Search PubMed⌕ Search

Biomedical subjects

A P Kiraly

Publications and source records attributed to A P Kiraly.

3 recordsLinked to original sources

Three-dimensional path planning for virtual bronchoscopy.

Multidetector computed-tomography (MDCT) scanners provide large high-resolution three-dimensional (3-D) images of the chest. MDCT scanning, when used in tandem with bronchoscopy, provides a state-of-the-art approach for lung-cancer assessment. We have been building and validating a lung-cancer assessment system, which enables virtual-bronchoscopic 3-D MDCT image analysis and follow-on image-guided bronchoscopy. A suitable path planning method is needed, however, for using this system. We describe a rapid, robust method for computing a set of 3-D airway-tree paths from MDCT images. The method first defines the skeleton of a given segmented 3-D chest image and then performs a multistage refinement of the skeleton to arrive at a final tree structure. The tree consists of a series of paths and branch structural data, suitable for quantitative airway analysis and smooth virtual navigation. A comparison of the method to a previously devised path-planning approach, using a set of human MDCT images, illustrates the efficacy of the method. Results are also presented for human lung-cancer assessment and the guidance of bronchoscopy.

Algorithms↗

Extraction of the hepatic vasculature in rats using 3-D micro-CT images.

High-resolution micro-computed tomography (CT) scanners now exist for imaging small animals. In particular, such a scanner can generate very large three-dimensional (3-D) digital images of the rat's hepatic vasculature. These images provide data on the overall structure and function of such complex vascular trees. Unfortunately, human operators have extreme difficulty in extracting the extensive vasculature contained in the images. Also, no suitable tree representation exists that permits straight-forward structural analysis and information retrieval. This work proposes an automatic procedure for extracting and representing such a vascular tree. The procedure is both computation and memory efficient and runs on current PCs. As the results demonstrate, the procedure faithfully follows human-defined measurements and provides far more information than can be defined interactively.

Angiography↗

Automatic axis generation for virtual bronchoscopic assessment of major airway obstructions.

Virtual bronchoscopy (VB) has emerged as a paradigm for more effective 3D CT image evaluation. Systematic evaluation of a 3D CT chest image using VB techniques, however, requires precomputed guidance data. This guidance data takes the form of central axes, or centerlines, through the major airways. We propose an axes-generation algorithm for VB assessment of 3D CT chest images. For a typical high-resolution 3D CT chest image, the algorithm produces a series of airway-tree axes, corresponding airway cross-sectional area measurements, and a segmented airway tree in a few minutes on a standard PC. Results for phantom and human airway-obstruction cases demonstrate the efficacy of the algorithm. Also, the algorithm is demonstrated in the context of VB-based 3D CT assessment.

Airway Obstruction↗