Search PubMed⌕ Search

Biomedical subjects

A Pavie

Publications and source records attributed to A Pavie.

At least 55 records · Page 3Linked to original sources

Left centrifugal pump cardiac assist with transseptal percutaneous left atrial cannula.

Left cardiac support postcardiotomy requires a second operation for removal of the atrial cannula following weaning from assistance. To avoid the risk of this procedure, we used a transseptal cannula prototype. The cannula was introduced percutaneously through the femoral vein and advanced into the left atrium guided by the finger of the surgeon. Optimal positioning of the tip of the cannula was verified by perioperative transesophageal echocardiography. A long arterial cannula was positioned in the descending aorta via the femoral artery and a Carmeda circuit with a centrifugal pump was connected to both cannulas. This procedure was used in 3 patients with low cardiac output who underwent emergency surgery, a 63-year-old patient referred for aortic and mitral valve replacement, a 54-year-old man for aortic valve replacement, and a 64-year-old patient in the acute phase of myocardial infarction after myocardial revascularization. The assistance was used systematically at the end of the operation. The assist flow was 1.2-2.6 L/min. The patients were all weaned from support between 18 h and 8 days later. No complications related to the device occurred. Both cannulas were removed surgically from the femoral vessels without reopening the chest. This new procedure is of interest for 2 reasons: the systematic implantation allows for early assistance, and the use of a percutaneous approach avoids the risk of reopening the chest. More cases are needed to confirm this initial good impression.

Aortic Valve Insufficiency↗

La Pitié heart transplantation: 30-year single center clinical experience.

At La Pitié Hospital, 1,184 patients underwent cardiac transplantation for end-stage cardiac disease (1,122 orthotopic and 62 heterotopic) between April 1968-November 1998. Since April 1986, 140 patients have been supported using several different mechanical assist devices as a bridge to transplantation. Twenty-four retransplantations (2.2%) were performed for primary graft failure in 4 (17%), refractory acute rejection in 7(29%), coronary graft disease in 11 (46%) and others in 2 (8%) patients. In a case-control study, retransplanted patients were matched with first transplant patients and survival rates at one and 5 years were 59.4% and 38.8% compared with survival rates for retransplanted patients of 45.4% and 31.2%, respectively. Seventy-four patients survived more than 10 years (61 males, 13 females). Mortality did not increase after 10 years. Unfortunately many suffered complications: 77% had hypertension, hypercholesterolemia (22%), hyperuricemia (41%), osteoporosis (11%), osteonecrosis (5%) and diabetes (7%). Renal function remains one of the main problems; 16% had a creatinine > 180 mumol/L and patients are on chronic dialysis.

Actuarial Analysis↗

[The cardiowest total artificial heart: experience of 29 cases].

The authors studied the outcome of multi-organ failure in 29 patients with terminal cardiac failure and maintained with a Cardiotest total artificial heart whilst waiting for cardiac transplantation. Pre-implantation organ dysfunction was defined by the following criteria; assisted respiration of over 3 days, total billirubin and creatinine levels of over 2 mg/dL, a platelet count of less than 80,000/mL or a prothrombin ratio of less than 50% and central nervous system disturbances. Fourteen patients died during the period of circulatory assistance and 71% of deaths were due to multi-organ failure. Pre-implantation plasma total bilirubin levels were significantly higher in patients who died of multi-organ failure (p = 0.04). Eighty per cent of patients who died of multi-organ failure had at least 3 criteria of organ dysfunction before implantation of the artificial heart compared with only 37% in the other patients (p = 0.04). Finally, systemic vascular resistances before implantation were significantly lower in patients who died of multi-organ failure. The results of this study suggest that multi-organ failures does not develop during the period of circulatory assistance but represents an aggravation of a preexisting morbid condition. This observation should lead to a limitation of the indications of total circulatory assistance in some cases and, above all, to earlier intervention before multi-organ failure becomes irreversible.

Adult↗

Cardiac calcium release channel (ryanodine receptor) in control and cardiomyopathic human hearts: mRNA and protein contents are differentially regulated.

Abnormal intracellular calcium handling in cardiomyopathic human hearts has been associated with an impaired function of the sarcoplasmic reticulum, but previous reports on the gene expression of the ryanodine receptors (Ry2) are contradictory. We measured the mRNA levels, the protein levels and the number of high affinity [3H]ryanodine binding sites in the left ventricle of non-failing (n = 9) and failing human hearts [idiopathic dilated (IDCM n = 16), ischemic (ICM n = 7) or mixed (MCM n = 8) cardiomyopathies]. Ry2 mRNA levels were significantly reduced in IDCM (-30%) and unchanged in MCM and ICM and Ry2 protein levels were similar. In contrast, we observed a two-fold increase in the number of high affinity Ry2 (B(max) = 0.43 +/- 0.11 v 0.22 +/- 0.13 pmol/mg protein, respectively; P<0.01) and an unchanged K(d). Furthermore, levels of myosin heavy chain mRNA and protein per g of tissue were similar in failing and non-failing hearts, suggesting that the observed differences in Ry2 are not caused by the increase in fibrosis in failing heart. Therefore, the dissociation between the two-fold increase in the number of high affinity ryanodine receptors observed in all failing hearts and the slightly decreased mRNA level or unchanged protein level suggests that the ryanodine binding properties are affected in failing myocardium and that such modifications rather than a change in gene expression alter the channel activity and could contribute to abnormalities in intracellular Ca2+ handling.

Adult↗

Active native valve endocarditis: determinants of operative death and late mortality.

BACKGROUND: In this report, we reviewed 247 patients who underwent operation by our team for active native valve endocarditis between January 1979 and December 1993. METHODS: There were 201 male and 46 female patients (mean age, 45.4 +/- 6 years). The aortic valve was involved in 163 cases, the mitral valve in 36 cases, both mitral and aortic valves in 44 cases, and the tricuspid valve alone in 4 cases. The most common microorganisms were streptococci. Univariate Pearson (chi2 test) and multivariate (stepwise logistic regression [BMDPLR]) analyses were used to identify significant predictors of operative mortality, reoperation, and recurrent endocarditis. Cox proportional hazards regression model was used to study late survival. RESULTS: Operative mortality was 7.6% (n = 19). Increased age, cardiogenic shock at the time of operation, insidious illness, and greater thoracic ratio (>0.5) were the predominant risk factors; the length of antibiotic therapy appeared to have no influence. Two hundred thirteen patients were followed up. Median follow-up time was 6 years (range, 2 to 19 years). Overall survival rate (operative mortality excluded) was 71.3% +/- 3.8% at 9 years. Increased age, preoperative neurologic complications, cardiogenic shock at the time of operation, shorter duration of the illness, insidious illness before the operation, and mitral valve endocarditis were the predominant risk factors for late mortality. The probability of freedom from reoperation (operative mortality included) was 73.3% +/- 4.2% at 8 years; risk factors were younger age and aortic valve endocarditis. The rate of prosthetic valve endocarditis was 7%. No significant risk factor was found. CONCLUSIONS: Increased age, insidious illness, and hemodynamic failure are the main risk factors for operative mortality. Long-term survival is good except for patients with preoperative neurologic complications and mitral valve endocarditis.

Adult↗

Nonpenetrating clips for coronary anastomosis.

BACKGROUND: A nonsuture clip technique (nonpenetrating titanium clips applied to everted tissue edges at high compressive forces) was used to perform coronary anastomoses in a clinical setting. METHODS: Clipped coronary anastomoses were performed in 10 patients. The anastomoses incorporated the left internal mammary artery to the left anterior descending artery (n = 1) and the saphenous vein to the right coronary artery (n = 5), the posterior descending artery (n = 2), the diagonal artery (n = 2), and one vein-to-vein proximal anastomosis (n = 1). RESULTS: The mean duration for completion of the anastomoses was 15 minutes (range, 7 to 20 minutes). This time was reduced from 20 minutes at the beginning of the clinical experience to 7 minutes for the last 3 patients. No technical complication was related to clip application and all patients had uneventful outcomes. Three anastomoses studied by coronary angiography were patent without stenosis. CONCLUSION: The clipped anastomotic technique has a rapid learning curve, the same safety as suture methods, and the potential for facilitating endoscopic vascular reconstructions.

Anastomosis, Surgical↗

Thoracoscopic internal mammary artery harvesting: technical considerations.

BACKGROUND: Technical details of thoracoscopic harvesting of the internal mammary artery (IMA) are reported. This procedure allows a complete dissection of the left IMA from its origin at the subclavian artery to the sixth intercostal branches with transection of all collateral branches. METHODS: Between September 1995 and September 1996, thoracoscopic harvesting of the left IMA was performed on 32 patients who had undergone a minimally invasive coronary artery bypass grafting procedure. RESULTS: There were no conversions to a standard approach because of an injury to the graft and no reoperations for bleeding. The mean duration of the IMA harvesting procedure was 58.7 minutes (range, 20 to 130 minutes). CONCLUSIONS: This procedure enlarges the field of minimally invasive coronary artery bypass grafting techniques. The thoracoscopic harvest of the full length of the IMA allows the procedure to more closely replicate the open approach.

Endoscopy↗

The Concerted Action 'Heart' European registry on clinical application of mechanical circulatory support systems: bridge to transplant. The Registry Scientific Committee.

OBJECTIVE: The goal of this paper is to identify in the field of mechanical support as bridge to transplant, by statistical analysis, variables influencing survival during support (transplanted patients) and the overall survival (discharged after transplant). METHODS: Clinical factors are analysed in 258 patients in the period 1986-1993. All variables were analyzed by a univariate and multivariate analysis. RESULTS: The indications for mechanically circulatory support were hemodynamic deterioration before transplantation in 177 (69%), post acute myocardial infarction in 40 (15%), postcardiotomy cardiogenic shock in 20 (8%), graft failure in 12 (5%) and cardiac rejection 9 (3%). The devices implanted have been: pneumatic VAD in 145 cases (56%), electromechanical LVAS in 15 cases (6%), TAH in 78 cases (30%) and centrifugal pumps in 20 cases (8%). The patients were supported for period ranging from 2 h to 623 days (mean 18.3 days +/- 43.2). The type of support was: LVAD 50 cases (20%), RVAD 3 cases (1%), BVAD 127 cases (49%), and TAH 78 cases (30%). Bleeding occurred in 84 patients (32.5%), infections in 83 patients (32.1%); 21 embolic complications were reported in 16 patients (6%). Renal failure occurred in 64 cases (25%) requiring dialysis in 33 (13%); respiratory failure in 47 cases (18%); neurological impairment was noted in 22 patients (9%). One hundred-sixty patients were transplanted (62%) and 104 ultimately discharged (40% out of total 258 patients and 65% out of 160 transplanted patients). Among postoperative parameters, renal failure, TAH, neurological impairment and infection shown statistical power. Some pre- and post-operative variables were identified as independent risk factors for overall mortality: age, indication for graft failure, all indications different from cardiomyopathy, neurological impairment, renal insufficiency, infection, bleeding and any type of support different from LVAD. The improvement in the success rate in the last 2 years is statistically significant (P = 0.0282) considering both the percentage of transplanted patients and of discharged patients. CONCLUSIONS: The results are encouraging if mechanical support is performed in patients with deterioration while awaiting transplant, when LVAD is feasible and effective, when an ideal timing of transplant during support period is identified.

Adolescent↗

Video-assisted coronary bypass surgery: clinical results.

OBJECTIVE: Clinical experience with a video-assisted coronary artery bypass grafting procedure using the internal mammary artery is reported. The technique consists of a videoscopic harvesting of the left internal mammary artery (LIMA) to revascularise the left anterior descending artery (LAD) through a 4-cm left thoracotomy. METHODS: Between September 1995 and July 1996, we performed this procedure on 30 patients (29 males, 1 female; aged 38-71) with an isolated proximal LAD stenosis (n = 21) or occlusion (n = 9). All patients were symptomatic despite appropriate medication. A history of non-transmural myocardial infarction with myocardial viability was found in nine patients. Fourteen patients had a restenosis after previous percutaneous transluminal coronary angioplasty (PTCA). Mean left ventricular ejection fraction was 0.61 (< 0.3 in two patients). The LAD LIMA anastomosis was performed on the beating heart without cardiopulmonary bypass (CPB) in 26 patients. Femoral-femoral CPB was used in three patients because of unstable angina (n = 1) and intramyocardial LAD (n = 2). Conversion to sternotomy and standard CPB was necessary in one patient for extensive endarterectomy of the LAD. RESULTS: There were no operative complications and no reoperations for haemorrhage. Pulmonary infection was observed in one patient and wound infection in one patient. Patients who underwent the complete procedure on the beating heart without conversion or CPB were ready for discharge on the 5th postoperative day (36 h-13 days). Control coronary angiography was performed in 20 patients. In all cases, the graft was patent. In 17 cases, there was a patent graft with no evidence of anastomotic stenosis. An occlusion of the distal segment of the LAD with a retrograde perfusion of the proximal segment and septal branches by the LIMA was found in one case. This patient was symptom-free and the stress test was negative. An anastomotic stenosis was noted in two patients and was treated by angioplasty (n = 1) or conventional surgery (n = 1). CONCLUSION: In conclusion, the efficiency of this minimally invasive approach should be prospectively compared with similar revascularisation with PTCA or surgical approaches using sternotomy with or without CPB.

Angioplasty, Balloon, Coronary↗

[CardioWest, a complete artificial heart, the French experience].

The development of implantable electric assist systems for the left ventricle cannot be used in all patients. Approximately one-third of them who could benefit from circulatory support while waiting for transplantation also require a supporting system for the right ventricle. In addition, the small number of available donor organs means that only those patients with the best prognosis can be transplanted. From January 1993 to December 1995, 36 patients (33 men, 3 women) mean age 41 years (range 19-60) were treated with a total artificial heart system, CardioWest at the La Pitié Hospital in Paris and at the Laennec Hospital in Nantes, France. Heart assist lasted 1 to 138 days (mean 31 days). Indications were terminal heart failure due to dilated (n = 21) or ischemic (n = 11) cardiomyopathy and 4 high-risk indications (chronic rejection, primary failure, hereditary heart disease, polyvalve disease). Twenty-two of these patients (61.1%) were transplanted. By using strict selection criteria, the total artificial heart CardioWest was able to maintain satisfactory hemodynamic conditions until transplantation without compromising the small number of donor organs available. The total artificial heart is the best system available for total circulatory support in case of dual ventricular failure. The risk of infection is low and the rate of thrombo-embolic events is reduced when care is taken in controlling coagulation, allowing long-term support. Independently of the experience of the different teams, CardioWest is the only device currently available allowing total heart support; its use is justified in particular when other assist devices are unsuccessful.

Adult↗

[Video-assisted coronary artery bypass].

The benefits of the internal mammary artery (IMA), as a graft, particularly for the left anterior descending (LAD) coronary artery disease, have been demonstrated. Coronary artery bypass grafting (CABG) without cardiopulmonary bypass (CPB) is now an accepted technique of myocardial revascularization. Thoracoscopy and a minimal thoracotomy have been applied to cardiac surgery, however its use has not been well defined; in our approach, we harvested the left IMA thoracoscopically. Following this the left IMA-LAD coronary artery anastomosis was fashioned, by means of a left small anterior thoracotomy on the beating heart without CPB. A double lumen endotracheal tube was used so the lung could be collapsed. Three left lateral chest ports of 1 cm were made, and the thoracoscope was placed through the initial port, permitting inspection of the thorax. The other ports were used for IMA dissection, using endoscopic instruments (electrocautery, grasping, forceps,...), the side branches were controlled by either cautery or endoscopic clips. When it was possible, the anterior port was extended doing a small left anterior thoracotomy, the pericardium was exposed, the IMA was divided and exteriorized through the thoracotomy. After coronary artery control, the bypass graft was carried out on the beating heart without CPB, in 26 patients. From september 1995 to july 1996, we have operated on 30 patients using this technique. We believe that with increasing operator experience, this minimally invasive approach will have a major impact on the management of the coronary artery disease patients, with a faster recovery, shorter hospitalization, and certainly less cost.

Adult↗

Position-related factors in mitral and tricuspid bioprostheses degenerative changes.

We report clinicopathological findings in 15 patients in whom the same bioprosthesis (BP) had been implanted simultaneously in both mitral and tricuspid positions. The aim of the study was to investigate whether position-related factors played an important role in BP degeneration. There were 14 women and 1 man with a mean age of 34 +/- 11 years. The indications for the initial operation were rheumatic in 14 cases and endocarditis in one patient. The mean interval before reoperation was 7.5 +/- 3.3 years. Predominant cause of reoperation was: structural deterioration of both mitral and tricuspid BPs (6), mitral regurgitation (5), tricuspid BP dysfunction (1), para-aortic leak (1), mitro-aortic thrombi (1). Calcific deposits were the principal cause of early deterioration of mitral BPs and the major cause of late tricuspid BPs dysfunction. This lesion was predominantly related to local factors. Cuspal tears were the principal cause of late (> 9 yrs) mitral BP failure and most probably related to mechanical stress. Extensive fibrosis affected only tricuspid bioprostheses. In 7 patients more extensive degenerative changes occurred in bioprostheses in the mitral rather than the tricuspid position (Group I). However, in the remaining eight the magnitude of the changes was very similar in the two positions (Group II). The interval before reoperation was significantly longer in patients of Group II (9.8 yrs, range 5-13) than patients in Group I (4.9 yrs, range 3-6), (p < 0.01). We concluded that position-related factors exert a major role in bioprosthetic failure. These factors are more deleterious in the mitral position than in the tricuspid position.

Adolescent↗

International experience with the CardioWest total artificial heart as a bridge to heart transplantation.

As the number of potential heart donors remains constant and the number of potential recipients continuous to increase, the need for circulatory devices to bridge patients becomes more important. The CardioWest total artificial heart (TAH) is a pneumatic, implantable system that totally replaces the failing ventricles. It has been utilized worldwide as a bridge to heart transplantation in 79 patients. There were 73 males and six females who received the TAH. Currently three patients remain on the device waiting for transplantation. A total of 55 patients (70%) were transplanted of which 50 survived (91% of patients transplanted) and were discharged home. Idiopathic/dilated cardiomyopathy was the most common etiology followed by ischemic cardiomyopathy. The mean duration of implant was 34 days (range 0-186 days) and the mean age of the group was 45 years (range 16-62 years). Twenty-one patients died while on the device. Multiple organ failure was the major cause of death. There were a total of 255 complications in this group that included reoperation, bleeding, hepatic failure, renal failure, respiratory failure, neurologic events, thromboembolic events, infections, device malfunction, and fit complications. This represented a mean complication rate of three events per patient. The survival rate for the CardioWest TAH of 91% of the patients who reached transplantation is an improvement over that of the Symbion registry (55% of those transplanted) probably as a result of a better patient selection and better control of the coagulation system. These results are also comparable to those survival results obtained with other biventricular and left ventricular assist devices currently available.

Adolescent↗

Physiology of univentricular versus biventricular support.

Right ventricular failure unresponsive to pharmacologic treatment occurs in approximately 20% to 30% of patients supported with a left ventricular assist device (LVAD). The effect of the assistance on right ventricular function is highly controversial. Increased venous return produced by an LVAD can affect right ventricular function by increasing preload. On the other hand, an LVAD can improve the filling of the right ventricle by unloading the left ventricle, reducing its chamber size and shifting the septum back to the left. Right ventricular function is highly afterload dependent, the ventricular function depending on the pulmonary vascular resistance. With a normal pulmonary vascular bed, the LVAD can improve right ventricular function by reducing right ventricular afterload. If there is a fixed high pulmonary pressure, however, the LVAD can increase right ventricular afterload and volume. We conclude that the right ventricle is dispensable if the pulmonary vascular bed is normal.

Cardiac Output, Low↗

Heart transplant for the failing ischaemic ventricle.

Clinical application of heart transplantation goes beyond 28 years experience. Ischaemic heart diseases remain, with idiopathic cardiomyopathies, the main indications for cardiac transplant. A combination of haemodynamic, contractile and viability measurements may be useful to choose between transplant and coronary revascularization for the failing ischaemic ventricle. Advances in the detection of early rejection, improved organ preservation procedures, and the introduction of new immunosuppressive therapy protocols have produced dramatic results in heart transplantation. Late graft atherosclerosis remains a serious threat despite retransplantation and, in some cases, mechanical circulatory support.

Contraindications↗