Search PubMed⌕ Search

Biomedical subjects

A Pietersen

Publications and source records attributed to A Pietersen.

17 recordsLinked to original sources

Quality assessment of pacemaker implantations in Denmark.

AIMS: Quality assessment of therapeutic procedures is essential to insure a cost-effective health care system. Pacemaker implantation is a common procedure with more than 500,000 implantations world-wide per year, but the general complication rate is not well described. We studied procedure related complications for all implantations performed in an entire nation over a 3-year period. METHODS AND RESULTS: A prospective study of complications related to 99% of the 5648 primary pacemaker implantations performed in the 12 Danish pacemaker centres in 1997-1999 was carried out. Overall 76% of the patients received a physiological pacemaker system and 91% received the optimal pacing mode according to international guidelines. Perioperative complications requiring reoperation were: haematoma 0.3%, atrial lead related 1.9%, ventricular lead related 1.7%. Late complications requiring reoperation were: infection 02%, atrial lead related 13%, ventricular lead related 1.2%. The complication rate decreased over the study period, but overall the complication rate was higher than expected and showed considerable variation between centres. CONCLUSIONS: Our results demonstrate that sensitive data such as complications related to pacemaker implantations can be collected on a national basis. We suggest that a reoperation rate higher than 3% for atrial as well as ventricular pacing electrodes in the individual implanting centre should cause the centre to evaluate carefully the procedure as well as the performance of the individual implanter.

Adolescent↗

Prolonged QTc interval predicts mortality in patients with Type 1 diabetes mellitus.

AIMS: To evaluate prolonged QTc interval and QT dispersion as predictors of all-cause and cardiovascular mortality after adjustment for well-established risk factors in Type 1 diabetic patients. METHODS: From a cohort of all adult Type 1 diabetic patients, duration of diabetes >or= 5 years, attending the clinic in 1984 and followed in an observational study for 10 years (n = 939), all subjects with resting baseline electrocardiograms were identified (n = 697, 360 males). The QT length was measured and corrected for heart rate (QTc). Maximal QTc length (QTc max) and QT dispersion were determined. RESULTS: At baseline, 431 had normoalbuminuria (< 30 mg/24 h), 138 had microalbuminuria (30-299 mg/24 h) and 128 had macroalbuminuria (>or= 300 mg/24 h) of whom 66 (15%), 35 (25%) and 61 (48%) died during follow-up, respectively (26 (6%), 14 (10%), 21 (16%) from cardiovascular disease). QTc max. was 442 (1.2) ms (mean (SEM)) for survivors and 457 (3.7) in patients who died (P < 0.001). In a Cox proportional hazards model including baseline values of putative risk factors, independent predictors of death were QTc max (P = 0.03), age (P < 0.001), presence of hypertension (P = 0.001), male sex (P < 0.001), log urinary albumin excretion (P < 0.001), smoking (P = 0.04), log serum-creatinine (P < 0.001), height (P < 0.001), low social class (P = 0.04), whereas QT dispersion, heart rate, and HbA1c were not included. In the subgroup with macroalbuminuria, but not for all patients, QTc max was an independent risk factor for cardiovascular mortality. CONCLUSION: QTc prolongation, but not increased QT dispersion, is an independent marker of increased mortality in patients with Type 1 diabetes mellitus.

Adult↗

QTc interval length and QT dispersion as predictors of mortality in patients with non-insulin-dependent diabetes.

Patients with non-insulin-dependent diabetes (NIDDM) are at independent risk of cardiovascular death. The reason is only partially understood. The aim of our study was therefore to evaluate the impact of corrected QT interval length (QTc) and QT dispersion (QT-disp) on mortality in a cohort of 324 Caucasian NIDDM patients. A resting 12-lead ECG was recorded at baseline. Maximum (QT-max) and minimum QT (QT-min) intervals were measured, and QT-max was corrected for heart rate (QTc-max). QT-disp was defined as the difference between QT-max and QT-min. QTc-max was 454 (376-671) ms(1/2) (median (range)) and QT-disp 61 (0-240) ms. Prolonged QTc interval (PQTc), defined as QTc-max > 440 ms(1/2), was present in 67% of the patients and prolonged QT-disp (PQT-disp), defined as QT-disp > 50 ms, was present in 51%. During the 9-year follow-up period, 100 patients died (52 from cardiovascular diseases). Thirty-seven percent of the patients with PQTc died compared with 17% with normal QTc interval (p<0.001). The Cox proportional hazard model, including putative risk factors at baseline, revealed the following independent predictors of all cause mortality; QTc-max (p<0.05), age (p<0.0001), albuminuria (p<0.01), retinopathy (p<0.01), HbA1c (p<0.05), insulin treatment (p<0.01), total cholesterol (p<0.01), serum creatinine (p<0.05) and presence of cardiac heart disease based on Minnesota coded ECG (p<0.001). Whereas QT-disp was not a predictor, QTc-max interval was an independent predictor of cardiovascular mortality. Our study showed a high prevalence of QTc and QT-disp abnormalities and indicated that QTc-max but not QT-disp is an independent predictor of all cause and cardiovascular mortality in NIDDM patients.

Albuminuria↗

Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: an in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation.

The limited success rate of radiofrequency catheter ablation in patients with ventricular tachycardias related to structural heart disease may be increased by enlarging the lesion size. Irrigated tip catheter ablation is a new method for enlarging the size of the lesion. It was introduced in the power-controlled mode with high power and high infusion rate, and is associated with an increased risk of crater formation, which is related to high tissue temperatures. The present study explored the tissue temperatures during temperature-controlled irrigated tip ablation, comparing it with standard temperature-controlled ablation and power-controlled irrigated tip ablation. In vitro strips of porcine left ventricular myocardium were ablated. Temperature-controlled irrigated tip ablation at target temperatures 60 degrees C, 70 degrees C, and 80 degrees C with infusion of 1 mL saline/min were compared with standard temperature-controlled ablation at 70 degrees C and power-controlled irrigated tip ablation at 40 W, and infusion of 20 mL/min. Lesion size and tissue temperatures were significantly higher during all modes of irrigated tip ablation compared with standard temperature-controlled ablation (P < 0.05). Lesion volume correlated positively with tissue temperature (r = 0.87). The maximum recorded tissue temperature was always 1 mm from the ablation electrode and was 67 +/- 4 degrees C for standard ablation and 93 +/- 6 degrees C, 99 +/- 6 degrees C, and 115 +/- 13 degrees C for temperature-controlled irrigated tip ablation at 60 degrees C, 70 degrees C, and 80 degrees C, respectively, and 112 +/- 12 degrees C for power-controlled irrigated tip ablation, which for irrigated tip ablation was significantly higher than tip temperature (P < 0.0001). Crater formation only occurred at tissue temperatures > 100 degrees C. We conclude that irrigated tip catheter ablation increases lesion size and tissue temperatures compared with standard ablation in the temperature-controlled mode at the same or higher target temperatures and in the power-controlled mode. Furthermore, tissue temperature and delivered power are the best indicators of lesion volume during temperature-controlled ablation.

Animals↗

Apoptin.

Tumor cells are often characterized by the traithey are more resistant to apoptosis induced by e.g. cytotoxic agents than normal cells. Resistance to apoptosis induction can be a direct consequence of mutations in certain tumor-suppressor genes (p53) or of certain proto-oncogenes (Bcl-2). Therefore, new cancer therapies are under development to bypass the resistance to chemo- and radio-therapy of tumors. Apoptin acts independently of p53, is stimulated by Bcl-2 and is insensitive to BCR-ABL, which means that Apoptin can induce apoptosis in cases where present (chemo)-therapeutic agents, unfortunately, will fail. The fact that Apoptin induces apoptosis in human tumorigenic cells but not in normal diploid cells, implies that side-effects of Apoptin treatment are expected to be minor. In-vivo results with a first prototype of anti-tumor therapy based on expression of Apoptin indicate that Apoptin has low acute toxicity and is effective as an anti-tumor agent.

Animals↗

Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling.

BACKGROUND: It is important to increase lesion size to improve the success rate for radiofrequency ablation of ischemic ventricular tachycardia. This study of radiofrequency ablation, with adjustment of power to approach a preset target temperature, ie, temperature-controlled ablation, explores the effect of catheter-tip length, ablation site, and convective cooling on lesion dimensions. METHODS AND RESULTS: In vitro strips of porcine left ventricular myocardium during different levels of convective cooling and in vivo pig hearts at 2 or 3 left ventricular sites were ablated with 2- to 12-mm-tip catheters. We found increased lesion volume for increased catheter-tip length </=8 mm in vitro (P<0.05) and 6 mm in vivo (P<0. 0001), but no further increase was found for longer tips. For the 4- to 10-mm catheter tips, we found smaller lesion volume in low-flow areas (apex) than in high-flow areas (free wall and septum) (P<0.05). Increasing convective cooling of the catheter tip in vitro increased lesion volume (P<0.0005) for the 4- and 8-mm tips but not for the 12-mm tip as the generator reached maximum output. In contrast to power-controlled ablation, we found a negative correlation between tip temperature reached and lesion volume for applications in which maximum generator output was not achieved (P<0. 0001), whereas delivered power and lesion volume correlated positively (P<0.0001). CONCLUSIONS: Lesion size differs in different left ventricular target sites, which is probably related to convective cooling, as illustrated in vitro. Longer electrode tips increase lesion size for tip lengths </=6 to 8 mm. For temperature-controlled ablation, the tip temperature achieved is a poor predictor of lesion size.

Animals↗

Temperature-controlled radiofrequency ablation of cardiac tissue: an in vitro study of the impact of electrode orientation, electrode tissue contact pressure and external convective cooling.

BACKGROUND: A variety of basic factors such as electrode tip pressure, flow around the electrode and electrode orientation influence lesion size during radiofrequency ablation, but importantly is dependent on the chosen mode of ablation. However, only little information is available for the frequently used temperature-controlled mode. The purpose of the present experimental study was to evaluate the impact during temperature-controlled radiofrequency ablation of three basic factors regarding electrode-tissue contact and convective cooling on lesion size. METHODS AND RESULTS: In vitro strips of porcine left ventricular myocardium were ablated in a tissue bath. Temperature-controlled ablation at 80 degrees C for 60 s was performed using a 7F 4 mm tip electrode in either perpendicular or parallel contact with the endocardium at a pressure of 10 or 20 g. Increased flow around the electrode was induced by circulating the saline in the tissue bath at a flow-velocity of 0.1 m/s. Lesion volume was determined by cutting lesions in 1 mm thick slices, staining with nitroblue tetrazolium and planimetering. A total of 107 lesions was created. Lesion size was significantly larger for perpendicular electrode orientation compared to parallel for both pressure-settings and both levels of flow around the electrode (p < 0.05). Increased flow around the electrode enlarged lesion size (p < 0.005). Electrode-tissue contact pressure had no significant impact on lesion size. CONCLUSIONS: During temperature-controlled radiofrequency ablation increased external cooling of the electrode tip due to either flow of the surrounding liquid or poor electrode tissue contact, as exemplified by perpendicular versus parallel electrode orientation, increases lesion size significantly. This is in contrast to the impact of these factors during power-controlled ablation due to the lack of increased power-delivery in the latter situation.

Animals↗

Implantation of active can implantable defibrillators in the right pectoral region.

Routinely the active can ICD is placed in the left side pectoral position, which theoretically gives optimal conditions for a low defibrillation threshold. Some patients, however, demand a right pectoral position, which possibly could result in a higher defibrillation threshold. A right pectoral position was used in 3 of 85 active can ICDs implanted in our institution from 1994. The DFT was 12 J in two and 18 J in one patient. Thus, right pectoral implantation is feasible and offers an alternative approach in selected patients.

Adult↗

Lesion size in relation to ablation site during radiofrequency ablation.

This study was designed to investigate the effect of the convective cooling of the tip of the ablation electrode during temperature controlled radiofrequency ablation. In vivo two different application sites in the left ventricle of anaesthetised pigs were ablated and in vitro ablation was performed during two different flow-velocities in a tissue bath, while electrode contact pressure and position were unchanged. Target temperature was 80 degrees C. Obtained tip temperature, power consumption and lesion dimensions were measured. In vivo lesion volume, depth and width were found significantly larger for septal applications than apical applications (p < 0.01) and more power was used (p < 0.001). Obtained tip temperature was significantly lower in the septal applications (p < 0.001). In vitro increased convective cooling by induction of flow yielded larger lesion volume, depth and width (p < 0.01), and had higher power consumptions (p < 0.01). Obtained tip temperature did not differ significantly. For the given chosen target temperature power consumption was positively related to lesion volume (r = 0.66 in vivo and 0.65 in vitro), whereas obtained tip temperature was not (r = -0.49 in vivo and -0.61 in vitro). We conclude that during temperature controlled radiofrequency ablation lesion size differs for septal and apical left ventricular applications. Differences in convective cooling might play an important role in this respect. This is supported by our in vitro experiments, where increased convective cooling by induction of a flow around the electrode tip increases lesion dimensions and power consumptions. Furthermore we conclude that for the given target temperature the power consumption is positively correlated with lesion volume (p < 0.001), whereas the obtained tip temperature is not.

Animals↗

Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate.

INTRODUCTION: In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures < 60% partly due to the limited lesion size after conventional radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion size, but has increased risk of cratering. The present study explores irrigated tip catheter ablation in temperature-controlled mode, target temperature 60 degrees C, using an irrigation rate of 1 mL/min, comparing this to conventional catheter technique, target temperature 80 degrees C. METHODS AND RESULTS: In vivo anesthetized pigs were ablated in the left ventricle. In vitro strips of porcine left ventricular myocardium were ablated in a tissue bath. Lesion volume was significantly larger after irrigated tip ablation both in vivo (544 +/- 218 vs 325 +/- 194 mm3, P < 0.01) and in vitro (286 +/- 113 vs 179 +/- 23 mm3, P < 0.001). The incidence of cratering was not significantly different between the two groups. In vivo, no coagulum formation on part of the catheter tip was seen after irrigated tip ablation as opposed to 52% of the applications with conventional ablation (P < 0.05). CONCLUSION: We conclude that temperature-controlled radiofrequency ablation with irrigated tip catheters using low target temperature and low infusion rate enlarges lesion size without increasing the incidence of cratering and reduces coagulum formation of the tip.

Animals↗

Comparison of threshold values between steroid and nonsteroid unipolar membrane leads.

The aim of this study was to evaluate whether steroid membrane leads can reduce pacing thresholds and thereby save energy as compared to nonsteroid membrane leads. The study was a random sample, double blind test consisting of 90 patients between 49-94 years of age admitted to seven hospitals in Europe for pacemaker implantation. The two leads compared in this study had contoured activated carbon tips covered with ion exchange membranes. The leads were identical except that 30 micrograms of dexamethasone was dissolved in the ion exchange membrane of one of the leads. Normal lead implant procedures were used. Follow-up procedures were conducted at 2 weeks and 1, 3, 6, and 12 months after lead implantation. The pulse generator was programmed to an amplitude of 2.5 or 5 V and a duration of 0.5 msec. The stimulation threshold was measured using the VARIO function. The threshold was measured a total of three times in order to determine the presence of microdislocations. At the 2- and 4-week follow-ups, the stimulation threshold was significantly lower for the steroid leads than for the membrane leads without steroid (0.54 +/- 0.19 vs 0.76 +/- 0.25 V, P = 0.0005; and 0.59 +/- 0.19 vs 0.74 +/- 0.26 V, P = 0.005), but after 3 months, the threshold values were almost the same for both leads.

Aged↗

Continuous oral N-acetylcysteine treatment and development of nitrate tolerance in patients with stable angina pectoris.

The presence of sulfhydryl (SH) groups appears to be fundamental to nitrate-induced vasodilation and N-acetylcysteine (NAC), a sulfhydryl (SH)-donor substance, potentiates hemodynamic responsiveness to nitrates. We investigated the effect of simultaneous administration of NAC and isosorbide dinitrate (ISDN) on development of nitrate tolerance. In a double-blind, randomized, placebo-controlled cross-over study, seven patients with stable angina pectoris were treated for two 8-day periods with ISDN (40 mg four times daily, q.i.d.) together with NAC (controlled release 600 mg q.i.d.) or matching placebo. Bicycle exercise tests were performed before treatment was started, 1 h after treatment was started, and at day 8. After 8-day treatment with ISDN + placebo, responses determined by exercise testing were diminished as compared with responses obtained during acute therapy and did not differ from baseline values, suggesting development of tolerance to ISDN. During treatment with ISDN + NAC, time to 1-mm ST depression was significantly prolonged (441 +/- 44 vs. 381 +/- 40 s, mean +/- SEM) and total ST segment depression significantly reduced (1.9 +/- 0.7 vs. 3.5 +/- 0.8 mm) as compared with baseline values. The reduction in ST segment depression was significantly more pronounced during ISDN + NAC (46%) as compared with ISDN + placebo (23%). Although exercise time and time to angina pectoris were unaffected. NAC augmented the antiischemic effects of ISDN as assessed by ECG. This finding may suggest that development of nitrate tolerance is modified by chronic oral high-dose NAC administration.

Acetylcysteine↗

Effects of acupuncture in moderate, stable angina pectoris: a controlled study.

In order to evaluate the effects of acupuncture in moderate, stable angina pectoris, 49 patients were randomized to either genuine or sham acupuncture. In sham acupuncture needles were inserted into points within the same spinal segment as in genuine acupuncture, but outside the Chinese meridian system. The effect was evaluated from exercise tests, anginal attack rate and nitroglycerin consumption. There were no significant differences between the effects of genuine and sham acupuncture either on exercise test variables or on subjective variables. In patients receiving genuine acupuncture there was a significant increase in exercise tolerance (median 9%) and in delay of onset to pain (median 10%). No significant changes were observed in patients receiving sham acupuncture. Within both groups there was a median reduction of 50% in anginal attack rate and nitroglycerin consumption, and there was no significant difference between the results achieved in the two groups. It is concluded that with the present design it was not possible to demonstrate any significant differences between the effect of genuine and sham acupuncture.

Acupuncture Therapy↗

Elevated pain threshold in patients with effort-induced angina pectoris and asymptomatic myocardial ischemia during exercise test.

The purpose of the present study was to analyze the prevalence of asymptomatic (silent) myocardial ischemia during exercise testing among patients with effort-induced angina pectoris, and further, to compare the pain threshold of patients with symptomatic and asymptomatic myocardial ischemia. A group of 26 patients comprised the study. In half of the patients myocardial ischemia during the exercise testing was silent and in one half it was symptomatic. Asymptomatic myocardial ischemia was defined as an asymptomatic ST-segment depression greater than or equal to 0.1 mV, lasting longer than 60 s during an exercise test. In patients with asymptomatic ischemia the pain thresholds both on toe and finger were significantly higher than in patients with symptomatic ischemia: mean values were 10.1 versus 4.9 mA on the toes, p less than 0.025, and 8.4 versus 2.5 mA on the fingers, p less than 0.01. We conclude that asymptomatic myocardial ischemia during exercise test is seen often in patients with angina pectoris and that this may be due to an increased pain threshold.

Aged↗

Thromboembolism in patients with advanced mitral valve prolapse.

Thromboembolism in mitral valve prolapse (MVP) has been suggested to occur in relation to valvular cul-de-sac recesses and endothelial wear-and-tear denudations. Such pathology would be suspected to be prominent in advanced cases of MVP necessitating open-heart operation. We therefore analysed the prevalence of perivalvular thrombi and episodes of systemic arterial embolism (SE) prior to operation in 21 consecutive patients with MVP and severe valve regurgitation. No perivalvular or left atrial thrombi were found during open-heart surgery, but three of the patients (14%, 3-36% with 95% confidence limits) experienced SE, in one case despite long-term anticoagulation. All cases of SE took place less than 3 months before operation. The results indicate that persistent thrombi are rare in MVP and severe valve regurgitation. However, such patients run a substantial risk of SE when they reach a clinical and haemodynamic stage that makes valve surgery mandatory.

Female↗

Silent myocardial ischaemia and life threatening ventricular arrhythmias.

In a retrospective study of four patients with paroxysmal ventricular tachycardia (VT) induced by silent ischaemia (SI) one case was related to transmural SI secondary to coronary artery spasm and the other cases to subendocardial SI related to non-dynamic coronary artery stenosis. In one patient it was possible simultaneously to document the presence of myocardial ischaemia preceding VT using two independent markers: ECG and thallium scintigraphy. The common feature was attacks of fast polymorphic VT with fainting and intermediate cardiac arrest as the sole clinical manifestation. Attacks at rest occurred in both types of patients, whereas exercise induced attacks were an inconstant feature of SI-VT in non-dynamic coronary artery stenosis. VT suppression was accomplished by anti-ischaemic intervention in three patients: by calcium antagonist medication in the patient with coronary artery spasm, by coronary artery surgery in two cases of non-dynamic artery stenosis. The risk of underdiagnosing SI-VT is discussed. Screening of patients with the aborted cardiac arrest syndrome by ambulatory ECG-monitoring and repeated symptom-limited exercise-ECG is recommended.

Coronary Disease↗

Prediction of cardiac risk in non-cardiac surgery.

This prospective study was carried out to develop a model for the prediction of cardiac risk in non-cardiac surgery. Detailed data were collected concerning the preoperative status of 2609 consecutive patients, who were followed closely during the postoperative course. Fatal or life-threatening cardiac complications occurred in 68 patients (2.6%). By utilizing logistic regression, a model for prediction of cardiac risk was developed. The model contained six significant preoperative predictor variables: Congestive heart failure (with 3 degrees of severity); ischaemic heart disease (with 2 degrees of severity); diabetes mellitus; serum creatinine above 0.13 mmol l-1; emergency operation; and the type of operation (two categories). With this model it seems possible to discriminate between patients with very different levels of cardiac risk.

Adult↗