On-line diode laser based time-resolved fluorescence detection of labelled oligonucleotides in capillary gel electrophoresis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A Paulus.
Explore the source record for details and available documents.
There is in Europe growing awareness that the delivery of integrated care is required to meet the demands of an increasing number of patients with multiple problems. It is also clear that the provision of integrated care is difficult to achieve. As yet, the debate about the circumstances enabling or hindering provision is not settled. The objective of this article is to generate more knowledge on this issue. It is often assumed that the feasibility of integrated care provision is caused by characteristics of the legislation, the financing system and other aspects of the institutional context. Here it is argued that these characteristics are relevant but not decisive. Based on empirical evidence from the Dutch case a rival viewpoint is presented, suggesting that it is the commitment of the actors involved, their support, and the way developments are being managed, that make the difference. Following presentation of the evidence, the implications of the findings for integrated care policy are discussed.
DNA digest analysis with polymer-filled capillaries in capillary electrophoresis is described. The samples analyzed consisted of commercially available standards including a 100 base pair ladder with repeating units up to 2000 base pairs. Three DNA digests covered the most common small fragment ranges: up to 600 base pairs, up to 1500 base pairs and from 100 to 2500 base pairs. All samples were separated by traditional slab gel electrophoresis at various agarose concentrations and by automated capillary electrophoresis. The capillary electrophoretic separations were achieved with noncross-linked polyacrylamide from 6% monomer solutions. The acrylamide was polymerized inside the capillary, which was coated with a methacryloxysilane to insure binding of the polyacrylamide to the capillary wall. With 6% columns, excellent separations were observed up to 600 base pairs with base line resolution for fragments differing in less than 10 base pairs. Resolution power for fragments between 600 and 2200 decreased to about 300 base pairs. Compared to slab gels, capillary electrophoresis achieved better resolution in the low fragment range, whereas with the reported column composition, slab gels were superior above 600 base pairs. Fast access to the analysis of a specific sample, automation, and a larger dynamic range for sample load are further benefits of a DNA digest analysis by capillary electrophoresis.
The origin of both coronary arteries from the pulmonary artery is a rare cardiac malformation. We report a baby who presented with an echocardiographically diagnosed perimembranous ventricular septal defect and normal left ventricular (LV) function. Later on the boy developed failure to thrive and increasing tachypnea. At the age of 5 weeks the ECG showed that LV strain and echocardiographic LV function had worsened (FS 18%). Echocardiography and heart catheterization showed that all coronary arteries originated from the pulmonary trunk. Intraoperative inspection revealed a single ostium for the right and left coronary artery in the nonfacing sinus of the pulmonary trunk. A tube was constructed connecting the coronary artery to the ascending aorta. Coronary perfusion was sufficient and the sinus rhythm was restored. However, in the early postoperative period there was a sudden deterioration of cardiac output followed by cardiac arrest. Reanimation was not successful.