Publications and source records attributed to A R Cowen.

At least 19 recordsLinked to original sources

Developments in digital radiography: an equipment update.

Digital X-ray imaging technology has advanced rapidly over the past few years. This review, particularly aimed at those involved in using and purchasing such technology, is an attempt to unravel some of the complexities of this potentially confusing subject. The main groups of X-ray imaging devices that are considered are digitisers of conventional radiographs, image-intensifier-based fluorography systems, photostimulable phosphor computed radiography, amorphous selenium-based technology for thorax imaging and flat-panel systems. As well as describing these different systems, we look at ways of objectively assessing their image quality. Concepts that are used and explained include spatial resolution, grey-scale bit resolution, signal-to-noise ratio and detective quantum efficiency. An understanding of these basic parameters is vital in making a scientific assessment of a system's performance. Image processing and techniques are also briefly discussed, particularly with reference to their potential effects on image quality. This review aims to provide a basic understanding of digital X-ray imaging technology and enables the reader to make an independent and educated assessment of the relative merits of each system.

Equipment Design↗

Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography.

This paper outlines how objective measurements of both image quality, in terms of signal-to-noise ratio, and effective dose may be used as tools to find the optimum kVp range for a digital chest radiography system. Measurements were made with Thoravision, an amorphous selenium-based digital chest X-ray system. The entrance surface dose and the effective dose to an anthropomorphic chest phantom were determined demonstrating how effective dose is related to beam quality. The image quality was measured using detective quantum efficiency, threshold contrast and a radiologist preference trial involving 100 patients. The results show that, despite the fact that the entrance surface dose decreases as the kVp increases, the effective dose, a better measure of the risk, reaches a minimum value between 90 and 110 kVp; however, the image quality decreases as the kVp increases. In this study the optimum kVp for chest radiography, using a selenium-based radiography system, is in the range 90-110 kVp. This is contrary to the 120- to 150-kVp range that is commonly used. Also, this study shows how objective measurements can be used to optimise radiographic technique without prolonged patient trials.

Radiation Dosage↗

Threshold contrast detail detectability measurement of the fluoroscopic image quality of a dynamic solid-state digital x-ray image detector.

Solid-state digital x-ray imaging detectors of flat-panel construction will play an increasingly important role in future medical imaging facilities. Solid-state detectors that will support both dynamic (including fluoroscopic) and radiographic image recording are under active development. The image quality of an experimental solid-state digital x-ray image detector operating in a continuous fluoroscopy mode has been investigated. The threshold contrast detail detectability (TCDD) technique was used to compare the fluoroscopic imaging performance of an experimental dynamic solid-state digital x-ray image detector with that of a reference image intensifier television (IITV) fluoroscopy system. The reference system incorporated Plumbicon TV. Results were presented as a threshold detection index, or H(T)(A), curves. Measurements were made over a range of mean entrance air kerma (EAK) rates typically used in conventional IITV fluoroscopy. At the upper and mid EAK rate range (440 and 220 nGy/s) the solid-state detector outperformed the reference IITV fluoroscopy system as measured by TCDD performance. At the lowest measured EAK rate (104 nGy/s), the solid-state detector produces slightly inferior TCDD performance compared with the reference system. Although not statistically significant at this EAK rate, the difference will increase as EAK is lowered further. Overall the TCDD results and early clinical experiences support the proposition that a current design of dynamic solid-state detector produces image quality competitive with that of modern IITV fluoroscopy systems. These findings encourage the development of compact and versatile universal x-ray imaging systems based upon solid-state detector technology to support R & F and vascular/interventional applications.

Biophysical Phenomena↗

Initial technical and clinical evaluation of a new universal image receptor system.

The aim of this study was to evaluate the physical performance of an experimental flat-panel digital X-ray detector plate (FDXD), and to assess its clinical potential in radiographic and fluoroscopic mode. The efficiency of the detector was assessed by calculating the low-frequency detective quantum efficiency (DQE(0)), and a measure of image quality was obtained using a threshold contrast detail detectability (TCDD) test object. A range of clinical examinations were also carried out, and the results reviewed by members of the radiology staff. The DQE(0) of the system was calculated to be almost 75%, compared with a value of approximately 20 % for modern computed radiography equipment, offering the potential for increased image quality or significant dose reduction. Measurements using the TCDD test object demonstrated a corresponding advantage for the FDXD in image quality and dose efficiency. Clinical studies are producing radiographic results which are at least the equal of the best currently available digital technology, and a limited number of examinations using fluoroscopic mode at 25 frames per second have been equally encouraging. Equipment using FDXD technology could potentially fulfill all the radiographic and fluoroscopic requirements of the digital department, with improved image quality and dose efficiency.

Equipment Design↗

Technical report: Initial experiences with an experimental solid-state universal digital X-ray image detector.

This paper presents a brief technical evaluation and first review of clinical experiences with an experimental direct digital X-ray image detector designed to support both dynamic and snap-shot imaging. Derivatives of this type of image detector can potentially fulfil the majority of the fluoroscopic and radiographic imaging requirements of clinical radiology departments, and initial results suggest that imaging systems using the new technology will provide a high quality dose-efficient solution to the search for a universal digital X-ray image detector.

Cecum↗

Physical imaging performance of a compact computed radiography acquisition device.

A comprehensive investigation of the physical imaging performance of a Philips AC3 computed radiography system using fifth-generation image plate technology has been undertaken. Measurements include characteristic response, modulation transfer function (MTF) and Wiener spectra (WS) for standard and high resolution image plates sampled at 10 pixels/mm. These results were used to calculate noise equivalent quanta (NEQ) and detective quantum efficiency (DQE) spectral descriptions of system performance. Luminescence noise and x-ray quantum noise components were separated. From an estimate of the luminescence noise power, the average system gain was calculated and results show a substantial improvement over earlier generations of computed radiography systems for standard image plates.

Calibration↗

A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography.

A selenium based digital x-ray system dedicated to chest radiography has been installed by the UK Department of Health's Medical Devices Agency at Leeds General Infirmary, UK, to undergo a comprehensive evaluation, including the physical image quality. The underlying characteristics which define the overall image quality of a system are the following: sensitometric response, modulation transfer function, and noise power spectrum. These have been measured objectively on preprocessed digital data acquired under relevant radiographic conditions. The image data is further processed prior to hard copy display. The displayed image quality may only be measured subjectively; threshold contrast detail detectability is such a measure which can be related to the objective measures of image quality. The objective imaging characteristics suggest that Thoravision has a significant advantage over conventional radiography imaging systems. However, subjective measures have demonstrated that the image processing can have a significant effect on the perceived image quality. Thoravision has the potential to deliver a significantly improved image quality to clinicians with no increase in radiation exposure to the patient, or image quality may be maintained with a reduction in radiation exposure. Digital image processing is central to the efficiency with which it achieves this.

Biophysical Phenomena↗

A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

The physical imaging performance of ST-V, ST-VA, and ST-VN computed radiography image plates, read with a Philips AC3 acquisition system, was investigated at 70 kVp with 0.5 mm of copper beam filtration for four different entrance air kerma values: 0.5, 2.6, 26, and 260 micro Gy. Measurements included characteristic response, presampling-modulation transfer function, and Wiener spectrum analysis for (18 x 24) cm2 image plates, sampled at 10 pixels/mm. These results were used to calculate DQE spectral descriptions of system performance. ST-VN image plates exhibited a slightly superior DQE performance for the two lower entrance air kerma values investigated.

Quantum Theory↗

Reporting requirements for skeletal digital radiography: comparison of soft-copy and hard-copy presentation.

PURPOSE: To assess diagnostic performance and reader preference when reporting results from digital hard-copy and two soft-copy formats of skeletal digital radiography. MATERIALS AND METHODS: The data comprised hand radiographs of patients undergoing renal dialysis. Normal hand radiographs obtained in trauma patients were assessed as control images. One hundred fifteen images acquired with a photostimulable-phosphor computed radiography system were analyzed. Image selection and initial assessment were by consensus of two experienced radiologists, who graded the radiographic changes of hyperparathyroidism with the Ritz scoring system. The images were then presented to four readers in three formats: hard-copy output and soft-copy presentations at 2K2 and 1K2 resolutions. These readers scored pathologic change and image preference. The results were analyzed with the receiver operating characteristic technique. RESULTS: There was a significant improvement in diagnostic performance for both soft-copy formats relative to the hard-copy format (P < .001). No significant difference in diagnostic performance was found between the two soft-copy formats. There was a significant preference for both soft-copy formats relative to the hard-copy format (P < .01), with the 2K2 soft-copy images preferred to the 1K2 images (P < .01). CONCLUSION: Soft-copy reporting can provide superior diagnostic performance even for images viewed at a modest (1K2) resolution. The lack of difference between the two soft-copy formats has important economic implications with respect to departmental hardware requirements.

Bone and Bones↗

Direct digital mammography image acquisition.

Mammography is a branch of radiology which could benefit greatly from the assimilation of digital imaging technologies. Computerized enhancement techniques could be used to ensure optimum presentation of all clinical images. Beyond this it will facilitate powerful new clinical resources such as computer-assisted diagnosis, tele-mammography, plus digital image management and archiving. An essential precursor to all these advances is the availability of appropriate direct digital mammography (DDM) image-acquisition system(s) to capture high-quality breast X-ray image data at the outset. The only practical DDM image-acquisition system currently available is (photo-stimulable phosphor) computed radiography. Modern computed mammography (CM) uses similar radiation doses to the patient and produces equivalent, albeit different, image quality to screen-film mammography. Computed mammography offers superior rendition of the skin edge and sub-cutaneous tissue and dense parenchyma, while ensuring equivalent micro-calcification detectability. Meanwhile, a variety of new technical approaches to DDM are under active investigation and/or development which promise to supercede film-based mammography. These new (second generation) DDM technologies promise the radiologist superior image quality combined with significant dose savings compared with contemporary imaging systems. In this review we describe and compare the physical and clinical characteristics of CM and the various emerging DDM image-acquisition technologies.

Female↗

Visibility of microcalcifications in computed and screen-film mammography.

Due to the clinically and technically demanding nature of breast x-ray imaging, mammography still remains one of the few essentially film-based radiological imaging techniques in modern medical imaging. There are a range of possible benefits available if a practical and economical direct digital imaging technique can be introduced to routine clinical practice. There has been much debate regarding the minimum specification required for direct digital acquisition. One such direct digital system available is computed radiography (CR), which has a modest specification when compared with modern screen-film mammography (SFM) systems. This paper details two psychophysical studies in which the detection of simulated microcalcifications with CR has been directly compared to that with SFM. The first study found that under scatter-free conditions the minimum detectable size of microcalcification was approximately 130 microns for both SFM and CR. The second study found that SFM had a 4.6% higher probability of observers being able to correctly identify the shape of 350 microns diameter test details; there was no significant difference for-either larger or smaller test details. From the results of these studies it has been demonstrated that the modest specification of CR, in terms of limiting resolution, does not translate into a dramatic difference in the perception of details at the limit of detectability. When judging the imaging performance of a system it is more important to compare the signal-to-noise ratio transfer spectrum characteristics, rather than simply the modulation transfer function.

Breast Diseases↗

A comparison of the threshold detail detectability of a screen-film combination and computed radiology under conditions relevant to high-kVp chest radiography.

There is conflicting evidence regarding the viability of photostimulable phosphor computed radiology (CR) when used with high x-ray beam energies. In this study a standard screen-film combination was compared with CR using identical exposure conditions, which simulated those of a high-energy chest examination. The comparison was made using a psychophysical technique in which the threshold contrast detail detectability is assessed by human observers. Threshold contrast determination is an efficient way with which to assess the overall image quality. The CR images were processed and displayed using two independent image processing algorithms and hard-copy formats. The results showed, at the 5% level of statistical significance, that there was no difference in the overall image quality between any of the modalities being compared. It may be concluded therefore that CR is a potentially viable option for use in high-energy radiography of the chest.

Biophysical Phenomena↗

Update on the recommended viewing protocol for FAXIL threshold contrast detail detectability test objects used in television fluoroscopy.

The significance of varying the viewing conditions that may affect the perceived threshold contrast of X-ray television fluoroscopy systems has been investigated. Factors investigated include the ambient room lighting and the viewing distance. The purpose of this study is to find the optimum viewing protocol with which to measure the threshold detection index. This is a particular problem when trying to compare the image quality of television fluoroscopy systems in different input field sizes. The results show that the viewing distance makes a significant difference to the perceived threshold contrast, whereas the ambient light conditions make no significant difference. Experienced observers were found to be capable of finding the optimum viewing distance for detecting details of each size, in effect using a flexible viewing distance. This allows the results from different field sizes to be normalized to account for both the magnification and the entrance air kerma rate differences, which in turn allow for a direct comparison of performance in different field sizes.

Clinical Protocols↗

Improved image quality utilizing dual plate computed radiography.

A method of improving image quality in computed radiography (CR) using dual plate exposure has been developed. Two CR image plates are used to increase the fraction of X-ray quanta absorbed from the beam. Spatial registration and combination of images from the two plates leads to an image with improved signal-to-noise ratio characteristics. A cross correlation technique is used to register spatially the images from the front and rear plates. The modulation transfer function and noise power spectrum were measured for the single plate and combined dual plate images. Results indicate a potential increase of approximately 60% in the detective quantum efficiency (DQE) of the dual plate combined image compared with the single plate image. The improvement of DQE at high spatial frequencies is dependent on the accuracy of the registration of the two images. The actual improvement in imaging performance was measured using a contrast detail test piece. A computerized method was used to measure the imaged detail signal-to-noise ratio of the details of different dimension. Results indicate an improvement of 21% in the signal-to-noise ratio of the details imaged with the dual plate arrangement compared with the single plate. This indicates that this technique can result in a significant increase in image quality for the same exposure level. Alternatively this technique could allow reduction in exposure while maintaining the same image quality achievable with the single plate system.

Humans↗

Technical note: dual compression mammography using computed radiography.

On mammography most malignant growths may be seen as a tethered mass or architectural distortion. Benign lesions such as cysts and fibroadenomas have no focal tethering and are usually well circumscribed. Computed radiography (CR) is a direct digital system which may be used for mammography. One of the main advantages of CR is its wide exposure latitude allowing images to be acquired at lower exposures than required for film-screen systems. A technique was developed, utilizing the exposure latitude of CR, to acquire two mammograms of the same breast at two slightly different compressions, but using approximately the same exposure as a single film-screen mammogram. These images were then "animated" on a computer allowing the fibrous septa movement to be visualized. The movement of the fibrous septa in the presence of an abnormality was used to help confirm whether a lesion was benign or malignant. This technique may have clinical application in classifying architectural distortions and masses which are ultrasonically benign but later found to be malignant. Microcalcifications cannot be used as a diagnostic indicator with this technique because of the increased noise associated with the lower exposures. The increased noise did not affect the visualization of masses.

Breast Neoplasms↗