A R Edison

Publications and source records attributed to A R Edison.

7 recordsLinked to original sources

Self-sterilization of the electrosurgery electrode.

Sterilization of the electrode used in electrosurgery has been assumed to occur at the instant of contact of the energized electrode tip to a grounded source. This study evaluated whether the time of electrode activation or the amount of energy delivered is important in the self-sterilization process. Standard bacteriologic culturing techniques were employed to assess sterility of the electrode tip following activation. Total time of application of the current and the energy used were recorded on audiotape and later tabulated. The data indicate that the time of energizing and the energy units used are critical in the sterilization of the electrode tip. These results confirm that self-sterilization of the electrosurgery electrode tip occurs, but full confidence is not realized with the time intervals commonly employed in clinical practice. The electrode tip must be considered a potential source of bacterial contamination of electrosurgically managed dental procedures.

Electric Conductivity↗

Histologic evaluation of gingival response to an electrosurgical blade.

Lateral heat production during the use of electrosurgical procedures in the oral cavity causes denaturation of the connective tissue adjacent to the incision line. This study evaluated the denatured zone following electrosurgery incision in dog gingiva with a traditional tungston wire electrode and a no. 15 surgical blade adapted for electrosurgery use. The effects of using a passive electrode during surgical procedures and using an "autosensor" circuit to control power adjustment were also evaluated. It was found that a surgical blade adapted for electrosurgery produces a zone of denatured tissue that is not statistically different from that produced with a wire electrode. Moreover, no differences were noted between incisions produced with manual power adjustment and those with power controlled by the "autosensor" circuit. A significantly wider zone of denatured tissue was produced when incisions were made without a passive electrode in place.

Animals↗

Lateral heat production secondary to electrosurgical incisions.

Adverse healing responses, including necrosis of soft tissue and sequestration of alveolar bone, have been reported following the use of electrosurgery for intraoral incisions. These responses are usually attributed to excessive heat accumulation during the surgical procedure. The purpose of this investigation was to measure temperature changes in subadjacent connective tissue during intraoral electrosurgical incisions in palatal mucosa of miniature swine. Results indicate that single electrosurgical incisions should be accomplished at a speed of approximately 7 mm. per second and that successive incisions should be separated by a cooling interval of 8 to 10 seconds to avoid generation of heat sufficient to initiate an adverse healing response.

Animals↗

Subjacent heat production during tissue excision with electrosurgery.

A study was designed to document heat production subjacent to tissue excision by electrosurgery. In Phase I of the study, 20 electrosurgery excisions were made with a loop electrode in the palatal mucosa of miniature swine. Subjacent heat production was measured with implantation thermistors. Temperature measurements adjacent to 20 single incisions made with a needle electrode were used for comparison. Energy used and duration of active electrode contact with the tissue were recorded for each procedure with an electronic measuring device. In Phase II, 20 sets of excisions consisting of three successive excisions were performed. The following intraexcisional cooling periods were used for four sets each: 1 second, 5 seconds, 8 seconds, 10 seconds, and 15 seconds. Results indicate that single electrosurgery excisions with a loop electrode generate more energy than incisions made with a needle electrode. Subjacent heat production, however, is not significantly different. Cooling intervals of at least 15 seconds between successive electrosurgery excisions made with a loop electrode are necessary to prevent heat build-up of a magnitude capable of initiating destructive alveolar changes.

Animals↗

Epithelial and connective tissue healing following electrosurgical incisions in human gingiva.

Electrosurgery is used for intraoral incisions by many clinicians. Much controversy surrounds the effect of lateral heat produced during the electrosurgical incision upon the healing of adjacent connective tissue. Ten electrosurgical incisions were made in the gingiva in each of five adult male volunteers. The duration of incision and actual energy production for each incision were calculated. Excisional biopsies of the incisions were obtained at 0-504 hours. At the light microscopic level, epithelium, totally degenerated immediately following the electrosurgery incision, showed extensive activity at 24-48 hours and had covered all wounds by 72 hours. Early hour specimens showed a homogenous connective tissue region, adjacent to the wound site, devoid of cells and fibers. This zone of denatured connective tissue gradually diminished until it was no longer present at 396 hours.

Adult↗

A method to measure operating variables in electrosurgery.

Variables affecting tissue response to electrosurgical wounding have been identified and discussed. An electronic measuring device was designed and built to record actual power generated at the active electrode during surgical use of an electrosurgery instrument. In addition, this electronic device measures the amount of time the active electrode is in contact with tissue. Coupled with an electrosurgery unit producing a documented waveform and an electrosurgery electrode having a controlled-depth gauge, variables affecting tissue response to electrosurgery wounding may be measured.

Electricity↗