg/L of inspired gas in patients receiving mechanical ventilation. This study was designed to assess the absolute humidity of inspired gas in relation to humidifier settings and environmental conditions in a test lung. STUDY DESIGN: Measurements were obtained at the endotracheal tube manifold of an artificial lung in an isolette or radiant warmer with use of a nonheated wired system and two different ventilator circuit lengths. Temperature and relative humidity were measured at three environmental temperatures and various humidifier settings. RESULTS: We achieved adequate absolute humidity levels only at near maximum humidifier settings. When the artificial lung was placed in an isolette with a standard circuit length inside the isolette, adequate absolute humidity was never reached at an environmental temperature of 30 degrees C. Increasing the length of the ventilator circuit situated inside the isolette or using a radiant warmer improved absolute humidity compared with that obtained with use of a standard circuit length. CONCLUSION: Recommended absolute humidity levels may not be reached at the manifold even at high humidifier settings. Thus actual measurements of relative humidity and temperature at the endotracheal tube site are necessary to optimize humidity according to American National Standards Institute recommendations.

Artificial Organs↗