Search PubMed⌕ Search

Biomedical subjects

A Pollak

Publications and source records attributed to A Pollak.

At least 37 records · Page 2Linked to original sources

Treatment of toxoplasmosis in pregnancy: concentrations of spiramycin and neospiramycin in maternal serum and amniotic fluid.

Toxoplasma infection during pregnancy is widely treated with oral spiramycin to reduce the risk of congenital toxoplasmosis in the infant. Failures of therapy have been observed, however. In this study, a sensitive high-performance liquid chromatography technique was used to measure concentrations of spiramycin and neospiramycin, one of the major metabolites of spiramycin, in maternal serum and amniotic fluid. Samples were obtained from 18 women who underwent amniocentesis for polymerase chain reaction (PCR) diagnosis of fetal infection 5-109 days following the prescription of spiramycin therapy (3 g/day). Concentrations of spiramycin and neospiramycin in both serum and amniotic fluid were highly variable, ranging from nondetectable values to 1 microg/ml. None of the concentrations measured were within the range reported to inhibit growth of the parasite in vitro. Consistent with previous reports, part of the observed variability in maternal and fetal drug concentrations could be explained by individual differences in several pharmacokinetic parameters: intestinal absorption, tissue distribution, cellular uptake, metabolism, transfer across the placenta, drug accumulation in fetal tissue, and maternal and fetal drug elimination. The heterogeneity of the data could also be related to differences in patient compliance with the medication prescribed. By addressing factors that could impair adequate treatment of toxoplasmosis during pregnancy, the data presented call for a larger-scale controlled study to determine individual and diurnal variations in maternal drug levels, patient compliance, and outcomes of the offspring. The activity of neospiramycin against Toxoplasma gondii should be assessed.

Adolescent↗

Left atrial appendage emptying velocity does not predict postoperative atrial fibrillation in patients undergoing cardiopulmonary bypass.

BACKGROUND: Atrial fibrillation is a common complication of cardio-pulmonary bypass and improved pre-operative risk assessment could help guide prophylactic therapy. This study examined whether reduced left atrial appendage flow velocities measured by transoesophageal echocardiography pre-operatively in patients in sinus rhythm predicted development of postoperative atrial fibrillation. METHODS AND RESULTS: All patients who underwent transoesophageal echocardiography for clinical indications with measurements of left atrial appendage velocities within twelve months prior to cardio-pulmonary bypass were retrospectively identified. Postoperative records were reviewed and the patients divided into two groups based on the presence or absence of clinically significant atrial fibrillation during hospitalization following cardio-pulmonary bypass. Thirty-six patients (mean age 61.1 +/- 14.8 years, 18M/18F) were included in the study. The overall incidence of atrial fibrillation in the cohort was 17/36 patients (47%). Mean left atrial appendage emptying velocity was 50.8 +/- 23.3 cm/s2 (range 26-119) in the patients with sinus rhythm only and 41.5 +/- 16.7 cm/s2 (range 16-76), in the patients with postoperative atrial fibrillation (P=ns). CONCLUSIONS: In our patient population there was no significant difference in left atrial appendage emptying velocity measured by transoesophageal echocardiography in patients with and without postoperative atrial fibrillation. Pre-operative measurement of left atrial appendage emptying velocity cannot be relied upon to risk stratify patients prior to cardio-pulmonary bypass.

Atrial Appendage↗

Evaluation of the Cerebral Function Monitor as a tool for neurophysiological surveillance in neonatal intensive care patients.

BACKGROUND: Cerebral function in critically ill infants is difficult to assess and would certainly require continuous monitoring. Therefore, this study was performed to evaluate the Cerebral Function Monitor (CFM) as a tool for continuous neurophysiological surveillance in the Neonatal Intensive Care Unit (NICU). PATIENTS: A total of 40 neurological risk neonates were included in the study. They were classified on the basis of their primary diagnoses as infants with clinically manifest seizures, suspected seizure activity, intracranial hemorrhage (ICH) and hypoxic-ischemic encephalopathy (HIE). A group of 20 neurologically normal (preterm and full-term) infants served as controls. RESULTS AND CONCLUSION: All patients with seizures showed pathologic patterns in both the CFM and the conventional EEG tracings. The patients with ICH showed depressed amplitudes, an increase in discontinuous activity, and a high incidence of seizure activity. The patients with HIE were characterized by depressed activities correlating with the severity of the pathology. Our results indicate that the CFM is a very helpful tool for neurophysiological surveillance in high-risk neonates.

Brain Damage, Chronic↗

Position dependent changes of cerebral blood flow velocities in premature infants.

UNLABELLED: The supine or prone positioning of infants has been a cause of much controversy. Recently it has been postulated that the position dependent hypoperfusion of the brainstem represents a possible cause of sudden infant death. To demonstrate position dependency and maturational changes of cerebral perfusion in premature newborn infants we investigated cerebral blood flow velocities (CBFV) in the main supratentorial and brainstem cerebral arteries. Measurements of CBFV were done with transfontanellar colour-coded Doppler sonography in the internal carotid artery (ICA), basilar artery (BA), and vertebral artery (VA) in the prone (head centered-baseline) and supine positions (maximal rotation to both sides) in 23 premature infants aged between 3-5 days of life. We performed follow-up measurements in 17 infants 7-10 days later and in 16 infants at the corrected age of 1 month. There was no difference in mean CBFVs between the prone and supine position at the first investigation. At the third investigation, CBFVs were significantly higher in the supine compared to the prone position. The CBFVs of the ICA were higher than in the BA and VA. This difference was not influenced by the body position but increased with post-natal age more in the VA (159%) than in the BA (129%) and ICA (128%). Position dependency was not seen in the ICA perfusion. In the prone position, five infants showed an incomplete steal effect in the contralateral VA. There was no significant side difference in the CBFVs of the ICA and VA, but in the resistance indices in the VA (left > right). CONCLUSION: in premature newborns, position dependent changes of cerebral blood flow velocity develop with maturation and are most pronounced in the vertebrobasilar system. These changes are possibly due to compression of the vertebral artery by neck movement and suggest an individual risk of brainstem perfusion deficits that may be aggravated with age and head rotation in a prone position.

Analysis of Variance↗

Ecological comparison of the risks of mother-to-child transmission and clinical manifestations of congenital toxoplasmosis according to prenatal treatment protocol.

We compared the relative risks of mother-to-child transmission of Toxoplasma gondii and clinical manifestations due to congenital toxoplasmosis associated with intensive prenatal treatment in Lyon and Austria, short term treatment in 51% of Dutch women, and no treatment in Danish women. For each cohort, relative risks were standardized for gestation at seroconversion. In total, 856 mother-child pairs were studied: 549 in Lyon, 133 in Austria, 123 in Denmark and 51 in The Netherlands. The relative risk for mother-to-child transmission compared to Lyon was 1.24 (95% CI: 0.88, 1.59) in Austria; 0.59 (0.41, 0.81) in Denmark; and 0.65 (0.37, 1.01) in The Netherlands. Relative risks for clinical manifestations compared with Lyon (adjusted for follow-up to age 3 years) were: Austria 0.19 (0.04, 0.51); Denmark 0.60 (0.13, 1.08); and The Netherlands 1.46 (0.51, 2.72). There was no clear evidence that the risk of transmission or of clinical manifestations was lowest in centres with the most intensive prenatal treatment.

Anti-Bacterial Agents↗

A pulsatile pneumatically driven neonatal extracorporeal membrane oxygenation system using neck vessel cannulas tested with neonatal mock circulation.

In posthypoxic circulatory failure, pulsatility of flow generated by mechanical support devices significantly influences outcome. Pneumatically driven assist devices can create highly pulsatile flow, but need large graft cannulas implanted by thoracotomy in children and neonates. Emergency application is therefore hindered. We conducted an in vitro study using neonatal mock circulation (NMC) to test whether an extracorporeal membrane oxygenation (ECMO) system driven by a commercially available pneumatic assist device also can be operated through commonly used neonatal neck vessel cannulas. Using the pneumatically operated Medos ventricular assist device (VAD) 10 ml ventricle along with the Jostra M8/HEC40 oxygenator/heat exchanger, a neonatal ECMO system was assembled and connected to the NMC by means of commercially available neonatal neck vessel cannulas. Effective ECMO flow, combined circulation flow, and circulation pressures were measured during various working settings (ventricle driving pressures [systolic/diastolic (mbar)]: low: +100/-25, moderate: +200/-50, high: +300/-99) and loading conditions (device working against 0, 50, and 100% native circulation flow). Additionally, maximum possible ECMO flow through various sizes of neonatal ECMO cannulas and resulting pressure gradients were assessed. High pressure settings were necessary to achieve 100 ml/kg/min pulsatile circulation flow in case of zero native circulation. With residual 30% native circulation flow, 100 ml/kg/min pulsatile circulation flow could be established by moderate pressure settings. Low preload or high systemic vascular resistance reduced ECMO flow markedly. We concluded that in the described setting a pneumatically driven neonatal ECMO system could be operated even through commonly used neonatal neck vessel cannulas. It was necessary to accept partial emptying of the artificial ventricle and tapering of driving pressures with increasing native circulation.

Blood Pressure↗

Neonatal and pediatric extracorporeal membrane oxygenation using nonocclusive blood pumps: the Vienna experience.

Neonatal and pediatric extracorporeal membrane oxygenation (ECMO) is carried out commonly using occlusive blood pumps. Centrifugal pumps provide simple and safe technology for transportation on ECMO. The assistence respiratoire extra corporelle (AREC) system enables single needle venovenous ECMO for infants. We report on our experience with neonatal and pediatric ECMO treatments using nonocclusive blood pumps. One-hundred forty-six ECMO treatments were performed for cardiac, neonatal, and pediatric indications in 54, 19, and 27% of cases. Centrifugal pumps were used in 99, and the AREC system in 42 cases. Hospital mortality was estimated retrospectively and influence of type of pump, type of ECMO belonging to indication group, and lactate at ECMO installation were estimated. Irreversible organ failure leading to ECMO termination was investigated within groups of indications. Survival (recent 50 ECMO treatments) was 80, 70, 43, and 30% after meconium aspiration syndrome, acute respiratory distress syndrome, cardiac surgery, and prolonged resuscitation. Lactate exceeding 100 mg/dl at ECMO installation predicted significantly worse outcome. Cerebral damage was the main reason for ECMO termination in all but persistent circulatory failure in the cardiac group. Myocardial recovery resulted in all except 2 cardiac cases. Nonocclusive blood pumps can be used safely in neonatal and pediatric ECMO. Early installation may improve outcome markedly. In cardiac cases results of surgery should be thoroughly investigated on the table before ECMO installation to prevent hopeless ECMO treatments.

Child↗

Effect of intravenous iron supplementation on erythropoiesis in erythropoietin-treated premature infants.

OBJECTIVE: To test the efficacy and safety of combining intravenous iron in amounts approximating the in utero iron accretion rate and the postnatal iron loss with erythropoietin (EPO) in very low birth weight (VLBW) infants. METHODS: A prospective, controlled, randomized, unmasked trial lasting 21 days was performed in 29 clinically stable VLBW infants <31 weeks' gestation and <1300 g birth weight not treated with red blood cell transfusions during the study period. Mean (+/- standard error of the mean) age at study entry was 23 +/- 2.9 days. After a 3-day run-in baseline period in which all participants received oral supplements of 9 mg/kg/day of iron polymaltose complex (IPC), participants were randomized to receive 18 days of treatment with: 1) oral IPC alone (oral iron group); 2) 300 U of recombinant human EPO (r-HuEPO) kg/day and daily oral IPC (EPO + oral iron group); 3) 2 mg/kg/day of intravenous iron sucrose, r-HuEPO, and oral iron (intravenous iron + EPO group). To assess efficacy of the 3 treatments, serial blood samples were analyzed for hemoglobin (Hb), hematocrit (Hct), reticulocyte count, red blood cell indices and plasma levels of transferrin, transferrin receptor (TfR), ferritin, and iron. Oxidant injury was assessed before and after treatment by plasma and urine levels of malondialdehyde (MDA) and o-tyrosine. RESULTS: At the end of treatment, Hb, Hct, reticulocyte count, and plasma TfR were markedly higher in both of the EPO-treated groups, compared with the oral iron group. At study exit a trend toward increasing Hb and Hct levels and significantly higher reticulocyte counts were observed in the intravenous iron + EPO group, compared with the EPO + oral iron group. During treatment, plasma ferritin levels increased significantly in the intravenous iron + EPO group and decreased significantly in the other 2 groups. By the end of treatment, ferritin levels were significantly higher in the intravenous iron + EPO group compared with the other 2 groups. Although plasma and urine MDA or o-tyrosine did not differ among the 3 groups, plasma MDA was significantly greater in the subgroup of intravenous iron + EPO participants sampled at the end of the 2-hour parenteral iron infusion, compared with values observed immediately before and after parenteral iron-dosing. CONCLUSIONS: In stable VLBW infants receiving EPO treatment, parenteral supplementation with 2 mg/kg/day of iron sucrose results in a small, but significant, augmentation of erythropoiesis beyond that of r-HuEPO and enteral iron alone. However, to reduce the potential adverse effects of parenteral iron/kg/day on increasing plasma ferritin levels and on causing oxidative injury, we suggest that the parenteral iron dose used should be reduced and/or the time of infusion extended to maintain a serum iron concentration below the total iron-binding capacity.

Administration, Oral↗

SIDS related anxiety--a risk factor analysis.

BACKGROUND: The growing public interest in the Sudden Infant Death Syndrome (SIDS) has led to a new psychological problem--SIDS related anxiety (SRA). General public awareness, unfavourable experience in the past, present problems with the infant or insufficient support from the family may lead or contribute to SRA. OBJECTIVE: The study was conducted to explore which of these factors contribute most to the development of SRA. PATIENTS AND METHODS: Families visiting our outpatient clinic during 18 months were interviewed by means of a structured questionnaire. We assessed demographic data, obstetric history, experience of child loss, pregnancy and delivery complications, infant morbidity, family-child interaction, family support and the relation of each of these single factors to SRA. RESULTS: Of 169 families, 58% (98/169) admitted to suffer from SRA and 21% (32/156) from severe SRA. We found a strong and significant relationship between previous experience of child loss and SRA (OR: 2.95, 95% CI: 1.43-6.09, P < 0.005) and between pregnancy complications and SRA (OR: 2.19, 95% CI: 1.18-4.08, P < 0.05). There were no significant relationships between SRA and either delivery complications, child morbidity, impaired family-child interaction or insufficient support from the family. CONCLUSIONS: SRA occurs in an unexpectedly large proportion of families visiting a SIDS counseling clinic. SRA must be taken seriously, and psychological or psychotherapeutic help should be offered. Prevention of SRA should include psychological care for families who experience loss of children or high-risk pregnancies.

Adult↗

[Viennese SIDS prevention campaign-- a quality management project].

At the 4th Austrian SIDS Consensus Meeting (1998), consultation was the focus of attention. Secure sleep, the Vienna SIDS prevention campaign, is an information campaign in cooperation with the children's hospitals of Vienna with the aim of reducing the incidence of SIDS in and around Vienna. The campaign was intended to spread awareness concerning care measures to reduce SIDS as well as to reduce SIDS related anxiety (SRA) among anxious parents. The Vienna SIDS prevention campaign is a quality management project, the core of which is consultation. Demands upon the structural quality of a SIDS consultation office include the expertise, communication skills and psychological competence of the consulting team. This can be achieved through interdisciplinary continuing education, international networking and training in communication skills. Priority is given to supporting care for the client by an interdisciplinary team headed by a case manager with the required communication skills. The qualitative outcome is defined by a primary objective medical goal (reduction of SIDS mortality) and a secondary subjective psychological goal (reduction of SRA). It also includes raising effectiveness and efficiency through optimal consultation and, finally, reducing costs by saving expenditure for monitors. The quality of SIDS consultation can be measured by evaluating satisfaction in patients as well as among co-workers.

Austria↗

Effects of endotracheal suctioning in high-frequency oscillatory and conventionally ventilated low birth weight neonates on cerebral hemodynamics observed by near infrared spectroscopy (NIRS).

Adverse changes in cerebral hemodynamics during endotracheal suctioning have been reported in conventionally ventilated newborns, whereas observations on the effect of endotracheal suctioning during high-frequency ventilation have not been reported to date. The present study was designed to investigate the effect of endotracheal suctioning on cerebral hemodynamics in high-frequency and conventionally ventilated infants. Changes in cerebral concentration of oxygenated (cO(2)Hb) and deoxygenated hemoglobin (cHHb) and oxidized cytochrome aa3 (cCyt.aa3) were measured by noninvasive near-infrared spectroscopy. In an open prospective study, 26 suctioning periods in 9 high-frequency and in 6 conventionally ventilated newborn infants were investigated. Heart rate, arterial oxygen saturation (SaO(2)), mean blood pressure (MABP), and transcutaneous carbon dioxide tension (TcpCO(2)) were monitored continuously. In both groups, a marked decrease in heart rate, SaO(2) and in cO(2)Hb, an increase in cHHb, and a variable pattern in the concentration of total hemoglobin were noted during endotracheal suctioning. During suctioning, no statistically significant differences between the two methods of mechanical ventilation could be observed. We conclude that the mode of ventilation had no significant effect on changes in cerebral hemodynamics during endotracheal suctioning.

Brain↗

[Recent advances in neonatology--new tasks for the radiologist].

Modern neonatology comprises care for a growing number of infants with congenital abnormalities and an increasing number of premature born infants. The survival rates of premature infants have increased dramatically during the past decade. This increase in survival rates can be attributed to improved prenatal and obstetric management and to advances in neonatal intensive care medicine. RADIOLOGICAL SUPPORT: Neonatology has become a pediatric subspecialty of its own resulting in the demand for an equally specialised radiological support. Therefore the availability of a children's radiologist for radiological and sonographic examinations is mandatory (24 hours a day) for optimal patient care on a neonatal intensive care unit. A good cooperation between radiologist and neonatologist in neonatal intensive care medicine is therefore warranted.

Austria↗

Long-term experience with subcutaneously tunneled external ventricular drainage in preterm infants.

We previously reported on a series of 27 newborn infants treated for posthemorrhagic hydrocephalus with external ventricular drainage during 1984 to 1989. In the present study we continued to evaluate this technique during the subsequent 8 years (37 patients; mean birthweight 1251+/-478 g; mean gestational age 29+/-2.9 weeks; 51 drains), and we now report on the long-term experience with this method, complications, and neurodevelopmental outcome of the survivors. The mean age at drain insertion was 21 days, and the mean duration of drainage 23 days. Eight infants died of causes unrelated to external ventricular drainage. Eleven of the survivors did not require a permanent shunt. Two patients experienced ventriculitis, resulting in an infection rate of 5.4% per patient and 3.9% per drain. The neurodevelopmental outcome was mainly dependent on the extent of the pre-existing parenchymal injury. We conclude that external ventricular drainage is a safe and effective technique for the management of preterm infants with posthemorrhagic hydrocephalus.

Brain Damage, Chronic↗

Association of fetal and maternal carboxyhemoglobin levels in normal and Rh-alloimmune pregnancies.

OBJECTIVE: To compare paired antepartum fetal/maternal COHb ratios in whole blood from control and alloimmunized pregnancies and to examine the relationships between fetal and maternal COHb. METHODS: COHb levels were measured in paired fetal and maternal blood samples obtained at cordocentesis in 47 control and 16 Rh-alloimmunized pregnancies. COHb was determined by gas chromatography. Results were analyzed by t-test, regression and analysis of covariance. RESULTS: Although fetal/maternal COHb ratios for control and alloimmunized pregnancies were not statistically significantly different, i.e. 1. 11+/-0.04 and 1.26+/-0.09, respectively (P=0.09), fetal COHb levels were higher in Rh-alloimmunized fetuses (P=0.0002). Fetal COHb levels were also higher than paired maternal levels among the alloimmunized group (P=0.011), but not among the control group (1. 04+/-0.04, P=ns). In univariate regression analysis, fetal and maternal COHb levels were significantly correlated with one another in both control (r=0.52, P=0.0002) and alloimmunized pregnancy groups (r=0.52, P=0.05). Comparison of the slopes of the fetal versus maternal COHb plots for the two groups showed a significant difference (P=0.02), with the alloimmunized group having the steeper slope. CONCLUSION: Differences in the antepartum fetal-maternal COHb relationships in control and alloimmunized groups likely reflect increased endogenous CO production among alloimmunized fetuses as a result of pathologic hemolysis.

Adult↗

A solid-phase technique for preparation of no-carrier-added technetium-99m radiopharmaceuticals: application to the streptavidin/biotin system.

A high effective specific activity (HESA) formulation of a biotin-containing (99m)Tc ligand [RP488: dimethyl-Gly-Ser-Cys(Acm)-Lys(Biotin)-Gly] conveniently prepared from solid phase was compared to a typical low effective specific activity (LESA) solution formulation to demonstrate improved targeting to streptavidin in an in vitro assay and in an in vivo rat model. RP488 was coupled to a maleimide-functionalized polyethylene glycol resin via a thiol ether linkage and labeled with (99m)Tc-gluconate at room temperature, followed by elution of the HESA (99m)Tc-RP488 in saline (minimum specific activity approximately 1000 TBq/mmol by amino acid analysis). Both HESA and LESA (99m)Tc-RP488 labeled at > 90% purity. In vitro, HESA (99m)Tc-RP488 incubated with streptavidin-agarose was bound quantitatively, but there was competition from addition of increasing amounts of cold RP488. In rats, radiotracer uptake was evident at the site of implantation of streptavidin-agarose beads for the HESA dose, less uptake of low effective specific activity (LESA) material, and no appreciable uptake in the control rats of the LESA or HESA dose. The target-to-background ratio for HESA (99m)Tc-RP488 was 5.4 times that of the control. The solid-phase technology offers a convenient way to prepare high specific activity receptor-targeting (99m)Tc radiopharmaceuticals.

Animals↗