Search PubMed⌕ Search

Biomedical subjects

A Pinchera

Publications and source records attributed to A Pinchera.

At least 361 records · Page 20Linked to original sources

Surface markers and function of circulating thyroid autoantibody-producing cells.

The in vitro synthesis of antithyroglobulin (anti-Tg) and antithyroid microsomal (anti-M) autoantibodies by peripheral blood mononuclear cells (MNC) from patients with autoimmune thyroid diseases was investigated using sensitive immunoradiometric assays. Cultures were carried out in the presence or in the absence of pokeweed mitogen (PWM). Thyroid autoantibodies were undetectable in supernatants of MNC cultures from 9 normal subjects. Supernatants of MNC cultured without PWM had detectable levels of anti-Tg and anti-M in 5 (19.3%) and in 2 (7.7%) of 26 patients with autoimmune thyroid diseases, respectively. In the presence of PWM, a marked increment in the antibody concentrations occurred in all but 1 of these cultures, and the number of positive cultures increased to 13 (50.1%) for anti-Tg and to 15 (57.7%) for anti-M. Studies of MNC fractions depleted of T lymphocytes (non-T cells) were carried out on selected patients showing antibody synthesis only after PWM stimulation. Autoantibody production was not found with non-T cells, but the effect of the mitogen was restored by readdition of T cells. Irradiation (1000 rad) of T cells before coculturing significantly enhanced autoantibody production. With this model no significant functional difference was found between autologous and allogenic T cells from thyroid autoimmune disease patients or from normal subjects. The cells involved in PWM-driven thyroid autoantibody synthesis, as defined by depletion studies, were lymphocytes bearing DR antigens and surface immunoglobulin G (IgG) without detectable surface immunoglobulin M (IgM). Depletion from MNC suspensions of Tg-binding cells abolished PWM-stimulated anti-Tg production, but did not alter the synthesis of anti-M. Further studies were carried out on MNC from a single patient with Hashimoto's thyroiditis, whose non-T cells consistently produced large amounts of anti-M and total IgG in the absence of PWM. The addition of PWM to these unfractionated MNC slightly increased the production of anti-M, but inhibited antibody synthesis after depletion of T lymphocytes. Interestingly, the addition of autologous T lymphocytes to non-T cells inhibited the spontaneous synthesis of anti-M. These data indicate that in vitro synthesis of anti-Tg and anti-M by MNC may be frequently induced by stimulation with PWM in patients with thyroid autoimmune disorders. PWM-stimulated synthesis of thyroid autoantibodies appears to be T-cell dependent and modulated by radiosensitive T lymphocytes. The cells responsible for PWM-dependent thyroid autoantibody synthesis are B lymphocytes with surface membrane IgG and have receptors specific for the autoantigen.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

A solid phase immunoradiometric assay for gastric parietal cell antibodies.

We recently described a solid phase immunoradiometric assay (IRMA) for anti-thyroglobulin and anti-thyroid microsomal antibodies. In the present study a similar IRMA for gastric parietal cell antibodies (PCA) has been developed. Samples to be tested are incubated within wells of polyvinyl microtitre plates coated with solubilized gastric microsomal antigen. After removal of unbound material, PCA is detected by adding purified 125I-anti-human IgG antibody. A good correlation was found with the results of PCA assays obtained by indirect immunofluorescence. In contrast, negative PCA by IRMA were consistently obtained in sera containing high titres of several other organ specific and non-organ specific autoantibodies. PCA determinations by IRMA were than carried out in a series of normal controls and patients with autoimmune or non-autoimmune thyroid disorders. Positive results were obtained in three of 70 (4.3%) apparently normal subjects, in 16 of 87 (18.4%) patients with Hashimoto's thyroiditis, in 10 of 48 (20.8%) with idiopathic myxoedema, in 25 of 95 (25.6%) with Graves' disease and in five of 64 (7.8%) with other non-autoimmune thyroid disorders. Preliminary results showed that quantitative measurements of PCA by IRMA could be performed using a serum containing high levels of PCA as standard reference. In conclusion, PCA may be easily and specifically detected using the same IRMA procedure previously developed for anti-thyroid antibodies. We therefore suggest that the present IRMA may be proposed as a general technique for the detection of different organ specific autoantibodies.

Autoantibodies↗

TSH-displacing activity versus TSH-binding inhibiting activity of immunoglobulins from patients with Graves' disease.

Inhibition of binding of TSH to thyroid plasma membranes by immunoglobulins G (IgG) from patients with Graves' disease has been interpreted as evidence of an interaction with the TSH receptor, but other explanations may account for this phenomenon. Displacement of receptor-bound TSH might be a more direct index of such an interaction. The aim of the present study was to assess TSH-displacing activity (TDA) of Graves' IgG by a newly developed assay and compare TDA to TSH-binding inhibiting activity (TBIA) and thyroid-stimulating antibody (TSAb) activity. TDA was assessed by preincubating 125I-TSH with thyroid plasma membranes and by measuring residual bound 125I-TSH after addition of IgG. TBIA was evaluated by determining binding of 125I-TSH to thyroid plasma membranes preincubated with IgG. Results were expressed as % TSH-displacing or binding inhibition activities of test IgG with respect to normal control IgG. The percent of TDA positive Graves' IgG preparations (72.7%) was greater than that of TBIA positive (48.5%). There was no correlation between TDA and TBIA results, since 11 Graves' IgG preparations were TDA positive but TBIA negative, and 6 were TDA negative but TBIA positive. Hashimoto's or idiopathic myxedema IgG preparations were positive in 2/7 in the TDA and in 1/7 in the TBIA assays, respectively. Neither TDA nor TBIA correlated with TSAb determined by cAMP accumulation in thyroid plasma membrane. The TDA assay developed in this study appeared to be more sensitive than the more widely used TBIA assay.(ABSTRACT TRUNCATED AT 250 WORDS)

Antibodies↗

Graves' IgG stimulation of iodide uptake in FRTL-5 rat thyroid cells: a clinical assay complementing FRTL-5 assays measuring adenylate cyclase and growth-stimulating antibodies in autoimmune thyroid disease.

With optimal conditions and cells maintained in the absence of thyrotropin (TSH) for 7-10 days, IgG preparations from approximately 90% of patients with active Graves' disease can exhibit statistically significant stimulation of cAMP levels in rat FRTL-5 thyroid cells as compared to normal controls. FRTL-5 cells maintained in the absence of TSH for 7-10 days lose their ability to take up iodide. Iodide uptake returns upon readdition of TSH over a 60-hour period via a cAMP-mediated process; thus TSH can be replaced by dibutyryl cAMP or other agents which increase cAMP levels, for example, thyroid-stimulating autoantibodies (TSAbs) from Graves' sera. TSAb stimulation of iodide uptake requires the continued presence of TSAb over at least the first 24 hours of a 48-hour reversal period; TSH, in contrast, can be withdrawn after 5 hours and will still achieve maximal effects at 36-48 hours. Iodide uptake, measured as a 30-minute pulse at 48 hours, appears, however, to be faster with TSAb than TSH. With optimized conditions (cells depleted of TSH greater than 7-10 days; 3-isobytyl-1-methyl xanthine, 0.005 mM; TSAb addition for the entire 48-hour assay period; and a 30-minute pulse of 10 microM 125I-sodium iodide at 37 C), TSAb stimulation is concentration-dependent with a half-maximal activity at approximately 10-fold lower concentrations than in the cAMP stimulation assay. In a series of 24 patients with Graves' disease, IgGs with positive values in the cAMP assay were positive in the iodide uptake assay.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenylyl Cyclases↗

A new solid phase immunoradiometric assay for antithyroid microsomal antibody.

A new sensitive, quantitative, and specific immunoradiometric assay (IRMA) for antithyroid microsomal (anti-M) antibody has been developed. Samples to be tested are incubated within wells of polyvinyl microtiter plates coated with solubilized thyroid microsomal antigen. After removal of unbound material, anti-M antibody is detected by adding purified [125I]antihuman immunoglobulin G (IgG) antibody. Using 1.0 microliter serum, anti-M antibody was found by IRMA in all of the patients with Hashimoto's thyroiditis or idiopathic myxedema (n = 19), in 86% of those with Graves' disease (n = 42), in 10.9% of subjects with other nonautoimmune thyroid disorders (n = 37), and in 8.4% of normal controls (n = 71). A good correlation was found with the results obtained in anti-M antibody tests by passive hemagglutination. Using larger volumes of serum (up to 100 microliters), anti-M antibody detectable by IRMA was found in some patients with Graves' disease and negative passive hemagglutination tests. Quantitative measurements of anti-M antibody by IRMA could be performed using a standard IgG preparation containing high levels of anti-M antibody. The minimal detectable amount ranged between 1-2 ng IgG, corresponding to a sensitivity 15-30 times greater than that of the competitive binding radioassay. We suggest that the present IRMA may be proposed as a general technique for the detection of different organ-specific autoantibodies.

Animals↗

Orbital cobalt irradiation combined with systemic corticosteroids for Graves' ophthalmopathy: comparison with systemic corticosteroids alone.

The effects of different methods of treatment of Graves' ophthalmopathy were evaluated in a series of 48 patients. Thirty-six patients were given combined treatment with orbital cobalt irradiation and systemic 6 alpha-methylprednisolone (methylprednisolone). Included in this group were 12 of 24 consecutive patients who were randomly assigned to either combined therapy or systemic methylprednisolone alone. The degree of ocular involvement and responses to treatment were evaluated by numerical scoring (ophthalmopathy index) and clinical assessment. Of the 36 patients treated by combined therapy, 12 (33%) showed excellent responses, 14 (39%) showed good responses, 9 (25%) showed slight responses, and 1 (3%) had no response. Treatment was more effective for soft tissue involvement, newly developed ophthalmoplegia, and optic neuropathy, while proptosis and longstanding ophthalmoplegia were less responsive. There was an inverse relationship between the duration of ophthalmopathy and the efficacy of treatment, more favorable results being observed when symptoms had been present for less than 2 yr. Treatment with systemic methylprednisolone alone was also effective, but, in general, responses were less satisfactory; 4 of the 12 patients of this group (33%) had good responses, 6 (50%) had slight responses, and 2 (17%) had no response. The results obtained in the 24 patients randomly assigned to combined therapy or steroid treatment alone were compared by evaluating changes in the ophthalmopathy index. Mean initial ophthalmopathy indices (6.4 vs. 6.2, respectively) showed no significant differences between the 2 groups, whereas the mean decrease in the group receiving combined therapy (4.8) was significantly greater (P less than 0.05) than that in the other group (3.2). In conclusion, the present study indicates that both orbital cobalt irradiation combined with systemic methylprednisolone treatment and systemic methylprednisolone therapy alone are valuable methods of treatment for Graves' ophthalmopathy, but the combined therapy proved to be more effective.

Adolescent↗

Characterization of the optimal stimulatory effects of graves' monoclonal and serum immunoglobulin G on adenosine 3',5'-monophosphate production in fRTL-5 thyroid cells: a potential clinical assay.

Immunoglobulin G (IgG) preparations derived from the sera of patients with hyperthyroidism due to Graves' disease (TSAb) as well as a monoclonal IgG derived from heterohybridoma fusions of Graves' lymphocytes augmented cAMP levels in a continuous strain of functioning rat thyroid cells (clone FRTL-5) in culture. Optimal stimulation was the same for both types of IgG preparations when measured after 2 h of incubation with 5 X 10(4) cells/well and using cells maintained in a nongrowth, TSH-deficient medium for 7 days. At low IgG concentrations, the stimulatory activities of both preparations exhibited a linear dependence on concentration and similar Ka values (approximately 4 X 10(-8) M) despite the fact that 65% of the Graves' serum IgG preparations had a significantly better ability to inhibit TSH binding to membrane preparations. The Ka value for TSH in the same assay was about 5 X 10(-12) M. Using this cell assay, 90% of a series of hyperthyroid Graves' IgG preparations exhibited stimulating activity, a value comparable to the frequency of positive results found by ourselves and others using human thyroid cell and slice systems. In contrast, only 10% of patients who were euthyroid 1 yr after antithyroid drug withdrawal (n = 21) exhibited stimulating activity, and no stimulating activity was detected in patients with nontoxic nodular goiter (n = 11), toxic adenoma (n = 5), or thyroid carcinoma (n = 6). The studies suggest that an optimized rat FRTL-5 thyroid cell system is a clinically useful and convenient alternative to human thyroid cell and slice systems for detecting TSAbs.

Animals↗

A sensitive method for assaying thyroid stimulating immunoglobulins of Graves' disease: use of the guanyl nucleotide-amplified thyroid adenylate cyclase assay.

The purpose of this study was to develop and validate a sensitive method for evaluating adenylate cyclase stimulation by thyroid-stimulating antibodies (TSAb), based on the measurement of thyroid membrane adenylate cyclase activity in the presence of a non-hydrolyzable GTP analogue, guanyl-5'-yl imidodiphosphate (Gpp(NH)p). The addition of Gpp(NH)p (10(-5)M) produced a 10-fold increase of the sensitivity of the system for both TSH and TSAb. Immunoglobulin G preparations from sera of 30 patients with Graves' disease were tested for the adenylate cyclase stimulation either in the presence or in the absence of Gpp(NH)p: a significant stimulation was observed in 27/30 patients when the GTP analogue was added to the system, while only 20/30 patients were positive in the absence of the nucleotide. The advantage of Gpp(NH)p addition was also evident in a large series which included 57 patients with Graves' disease, 15 with Hashimoto's thyroiditis or primary myxoedema and 22 normal subjects. In fact, 88% of patients with Graves' disease resulted positive, while no significant stimulation was elicited by Hashimoto's thyroiditis, primary myxoedema and by normal immunoglobulins. The sensitivity achieved in our system which employs thyroid plasma membranes was similar to that obtained by other investigators with the use of thyroid slices or thyroid cells in primary culture. Furthermore, methods based on thyroid plasma membranes are supposed to have a better reproducibility, since the same tissue preparation, if appropriately stored, may be used in several different tests.

Adenylyl Cyclases↗

Thyroid-stimulating immunoglobulins.

The presence of thyroid-stimulating immunoglobulins in patients with Graves' disease is well established. Considerable evidence has accumulated that these immunoglobulins are antibodies to a thyroid plasma membrane antigen whose precise nature remains to be identified. The question whether the antigen is related to the TSH receptor is still debated. The causative role of thyroid-stimulating immunoglobulins in the hyperthyroidism of Graves' disease is widely recognized. The use of human specific stimulation assays has circumvented the objection of the relatively low frequency of long-acting-thyroid-stimulator-(LATS)-positive patients. Individual variations in the thyroid response may account for the lack of correlation between the levels of thyroid-stimulating immunoglobulins and most parameters of thyroid function. In this respect, the interference of nonstimulatory thyroid antibodies and of other autoimmune mechanisms may be of importance. An important clinical implication of thyroid-stimulating immunoglobulin determinations is their value in predicting the relapse of hyperthyroidism in treated patients. This clinical application has been so far limited by the technical difficulties of the assays. This emphasizes the need for a simple and reliable test, which can be used for routine measurements of thyroid-stimulating immunoglobulins.

Graves Disease↗

[Thyroid-stimulating immunoglobulins. The related antigens].

The presence of thyroid stimulating antibodies (TSAb) in patients with Graves' disease is well established. Considerable evidence has accumulated that these are antibodies to thyroid plasma membrane components related to the TSH receptor. The question of whether thyroid stimulation is mediated by a direct interaction with the TSH binding site is still debated. Recent data obtained by the use of monoclonal antibodies to the TSH receptor are consistent with the view that Graves' immunoglobulins comprise antibodies to at least two different components of the TSH receptor complex, one of which is more strictly related to the binding of TSH and the other to the transmission of the hormonal effect. The causative role of TSAb in the hyperthyroidism of Graves' disease is widely recognized. The use of human specific stimulation assays has circumvented the objection of the relatively low frequency of LATS-positive patients. Individual variations in the thyroid response may account for the lack of correlation between levels of thyroid stimulating immunoglobulins and most parameters of thyroid function. In this respect, the interference of non-stimulatory thyroid antibody and of other autoimmune mechanisms may be of importance. An important clinical implication of TSAb and TSH-binding inhibiting antibody determinations is their prognostic value in predicting the relapse of hyperthyroidism in treated patients. This clinical application has been so far limited by the technical difficulty of the assays. This emphasizes the need for a simple and reliable test, which can be used for routine measurements of TSAb.

Antibodies, Monoclonal↗

Studies on thyroid cell surface antigens using cultured human thyroid cells.

Human thyroid cells in primary culture were used for studies of thyroid cell surface antibodies in patients with thyroid autoimmune disorders. Radioiodinated IgG preparations containing thyroid microsomal antibody (TMAb), thyroid stimulating antibody (TSAb) and/or thyroglobulin antibody (TgAb) were tested for binding to thyroid cells. Binding was observed with radioiodinated IgG from patients with Graves' disease, Hashimoto's thyroiditis and idiopathic myxoedema containing TMAb, irrespective of the presence of TSAb and TgAb, while negative results were obtained with normal IgG. A dose-dependent inhibition of binding to thyroid cells was produced by the addition of the corresponding unlabelled IgG preparations. Evidence for tissue specificity was provided by the absence of binding to human skin fibroblasts used as controls. Preabsorption with human thyroid microsomes completely abolished the binding to thyroid cells of a radioiodinated TMAb positive IgG preparation, while only incomplete removal of the reactivity to thyroid microsomes was produced by preabsorption with thyroid cells. These data suggest that some but not all microsomal antigenic determinants are expressed on the thyroid cell surface. Binding to thyroid cells was also observed with purified TgAb, indicating that thyroglobulin antigenic determinants are present on the surface of thyroid cells. No evidence of binding was obtained with a TSAb positive Graves' IgG preparation with undetectable TMAb and TgAb. Unlabelled IgG preparations containing TMAb from patients with either Hashimoto's thyroiditis or idiopathic myxoedema were shown to inhibit the binding to thyroid cells of radioiodinated TMAb positive Graves' IgG and vice versa. These data indicate that antibodies present in these thyroid autoimmune disorders share common thyroid cell surface antigens. However, the binding of radioiodinated IgG from a patient with idiopathic myxoedema was only partially inhibited by Graves' or Hashimoto's IgG, suggesting that some of the thyroid cell surface antibodies of idiopathic myxoedema may not be detectable in other thyroid autoimmune disorders.

Antibodies↗

Serum myoglobin in primary hypothyroidism and effect of L-thyroxine therapy.

Serum myoglobin (Mb) concentrations have been measured by radioimmunoassay in normal subjects, in hypothyroid patients examined 20 days after withdrawal of thyroid hormone therapy ("short-term" hypothyroidism), and in untreated hypothyroids ("long-term" hypothyroidism). In "short-term" hypothyroids, serum Mb levels were significantly higher (p less than 0.01) than those observed in normal controls, although only a minority or patients showed elevated Mb levels. In "long-term" hypothyroids, serum Mb concentrations were significantly higher than that found in normal controls (p less than 0.0001) and in "short-term" hypothyroids (p less than 0.001). In "long-term" hypothyroidism a significant inverse correlation was found between serum thyroid hormones and Mb, whereas no similar correlation was observed in "short-term" hypothyroidism. The administration of progressively increasing doses of L-T4 untreated hypothyroids was followed by normalization of serum Mb, but serum TSH levels still remained elevated. These data indicate that the duration and the severity of hypothyroidism are important factors in the rise of serum Mb, and that the normalization of serum Mb is faster than that of serum TSH and requires less L-T4 than that needed for normal TSH secretion.

Adolescent↗

Comparison between thyroid stimulating and tsh-binding inhibiting immunoglobulins of Graves' disease.

In the sera of patients with Graves' disease abnormal thyroid 'stimulating' immunoglobulins have been demonstrated by in vivo and in vitro assay systems. Conflicting results have been reported when thyroid stimulating and thyrotrophin (TSH)-binding inhibiting activities have been compared. The present study was performed in forty-nine hyperthyroid Graves' patients to ascertain the relationships among TsH-binding inhibiting immunoglobulins (TBII), measured by a radio-receptor assay, thyroid stimulating antibody(TSAb), assayed by stimulation of adenylate cyclase-cAMP system in human thyroid plasma membranes, and LATS, measured by McKenzie's mouse bioassay.TBII was detected in twenty-one of forty-nine (42.9%), TSAb in thirty-five of forty-nine (71.4%) and LATS in nineteen of forty-nine (38.8%).TBII was also present in four of sixteen (25%) patients with other thyroid autoimmune disorders. When the results obtained with the different techniques were compared, correlation was found between LATS response and TSAb activity ( =0.53, P less than 0.001), while there was no correlation between TSAb and TBII activities and between LATS response and TBII activity. These data conform that TSAb is specific and sensitive marker of Graves' disease and suggest that TBII activity is not necessarily synonymous with thyroid stimulation, and could reflect a different phenomenon concomitantly produced.

Animals↗

Serum thyroglobulin concentrations and 131I whole body scans in the diagnosis of metastases from differentiated thyroid carcinoma (after thyroidectomy).

Measurements of circulating thyroglobulin (hTg) and 131I whole body scan were performed in 101 patients with differentiated thyroid carcinoma who had been subjected to surgical thyroidectomy and 131I ablation of remaining thyroid tissue. All 45 patients with positive scans (i.e. functioning metastases) had elevated hTg concentrations. Of fifty-six patients with negative scans forty-two had undetectable or very low hTg levels and were considered to be free of metastatic thyroid tissue, whereas fourteen showed the presence of non-functioning metastases in the clinical and/or radiological examination. In this group of patients, eleven had elevated serum hTg levels while the other three patients had detectable hTg concentrations within the normal range. These results indicate that serum hTg measurements correlate very well with scan findings and have the added advantage of detecting non-functioning metastases which would not be detected by scanning. We concluded that measurement of serum hTg may be used together with scanning, as the first step in the follow-up of thyroidectomized patients with differentiated thyroid carcinoma.

Adenocarcinoma↗

Plasma dehydroepiandrosterone sulphate in hypothyroid premenopausal women.

Plasma dehydroepiandrosterone sulphate (DHEAS), cortisol (F) and prolactin (PRL) were measured in seventeen premenopausal women with primary hypothyroidism and in fifteen normal premenopausal women. Significantly lower (P < 0.001) DHEAS levels were found in hypothyroid women while F and PRL were in the range of normal controls. No significant relation was found between DHEAS and total thyroxine (T4) and TSH. Our results support the hypothesis that DHEAS secretion is impaired in some women with primary hypothyroidism.

Adult↗