Search PubMed⌕ Search

Biomedical subjects

A R Cross

Publications and source records attributed to A R Cross.

79 records · Page 5Linked to original sources

The purification and properties of the soluble cytochromes c of the obligate methylotroph Methylophilus methylotrophus.

The obligate methylotroph Methylophilus methylotrophus contains three distinct soluble cytochromes c. The major cytochromes, cytochrome cH (about 50% of the total) and cytochrome cL (about 42%), were similar in most respects to the cytochromes cH and cL of the facultative methylotroph Pseudomonas AM1 [O'Keeffe & Anthony (1980) Biochem. J. 192, 411-419]. Cytochrome cH had a high isoelectric point, a midpoint redox potential at pH 7.0 of 373 mV and a low molecular weight (8500). The cytochrome cL had a low isoelectric point, a midpoint potential of 310 mV and a molecular weight of 21,000. The third cytochrome, cytochrome cLM, was clearly distinct from cytochromes cH and cL. Like the cytochrome cL of Pseudomonas AM1, the cytochrome cL of M. methylotrophus had the lowest midpoint potential, it reacted most rapidly with methanol dehydrogenase and it combined to the greatest extent with CO. Cytochromes cH and L of M. methylotrophus differed from those from Pseudomonas AM1 in having unusually high midpoint redox potentials for non-photosynthetic bacteria and in exhibiting a split alpha-band at low temperatures.

Carbon Monoxide↗

Fatal infantile mitochondrial myopathy due to cytochrome c oxidase deficiency.

A case of cytochrome c oxidase deficiency primarily affecting skeletal muscle is described. The child was admitted at 4 weeks due to failure to thrive and examination at that time revealed weakness and hypotonia. His condition deteriorated until at 11 weeks respiratory arrest necessitated artificial ventilation and death occurred at 14 weeks. Biochemical investigation showed lactic acidaemia and generalised aminoaciduria. Histochemical examination of muscle obtained at biopsy showed strong reactions for some oxidative enzymes, but by contrast cytochrome c oxidase could not be detected. Cytochrome c oxidase activity was less than 5% of control values in an extract of fresh muscle. The reduced-minus oxidised absorption spectra of muscle mitochondrial fractions prepared from post-mortem tissue showed an absence of cytochrome aa3 and a partial deficiency of cytochrome b. Ultra-structural examination showed abnormal mitochondria with loss of cristae and an abnormal granular matrix. The family history suggests autosomal recessive inheritance.

Cytochrome-c Oxidase Deficiency↗

NADPH oxidase-like activity in rainbow trout Oncorhynchus mykiss (Walbaum) macrophages.

Evidence for the existence of an NADPH oxidase-like enzyme in rainbow trout macrophages is given. Reduced-minus-oxidised difference spectroscopy revealed the presence of a cytochrome b with three absorbance peaks, at 430, 533, and 558 nm. The low midpoint potential of the latter peak suggests this cytochrome is the same as the terminal component of NADPH oxidase (i.e., cytochrome b-245). Subcellular fractionation of macrophages revealed two peaks of cytochrome b activity, in accord with the concept of a plasma membrane localisation of cytochrome b activity in addition to a mitochondrial localisation. Finally, that the rainbow trout oxidase is a multicomponent enzyme was suggested by inhibitor studies, where specific inhibitors of the flavin and cytochrome b-245 components of NADPH oxidase induced significant reduction in superoxide anion production.

Acetophenones↗

Definition and determination of acetabular component orientation in cemented total hip arthroplasty.

OBJECTIVE: To describe the spatial orientation of the cemented acetabular component in cemented total hip arthroplasty, based on a ventrodorsal and lateral radiographic projection of the pelvis. METHODS: Equations were derived by using trigonometric relationships that describe the radiographic rotation about the longitudinal pelvic axis (alpha), transverse pelvic axis (beta), acetabular inclination (phi), acetabular inclination corrected for longitudinal pelvic rotation, version (phiC), acetabular version (theta), acetabular version corrected for longitudinal pelvic rotation (thetaC), acetabular inclination corrected for transverse pelvic rotation (phi(beta)), and acetabular version corrected for transverse pelvic rotation (theta(beta)) RESULTS: Alpha was calculated by using the equation alpha = sin(-1) (x/y) where x is the transverse distance between the dorsal spinous processes and the center of the pubis on a ventrodorsal radiograph and y is the distance from the pubis to the dorsal aspect of the first coccygeal vertebra perpendicular to the long axis of the pelvis on a lateral radiograph. Phi was calculated from the long axis (LA) and short axis (SA) of the ellipse formed by the radiopaque acetabular marker ring by using the equation phi = sin(-1) (SA/LA). phiC was calculated by using the equation phiC = phi +/- (alpha - tan(-1) (tan alpha cos thetaC)). Theta was determined as previously described. ThetaC was calculated by using the equation thetaC = tan(-1) (tan theta cos alpha). Theta(beta) and theta(beta) were calculated with the equations phi(beta) = tan(-1) (tan theta cos beta) and theta(beta) = theta - tan(-1) (sin beta), respectively. Beta could not be accurately determined from ventrodorsal and lateral pelvic radiographs. CONCLUSIONS AND CLINICAL RELEVANCE: These techniques allow for more accurate postoperative radiographic assessment of acetabular component positioning. This information can then be used in retrospective or prospective analyses examining that effects of implant positioning on clinical outcome.

Acetabulum↗

Acetabular component orientation as an indicator of implant luxation in cemented total hip arthroplasty.

OBJECTIVE: To determine the sensitivity and specificity with which acetabular component angles of inclination and version could be used, alone or in combination, to predict luxation of cemented total hip arthroplasties (THA). STUDY DESIGN: Comparison of retrospectively selected cases and controls SAMPLE POPULATION: All THA performed at the University of Florida between 1991 and 1998 with the BioMedtrix system and for which at least 2 months of radiographic follow-up were available. All THA performed at the University of Georgia with the BioMedtrix system which subsequently luxated. METHODS: Acetabular component inclination angle (IA) and acetabular version angle (VA) were determined for each THA. Data were grouped according to outcome - luxation or no luxation - with the luxated cases from the 2 institutions pooled. Receiver operator characteristic (ROC) analysis was used to evaluate decision rules for using IA and VA as tests for detecting postoperative luxation. Sensitivity and specificity for luxation and 95% confidence bounds were computed with selected values of IA and VA as cut-points. RESULTS: The nonluxation group consisted of 68 THA with a median follow-up time of 5 months (range, 2-60 months). The luxation group consisted of 12 THA with a mean time to luxation of 36 days. The nonluxation group had a mean +/- standard deviation (SD) IA and VA of 40.3 degrees +/- 8.9 degrees and 71.1 +/- 13.6 degrees, respectively, whereas the luxation group had a mean +/- SD IA and VA of 34.7 degrees +/- 12.6 degrees and 72.9 degrees +/- 16.6 degrees, respectively. An IA cut-point of 37.8 degrees achieved 58.3% sensitivity and 57.4% specificity. A VA cut-point of 73 degrees achieved 75.0% sensitivity and 51.5% specificity. IA and VA considered simultaneously achieved a 50.0% sensitivity and 88.2% specificity. CONCLUSIONS AND CLINICAL RELEVANCE: ROC analysis indicated that both IA and VA considered individually or simultaneously were poor indicators of luxation. Although extreme values of IA may predict luxation with high specificity, the potential for luxation cannot be excluded based on apparently appropriate values of IA and VA. The results of this study also indicate that a successful outcome is possible with a wide range of acetabular component positions.

Acetabulum↗

Axial characteristics of circular external skeletal fixator single ring constructs.

OBJECTIVE: Evaluate the effects of varying ring diameter, wire tension, and wire-divergence angle on the axial stiffness characteristics of circular external skeletal fixator single-ring constructs. Study Design-Biomechanical evaluation using circular fixator components and a Delrin cylinder bone model. METHODS: Single ring constructs using two 1.6 mm diameter Kirschner wires to secure a 19 mm Delrin cylinder centered within the ring were examined. Component variables evaluated were ring diameter (50 mm, 66 mm, 84 mm, and 118 mm), wire-divergence angle (30 degrees, 60 degrees, and 90 degrees ), and wire tension (0 kg, 30 kg, 60 kg, and 90 kg). A total of 48 constructs were examined. Rings were rigidly mounted on a universal testing system and the cylinder loaded in axial compression (7.4 N/s) to 220 N. Load/displacement curves were analyzed to determine the following: the displacement (mm) that occurred before the slope of each load/displacement curve became linear, the stiffness (N/mm) of the linear portion of each load/deformation curve, and the total displacement (mm) produced at maximal load. Least-squares linear regression was used to model response variables as linear functions of ring diameter, wire divergence angle, and wire tension. Three-way interactions and 2-way interactions among independent component variables were evaluated first in the modeling process and included in a best model if response variables were found to have statistically significant regression coefficients. The regression coefficients and corresponding standard errors and covariances were used to estimate the maximal effect and standard error attributable to wire divergency angle (change from 30 degrees to 90 degrees ) and wire tension (change from 0 to 90 kg) for each ring diameter. RESULTS: All load/deformation curves had an initial exponential increase in stiffness, with the slope becoming linear at higher loads. The exponential phase was more pronounced in larger-diameter ring constructs and was mitigated by tensioning the wires. Ring diameter had the greatest influence on displacement that occurred before the curve became linear (semipartial r(2) [sp-r2] = .89), stiffness (sp-r2 = .94), and total displacement (sp-r2 = .93). Wire tension exerted a smaller influence on displacement that occurred before the curve became linear (sp-r2 =.06), stiffness (sp-r2 = .03), and total displacement (sp-r2 = .05). Wire divergence angle had a nominal effect on displacement that occurred before the curve became linear (sp-r2 = .0001), on stiffness (sp-r2 = .004), and on total displacement (sp-r2 =.003). CONCLUSIONS: Ring diameter had a profound effect on the axial stiffness characteristic of single ring constructs. Tensioning of the fixation wires can improve the axial stiffness characteristics of these constructs, particularly in larger diameter ring constructs, by mitigating the initial exponential phase of the load/deformation curve. Wire divergence angle had only a nominal differential effect on axial stability. CLINICAL RELEVANCE: Understanding how individual component variables and their interactions influence bone segment stability should help surgeons to optimize interfragmentary strain. Tensioning fixation wires is probably unnecessary in 50 mm diameter ring constructs, but assumes greater importance as ring diameter increases.

Animals↗