Search PubMed⌕ Search

Biomedical subjects

A Pavie

Publications and source records attributed to A Pavie.

At least 19 recordsLinked to original sources

[What's new in mechanical circulatory assistance: from clinical indications to material].

Over the years, mechanical circulatoryassistance has progressively improved with the evolution of the clinical indications and the introduction of new devices. The management of situations of extreme emergency, cardiac arrest, acute myocardial infarction with cardiogenic shock, drug overdose, acute myocarditis, postoperative cardiac failure and post-transplantation right ventricular failure, may be undertaken with relatively simple systems such as the ECMO, in the catheter laboratory or at the bedside in the intensive care unit. These systems enable stabilisation of the circulatory problems in order to pass a difficult situation and then withdraw the assistance when myocardial function has been restored. When this is not possible and there is no contra-indication to cardiac transplantation, patients may benefit from more complex assistance devices as a bridge to transplantation. Many continuous flow pumps have been introduced recently. These small mono, left ventricular, assist devices provide improved patient comfort and suggest wider indications of long duration assist devices.

Heart Failure↗

[Treatment of obstructive aortic atheroma in homozygotic familial hypercholesterolemia].

The object of this report is to describe the surgical treatment of a rare clinical form of homozygotic familial hypercholesterolaemia (HFH) associating valvular and supravalvular stenosis with coronary ostial stenosis. Three patients, two male and one female, aged 15, 23 and 41 respectively, suffering from HFH diagnosed in early childhood, presented with obstacles to left ventricular ejection and myocardial ischaemia due to coronary ostial stenosis. Surgery consisted of corrections in a single procedure of all abnormalities by aortic valve replacement, ascending aortic replacement and widening of the coronary artery ostia which were reimplanted on the aortic tube. The postoperative course of all three patients was favourable. Postoperative echocardiography showed the normal position of the valvular prosthesis, normalisation of the left ventricular ejection fraction with no significant residual obstruction. Angioscan of the coronary arteries showed a good result of coronary ostial widening. The authors conclude that HFH is a rare condition and that disease of the ascending aorta is common in this variety with involvement of the aortic valve, the ascending aorta and the coronary ostia. The surgical procedure described by the authors allows correction of all the abnormalities with the hope of a good long-term result.

Adolescent↗

[Pseudo-aneurysms of the ascending aorta in patients previously operated for acute aortic dissection].

Pseudo-aneurysms of the ascending aorta are a rare but serious complication of surgery for acute dissection of the aorta. The diagnostic methods and surgical technique have changed in recent years. The authors report their experience over a period of 20 years. From January 1981 to December 2001, 21 patients underwent reoperation for pseudo-aneurysms of the ascending aorta. The average age was 54.2 +/- 3 years. Diagnosis is no longer based on aortography but on transthoracic or oesophageal multiplane echocardiography, thoracic spiral computed tomography or magnetic resonance imaging. Four patients presented with a recent history of severe pulmonary oedema. The risk associated with reopening the sternum is avoided by current operative techniques. The authors have chosen anterograde perfusion of the cervical arteries by direct canulation for cerebral protection. The operative mortality at one month is high (30%). All patients who had pulmonary oedema or cardiogenic shock in the immediate preoperative period died. There were no neurological complications. Twelve patients survived and one has to undergo a further operation for recurrence of the pseudo-aneurysm. The authors conclude that patients operated for dissection of the aorta must be followed up. It is important to resect as much as possible of the pathological aorta during the initial operation to avoid the risk of pseudo-aneurysm formation, at least in the proximal segment of the ascending aorta.

Aortic Dissection↗

[Post-myocardial infarction cardiogenic shock and circulatory assistance].

Post-myocardial infarction cardiogenic shock still carries a very poor prognosis despite the rapid recourse to effective methods of myocardial revascularisation. Circulatory assistance devices allow restoration of adequate haemodynamics with limitation of myocardial work. In the most severe cases, implantation of intra-thoracic devices is associated with a 70% survival rate in the latest series, providing they are used early. However, in many cases, the essential problem is to stabilise the patient's haemodynamic status, sometimes even before myocardial revascularisation. In these situations, implantation of a peripheral femoro-femoral extra corporeal circulation (ECMO: extra corporeal membrane oxygenation) re-establishes an appropriate cardiac output andprovides time to transfer the patient, to perform coronary revascularisation or to assess neurological status, before deciding on the indications for more complicated assist systems. This "bridge to bridge" concept avoids the risk of implanting complicated assist devices in cerebrally dead patients or in those with multi-organ failure beyond treatment. Conversely, it gives some patients with apparent contraindications to complicated assist systems or who are unable to benefit from these systems for geographical reasons, a chance to survive. In early cardiogenic shock, the ECMO which has a low rate of complications, could safely promote myocardial recovery.

Assisted Circulation↗

Bridge to transplantation with the Jarvik-7 (CardioWest) total artificial heart: a single-center 15-year experience.

BACKGROUND: At our institution, the total artificial heart (TAH) Jarvik-7 (CardioWest) has been used since 1986 as a bridge to transplantation for the most severely ill patients with terminal congestive heart failure. METHODS: Between 1986 and 2001, 127 patients (108 males, mean age 38 +/- 13) were bridged to transplantation with the Jarvik-7 TAH. All were in terminal biventricular failure despite high-dose inotropic support. Nine patients had a body surface area (BSA) of <1.6 m(2). In Group I patients (78%), the etiology of cardiac failure was dilated cardiomyopathy, either idiopathic (n = 60) or ischemic (n = 38). The other 29 patients (Group II) had disease of miscellaneous origin. We analyzed our experience with regard to 3 time periods: 1986 to 1992 (n = 63); 1993 to 1997 (n = 36); and 1998 to 2001 (n = 33). RESULTS: Although Group II patients represented 30% of indications before 1992, they comprised only 15% during the 2 subsequent periods. Duration of support for transplant patients increased dramatically after 1997, reaching 2 months for the most recent period (5 to 271 days). In Group I, the percentage of transplanted patients increased from 43% before 1993 to 55% between 1993 and 1997, and reached 74% thereafter. The major cause of death was multiorgan failure (67%). The clinical thromboembolic event rate was particularly low with no instance of cerebrovascular accident and 2 transient ischemic attacks. Total bleeding complication rate was 26%, including 2 deaths related to intractable hemorrhage and 2 others related to atrial tamponade. The cumulative experience was 3,606 total implant days with only 1 instance of mechanical dysfunction. CONCLUSIONS: TAH is a safe and efficient bridge for patients with terminal congestive heart failure awaiting cardiac transplantation.

Adolescent↗

[Totally implantable completely electric artificial heart: "AbioCor"].

The fully implantable complete electric artificial heart "AbioCor" is the ultimate stage in the 3rd generation assistance systems. It has been authorized for clinical use since last year by the Food and Drug Administration (F.D.A.). It is an electrohydraulic heart developed by Abiomed. It consists of implanted internal components: the cardiac pump, an internal lithium battery, a controller and an internal coil allowing electrical energy transfer across the skin, and external components: an external coil and external batteries. The one-piece heart includes two ventricular chambers: right and left. All of the surfaces in contact with blood as well as the four three-leaved valves are made of polyurethane. An electro-hydraulic energy converter powers the ventricles. A stroke volume of 60 to 65 ml allows an output of between 4 and 10 L.min-1. Between 2 July 2002 and 4 November 2002, seven males, aged between 51 and 70 years, underwent implantation. They were suffering from ischaemic cardiopathy (6 cases) or idiopathic dilated cardiopathy (1 case). Among the late complications, 3 severe embolic cerebrovascular accidents occurred. Four late deaths occurred.

Aged↗

Cardiac surgery in patients receiving long term hemodialysis. Short and long term results.

AIM: Cardiac surgery carries a high risk in hemodialysis patients and has been questioned for its results; the purpose of this study is to focus on the short and long term results in our institution. METHODS: We retrospectively analyzed the data from 124 hemodialysis patients who underwent cardiac surgery in our unit between January 1980 and December 1998; 14.5% were diabetic; 46% had isolated coronary artery disease (group 1); 29.8% had valvular disease alone (group 2); 14.5% valve and coronary disease (group 3) and 9.6% miscellaneous disease at highest risk (group 4). We analyzed the relationship between several variables (age, sex, hypertension, diabetes, previous myocardial infarction, type of disease, preoperative ejection fraction) and operative mortality (30 days) and late survival. RESULTS: The overall operative mortality was 16.9%. The only risk factor was the type of cardiac disease: operative mortality was higher in groups 3 and 4 combined than in groups 1 and 2 combined (30% versus 12.7%, p=0.07). Ninety-nine patients were followed until January 2002. Late survival rate was 46.6+/-5% at 6 years for all patients, it was significantly better in groups 1 and 2 combined than in groups 3 and 4 combined. The only risk factor for late mortality was arterial hypertension. Fifty-seven patients are still alive, 46 in groups 1 and 2, 11 in groups 3 and 4. Progression of coronary lesions occurred in 6 patients and valvular lesions in 3 patients. The remainder are doing well. CONCLUSION: Cardiac surgery seems to be justified by the severity of the lesions. Its actual results can perhaps, be improved by earlier detection of cardiac disease and better prevention of myocardial hypertrophy and cardiac calcifications.

Age Factors↗

[Fulminating myocarditis: myocardial recovery after circulatory assistance].

The clinical expression of acute myocarditis is variable from paucisymptomatic to fulminating forms which are usually lethal within days. The latter presentation takes the form of very acute cardiac failure. During this phase, the severity of myocardial dysfunction may be such that death ensues. However, if the patient survives, paradoxically, these forms have a better long-term prognosis with complete recovery of myocardial function being possible after the acute phase. The authors report a typical case of fulminating myocarditis with electromechanical dissociation, which recovered completely after a period of circulatory assistance. This case illustrates the rapidity of deterioration of the haemodynamic status and the importance of organ dysfunction despite early management. In a review of the literature, the authors found about 150 reported cases of acute myocarditis treated with circulatory assistance. In the best series, about half the patients were weaned off the circulatory assistance without having to undergo cardiac transplantation. However, the potential recovery of myocardial function is difficult to predict.

Adult↗

Mechanical circulatory support for advanced heart failure: effect of patient selection on outcome.

BACKGROUND: Use of wearable left ventricular assist systems (LVAS) in the treatment of advanced heart failure has steadily increased since 1993, when these devices became generally available in Europe. The aim of this study was to identify in an unselected cohort of LVAS recipients those aspects of patient selection that have an impact on postimplant survival. METHODS AND RESULTS: Data were obtained from the Novacor European Registry. Between 1993 and 1999, 464 patients were implanted with the Novacor LVAS. The majority had idiopathic (60%) or ischemic (27%) cardiomyopathy; the median age at implant was 49 (16 to 75) years. The median support time was 100 days (4.1 years maximum). Forty-nine percent of the recipients were discharged from the hospital on LVAS; they spent 75% of their time out of the hospital. For a subset of 366 recipients, for whom a complete set of data was available, multivariate analysis revealed that the following preimplant conditions were independent risk factors for survival after LVAS implantation: respiratory failure associated with septicemia (odds ratio 11.2), right heart failure (odds ratio 3.2), age >65 years (odds ratio 3.01), acute postcardiotomy (odds ratio 1.8), and acute infarction (odds ratio 1.7). For patients without any of these factors, the 1-year survival after LVAS implantation including the posttransplantation period was 60%; for the combined group with at least 1 risk factor, it was 24%. CONCLUSIONS: Careful selection, specifically implantation before patients become moribund, and improvement of management may result in improved outcomes of LVAS treatment for advanced heart failure.

Adolescent↗

Expanded polytetrafluoroethylene membranes to wrap surfaces of circulatory support devices in patients undergoing bridge to heart transplantation.

OBJECTIVE: Because of a lack of donor hearts, an increasing number of patients with heart failure must now undergo bridge to cardiac transplantation with a mechanical circulatory support device. Moreover, support periods have become longer. As a result, pericardial adhesions may develop while the support device is implanted, increasing the risk of injury at resternotomy and bleeding after transplantation. Use of expanded polytetrafluoroethylene (ePTFE) pericardial substitutes (membranes) may prevent such adhesions. PATIENTS AND METHODS: From January 1997 to December 1999, ePTFE membranes were used in 23 patients to wrap portions of an implanted left ventricular assist device (LVAD) or total artificial heart (TAH). Any complications during mechanical support or at cardiac transplantation were recorded. Six ePTFE membranes removed at transplantation were studied histologically. RESULTS AND CONCLUSIONS: At resternotomy for transplantation, the plane of dissection between tissues, ePTFE membranes, and surfaces of the mechanical support device were easily discerned. No adhesions were observed between tissues and membranes. There were no injuries during resternotomy and no patient had to undergo reoperation because of bleeding. One patient given a TAH had an infection during circulatory support that was controlled by antibiotic therapy. In another patient, clots developed between the device and an ePTFE membrane; these were removed successfully. Histologic studies of removed ePTFE membranes showed no infiltration of the membranes interstices by collagen or cellular components. Use of ePTFE membranes in patients undergoing bridge to transplantation with either an LVAD or a TAH limited adhesions between tissues and device surfaces without increasing the risk of infection.

Adolescent↗

[Endomyocardial fibrosis in Behcet's disease: a case report of a pseudo-tumoral form].

Endomyocardial fibrosis is very rare in Behcet's disease. The authors report the case of a 28 year old patient with Behcet's disease complicated by a pseudo-tumoral right ventricular formation on echocardiography. This misleading appearance suggested the diagnosis of cardiac thrombus or tumour and led to a surgical approach which revealed a fibrous moderator band suggesting endomyocardial fibrosis, confirmed by antomopathological analysis. Besides the originality of this case and the unusual pseudo-tumoral presentation, the authors underline the difficulties of establishing the diagnosis, despite the advances of medical imaging. The pseudo-tumoral intra-cardiac lesion in a suggestive clinical context (Behcet's disease) should raise suspicion of the diagnosis of endomyocardial fibrosis.

Adult↗

A multicenter initial clinical experience with right heart support and beating heart coronary surgery.

BACKGROUND: During coronary surgery without CPB, exposure of posterior vessel via sternotomy can cause deterioration of cardiac hemodynamics requiring inotrope drugs support. Recent animal experiments demonstrate hemodynamic benefit of right heart support (RHS) with the AMED system. The purpose of this study was to evaluate the hemodynamic effects during cardiac manipulation to expose the posterior coronary arteries, and determine the effect of RHS in restoring hemodynamics, increasing anastomotic exposure and reducing inotropic requirements. MATERIAL AND METHODS: From July 28 to December 29, 32 patients (25 men/7 women), mean age of 63.4 (+/- 6.2 years, ages: 49-78) received coronary revascularization with the A-Med RHS device. They were divided into two groups of 16 patients, A and B. Group A patients had at least one circumflex branch bypassed. The anterior wall was systematically bypassed off-pump without RHS. The right coronary artery (RCA) and the obtuse coronary artery (OM) were completed utilizing RHS. In group B patients, all vessels including anterior vessels were bypassed with the RHS. Mean arterial pressure (MAP), mean pulmonary arterial pressure (PAP), cardiac output (CO) and the average pump flow (APF) were recorded during the OM and RCA bypass for group A, and for group B LAD data was also recorded. RESULTS: Elective beating heart coronary artery bypass graft (CABG) was successfully accomplished in 32 patients with RHS. Data measurements recorded in Group A showed the improved hemodynamic recovery for OM and RCA bypass with RHS. The MAP increased from 44 to 68 mmHg (OM) and from 63 to 81 mmHg (RCA); the CO from 2.1 to 4.4 L/min (OM) and from 3.3 to 4.7 L/min (RCA). In group B, the data recorded showed the stability of the MAP in all vessels bypassed (LAD, OM and RCA). No device-related patient incidents occurred. All 32 patients were discharged to their homes. CONCLUSIONS: The AMED system, as RHS support, facilitated coronary bypass without CPB to posterior vessels, restoring hemodynamics, providing better exposure to anastomotic sites and apparently reducing inotropes need. Prospective randomize trials are necessary to confirm this initial experience.

Aged↗