Search PubMed⌕ Search

Biomedical subjects

A Persson

Publications and source records attributed to A Persson.

At least 19 recordsLinked to original sources

Optimization toward a high-average-brightness soft-x-ray laser pumped at grazing incidence.

We report the near-field imaging characterization of a 10 Hz Ni-like 18.9 nm molybdenum soft-x-ray laser pumped in a grazing incidence pumping (GRIP) geometry with a table-top laser driver. We investigate the effect of varying the GRIP angle on the spatial behavior of the soft-x-ray laser source. After multiparameter optimization, we were able to find conditions to generate routinely a high-repetition-rate soft-x-ray laser with an energy level of up to 3 microJ/pulse and to 6x10(17) photons/s/mm2/mrad2/(0.1% bandwidth) average brightness and 1x10(28) photons/s/mm2/mrad2/(0.1% bandwidth) peak brightness.

Journal Article↗

Laser-wakefield acceleration of monoenergetic electron beams in the first plasma-wave period.

Beam profile measurements of laser-wakefield accelerated electron bunches reveal that in the monoenergetic regime the electrons are injected and accelerated at the back of the first period of the plasma wave. With pulse durations ctau >or= lambda(p), we observe an elliptical beam profile with the axis of the ellipse parallel to the axis of the laser polarization. This increase in divergence in the laser polarization direction indicates that the electrons are accelerated within the laser pulse. Reducing the plasma density (decreasing ctau/lambda(p)) leads to a beam profile with less ellipticity, implying that the self-injection occurs at the rear of the first period of the plasma wave. This also demonstrates that the electron bunches are less than a plasma wavelength long, i.e., have a duration <25 fs. This interpretation is supported by 3D particle-in-cell simulations.

Journal Article↗

Three-dimensional drip infusion CT cholangiography in patients with suspected obstructive biliary disease: a retrospective analysis of feasibility and adverse reaction to contrast material.

BACKGROUND: Computed Tomography Cholangiography (CTC) is a fast and widely available alternative technique to visualise hepatobiliary disease in patients with an inconclusive ultrasound when MRI cannot be performed. The method has previously been relatively unknown and sparsely used, due to concerns about adverse reactions and about image quality in patients with impaired hepatic function and thus reduced contrast excretion. In this retrospective study, the feasibility and the frequency of adverse reactions of CTC when using a drip infusion scheme based on bilirubin levels were evaluated. METHODS: The medical records of patients who had undergone upper abdominal spiral CT with subsequent three-dimensional rendering of the biliary tract by means of CTC during seven years were retrospectively reviewed regarding serum bilirubin concentration, adverse reaction and presence of visible contrast media in the bile ducts at CT examination. In total, 153 consecutive examinations in 142 patients were reviewed. RESULTS: Contrast media was observed in the bile ducts at 144 examinations. In 110 examinations, the infusion time had been recorded in the medical records. Among these, 42 examinations had an elevated bilirubin value (>19 micromol/L). There were nine patients without contrast excretion; 3 of which had a normal bilirubin value and 6 had an elevated value (25-133 micromol/L). Two of the 153 examinations were inconclusive. One subject (0.7%) experienced a minor adverse reaction - a pricking sensation in the face. No other adverse effects were noted. CONCLUSION: We conclude that drip infusion CTC with an infusion rate of the biliary contrast agent iotroxate governed by the serum bilirubin value is a feasible and safe alternative to MRC in patients with and without impaired biliary excretion. In this retrospective study the feasibility and the frequency of adverse reactions when using a drip infusion scheme based on bilirubin levels has been evaluated.

Journal Article↗

Standardized volume rendering for magnetic resonance angiography measurements in the abdominal aorta.

PURPOSE: To compare three methods for standardizing volume rendering technique (VRT) protocols by studying aortic diameter measurements in magnetic resonance angiography (MRA) datasets. MATERIAL AND METHODS: Datasets from 20 patients previously examined with gadolinium-enhanced MRA and with digital subtraction angiography (DSA) for abdominal aortic aneurysm were retrospectively evaluated by three independent readers. The MRA datasets were viewed using VRT with three different standardized transfer functions: the percentile method (Pc-VRT), the maximum-likelihood method (ML-VRT), and the partial range histogram method (PRH-VRT). The aortic diameters obtained with these three methods were compared with freely chosen VRT parameters (F-VRT) and with maximum intensity projection (MIP) concerning inter-reader variability and agreement with the reference method DSA. RESULTS: F-VRT parameters and PRH-VRT gave significantly higher diameter values than DSA, whereas Pc-VRT gave significantly lower values than DSA. The highest interobserver variability was found for F-VRT parameters and MIP, and the lowest for Pc-VRT and PRH-VRT. All standardized VRT methods were significantly superior to both MIP and F-VRT in this respect. The agreement with DSA was best for PRH-VRT, which was the only method with a mean error below 1 mm and which also had the narrowest limits of agreement (95% of cases between 2.1 mm below and 3.1 mm above DSA). CONCLUSION: All the standardized VRT methods compare favorably with MIP and VRT with freely selected parameters as regards interobserver variability. The partial range histogram method, although systematically overestimating vessel diameters, gives results closest to those of DSA.

Analysis of Variance↗

Extreme ultraviolet Fourier-transform spectroscopy with high order harmonics.

We demonstrate a new scheme for extreme ultraviolet (xuv) Fourier-transform spectroscopy based on the generation of two phase-locked high-harmonic beams. It allows us to measure for the first time interferograms at wavelengths as short as 90 nm, and open the perspective of performing high-resolution Fourier-transform absorption spectroscopy in the xuv. Our measurements also demonstrate that a precise control of the relative phase of harmonic pulses can be obtained with an accuracy on an attosecond time scale, of importance for future xuv pump-xuv probe attosecond spectroscopy.

Journal Article↗

Laser-accelerated protons with energy-dependent beam direction.

The spatial distribution of protons, accelerated by intense femtosecond laser pulses interacting with thin target foils under oblique irradiation are investigated. Under certain conditions, the proton beams are directed away from the target normal. This deviation is towards the laser forward direction, with an angle that increases with the level and duration of the amplified spontaneous emission pedestal before the main laser pulse. In addition, for a given laser pulse, this beam deviation increases with proton energy. The observations are discussed in terms of different electron acceleration mechanisms and target normal sheath acceleration, in combination with a laser-controllable shock wave locally deforming the target rear surface.

Journal Article↗

Budesonide as maintenance treatment in Crohn's disease: a placebo-controlled trial.

AIM: To assess the efficacy and safety of budesonide capsules 6 mg daily for prolongation of time to relapse and maintenance of remission in patients with Crohn's disease (CD) affecting the ileum and/or ascending colon. METHODS: In a double-blind, placebo-controlled, multicentre trial, 110 patients with CD, who had previously achieved remission in a placebo-controlled trial of budesonide 9 mg daily, were randomly assigned to receive budesonide 6 mg once daily or placebo for 52 weeks. Primary outcome measure was time to relapse [CD activity index (CDAI) of >150 plus an increase of at least 60 points from study entry or withdrawal due to clinical deterioration]. RESULTS: Median time to relapse was 360 days for budesonide patients; 169 days for placebo patients (P = 0.132). No significant differences were seen between groups in relapse rates at 1 year. Budesonide was safe and well tolerated, with a similar adverse events profile to placebo. CONCLUSION: Patients treated with budesonide 6 mg once daily had a trend towards a prolonged time to relapse and lower CDAI scores compared with patients treated with placebo, but relapse rates were not significantly different at the 1-year end point.

Adolescent↗

Computed tomographic colonography: comparison of two workstations.

PURPOSE: To compare two commercially available computed tomography (CT) colonography systems with respect to interobserver variability, the influence of level of expertise, and the gradual reduction of reviewing time for each system. MATERIAL AND METHODS: Two residents and two radiologists using Siemens CTAPP Colography software and Viatronix V3D-Colon software reviewed supine and prone CT acquisitions from 24 patients in a primary 3D endoluminal view. The observers graded each case with respect to technical quality and diagnostic value, assessed the presence of pathology, and indicated the time spent on the viewing. RESULTS: Significant differences were found in technical quality (P < 0.001) and diagnostic value (P<0.001) depending on which system was used, with higher scores for the Viatronix software. The agreement between specialists tended to be higher than that between residents (kappa=0.63 (0.30-0.95) vs. kappa=0.51 (0.21-0.81)), and the residents gave significantly (P < 0.001) higher scores of technical quality. However, the level of expertise had no significant impact on the assessments. We noted extensive variability in pathological lesions found by the different observers. The number of findings did not differ between workstations, but the viewers tended to report larger polyp sizes with the Viatronix software. The time needed for viewing decreased significantly from the first to the last examination viewed by each observer. CONCLUSION: Both the evaluated systems present trustworthy images of the human colon, but in a primary 3D setting the Viatronix software is favored owing to the user-friendly interface, higher experienced technical quality, and better diagnostic value.

Adult↗

Volume rendering of three-dimensional drip infusion CT cholangiography in patients with suspected obstructive biliary disease: a retrospective study.

The purpose of this study was to evaluate the diagnostic potential of prolonged drip infusion CT cholangiography (DIC-CT) using meglumine iotroxate (Biliscopin) and 3D volume rendering in patients with suspected obstructive biliary disease. From a material of 142 patients who had undergone a drip infusion CT, all cases with a verified surgical or endoscopic retrograde cholangiography (ERC) diagnosis (n=33) were selected. Age-matched controls were selected from the remaining examinations. Three radiologists reviewed all 66 examinations in retrospect, independently as well as in consensus. The image quality and the estimated diagnostic quality were rated as good or moderate in 91% of the 198 reviews. The consensus sensitivity and specificity for diagnosing biliary stones was 88% and 94%, respectively (with sensitivities ranging from 88% to 94% for individual observers, and specificities from 86% to 96%). Two out of three strictures were observed. No false positive strictures were described. The use of volume rendering technique (VRT) improved diagnostic certainty in 28/198 (14%) of the evaluations. The visualization of ductal stones was improved in 18/48 (38%). No differences in diagnostic quality between single and multislice CT were observed. We conclude that a detailed image of the biliary tree with good sensitivity and specificity can be obtained by means of bilirubin-governed infusion time DIC-CT with volume rendering reconstruction.

Adult↗

Evaluation of a skin reference electrode used for intraoral pH measurements in combination with a microtouch electrode.

The aim of this in vivo study was to evaluate a skin reference electrode used with the microtouch method for measurements of intraoral pH. Registrations of plaque pH were made in ten healthy subjects before and up to 30 min after a mouth rinse with 10% sucrose. A microtouch electrode (Beetrode) was used in combination with two different half-cell reference electrodes: a skin silver-silver chloride plate or a glass capillary reference electrode. The skin electrode was placed on the subject's forearm in combination with a conductive gel. The glass capillary electrode, together with one of the test subject's fingers, was placed in a beaker with a 3 M KCl solution. High agreement between the two reference systems resulted in almost identical plaque-pH curves (r=0.97). The mean differences between the two systems at the different time points varied between -0.15 and +0.01 pH units, with an overall mean pH difference of 0.03 pH units. It can be concluded that the use of the skin reference electrode may very well replace the traditional reference electrode used in combination with a microtouch electrode for intraoral use.

Adult↗

Volume rendering compared with maximum intensity projection for magnetic resonance angiography measurements of the abdominal aorta.

PURPOSE: To compare the volume rendering technique (VRT) with maximum intensity projection (MIP) for aortic diameter measurements in MR angiography (MRA) data sets. MATERIAL AND METHODS: Existing contrast-enhanced 3-dimensional MRA and digital subtraction angiography (DSA) data sets from 20 patients were analyzed. In each MRA data set, two aortic diameters were measured using MIP and VRT. Agreement with DSA measurements, dependence on rendering parameters, and interobserver agreement were assessed. RESULTS: Diameters measured on MIP with fixed parameters showed no significant difference compared with DSA and with freely selected parameters a slight overestimation relative to DSA. Diameters measured on VRT were larger than on DSA. For both MIP and VRT, the measurements depended on the chosen parameters. The error relative to DSA was larger for VRT than for MIP with fixed parameters but not with freely chosen parameters. Interobserver agreement did not differ significantly. CONCLUSIONS: VRT is not suitable for diameter measurements of the abdominal aorta with fixed parameter settings but may be useful with user-selected settings.

Aged↗

Measurements before endovascular repair of abdominal aortic aneurysms. MR imaging with MRA vs. angiography and CT.

PURPOSE: 1) To compare measurements obtained with MR imaging (MRI)/contrast-enhanced MR angiography (CE MRA) with measurements obtained with angiography (DSA) and CT, for stent-graft sizing of abdominal aortic aneurysms (AAA). 2) To compare MRA measurements obtained with the two post processing techniques MIP (maximum intensity projection) and VRT (3D volume rendering technique). MATERIAL AND METHODS: The prospective study included 20 consecutive patients with AAA identified by DSA and CT as suitable for endovascular repair. For the study, MRI/CE MRA was performed. Five measurement variables for stent-graft sizing were chosen. Comparisons were made between MRI/CE MRA, DSA and CT, and between observers. Comparisons were also made between MIP and VRT. RESULTS: Significantly shorter lengths were obtained with MRA-MIP than with DSA. Three out of six diameter measurements were significantly smaller on MRI/CE MRA than on DSA and CT. No significant differences were found between the observers. One diameter measurement was significantly smaller on MIP than on VRT, while the other measurements showed no significant differences. CONCLUSION: The length measurements obtained with MRA-MIP were probably more correct than those with DSA. For more reliable diameter measurements with CE MRA, improvements of the technique, including VRT reconstructions and a standardized determination of the vessel boundaries, are needed.

Aged↗

Incidence of endemic ataxic polyneuropathy and its relation to exposure to cyanide in a Nigerian community.

BACKGROUND: The occurrence of ataxic polyneuropathy in an endemic area in south west Nigeria has been attributed to exposure to cyanide from cassava foods. However, it has been shown that the prevalence of ataxic polyneuropathy is not high in several communities in the tropics where exposure to cyanide from cassava foods is high. OBJECTIVES: To determine the incidence of ataxic polyneuropathy in an endemic community, and to compare the intake of cassava foods, exposure to cyanide, and levels of thiols in cases and controls. METHODS: A cohort of 3167 healthy subjects aged 10 years and over in Ososa, Nigeria, was followed for two years, screened, and examined neurologically. Ataxic polyneuropathy was diagnosed if sensory polyneuropathy and sensory gait ataxia were both present. Controls were selected randomly within 10 year age groups of subjects who screened negative. Intake of cassava foods, exposure to cyanide, concentrations of thiols (glutathione, cysteine, and gamma glutamylcysteine) in plasma, and visual evoked potentials were measured. RESULTS: Person-years of follow up were 6246 for 1469 male and 1698 female subjects in the cohort. The incidence of ataxic polyneuropathy was 64 per 10,000 person-years (31 for male and 93 for female subjects). Multivariate odd ratios were 0.78 (95% CI 0.23 to 2.61) for intake of the commonest cassava food, and 1.64 (0.56 to 5.09) for concentration of thiocyanate in plasma. The concentration of thiols was less than the reference limits in two controls, but in none of the cases. The latency of P100 was prolonged in 20 cases (69%) compared with 14 controls (42%) (p<0.05). CONCLUSIONS: The incidence of ataxic polyneuropathy is high in Ososa, Nigeria, but the intake of cassava foods, exposure to cyanide, and levels of thiols, are not related to the occurrence. These findings do not suggest that cyanide is the cause of endemic ataxic polyneuropathy.

Adolescent↗

Age-related deficits in long-term potentiation are insensitive to hydrogen peroxide: coincidence with enhanced autophosphorylation of Ca2+/calmodulin-dependent protein kinase II.

Reactive oxygen species (ROS) can have deleterious effects for both normal aging and Alzheimer's disease (AD). We examined the hypothesis that synapses undergoing long-term potentiation (LTP) are preferentially at risk for ROS-mediated oxidative stress during aging. We observed age-dependent deficits in LTP induced by a high-frequency stimulation (HFS) protocol in the CA1 region of hippocampus from C57BL/6 mice. There was a significant difference between LTP measured over 60 min in young (1-2 months) and old (23-26 months) mice. In oxidative stress studies, exogenous H(2)O(2) (580 micro M) significantly inhibited LTP in young mice; a similar dose of H(2)O(2) failed to inhibit LTP in slices from adult (2-4 months) or from old mice. The results show that there are significant deficits in LTP in aging mice, but such deficits are insensitive to H(2)O(2). Western immunoblotting studies in young mice show that the relative levels of autophosphorylated alpha-Ca(2+)/calmodulin-dependent protein kinase II (CaMKII) are unchanged in hippocampal CA1 treated with H(2)O(2) relative to untreated controls. However with aging, there is a significant enhancement in the levels of autophosphorylated CaMKII in H(2)O(2)-treated CA1 of older mice. Phosphorylation of RC3/neurogranin (Ng) by protein kinase C (PKC) is decreased in CA1 in response to H(2)O(2) treatment, irrespective of age. We propose that, during aging, enhanced local release of H(2)O(2) from mitochondria may induce a compensatory "ceiling" effect at synapses, so that the levels of autophosphorylated alpha CaMKII are aberrantly saturated, leading to alterations in synaptic plasticity.

Aging↗

Time-frequency characterization of femtosecond extreme ultraviolet pulses.

We present energy-resolved cross-correlation measurements of an extreme ultraviolet (XUV) pulse, generated as the fifth harmonic (15.5 eV) of an intense 80 fs laser pulse centered at 400 nm. Spectrally resolving the cross-correlation signal allows us to characterize the time-dependent frequency of the XUV pulse. We find that the fifth harmonic has a small negative chirp in excess of that predicted by perturbation theory. In addition, by manipulating the chirp of the driving laser we can induce and measure a positive or a negative chirp on the XUV pulse.

Journal Article↗

Low prevalence of ataxic polyneuropathy in a community with high exposure to cyanide from cassava foods.

INTRODUCTION: Ataxic polyneuropathy, which occurs in endemic form in an area in southwest Nigeria, is attributed to exposure to cyanide from cassava foods. Exposure to cyanide from cassava is, however, not exclusive to this endemic area. In this study, the occurrence of ataxic polyneuropathy was compared in two communities in Nigeria, one located in the endemic area and the other located outside the endemic area. Both communities have been shown to have high exposure to cyanide from cassava foods. METHOD: The prevalence of ataxic polyneuropathy in Jobele, Nigeria, a community located outside the endemic area, was compared with the prevalence of ataxic polyneuropathy in Ososa, Nigeria, a reference community located in the endemic area. Subjects aged 10 years and above in both communities were screened for ataxic polyneuropathy. Ataxic polyneuropathy was diagnosed if sensory gait ataxia and sensory polyneuropathy were present. The intake of cassava foods, biomarkers of exposure to cyanide, and intake of protein and sulphur were measured. RESULTS: Prevalence of ataxic polyneuropathy were 490 per 10,000 in Ososa, and 17 per 10,000 in Jobele. The age-adjusted prevalence ratio is 4 (95% CI 0-9). The mean intake of all cassava foods in Jobele was 7 meals/person/week (95% CI 6-8), while the mean intake of all cassava foods in Ososa was 10 meals/person/week (95 % CI 9-11). The concentration of thiocyanate in the plasma was above the reference limit in 65% (95% CI 57-73) in Jobele, and 40 % (95% CI 27-52) in Ososa. The intake of protein was significantly lower in Ososa than in Jobele, but the concentrations of glutathione, cysteine and gamma-glutamylcysteine in the plasma were within the same range in Jobele and Ososa. CONCLUSION: This study shows that the occurrence of ataxic polyneuropathy is low in a community where exposure to cyanide is high. This suggests that exposure to cyanide is not a direct cause of ataxic polyneuropathy.

Adolescent↗