Search PubMed⌕ Search

Biomedical subjects

A Perel

Publications and source records attributed to A Perel.

At least 19 recordsLinked to original sources

Comparison of stroke volume (SV) and stroke volume respiratory variation (SVV) measured by the axillary artery pulse-contour method and by aortic Doppler echocardiography in patients undergoing aortic surgery.

BACKGROUND: The goal of the study was to compare stroke volume (SV) and respiratory stroke volume variation (SVV) measured by pulse-contour analysis and aortic Doppler. METHODS: These were measured by pulse-contour analysis and thermodilution (PiCCO) and by aortic pulsed wave Doppler with transoesophageal echocardiography in patients undergoing abdominal aortic surgery. Simultaneous measurements were done at different times of surgery. All data were recorded on PiCCOwin software and videotape and analysed off-line by a blinded investigator. RESULTS: A total of 114 measurements were achieved in 20 patients. There was a good correlation and small bias between the PiCCO and the echo-Doppler values of the mean SV [r=0.885; bias=0.2 (8) ml], and between the minimum [r=0.842; bias=1 (9) ml] and maximum SV [r=0.840; bias=2 (10) ml] values. CONCLUSIONS: There is a fair correlation between pulse-contour analysis and aortic Doppler for beat-by-beat measurement of SV but not for calculation of SV respiratory ventilation.

Aorta, Abdominal↗

The implementation of an anesthesia information management system.

BACKGROUND AND OBJECTIVE: Anaesthesia information management systems, though still not used widely, will inevitably replace handwritten records and may eventually serve as a core for the development of computerized decision support. We investigated staff expectations and the accuracy of data entry in a recently implemented commercially available anaesthesia information management system. METHODS: A structured questionnaire was administered to the staff before and 1 week and 3 months after implementation in order to assess their opinion. The quality of manual data entry, and of automatic data record was evaluated by looking for missing data and the prevalence of artefacts. RESULTS: Despite initial fears the users quickly accepted the system. Both automatic and manual data entry were found to be accurate and reliable while the prevalence of artefacts was relatively low. CONCLUSIONS: A commercially available anaesthesia information management system can be easily implemented and used instead of paper charts.

Adult↗

A novel point-of-care information system reduces anaesthesiologists' errors while managing case scenarios.

BACKGROUND AND OBJECTIVES: The On-Line Electronic Help (OLEH) is a point-of-care information system for anaesthesia providers prepared by the European Society of Anaesthesiologists. In this preliminary study the effect of the OLEH availability on the incidence of knowledge-based errors during the management of case scenarios and participants' subjective evaluation of the OLEH were evaluated. METHODS: After a short training session, 48 anaesthesiologists (24 junior residents, 12 senior residents and 12 board-certified) were presented randomly with six computer screen-based case scenarios with, and six without, the option of using the OLEH. Two reviewers evaluated the answers independently according to preconfigured guidelines. RESULTS: The availability of the OLEH was associated with higher scores in 11 of the 12 scenarios, and with a decrease in the incidence of critical errors in 10 scenarios. Time to task completion was increased in one scenario only when the OLEH was used. The degree of professional experience was associated with better scores in five of the scenarios and with a reduced occurrence of critical errors in three scenarios. Forty-two out of 48 participants stated that finding information in the OLEH software was easy and that the system was helpful in managing the scenarios. CONCLUSIONS: This preliminary study demonstrates the potential value of the OLEH in decreasing the number of knowledge-based errors made by anaesthesiologists. According to the encouraging results, the OLEH system is currently under evaluation using full-scale simulation scenarios in an operating room environment.

Anesthesia↗

Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs.

BACKGROUND: Similarly to systolic pressure variation (SPV), pulse pressure variation (PPV) and stroke volume variation (SVV) derived from arterial pulse contour analysis have been shown to reflect fluid responsiveness in ventilated patients. However, unlike the SPV, both PPV and SVV have not been validated during extreme hypovolaemia. The aim of the present study was to examine whether these newly introduced variables respond to gradual hypovolaemia like the SPV by increasing gradually with each step of the haemorrhage even during extreme hypovolaemia. METHODS: SPV, SVV and PPV were measured in 8 dogs following initial volume loading (10% of the estimated blood volume administered as colloid solution), 5 steps of graded haemorrhage, each consisting of 10% of the estimated blood volume, followed by retransfusion of the shed blood. RESULTS: The correlations of the SVV, SPV and PPV to the stroke volume (SV) throughout the study were -0.89, -0.91 and -0.91, respectively. Correlations of the CVP and the global end-diastolic volume (GEDV) of the heart chambers to the SV were 0.79 and 0.95, respectively. The SPV correlated significantly with both the PPV and the SVV (r=0.97 and 0.93 respectively). However, the PPV increased by more than 400% at 50% haemorrhage compared with increases of 200% and 120% for the SVV and %SPV, respectively. CONCLUSION: This study demonstrates that the present algorithm used for the calculation of the SVV and the formula used to calculate the PPV, perform well over a wide range of preload states including severe hypovolaemia. However, the PPV changes more than the SPV and SVV. This may be due to the changing relation of the SV to the pulse pressure when the filling of the aorta is greatly decreased.

Algorithms↗

Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators.

BACKGROUND: Prediction of the response of the left ventricular stroke volume to fluid administration remains an unsolved clinical problem. We compared the predictive performance of various haemodynamic parameters in the perioperative period in patients undergoing coronary artery bypass surgery. These parameters included static indicators of cardiac preload and functional parameters, derived from the arterial pressure waveform analysis. These included the systolic pressure variation (SPV) and its delta down component (dDown), pulse pressure variation (PPV), stroke volume variation (SVV), and a new parameter, termed the respiratory systolic variation test (RSVT), which is a measure of the slope of the lowest systolic pressure values during a standardized manoeuvre consisting of three successive incremental pressure-controlled breaths. METHODS: Eighteen patients were included into this prospective observational study. Seventy volume loading steps (VLS), each consisting of 250 ml of colloid administration were performed before surgery and after the closure of the chest. The response to each VLS was considered as a positive (increase in stroke volume more than 15%) or non-response. Receiver operating characteristic curves were plotted for each parameter to evaluate its predictive value. RESULTS: All functional parameters predicted fluid responsiveness better than the intrathoracic blood volume and the left ventricular end-diastolic area. Parameters with the best predictive ability were the RSVT and PPV. CONCLUSIONS: Functional haemodynamic parameters are superior to static indicators of cardiac preload in predicting the response to fluid administration. The RSVT and PPV were the most accurate predictors of fluid responsiveness, although only the RSVT is independent of the settings of mechanical ventilation.

Aged↗

Anaesthesiologists' views on the need for point-of-care information system in the operating room: a survey of the European Society of Anaesthesiologists.

BACKGROUND AND OBJECTIVE: In this preliminary study we wanted to explore the attitudes of anaesthesiologists to a point-of-care information system in the operating room. The study was conducted as a preliminary step in the process of developing such a system by the European Society of Anaesthesiologists (ESA). METHODS: A questionnaire was distributed to all 2240 attendees of the ESA's annual meeting in Gothenburg, Sweden, which took place in April 2001. RESULTS: Of the 329 responders (response rate of 14.6%), 79% were qualified specialists with more than 10 yr of experience (68%), mostly from Western Europe. Most responders admitted to regularly experiencing lack of medical knowledge relating to real-time patient care at least once a month (74%) or at least once a week (46%), and 39% admitted to having made errors during anaesthesia due to lack of medical information that can be otherwise found in a handbook. The choice ofa less optimal but more familiar approach to patient management due to lack of knowledge was reported by 37%. Eighty-eight percent of responders believe that having a point-of-care information system for the anaesthesiologists in the operating room is either important or very important. CONCLUSIONS: This preliminary survey demonstrates that lack of knowledge of anaesthesiologists may be a significant source of medical errors in the operating room, and suggests that a point-of-care information system for the anaesthesiologist may be of value.

Adult↗

Cardiac output assessed by arterial thermodilution during exsanguination and fluid resuscitation: experimental validation against a reference technique.

BACKGROUND AND OBJECTIVE: The arterial thermodilution technique offers the ability to measure cardiac output using only central venous and arterial catheters. However, the technique has been reported to overestimate cardiac output because of a higher loss of cold indicator due to the increased distance between the sites of injection and measurement. In this study, the two techniques were compared with respect to conditions of low cardiac output in which a longer passage time may further increase loss of indicator. METHODS: Seventeen anaesthetized dogs were studied during hypovolaemic shock and fluid resuscitation. Cardiac output measurements were carried out simultaneously by arterial and pulmonary artery thermodilution techniques. RESULTS: One-hundred-and-two measurements were performed. The mean cardiac output was 2.28 +/- 1.4Lmin(-1) by the pulmonary arterial technique and 2.29 +/- 1.56Lmin(-1) by the arterial thermodilution technique. The correlation coefficient between the two measurements was 0.95, the precision -0.04 +/- 0.41 Lmin(-1) and the limits of agreement from -0.86 to 0.78Lmin(-1). The agreement was also consistent at low cardiac outputs. CONCLUSIONS: The arterial thermodilution technique may serve as a less invasive cardiac output monitor in conditions of severe bleeding and shock.

Animals↗

Left ventricular preload and function during graded haemorrhage and retranfusion in pigs: analysis of arterial pressure waveform and correlation with echocardiography.

BACKGROUND: Arterial pressure waveform analysis is a new method for assessment of cardiac preload. Despite the close correlation of parameters derived by its use with the degree of blood loss, their relationship with more precise estimates of cardiac preload remains controversial. METHODS: Systolic pressure variation (SPV), delta up (dUp), and delta down (dDown), which are the changes in the arterial blood pressure (BP) during mechanical ventilation, were measured during graded haemorrhage and retransfusion in seven pigs under light halothane anaesthesia, and compared with changes in cardiac filling pressures and left ventricular end-diastolic volume (LVEDV), measured by echocardiography. RESULTS: Significant changes in preload parameters and stroke volume (SV) but not in BP and heart rate occurred. SPV, dDown, and cardiac filling pressures correlated significantly with LVEDV. Following retransfusion, LVEDV returned to baseline values but the SV and left ventricular ejection fraction were significantly low. This deterioration in myocardial performance was associated with elevated dUp. CONCLUSIONS: During mechanical ventilation, dDown and the SPV may serve as minimally invasive indicators of preload. The retransfusion stage that follows significant blood loss may be associated with deterioration in LV function.

Animals↗

Effect of a single dose of esmolol on the bispectral index scale (BIS) during propofol/fentanyl anaesthesia.

BACKGROUND: Esmolol, a short-acting beta 1-antagonist, can reduce anaesthetic requirements and decrease seizure activity during electroconvulsive therapy even after a single dose of 80 mg. We studied the effect of esmolol on the bispectral index scale (BIS), which is a processed EEG recently introduced to monitor depth of anaesthesia. METHODS: We gave esmolol 80 mg to 30 healthy male patients after induction of anaesthesia using propofol, with either fentanyl (group 1) or placebo (group 2). Patients were ventilated mechanically through a laryngeal mask airway and anaesthesia was maintained using propofol to keep the BIS value between 55 and 60. RESULTS: Esmolol did not affect the BIS index value in either group. In group 1, the areas (mean (SD)) under the BIS vs time curve 3 min before and 3 min after esmolol administration were 145 (9) and 146 (8) respectively (P = 0.116). In group 2 values were 147 (8) and 146 (7) respectively (P = 0.344). In contrast, in group 1 the area under the systolic arterial pressure (SAP) curve was 299 (31) before and 270 (29) after esmolol (P < 0.001), and 156 (17) and 141 (17) respectively for heart rate (P < 0.001). In group 2 values were 326 (36) and 302 (41) for SAP (P < 0.001) and 182 (25) and 155 (22) for heart rate (P < 0.001). CONCLUSIONS: The results suggest that a single dose of esmolol affects the SAP and heart rate but does not affect BIS values.

Adolescent↗

Malignant hyperinflation of the nondependent lung during chest surgery.

Unilateral malignant hyperinflation of the lungs during positive pressure mechanical ventilation was described during aggressive respiratory therapy of unilateral lung disease or in situations of significant difference in compliance between the two lungs. We report a case of malignant hyperinflation of the nondependent lung during chest surgery. The differential diagnosis and treatment with differential lung ventilation are described.

Aged↗

Propofol/remifentanil versus propofol alone for bone marrow aspiration in paediatric haemato-oncological patients.

BACKGROUND: This prospective randomized study was designed to evaluate the effects of adding remifentanil to the standard propofol-based technique in the setting of paediatric haematology-oncology outpatient clinic. METHODS: Eighty ASA III paediatric patients treated in the outpatient haematology-oncology clinic requiring bone marrow aspiration were randomly assigned either to the propofol (P) or the propofol/remifentanil (PR) group. The quality of anaesthesia and recovery were evaluated. RESULTS: The total amount of propofol required to prevent patient movement was lower in the PR group. The time interval to eye opening and to home readiness was significantly lower in the PR group. Adverse respiratory events (RR < 10.min-1 or SpO2 < 90%) occurred significantly more in the propofol/remifentanil group. CONCLUSIONS: The addition of remifentanil improved the conditions during the procedure and reduced the total amount of propofol, as well as the time to home readiness. However, the addition of remifentanil is associated with an increased risk of respiratory depression.

Adolescent↗

Pressure versus volume-controlled ventilation with a laryngeal mask airway in paediatric patients.

BACKGROUND: The utility of positive pressure ventilation with the laryngeal mask airway (LMA) in children was described previously, but the possibility of gastric insufflation, related to high peak airway pressure, continues to be a disadvantage. In this prospective study, inspiratory pressures, air leak and signs of gastric insufflation were compared between volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) using an LMA. METHODS: Thirty-two ASA I patients, aged 4.5 +/- 4 years, who were scheduled for elective procedures under combined general anaesthesia and caudal analgesia, were enrolled. After inhalation induction and LMA insertion, each patient was randomly assigned to receive successively PCV and VCV. Peak pressures (PCV) and tidal volumes (VCV) were changed in order to achieve adequate ventilation [endtidal CO2 5-5.4 kPa (38-42 mmHg)]. RESULTS: Peak airway pressures were significantly lower with PCV than VCV (14.1 +/- 1.6 cmH2O versus 16.7 +/- 2.3 cmH2O, P < 0.001). No patient ventilated with PCV required peak pressure higher than 20 cmH2O compared with six patients ventilated with VCV (P < 0.05). Haemodynamic parameters, expiratory tidal volume and percent of leak were similar in both ventilatory modes and no signs of gastric insufflation were detected. CONCLUSIONS: During general anaesthesia in children using an LMA, PCV offers lower peak inspiratory airway pressures while maintaining equal ventilation compared with VCV. Although no signs of gastric insufflation were detected in both groups, the lower pressures might be significant in patients with reduced chest wall or lung compliance.

Adolescent↗

Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery.

UNLABELLED: Changes in arterial blood pressure induced by mechanical ventilation allow assessment of cardiac preload. In this study, stroke volume variation (SVV), which is the percentage change between the maximal and minimal stroke volumes (SV) divided by the average of the minimum and maximum over a floating period of 30 s, continuously displayed by the PiCCO continuous cardiac output monitor, was evaluated as a predictor of fluid responsiveness. Fifteen patients undergoing brain surgery were included. During surgery, graded volume loading was performed with each volume loading step (VLS) consisting of 100 mL of 6% hydroxyethylstarch given for 2 min. Successive responsive VLSs were performed (increase in SV > 5% after a VLS) until a change in SV of < 5 % was reached (nonresponsive). A total of 140 VLSs were performed. Responsive and nonresponsive VLSs differed in their pre-VLS values of systolic blood pressure, SV, and SVV, but not in the values of heart rate and central venous pressure. By using receiver operating characteristic analysis, the area under the curve for SVV (0.870, 95% confidence interval [CI]: 0.809 to 0.903) was statistically more than those for central venous pressure (0.493, 95% CI: 0.397 to 0.590, P = 7 x 10(-10)), heart rate (0.593, 95% CI: 0.443 to 0.635, P = 5.7 x 10(-10)), and systolic blood pressure (0.729, 95% CI: 0.645 to 0.813, P: = 4.3 x 10(-3)). An SVV value of 9.5% or more, will predict an increase in the SV of at least 5% in response to a 100-mL volume load, with a sensitivity of 79% and a specificity of 93%. IMPLICATIONS: Stroke volume variation may be used as a continuous preload variable and in combination with the continuously measured cardiac output, defining on-line the most important characteristics of cardiac function, allowing for optimal fluid management.

Aged↗

Anesthesia for magnetic resonance guided neurosurgery: initial experience with a new open magnetic resonance imaging system.

The authors present their initial experience with a compact open magnetic resonance (MR) image-guided system, (PoleStar N-10, Odin Medical Technologies, Yokneam, Israel) used in a standard operating room, modified for radio frequency (RF) shielding. The low intensity of the magnetic field (0.12T), and the ability to lower the magnet from the operative field during surgery allows for an almost routine surgical procedure, in addition to the benefits of using intraoperative MR imaging. Although an MR compatible anesthesia machine and monitoring system are used, the system offers anesthesiologists access to the patient at all times during the procedure, and the ability to use conventional surgical equipment, syringe pumps, and warming devices. Propofol and remifentanil, used for maintaining anesthesia, allow early extubation and neurological evaluation at the end of surgery. Electrocorticographic monitoring can be used during surgery for epilepsy, and awake craniotomy can be performed. More experience with this new imaging system is required to assess its influence on clinical decision making and outcome.

Adolescent↗

Monitored anesthesia care using remifentanil and propofol for awake craniotomy.

Adequate analgesia and sedation with adequate respiratory and hemodynamic control are needed during brain surgery in awake patients. In this study, a protocol using clonidine premedication, intraoperative propofol, remifentanil, and labetalol was evaluated prospectively in 25 patients (aged 50 +/- 16). In all but one patient, no significant problems regarding cooperation, brain swelling, or loss of control were noticed, and it was not necessary to prematurely discontinue any of the procedures. One patient, who was uncooperative and hypertensive, became apneic with increasing sedation, and needed a laryngeal mask airway inserted. Patients were hemodynamically stable; elevated systolic blood pressure (>or= 150 mm Hg) was measured infrequently, and there were no events of significant hypotension, tachycardia, or bradycardia. Events of hypoxemia (SAO2 <or= 95%), severe hypoxemia (SaO2 <or= 90%), or hypoventilation (respiratory rate <or=8 minute), were frequent in the first ten patients, but the incidence decreased significantly in subsequent patients (P < .001). Three patients developed a focal neurologic deficit, and two patients experienced intraoperative seizures. Nausea and vomiting were not recorded in any of the patients. Although these findings attest to the safety of awake craniotomy, they demonstrate the difficulty of achieving adequate sedation without compromising ventilation and oxygenation. The learning curve of using a new protocol and a new potent anesthetic drug is emphasized.

Analgesics, Opioid↗

Diffuse alveolar hemorrhage in acute promyelocytic leukemia patients treated with ATRA--a manifestation of the basic disease or the treatment.

All-trans-retinoic acid (ATRA) is considered the recommended induction treatment for acute promyelocytic leukemia. In the pre-ATRA era pulmonary bleeding was a common cause of death in these patients, mostly due to disseminated intravascular coagulation which was further exacerbated by the administration of chemotherapy. Although ATRA syndrome, the most serious adverse effect of ATRA treatment, involves the lungs, pulmonary hemorrhage has only rarely been reported as a manifestation of ATRA syndrome. Here we describe 2 patients who developed diffuse alveolar hemorrhage during treatment with ATRA. The possible mechanisms of pulmonary bleeding in these cases are discussed.

Adult↗