Search PubMed⌕ Search

Biomedical subjects

A Pizzoferrato

Publications and source records attributed to A Pizzoferrato.

At least 73 records · Page 4Linked to original sources

Disposable contact lenses and bacterial adhesion. In vitro comparison between ionic/high-water-content and non-ionic/low-water-content lenses.

An in vitro quantitative study of the adhesion of a Staphylococcus aureus strain to two types of disposable contact lenses has been carried out. The first type was an ionic/high-water-content (I-HWC) lens (42% Etafilcon A, 58% water) and the second was a non-ionic/low-water-content (Nl-LWC) lens (61.4% poly(2-hydroxyethyl methacrylate), 38.6% water). Adhesion to the two lens types was evaluated both in basic conditions and after treatment with lysozyme. The results showed that I-HWC lenses are more prone to Staphylococcus aureus adhesion than NI-LWC lenses, both untreated (+15.4%) and treated with lysozyme (+20.5%). Lysozyme increased bacterial adhesion by 30.5% on the lenses with lower water content, and by 36.3% on those with higher water content.

Bacterial Adhesion↗

Endodontic cements induce alterations in the cell cycle of in vitro cultured osteoblasts.

The effects of endodontic cements on the cell cycle of MG63 osteoblasts cultured in vitro have been examined. Three groups of compounds were tested. Group I encompassed zinc oxide- and eugenol-based cements (Tubliseal, Argoseal, N2), group II consisted of cements with a phenol group other than eugenol (AH26, Forfenan, Methode R/R), and group III included CaOH-based cements (Biocalex, Endocalex). The cell cycle of MG63 cells was analyzed by flow cytometry; the DNA content was evaluated by means of the propidium iodide uptake method, whereas the proportion of cells in the S phase was defined by the incorporation of bromodeoxyuridine later revealed by a specific antibody. The results showed that some root canal sealers could hamper the periapex healing processes by inhibiting the cell proliferation through a selective action on different phases of the cell cycle.

Analysis of Variance↗

[Evaluation of the biocompatibility of medical devices based on European standards].

Several issues concerning the biocompatibility) testing of medical devices as stated in European directive 90/385 and 93/42 are discussed. The authors describe the fundamental characteristics that biomaterials should have to be employed in the human body, the assays useful for testing different aspects of biocompatibility and the harmonized regulations already available or under development. The testing protocol applied by the a. in their Lab covering many issues of biocompatibility is presented: a body of experience was gained over the years and it has been revised under the new regulatory items. In conclusion, the biocompatibility of devices must be assessed following the European harmonized standards, the available. Where proper standards are still lacking, feasible testing methods, even if not officially adopted yet, have to be used.

Biocompatible Materials↗

[European regulations concerning medical devices].

The employment in clinical practice and prosthetic surgery of a number of medical devices implies a great responsibility to the operators so as to make the knowledge of existing regulations mandatory. The authors illustrate the problems concerning the free circulation of medical devices within the European market. They describe the new strategy of EEC which led to the definition of the directives which apply to all medical devices and of the harmonized standards for inspecting their biological effects. The appointment of certification bodies and the accreditation of Testing Laboratories are described. Finally, particular attention is given to product certification, which is compulsory for the pre-market approval of medical devices.

Accreditation↗

Mutagenic potential of root canal sealers: evaluation through Ames testing.

The mutagenic potential of 12 commercially available dental cements and of two 'pure substances' (zinc oxide and eugenol) used in root canal filling were examined. The cements were prepared according to the manufacturers' indications and set for defined times. Ames tests were performed in their extracts by using Salmonella typhimurium strains TA 98 and TA 100. The results showed that most cements present strong bactericidal activity that disappears or decreases remarkably in time. One of the tested cements showed mutagenicity with both Salmonella strains. Two cements yielded doubtful results. The remaining cements and the two 'pure substances' showed no mutagenic potential. The authors conclude that it is convenient to examine endodontic cements with the Ames test and to eliminate those that present mutagenicity in time.

Animals↗

Cytotoxicity testing of cyanoacrylates using direct contact assay on cell cultures.

The use of a tissue adhesive for surgical procedures has prompted a large number of clinical and experimental studies. Alkyl-2-cyanoacrylate esters constitute a family of adhesives with good mechanical properties but their biological compatibility has to be assessed. In this study the cytotoxicity of three commercially available cyanoacrylates and one of unknown composition has been determined. The first part of the study deals with direct contact testing procedures using L 929 cells challenged with drops of adhesives: cell morphology, cell growth and bacterial growth inhibition were assayed. Testing methods included cell viability assay using vital dyes, cell growth measurement using crystal violet staining uptake and bacterial growth assay using S. aureus growth inhibition. All the cyanoacrylate adhesives tested were found to be cytotoxic and to inhibit cell proliferation: differences between the cyanoacrylates were found.

Adhesives↗

Toxicity of cyanoacrylates in vitro using extract dilution assay on cell cultures.

Comparative cytotoxicity testing of four cyanoacrylate adhesives suggested for orthopaedic applications was performed. These substances were placed in complete culture medium with serum and the resulting extraction fluids were tested on L 929 cells and human lymphocytes. Testing procedures include cell morphology assessment using light microscopy and vital dyes, cell counting using a computer-assisted image analysis system, cell growth measurement using total protein content assay and cell viability assessment using the MTT method. Quantitation of the toxicity of the degradation products released by cyanoacrylates in the extracts was achieved and differences in the cytopathic effect related to the chemical composition of the cyanoacrylates were found. A toxicity rating of the assayed cyanoacrylate adhesives was obtained as follows (in order of increasing toxicity): BCA < xCA < ECAg < ECAl.

Adhesives↗

Cell culture methods for testing biocompatibility.

Cell culture systems may be of value in testing the biocompatibility of prosthetic materials before they are introduced into clinical use. In recent years, in vitro methods for assaying biomaterials have gained in importance owing to the growing concern over the use of animals for biomaterials testing. Significant effort is therefore being focused toward developing predictive and quantitative, but also simple and reliable, methods of testing using cultured cells. At present, a number of methods for measuring both the cytotoxicity and the specific cytocompatibility of different materials are available. The usefulness of these systems is no longer confined to screening new materials; they can be used to study the mechanisms of action of various materials during tissue/material interaction. This paper reviews the published literature on the use of cell culture models in evaluating biocompatibility and reports on the personal experience of the authors, who have been using cell culture systems for many years and for different purposes.

Biocompatible Materials↗

Bone demineralization induced by cementless alumina-coated femoral stems.

The biologic compatibility of ceramic materials has been widely demonstrated, and alumina (Al2O3) has been used extensively in clinical applications for nearly 20 years. The authors examined the behavior of bone tissue adjacent to the alumina coating in eight cementless hip prosthetic stems that appeared radiologically stable and were explanted because of pain. Histologic evaluation demonstrated the presence of a consistent layer of decalcified bone tissue in continuity with and parallel to the prosthetic interface. Based on laboratory findings, the authors attribute this demineralization phenomenon to a high local concentration of aluminum ions with metabolic bone disease, which is histologically comparable to the osteomalacic osteodystrophy described in dialysis patients. These findings must be carefully considered given the potential long-term implications for alumina-coated implants.

Aged↗

In vitro adhesion of Staphylococcus epidermidis on heparin-surface-modified intraocular lenses.

This quantitative study assessed the in vitro adhesion of Staphylococcus epidermidis on two types of intraocular lenses: conventional poly(methyl methacrylate) (PMMA) and heparin-surface-modified PMMA. Level adhesion was measured by microbiological turbidimetry. We also measured modifications in the bacterium's structural fatty acids after adhesion using gas chromatography.

Bacterial Adhesion↗

The association of ageing with calcium active hormone status in men.

We measured calcium regulating hormones and bone mineral density (BMD) in 66 men (aged 24-88 years). Vitamin D (1,25(OH)2D) does not vary with age, parathyroid hormone (PTH) increases after the age of 65 (p < 0.01) together with a parallel increase in urinary (r = 0.46, p < 0.05) and nephrogenic cAMP (r = 0.63, p < 0.01), while BMD decreases with age (r = -0.52, p < 0.01). The finding of age-associated decreases in bone mass even in the presence of constant serum levels of 1,25(OH)2D within the normal range suggests that there is an onset of tissue resistance to vitamin D in the aetiopathogenesis of osteopenia in elderly men.

Adult↗

[The capability of silicone prostheses to promote postoperative infections. An in-vitro study].

The authors have quantitatively evaluated and compared in vitro the Staphylococcus aureus and Staphylococcus epidermidis strain adhesiveness on various types of silicone used in surgery. The results show that there are some adhesiveness differences between the two assayed strains (S. epidermidis adhesiveness > S. aureus adhesiveness) and among silicone types (adhesiveness on soft silicones > adhesiveness on hard silicones). However all silicones are suitable substrata for in vitro bacterial adhesion.

Bacterial Adhesion↗

Calcium regulating hormones in healthy elderly men: relation to intestinal calcium absorption.

Aged male subjects often have osteoporosis and it has been suggested that the cause is an age-related lack of vitamin D. We evaluated the calcium regulating endocrine mechanism in healthy aged males in order to verify this hypothesis. We studied serum levels of PTH and 1,25(OH)2D in relation to intestinal calcium absorption, radial bone mass density (BMD) and osteocalcin plasma levels in 30 healthy elderly men (61-88 yr.). 1,25(OH)2D levels and calcium absorption, assessed by oral strontium test, did not change with age with respect to a young control group. PTH was higher (p < 0.02) in the elderly than in the control group, and correlated positively with nephrogenous cAMP levels (p < 0.01; r = 0.65). Radial BMD (measured by single photon absorptiometry) was lower (p < 0.01) in elderly than in young subjects and negatively correlated with age (p < 0.01; r = -0.45). Osteocalcin levels, used as a mark of bone turnover, were unchanged. The data suggest that decreased 1,25(OH)2D levels are not a feature of normal male aging. Senile hyperparathyroidism could compensate for impairments in endogenous metabolism of vitamin D in elderly males and maintain calcium absorption at an efficient level, without increasing bone turnover.

Adult↗

[Variations in the antibiotic sensitivity of bacterial strains after contact with the metals used for the construction of prosthetic implants].

The antibiotic sensitivity of 19 Gram-positive bacterial strains (11 Staphylococcus aureus and 8 Staphylococcus epidermidis) and 16 Gram-negative strains (8 Escherichia coli and 8 Proteus species) was evaluated after contact with stainless steel and with some metals compounding the alloys used for prosthetic devices. The hypothesis was that the resistance to antibiotic therapy of infections associated with prosthetic implants is also due to a modification in the sensitivity of microorganisms. The results, compared to those obtained from control tests, showed only slight variations in the antibiotic sensitivity of the strains put in contact with the metals. In Gram-positive strains, after contact with metals, the increase in sensitivity occurred more frequently than the reduction. In Gram-negative strains, the decrease in sensitivity was more frequent than the increase. Proteus strains showed sensitivity variations more frequently than Escherichia coli strains. Titanium and nickel induced the highest number of variations, both in Gram-positive and Gram-negative strains.

Anti-Bacterial Agents↗

Corneal endothelium cell adhesion on intraocular lenses in vitro.

An in vitro evaluation was conducted of the adhesion capabilities of rabbit corneal endothelial cells on intraocular lenses (IOLs) made of heparin-coated polymethylmethacrylate (HSM-PMMA). The concave endothelial surfaces of albino rabbit corneas were placed in contact in vitro with the convex surfaces of the optical side of HSM-PMMA IOLs in 4-day cultures. PMMA IOLs served as controls. After an incubation period, the preparations were examined via phase-contrast microscopy and via inverted microscopy after staining with vital dye (neutral red), both with and without the cornea in place. After fixation and staining with Giemsa, the cells adherent on the lens were counted on five different microscopic fields. It was observed that the corneal endothelial cells adhered equally to heparin-coated and untreated PMMA IOLs.

Animals↗

Production of prostacyclin and fibrinolysis modulators by endothelial cells cultured in the presence of polyethylene terephthalate.

The aim of this study was the evaluation of the in vitro production of prostacyclin, and of tissue plasminogen activator (tPA) and its inhibitor, PAI-1, by human endothelial cells cultured in the presence of polyethylene terephthalate (PET). After a 48 h contact between the cells and the polymer, the concentration of 6-keto-PGF1 alpha, a stable metabolite of prostacyclin, tPA, and PAI-1, was assayed on the supernatants. Contact of the endothelial cells with PET produced a highly significant reduction of 6-keto-PGF1 alpha with respect to control cultures. Tissue plasminogen activator concentration in the supernatants of the cultures in contact with the material was similar to that observed in the controls, while PAI-1 production was significantly reduced. It can be concluded that the contact between endothelial cells and PET determines a reduction in the platelet aggregability and an increase of the fibrinolytic activity due to a decrease in PAI-1, while tPA concentration remains unchanged.

6-Ketoprostaglandin F1 alpha↗

In vitro evaluation of cell/biomaterial interaction by MTT assay.

The tetrazolium-based colorimetric assay (MTT test) measures only in vitro living cells and the results are directly related to the number of viable cultured cells. It has been adopted in immunological investigations, cancer research and, recently, biocompatibility evaluation. We used the MTT method with minor modifications to fit it to an in vitro study of biomaterial-cell interactions. The MTT assay was confirmed to be feasible, rapid and reproducible. Moreover, it showed a good correlation with other in vitro proliferation assays, such as the 3H-thymidine uptake assay. By using the MTT method and the ASTM procedure for extracting biomaterials, we quantified the in vitro cell compatibility of different metals and polymers.

Biocompatible Materials↗

X-ray diffraction of newly formed bone close to alumina- or hydroxyapatite-coated femoral stem.

The study was focused on the bone tissue response to two types of ceramic coating [alumina and hydroxyapatite (HA)] obtained with a plasma-spray technique. The HA coating was performed on titanium stems, while the alumina coating was on chromium-cobalt-molybdenum stems. The investigation was carried out by means of micro-area X-ray diffractometric analyses and microdiffractometric analyses at the bone-implant interface. Moreover, the coating before and after implantation was analysed by means of the conventional powder X-ray diffractometric technique. This study demonstrated that 1 yr after implantation in animals the newly formed bone adjacent to the HA-coated hip prosthesis stems was mineralized as much as the pre-existing bone, while 24-64 months after surgery in humans the newly formed bone close to the alumina-coated hip prosthesis stems showed a lamellar and Haversian structure strongly demineralized, probably due to the release of aluminum ions from the alumina covering. The authors conclude that the X-ray diffraction allows the evaluation of the structural modifications of the ceramic coating, the bone formation rate close to the coating and the chemical nature of the particles released from the coating.

Aluminum Oxide↗