Search PubMed⌕ Search

Biomedical subjects

A P Yoganathan

Publications and source records attributed to A P Yoganathan.

At least 19 recordsLinked to original sources

In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging.

BACKGROUND: The total cavopulmonary connection (TCPC) design continues to be refined on the basis of flow analysis at the connection site. These refinements are of importance for myocardial energy conservation in the univentricular supported circulation. In vivo magnetic resonance phase contrast imaging provides semiquantitative flow visualization information. The purpose of this study was to understand the in vivo TCPC flow characteristics obtained by magnetic resonance phase contrast imaging and compare the results with our previous in vitro TCPC flow experiments in an effort to further refine TCPC surgical design. METHODS: Twelve patients with TCPC underwent sedated three-dimensional, multislice magnetic resonance phase contrast imaging. Seven patients had intraatrial lateral tunnel TCPC and 5 had extracardiac TCPC. RESULTS: In all patients in both groups a disordered flow pattern was observed in the inferior caval portion of the TCPC. Flow at the TCPC site appeared to be determined by connection geometry, being streamlined at the superior vena cava-pulmonary junction when the superior vena cava was offset and flared toward the left pulmonary artery. Without caval offset, intense swirling and dominance of superior vena caval flow was observed. In TCPC with bilateral superior vena cavae, the flow patterns observed included secondary vortices, a central stagnation point, and influx of the superior vena cava flow into the inferior caval conduit. A comparative analysis of in vivo flow and our previous in vitro flow data from glass model prototypes of TCPC demonstrated significant similarities in flow disturbances. Three-dimensional magnetic resonance phase contrast imaging in multiple coronal planes enabled a comprehensive semiquantitative flow analysis. The data are presented in traditional instantaneous images and in animated format for interactive display of the flow dynamics. CONCLUSIONS: Flow in the inferior caval portion of the TCPC is disordered, and the TCPC geometry determines flow characteristics.

Adolescent↗

Harvested porcine mitral xenograft fixation: impact on fluid dynamic performance.

BACKGROUND AND AIM OF THE STUDY: Recent developments suggest that stentless bioprosthetic mitral valve heterografts should be considered in order to optimize valve hydrodynamics. The fixation process alters the mechanical properties of tissue. This study investigates the changes in mitral valve morphology and hemodynamic performance following fixation. METHODS: Porcine mitral valves were excised and attached to a physiological annular ring. Mitral valve function was studied in vitro with a rigid transparent left heart model, allowing transverse and sagittal views. Initial experiments were performed with fresh valves under physiological conditions. Three different papillary muscle positions were used, and each was recorded. After glutaraldehyde fixation, genipin fixation, and cryopreservation, the valves were re-studied while maintaining cardiac output. Performance characteristics before and after fixation were obtained from hydrodynamic pressure and flow data, high-speed video camera, digital video, Doppler ultrasound, and three-dimensional papillary muscle force measurements. Morphology changes were detected by detailed anatomic measurements of the valves before and after fixation. RESULTS: Valve length was reduced by 18.5% after fixation with genipin (p <0.001), but not with glutaraldehyde. Cryopreserved valves showed no statistically significant changes in morphology or hydrodynamic performance after preservation. The forward flow opening area was reduced by 12.2% (p <0.001) after glutaraldehyde fixation, and by 32.3% (p = 0.004) after genipin fixation. Thus, maximal forward flow velocity was increased by 33.3% (p = 0.008) after glutaraldehyde fixation and by 52.8% (p = 0.001) after genipin fixation. The flow acceleration was consistent with a funnel shape of the fixed valves causing important flow contraction beyond the orifice (vena contracta). The papillary muscle force increased with apically posterior papillary muscle displacement by 20.4% (p = 0.001) and 101.5% (p <0.001) after glutaraldehyde and genipin fixation, respectively, and total regurgitant volume was increased by 91.6% (p <0.001) and 117.3% (p <0.001), respectively. The work required by the heart simulator to maintain a constant cardiac output at constant vascular resistance increased by 24.2% (p = 0.003) and 34.2% (p = 0.004) after glutaraldehyde and genipin fixation, respectively. CONCLUSION: The present study shows that chemical fixation of porcine mitral valves adversely affects the hemodynamics of the valves, increasing overall workload. The effects were more severe after fixation with genipin than with glutaraldehyde. This suggests the need to explore other fixation agents to optimize valvular cardiac function. Cryopreservation had no detrimental effects on valvular hemodynamic performance.

Animals↗

The sensitivity of indicators of thrombosis initiation to a bileaflet prosthesis leakage stimulus.

BACKGROUND AND AIM OF THE STUDY: The recent clinical history and experimental studies of the Medtronic Parallel (MP) valve suggest that bileaflet valve leakage flow is a primary initiator of thrombosis. These studies investigated the effects of physiologic leakage flow through a MP valve on various markers of blood damage. METHODS: A centrifugal pump was used to drive whole, human blood anticoagulated with PPACK through a circuit containing a MP 27 mm valve in the closed position (experimental runs) or a MP 27 mm valve in the open position (control runs). Samples were taken at set time intervals after the start of the pump. These samples were analyzed by cell counting, flow cytometry, and ELISA. RESULTS: Cell counts remained relatively constant in both the experimental and control runs. Increases in plasma hemoglobin concentration and the percentage of glycophorin A-positive fragments in the cell population were not significant in either the experimental or the control runs. Plasma platelet factor 4 activity and the percentage of the CD41-positive population which was positive for annexin V increased significantly (p <0.05) in the experimental runs compared with the control runs. CONCLUSION: The results indicate that bileaflet valve leakage flow causes significant platelet disruption, that erythrocytes are more resistant to disruption by leakage flow than platelets and granulocytes, and that annexin V binding to platelets and plasma platelet factor 4 activity are more sensitive markers of leakage induced blood damage than plasma hemoglobin concentration.

Annexin A5↗

A comparison of the hinge and near-hinge flow fields of the St Jude medical hemodynamic plus and regent bileaflet mechanical heart valves.

OBJECTIVE: The most widely implanted prosthetic valves are the mechanical bileaflets, most of which have good forward flow hemodynamics. However, recent clinical experiences illustrate the importance of understanding the flow structures generated within the hinge. The purpose of this study was to evaluate the hinge-flow dynamics of two new variations of a 17-mm St Jude Medical bileaflet valve: the Hemodynamic Plus and the Regent (St Jude Medical, Inc, St Paul, Minn). METHODS: Clinical quality reproductions of the valves were manufactured with clear housings. Laser Doppler velocimetry velocity and turbulent shear stress measurements were conducted within the hinge and thumbnail regions of the valves. RESULTS: In the 17-mm Hemodynamic Plus hinge, a rotating flow structure developed in the inflow pocket during forward flow. During systole, velocities through the hinge pocket reached 0.70 m/s, and the turbulent shear stress reached 1000 dynes/cm(2). In the thumbnail, forward flow velocities ranged from 1.4 m/s to 1.7 m/s. In the 17-mm Regent hinge, a rotating flow structure partially developed in the inflow pocket during forward flow. During systole, velocities through the hinge pocket reached 0.75 m/s, and the turbulent shear stress reached 1300 dynes/cm(2). In the thumbnail, forward flow velocities ranged from 1.0 m/s to 1.3 m/s. CONCLUSIONS: The active leaflet motion through the St Jude Medical hinge creates a washout pattern that restricts the persistence of stagnation zones and thus may be a contributing factor to its successful clinical performance. The hinge and thumbnail flow dynamics of the 17-mm Regent valve are at least equivalent to, and possibly superior to, those of the 17-mm Hemodynamic Plus valve.

Evaluation Studies as Topic↗

Fluid mechanic assessment of the total cavopulmonary connection using magnetic resonance phase velocity mapping and digital particle image velocimetry.

The total cavopulmonary connection (TCPC) is currently the most promising modification of the Fontan surgical repair for single ventricle congenital heart disease. The TCPC involves a surgical connection of the superior and inferior vena cavae directly to the left and right pulmonary arteries, bypassing the right heart. In the univentricular system, the ventricle experiences a workload which may be reduced by optimizing the cavae-to-pulmonary anastomosis. The hypothesis of this study was that the energetic efficiency of the connection is a consequence of the fluid dynamics which develop as a function of connection geometry. Magnetic resonance phase velocity mapping (MRPVM) and digital particle image velocimetry (DPIV) were used to evaluate the flow patterns in vitro in three prototype glass models of the TCPC: flared zero offset, flared 14 mm offset, and straight 21 mm offset. The flow field velocity along the symmetry plane of each model was chosen to elucidate the fluid mechanics of the connection as a function of the connection geometry and pulmonary artery flow split. The steady flow experiments were conducted at a physiologic cardiac output (4 L/min) over three left/right pulmonary flow splits (70/30, 50/50, and 30/70) while keeping the superior/inferior vena cavae flow ratio constant at 40/60. MRPVM, a noninvasive clinical technique for measuring flow field velocities, was compared to DPIV, an established in vitro fluid mechanic technique. A comparison between the results from both techniques showed agreement of large scale flow features, despite some discrepancies in the detailed flow fields. The absence of caval offset in the flared zero offset model resulted in significant caval flow collision at the connection site. In contrast, offsetting the cavae reduced the flow interaction and caused a vortex-like low velocity region between the caval inlets as well as flow disturbance in the pulmonary artery with the least total flow. A positive correlation was also found between the direct caval flow collision and increased power losses. MRPVM was able to elucidate these important fluid flow features, which may be important in future modifications in TCPC surgical designs. Using MRPVM, two- and three-directional velocity fields in the TCPC could be quantified. Because of this, MRPVM has the potential to provide accurate velocity information clinically and, thus, to become the in vivo tool for TCPC patient physiological/functional assessment.

Biomedical Engineering↗

Experimental investigation of the steady flow downstream of the St. Jude bileaflet heart valve: a comparison between laser Doppler velocimetry and particle image velocimetry techniques.

This study investigates turbulent flow, based on high Reynolds number, downstream of a prosthetic heart valve using both laser Doppler velocimetry (LDV) and particle image velocimetry (PIV). Until now, LDV has been the more commonly used tool in investigating the flow characteristics associated with mechanical heart valves. The LDV technique allows point by point velocity measurements and provides enough statistical information to quantify turbulent structure. The main drawback of this technique is the time consuming nature of the data acquisition process in order to assess an entire flow field area. Another technique now used in fluid dynamics studies is the PIV measurement technique. This technique allows spatial and temporal measurement of the entire flow field. Using this technique, the instantaneous and average velocity flow fields can be investigated for different positions. This paper presents a comparison of PIV two-dimensional measurements to LDV measurements, performed under steady flow conditions, for a measurement plane parallel to the leaflets of a St. Jude Medical (SJM) bileaflet valve. Comparisons of mean velocity obtained by the two techniques are in good agreement except for where there is instability in the flow. For second moment quantities the comparisons were less agreeable. This suggests that the PIV technique has sufficient temporal and spatial resolution to estimate mean velocity depending on the degree of instability in the flow and also provides sufficient images needed to duplicate mean flow but not for higher moment turbulence quantities such as maximum turbulent shear stress.

Biomedical Engineering↗

An in vitro study of the hinge and near-field forward flow dynamics of the St. Jude Medical Regent bileaflet mechanical heart valve.

The most widely implanted prosthetic valve is the mechanical bileaflet. Recent clinical experiences suggest that some designs are more prone to thromboembolic episodes than others. This study evaluated the hinge flow and near-field forward flow of the new St. Jude Medical Regent bileaflet mechanical heart valve. Laser Doppler velocimetry measurements were conducted within the hinge and near-field forward flow regions of the Regent valve. These pulsatile flow velocity measurements were animated in time to visualize the flow fields throughout the cardiac cycle. During forward flow, a recirculation region developed in the inflow pocket of the Regent hinge but was subsequently abolished by strong backflow during valve closure. Leakage velocities in the hinge region reached 0.72 m/s and Reynolds shear stresses reached 2,600 dyn/cm2. Velocities in the near-field region were highest in the lateral orifice jet, reaching 2.1 m/s. Small regions of separated flow were observed adjacent to the hinge region. Leaflet motion through the Regent hinge creates a washout pattern which restricts the persistence of stagnation zones in its hinge. Based upon the results of these studies, the hematological performance of the Regent series should be at least equivalent to the performance of the Standard series.

Biomedical Engineering↗

Computational modeling of left heart diastolic function: examination of ventricular dysfunction.

A computational model that accounts for blood-tissue interaction under physiological flow conditions was developed and applied to a thin-walled model of the left heart. This model consisted of the left ventricle, left atrium, and pulmonary vein flow. The input functions for the model included the pulmonary vein driving pressure and time-dependent relationship for changes in chamber tissue properties during the simulation. The Immersed Boundary Method was used for the interaction of the tissue and blood in response to fluid forces and changes in tissue pathophysiology, and the fluid mass and momentum conservation equations were solved using Patankar's Semi-Implicit Method for Pressure Linked Equations (SIMPLE). This model was used to examine the flow fields in the left heart under abnormal diastolic conditions of delayed ventricular relaxation, delayed ventricular relaxation with increased ventricular stiffness, and delayed ventricular relaxation with an increased atrial contraction. The results obtained from the left heart model were compared to clinically observed diastolic flow conditions, and to the results from simulations of normal diastolic function in this model [1]. Cases involving impairment of diastolic function were modeled with changes to the input functions for fiber relaxation/contraction of the chambers. The three cases of diastolic dysfunction investigated agreed with the changes in diastolic flow fields seen clinically. The effect of delayed relaxation was to decrease the early filling magnitude, and this decrease was larger when the stiffness of the ventricle was increased. Also, increasing the contraction of the atrium during atrial systole resulted in a higher late filling velocity and atrial pressure. The results show that dysfunction can be modeled by changing the relationships for fiber resting-length and/or stiffness. This provides confidence in future modeling of disease, especially changes to chamber properties to examine the effect of local dysfunction on global flow fields.

Blood Flow Velocity↗

Three-dimensional computational model of left heart diastolic function with fluid-structure interaction.

Aided by advancements in computer speed and modeling techniques, computational modeling of cardiac function has continued to develop over the past twenty years. The goal of the current study was to develop a computational model that provides blood-tissue interaction under physiologic flow conditions, and apply it to a thin-walled model of the left heart. To accomplish this goal, the Immersed Boundary Method was used to study the interaction of the tissue and blood in response to fluid forces and changes in tissue pathophysiology. The fluid mass and momentum conservation equations were solved using Patankar's Semi-Implicit Method for Pressure Linked Equations (SIMPLE). A left heart model was developed to examine diastolic function, and consisted of the left ventricle, left atrium, and pulmonary flow. The input functions for the model included the pulmonary driving pressure and time-dependent relationship for changes in chamber tissue properties during the simulation. The results obtained from the left heart model were compared to clinically observed diastolic flow conditions for validation. The inflow velocities through the mitral valve corresponded with clinical values (E-wave = 74.4 cm/s, A-wave = 43 cm/s, and E/A = 1.73). The pressure traces for the atrium and ventricle, and the appearance of the ventricular flow fields throughout filling, agreed with those observed in the heart. In addition, the atrial flow fields could be observed in this model and showed the conduit and pump functions that current theory suggests. The ability to examine atrial function in the present model is something not described previously in computational simulations of cardiac function.

Biomedical Engineering↗

Geometric distribution of chordae tendineae: an important anatomic feature in mitral valve function.

BACKGROUND AND AIM OF THE STUDY: This study examined the geometric distribution of chordae tendineae and their importance in compensating for papillary muscle (PM) displacement. METHODS: Anatomic, chordal mechanics and hemodynamic measurements were performed with porcine mitral valves. For hemodynamic measurements, physiological pulsatile flow conditions were maintained, and PM positions varied. Leaflet coaptation was documented by 2-D echocardiography, and regurgitation measured directly. RESULTS: Anatomic measurements showed the sum of marginal leaflet and marginal chordal lengths to exceed basal chordal length (1.8+/-0.4 versus 2.8+/-0.7 cm for anterior leaflets; 1.6+/-0.3 versus 2.5+/-0.6 cm for posterior leaflets). Triangular structures existed between basal chordae and marginal chordae with the marginal leaflet as the third side. Basal chordae resisted apical PM displacement in static experiments, while marginal chordae governed leaflet closure in hemodynamic experiments. Under pulsatile flow conditions, apical PM displacement decreased leaflet coaptation length and increased regurgitation (9.4+/-2.1 versus 4.0+/-1.6 ml). When marginal chordae were fused to the basal chordae, eliminating the role of the marginal chordae, severe regurgitation resulted (28.5+/-5.0 ml with apical PM displacement). CONCLUSION: Based on triangular structures involving the basal and marginal chordae, a compensatory mechanism was described which explains how the severity of mitral regurgitation can vary following PM displacement. Basal chordae provide a constant connection between the annulus and papillary muscles, while marginal chordae maintain marginal leaflet flexibility, governing proper valve closure. This study relates chordal distribution to normal valve function, and provides a better understanding of breakdown in valve function under pathophysiological conditions.

Animals↗

Determinants of pulmonary venous flow reversal in mitral regurgitation and its usefulness in determining the severity of regurgitation.

Pulmonary venous flow (PVF) reversal is observed in mitral regurgitation (MR) and can be detected by Doppler echocardiography. However, the determinants of PVF alterations in MR have not been analyzed with simultaneous quantitative methods, and the diagnostic accuracy of flow reversal is uncertain. Prospectively, in 128 patients with isolated MR of various degrees (regurgitant fraction 4% to 81%), Doppler echocardiography was used to measure PVF velocity simultaneously to quantify MR by 2 methods and to perform a comprehensive hemodynamic assessment. Systolic PVF velocity was 4 +/- 56 cm/s (systolic flow reversal in 39 patients) and showed the strongest correlations with mitral effective regurgitant orifice (r = -0.56, p <0.0001). In multivariate analysis, larger effective regurgitant orifice (p <0.0001), eccentric jets (p = 0.0023), longer jets (p = 0.0033), and lower mitral regurgitant velocity (p = 0.0015) were independent determinants of decreased systolic PVF velocity. In organic MR, increased filling pressures were associated with systolic PVF reversal. Blunted systolic flow was associated with shorter mitral deceleration time (p <0.0001) and enlarged left atrium (p = 0.0007). For the diagnosis of severe MR (regurgitant orifice > or = 35 mm2, regurgitant fraction > or = 50%), systolic flow reversal sensitivity was 61% and 60%, and specificity was 92% and 85%, respectively. Among 29 patients in whom surgery demonstrated severe mitral lesions, 12 (41%) had no systolic flow reversal preoperatively. In patients with MR, the determinants of systolic PVF are complex and, in addition to the degree of MR, include the hemodynamic consequences of MR, jet characteristics, left ventricular filling, and left atrial volume alterations. Consequently, systolic PVF reversal is a useful sign of severe MR but of relatively low sensitivity, emphasizing the importance of quantifying MR.

Aged↗

A semi-automated method to quantify left ventricular diastolic inflow propagation by magnetic resonance phase velocity mapping.

A new method of analysis was used for clinical magnetic resonance phase velocity mapping (PVM) to quantify propagation speed (PS) of early diastolic left ventricular (LV) inflow. A group of older volunteers (OV; n = 21, age 58+/-11 years) and a group of aortic stenosis patients (AS; n = 21, age 69+/-8 years) were studied. PVM was used to measure diastolic inflow in the LV outflow tract plane. PS was quantified by a semi-automated method (Auto) and by an operator (Manual). The mean+/-SD PS was 0.71+/-0.21 (Auto) and 0.67+/-0.23 (Manual) m/sec in the OV group, versus 0.49+/-0.28 (Auto) and 0.43+/-0.18 m/sec (Manual) in the AS group. There were no differences in peak transmitral E-wave (P = 0.70) between OV and AS. However, there were differences in PS-Auto (P = 0.0079) and PS-Manual (P = 0.0007) between the two groups. PS is a promising index for identifying diastolic LV dysfunction in AS patients. The semi-automated technique is a practical approach for quantifying LV filling.

Adult↗

Toward designing the optimal total cavopulmonary connection: an in vitro study.

BACKGROUND: Understanding the total cavopulmonary connection (TCPC) hemodynamics may lead to improved surgical procedures which result in a more efficient modified circulation. Reduced energy loss will translate to less work for the single ventricle and although univentricular physiology is complex, this improvement could contribute to improved postoperative outcomes. Therefore to conserve energy, one surgical goal is optimization of the TCPC geometry. In line with this goal, this study investigated whether addition of caval curvature or flaring at the connection conserves energy. METHODS: TCPC models were made varying the curvature of the caval inlet or by flaring the anastomosis. Steady flow pressure measurements were made to calculate the power loss attributed to each connection design over a range of pulmonary flow splits (70:30 to 30:70). Particle flow visualization was performed for each design and was qualitatively compared to the power losses. RESULTS: Results indicate that curving the cavae toward one pulmonary artery is advantageous only when the flow rate from that cavae matches the flow to the pulmonary artery. Under other pulmonary flow split conditions, the losses in the curved models are significant. In contrast, fully flaring the anastomosis reduced losses over the range of pulmonary flow splits. Power losses were 56% greater for the curving as compared to flaring. Fully flaring without caval offset reduced losses 45% when compared to previous models without flaring. If flaring on all sides was implemented with caval offset, power losses reduced 68% compared to the same nonflared model. CONCLUSIONS: The results indicate that preferentially curving the cavae is only optimal under specific pulmonary flow conditions and may not be efficient in all clinical cases. Flaring of the anastomosis has great potential to conserve energy and should be considered in future TCPC procedures.

Anastomosis, Surgical↗

Chordal force distribution determines systolic mitral leaflet configuration and severity of functional mitral regurgitation.

OBJECTIVES: The purpose of this study was to investigate the impact of the chordae tendineae force distribution on systolic mitral leaflet geometry and mitral valve competence in vitro. BACKGROUND: Functional mitral regurgitation is caused by changes in several elements of the valve apparatus. Interaction among these have to comply with the chordal force distribution defined by the chordal coapting forces (F(c)) created by the transmitral pressure difference, which close the leaflets and the chordal tethering forces (FT) pulling the leaflets apart. METHODS: Porcine mitral valves (n = 5) were mounted in a left ventricular model where leading edge chordal forces measured by dedicated miniature force transducers were controlled by changing left ventricular pressure and papillary muscle position. Chordae geometry and occlusional leaflet area (OLA) needed to cover the leaflet orifice for a given leaflet configuration were determined by two-dimensional echo and reconstructed three-dimensionally. Occlusional leaflet area was used as expression for incomplete leaflet coaptation. Regurgitant fraction (RF) was measured with an electromagnetic flowmeter. RESULTS: Mixed procedure statistics revealed a linear correlation between the sum of the chordal net forces, sigma[Fc - FT]S, and OLA with regression coefficient (minimum - maximum) beta = -115 to -65 [mm2/N]; p < 0.001 and RF (beta = -0.06 to -0.01 [%/N]; p < 0.001). Increasing FT by papillary muscle malalignment restricted leaflet mobility, resulting in a tented leaflet configuration due to an apical and posterior shift of the coaptation line. Anterior leaflet coapting forces increased due to mitral leaflet remodeling, which generated a nonuniform regurgitant orifice area. CONCLUSIONS: Altered chordal force distribution caused functional mitral regurgitation based on tented leaflet configuration as observed clinically.

Animals↗

Mitral valve compensation for annular dilatation: in vitro study into the mechanisms of functional mitral regurgitation with an adjustable annulus model.

BACKGROUND AND AIM OF THE STUDY: Mitral annulus dilatation has been identified as an important factor in functional mitral regurgitation (FMR). However, the pathophysiologic interaction of annular dilatation and papillary muscle (PM) displacement in FMR, which occurs clinically in left ventricular (LV) dilatation, is still not well understood. It is difficult to separate these competing factors in vivo, leading to confusion in identifying the real role of the annular dilatation in FMR and its interaction with PM displacement. METHODS: To better understand the competing factors, an in vitro model was developed with a D-shaped adjustable mitral annulus that could be changed from 5.5 cm2 to 13.0 cm2 during experiments, independent of varying PM positions. Six excised normal porcine mitral valves were mounted in a left ventricular model with the adjustable annulus device and tested in a physiologic pulsatile flow system under normal cardiac output and left ventricular pressure (5.0 l/min, 120 mmHg). Papillary muscles were placed in normal and then displaced to an apical posterolateral position, to simulate pathological conditions seen clinically. Regurgitation was measured directly by a flow probe and the mitral valve geometry and leaflet coaptation were recorded by video camera through the model's atrium window. In addition, 2D echocardiography was used to evaluate leaflet coaptation and color Doppler flow mapping to detect the regurgitant flow field. RESULTS: The results showed that in normal PM position, the mitral regurgitant was consistently at low level until the annulus was enlarged to 1.75 times the normal size, at which time it increased sharply. Papillary muscle apical posterolateral displacement, which simulates a dilated LV, caused regurgitation to occur earlier (1.5 times the normal annulus size), and had an increased regurgitant volume (p < 0.05). The leaflet gaps were first observed at the commissural areas of the valves, consistent with the location of regurgitant jets detected by color Doppler flow mapping. Asymmetric PM displacement created more regurgitation than both the symmetric PM tethering (p = 0.063) and normal PM position (p < 0.01). The regurgitant jets were observed at the same commissural side as the PM displacement, even without significant enlargement of the annulus. CONCLUSIONS: This in vitro study provides insight into the interaction between annular dilatation and PM displacement on FMR. The resulting effects and their overall similarity to clinical observation could help further understand the mechanism of FMR and provide additional information to improve future therapeutic strategies.

Dilatation, Pathologic↗

Valve orifice area alone is an insufficient index of aortic stenosis severity: effects of the proximal and distal geometry on transaortic energy loss.

BACKGROUND AND AIMS OF THE STUDY: Standard measures of hemodynamic severity of aortic valve stenosis vary widely among patients with and without clinical symptoms. Our hypothesis is that valve orifice area alone is not the sole determinant of adverse clinical outcome. Stenotic orifice area ratio is ratio of the cross-sectional stenotic orifice area to the down-stream, ascending aorta cross-sectional area. Determination of workload together with aortic valve orifice area ratio might improve risk stratification among asymptomatic patients with critical aortic stenosis. Accordingly, application of both parameters together might be useful in guiding management decisions in this condition. METHODS: In this study the dependency of transaortic fluid mechanical energy transfer (one component of left ventricular workload) on aortic valve orifice area is shown using modeling and experimental techniques. RESULTS: For a stroke volume of 62 ml at a heart rate of 60 beats/min, the piston work (analogous to left ventricular work) increased by 17% as the stenotic orifice area ratio decreased from 0.60 to 0.25, by 35% as the ratio fell from 0.25 to 0.20, and by 73% as the ratio fell from 0.20 to 0.10. CONCLUSIONS: As predicted by the fundamental fluid mechanical theory, simulated left ventricular work and energy loss in aortic stenosis are influenced not only by the effective stenotic valve orifice area, but also by the geometry of the inflow and outflow conduits, proximal and distal to the valve. These findings might explain clinically observed discrepancies between valve orifice area and the onset of the classical symptoms of severe aortic stenosis that reflect the left ventricular workload. Consideration of the left ventricular work in addition to the effective valve orifice area should enhance clinical evaluation, prognostication and risk stratification among patients with severe aortic stenosis.

Aorta↗

Papillary muscle misalignment causes multiple mitral regurgitant jets: an ambiguous mechanism for functional mitral regurgitation.

BACKGROUND AND AIMS OF THE STUDY: The study aim was to test the hypothesis that asymmetric alignment (misalignment) of the papillary muscles is sufficient to cause incomplete mitral leaflet coaptation and functional mitral regurgitation (MR). METHODS: Different spatial relationships between the papillary muscles and the mitral annulus were investigated in isolated porcine mitral valves in vitro to assess the impact on mitral valve competence. The systolic occlusional leaflet area (OLA) needed to cover the mitral orifice and the anterolateral (ACOM) and posteromedial (PCOM) commissural portion (OLA(ACOM), OLA(PCOM)) were assessed by 2D echocardiography to quantitate incomplete mitral leaflet coaptation. The regurgitant fraction (RF) and MR jet location were assessed by a flow meter and color Doppler ultrasound. RESULTS: Posterolateral dislocation of the posteromedial papillary muscle impaired mitral leaflet coaptation at the corresponding half-portion of the mitral orifice (OLA(PCOM): 351-397 mm2 versus 296 mm2 (normal); p < 0.001) and modified the contralateral part (OLA(ACOM): 354-387 mm2 versus 304 mm2 (normal); p <0.001). The mitral leaflet coaptation line moved in apical and posterior directions, creating a commissural MR orifice at the PCOM side. At the ACOM side, anterior leaflet prolapse and restricted posterior leaflet mobility created an additional commissural regurgitant jet (RF = 0.11-0.13). Symmetrical papillary muscle misalignment restricted mitral leaflet mobility on both sides of the orifice in a synergistic manner (OLA(PCOM): 416-459 mm2 and OLA(ACOM): 427-489 mm2; both p <0.001 versus normal). The central MR jet orifice, which extended towards both commissures, caused more significant MR (RF = 0.15-0.26). CONCLUSIONS: Papillary muscle misalignment caused mitral regurgitant jet ambiguity with an anterior MR jet location following posteromedial papillary muscle displacement. These findings may improve understanding of the relation between myocardial lesion and mitral regurgitant jet location and thereby facilitate rational strategies for valvular interventions.

Animals↗