Search PubMed⌕ Search

Biomedical subjects

A P Hoeks

Publications and source records attributed to A P Hoeks.

At least 73 records · Page 4Linked to original sources

Assessment of inhomogeneities in elastic properties of in situ and reversed saphenous vein grafts in humans.

The elastic properties of newly implanted in situ (IS, n = 11) and reversed (RV, n = 21) saphenous grafts were studied with the use of Vessel Wall Doppler Tracking. From diameter, diameter change and simultaneously recorded pulse pressure, distensibility coefficient (DC) representing the intrinsic elastic properties and compliance coefficient (CC), a parameter of haemodynamic capacity, were calculated. In order to obtain a mechanical profile, the parameters were assessed at defined sites down the graft and native arterial system. In the RV group the reversal of the grafts resulted in a difference in diameter around the proximal anastomoses (7.4 vs. 4.3 mm, p < 0.01) and from proximal to distal (4.3 vs. 5.9 mm, p < 0.01) in the grafts; around the distal anastomoses no differences in diameter were observed. Due to the natural taper of the in situ grafts, diameter decreased from proximal to distal in the grafts (4.5 vs. 3.2 mm, p < 0.05) and no size differences were found around the anastomoses. In the RV group a decrease in DC was observed from proximal to distal in the grafts; whereas in the IS group no change in DC was found from proximal to distal in the grafts but a decrease in DC was observed around the distal anastomoses. In the RV group, a decrease in CC at the proximal anastomoses was observed (0.25 vs. 0.09 mm2/kPa, p < 0.01). In the IS group no change in CC was observed around the proximal anastomoses and distal anastomoses.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Studies of the vessel wall properties in hemodialysis patients.

Compliance is an important property of the arterial system and abnormalities in compliance can greatly affect cardiovascular function. The elastic properties of the common carotid artery were therefore studied in 24 normotensive hemodialysis patients and 24 healthy normotensives using a noninvasive technique. The hemodialysis patients and the control subjects were matched for blood pressure. Arterial distension was measured by Doppler analysis of the vessel wall movements and blood pressure was recorded by finger-phlethysmography (Finapres). The vessel wall distensibility (DC: 2.49 +/- 0.23 10(-3)/mm Hg; mean +/- SEM) was significantly reduced and the end diastolic diameter (d: 7.3 +/- 0.3 mm) was significantly increased in younger hemodialysis patients (36.3 +/- 2.0 years) when compared with age-related controls (DC: 3.44 +/- 0.24 10(-3)/mm Hg; d: 6.3 +/- 0.3 mm; mean +/- SEM). In older hemodialysis patients (60.2 +/- 2.3 years), there was no significant difference in vessel wall distensibility (DC: 1.55 +/- 0.15 10(-3)/mm Hg) and vessel diameter (d: 7.8 +/- 0.3 mm) as compared with age-matched controls (DC: 1.77 +/- 0.14 10(-3)/mm Hg; d: 7.2 +/- 0.3 mm). The results show that vessel wall distensibility of the common carotid artery is decreased in younger hemodialysis patients as compared with age-matched healthy subjects. The volume expanded state in hemodialysis patients cannot account for the decreased arterial distensibility, since volume depletion by hemodialysis was not associated with a significant change of arterial distensibility (DC 2.14 +/- 0.44 10(-3)/mm Hg before, DC 2.26 +/- 0.45 10(-3)/mm Hg after ultrafiltration, NS).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Short-term variation in the elastic properties of a muscular artery in humans.

1. Information on the interaction between mechanical strain and the elastic properties of large arteries could give insight to the origin of haemodynamic vascular injury, possibly resulting in formation of atherosclerotic plaques. Intra-individual variation in the elastic properties of muscular arteries measured using non-invasive techniques has been observed. This variation could be due to changes in blood pressure, since the elastic properties of muscular arteries are strongly non-linear. 2. The objective of the present study was to evaluate variability in the elastic properties of a muscular artery over a time period of up to 1 h. Furthermore, the relation between changes in elastic properties and alterations in blood pressure was studied. With a non-invasive high-resolution ultrasound technique, the diameter and distension of the femoral artery were assessed by repeated measurements in 10 healthy subjects (mean age 27 +/- 2.9 years) under resting conditions over 40-60 min. Intra-arterial blood pressure of the contralateral common femoral artery and heart rate were recorded simultaneously. From the distension and pulse pressure, the distension/pressure ratio was calculated, a measure of the compliance. For each parameter the variation coefficient was computed. 3. In all subjects a considerable variation was found in distension (mean variation coefficient 14.8%) but not in pulse pressure (mean variation coefficient 3.7%). The expected positive correlation between pulse pressure and distension was absent in eight subjects. As a consequence, large intra-individual variation was found in the distension/pressure ratio (mean variation coefficient 15.3%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Evaluation of reproducibility of a vessel wall movement detector system for assessment of large artery properties.

OBJECTIVE: Arterial distensibility (DC) and compliance (CC) are vessel wall properties of large arteries that can be measured non-invasively with a custom made vessel wall movement detector system (VWMDS). This study investigated the reproducibility of this device in 10 volunteers. METHODS: To investigate intraobserver intrasession and intraobserver intersession variability, arterial diameter (D) and relative change in diameter during the heart cycle (delta D/D) were measured in the elastic common carotid artery, and in the muscular femoral and brachial arteries. Interobserver intrasession variability was examined in common carotid artery by two observers, while interobserver variability on the same image was assessed for common carotid and femoral arteries. Variability was expressed as the coefficient of variation. RESULTS: For common carotid artery, intraobserver intrasession variability was 7.9(SEM 1.6)% (delta D/D), 4.5(1.1)% (D), 8.3(1.3)% (DC), and 9.1(2.6)% (CC), respectively. In femoral artery it was 12.4(2.2)% (delta D/D), 2.7(0.6)% (DC), 13.4(2.2)% (DC), and 12.5(2.1)% (CC). For brachial artery it was 13.4(2.8)% (delta D/D), 2.5(0.5)% (D), 16.1(2.5)% (DC), and 15.6(2.6)% (CC). Intraobserver intersession variability was comparable to intraobserver intrasession variability for all vessels. Interobserver intrasession variability for common carotid artery was 11.3(2.6)% (delta D/D) and 8.6(1.9)% (D), but was larger for DC and CC. Interobserver variability on the same image was < 5% for common carotid and femoral arteries. CONCLUSIONS: In conclusion, the vessel wall movement detector system has a good technical reproducibility. Intraobserver intrasession and intersession variability are comparable, and are larger in muscular arteries. This might be due to a larger variation in tone of these arteries, which are under permanent neurohumoral control. Interobserver intrasession variability was larger than intraobserver variability and might be influenced by differences in observers' skill and spontaneous variation in vessel wall properties.

Adolescent↗

Effect of lisinopril and metoprolol on arterial distensibility.

Apart from lowering blood pressure, antihypertensive drugs may influence vessel wall function. In a randomized double-blind study, the effect of lisinopril and metoprolol on arterial distensibility was studied in 40 patients with essential hypertension. After a placebo run-in period, the patients were randomly treated with metoprolol (50, 100, or 200 mg) or lisinopril (5, 10, or 20 mg) for 10 weeks. In the lisinopril group, blood pressure decreased after 10 weeks of therapy from 173 +/- 10/102 +/- 5 to 155 +/- 10/85 +/- 3 mm Hg and in the metoprolol group from 167 +/- 12/102 +/- 4 to 153 +/- 8/84 +/- 3 mm Hg. Diameter (millimeters), relative change in diameter (percent), and distensibility (10(-3)/kPa) of the left common carotid artery were determined after the placebo run-in period and after 6 and 10 weeks of antihypertensive therapy. A multigate Doppler system was used to measure the vessel wall movements by Doppler analysis in M-mode; blood pressure was recorded by finger plethysmography (Finapres). Neither lisinopril nor metoprolol influenced the end-diastolic diameter of the common carotid artery after 6 and 10 weeks of treatment. In the lisinopril group, a significant increase of percent change in diameter (P < .05 compared with the baseline value; P < .05 compared with the metoprolol group) and distensibility (P < .01 compared with the baseline value; P < .05 compared with the metoprolol group) was observed. The results show that lisinopril but not metoprolol improves arterial distensibility in essential hypertension. Pressure-independent effects of angiotensin converting enzyme inhibitors may be important modulators of adaptive changes in the arterial wall.

Adult↗

Ultrasonic B-mode image enhancement based on level-dependent spread functions.

The concept of level-dependent spatial summation is applied to the 2-dimensional amplitude distribution comprising an ultrasonic brightness image. The distribution is convolved with a level-dependent kernel. The size (i.e., extent) of the kernel is inversely proportional to the local signal level. The result is a 2-dimensional distribution of Mach bands, accentuating edges and providing useful information for the reduction of speckle. In addition, a small but powerful extension of the processing scheme is presented that supports global edge enhancement and contrast enhancement. The level of improvement has been quantified in terms of an increase in the lesion signal-to-noise ratio on the order of 60 percent. Only two system-dependent parameters have to be supplied for adjustment. The algorithm is rather insensitive to the exact choice of the parameters, making it quite robust. Since only a limited number of simple operations is required for the processing of a frame, the algorithm is expected to be suitable for real time application.

Image Enhancement↗

Postprocessing of velocity distributions in real-time ultrasonic color velocity imaging.

A robust processing scheme is proposed that improves the presentation of 2-dimensional velocity distributions in real-time ultrasonic color velocity images. Essentially, the algorithm is a modification of a first order recursive filter, processing each velocity signal in the spatial distribution separately from the others. It restores the sudden holes and notches in the velocity profiles that occur whenever the observed blood velocity is incidentally close to zero. At the same time, unlike conventional persistence filters, it does not influence any of the true velocity information that is measured. The result is a consistent sequence of color velocity images with smooth transitions between the borders of the consecutive velocity profiles and with an improved definition of the regions containing blood.

Blood Flow Velocity↗

Mismatch in elastic properties around anastomoses of interposition grafts for hemodialysis access.

Arteriovenous (AV) fistulas for hemodialysis access, constructed with the use of interposition grafts, are often complicated by intimal hyperplastic stenosis, mainly occurring at the venous anastomosis. In this study, mismatch in elastic properties around the arterial and venous anastomoses of graft AV fistulas in humans was quantified in order to find clues for the predisposition of intimal hyperplasia to develop at the venous anastomosis. The elastic properties of graft AV fistulas in 31 hemodialysis patients were investigated by the use of vessel wall Doppler tracking, 2 wk after construction. Nine saphenous vein grafts, 8 expanded polytetrafluoroethylene (ePTFE) grafts, and 14 stretch-PTFE (sPTFE) grafts were measured at the arterial inflow segment, the proximal graft segment, the distal graft segment, and the venous outflow segment. Area increase (AI), representing the capacity of the vessel wall to store blood volume, and relative distension, representing the intrinsic elastic properties, were calculated from diameter and distension. A decrease in AI was observed in the arterial anastomoses of all graft types. An increase in AI was found in the venous anastomosis of ePTFE and sPTFE grafts. Higher values for AI and relative distension were found at the proximal and distal graft segments of the saphenous vein grafts when compared with the prosthetic grafts. In the sPTFE grafts, the level of AI was maintained along the graft, whereas in the ePTFE grafts, a decrease in AI was found. In the arterial anastomoses of AV fistulas, a decline in the capacity to store blood volume was observed. By contrast, an increase in the capacity to store blood volume was found in the venous anastomoses.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Comparison of the performance of the RF cross correlation and Doppler autocorrelation technique to estimate the mean velocity of simulated ultrasound signals.

In pulsed Doppler systems the received RF (radio frequency) signal is multiplied by a quadrature reference signal and subsequently averaged over a short depth range to obtain a sample of the complex Doppler signal. The mean frequency of the sampled Doppler signal, obtained with the autocorrelation function, reflects the mean velocity of the scatterers moving through the sample volume. An alternative is to evaluate the two-dimensional cross correlation function of a short segment of the RF signals over subsequent lines, giving the mean velocity of the scatterers. Both methods of velocity estimation were applied to computer-generated RF signals with varying RF bandwidth, signal-to-noise ratio, and mean and width of the imposed velocity distribution. The length of the RF signal segment and the number of lines for velocity estimation (package length) affects the accuracy of the velocity estimate. It can be concluded that the cross correlation technique behaves superiorly especially for a low velocity dispersion. Furthermore, the standard deviation of the velocity estimate decreases for an increasing sample volume length and package length, while the performance of the conventional Doppler technique is rather independent of the length of the sample volume. The difference between both techniques decreases for a greater package length or for signals simulating a wide velocity distribution.

Algorithms↗

Short- and long-term effects of smoking on arterial wall properties in habitual smokers.

OBJECTIVES: This study investigated the short-term effects of smoking on hemodynamic function and distensibility and compliance of large arteries in habitual smokers. In addition, the effect of smoking was not measured in nonsmokers, but vessel wall properties were compared between smokers and nonsmokers (basal state). BACKGROUND: Smoking is a well known risk factor for atherosclerosis. Loss of distensibility and compliance of large arteries may play a role in the onset of atherosclerosis. METHODS: The distensibility and compliance coefficients of the common carotid and brachial arteries were determined from the arterial wall displacement during systole and the end-diastolic diameter by using a vessel wall movement detector and from the pulse pressure as assessed in the upper arm. Cardiac function (cardiac output, stroke volume) was measured with Doppler echocardiography. Systemic vascular resistance was calculated as mean arterial pressure divided by cardiac output. RESULTS: In habitual smokers, smoking one cigarette caused a sharp increase in blood pressure (6%) and heart rate (14%). Cardiac index increased (16%), mainly because of the marked increase in heart rate. Stroke and systemic vascular resistance indexes did not change significantly. Smoking enhanced forearm blood flow after wrist occlusion (17%), but total forearm blood flow was unchanged, suggesting an increase in muscle blood flow and a decrease in skin flow. Because of higher blood pressure, the diameter of the elastic common carotid artery increased by 3% (passive phenomenon). Distensibility of the carotid artery decreased (7%), and as a result, carotid compliance was preserved. In contrast, despite higher blood pressure, the diameter of the muscular brachial artery did not change, suggesting an increased vascular tone. Brachial distensibility and compliance decreased (18% and 19%, respectively). Habitual smokers were comparable to nonsmokers with regard to blood pressure, cardiac function, vascular resistance and vessel wall properties of large arteries. Heart rate was higher in habitual smokers (14%). CONCLUSIONS: These data indicate that in habitual smokers, smoking one cigarette causes short-term increases in arterial wall stiffness that might be harmful to the artery and increase the risk for plaque rupture. Except for a higher heart rate, no obvious long-term effect of smoking was observed on hemodynamic variables and arterial stiffness. Because acute cardiovascular events are mainly due to plaque rupture, the short-term effects of smoking might be a more important risk than long-term effects for these acute ischemic events.

Adult↗

Faster ageing of the carotid artery bifurcation in borderline hypertensive subjects.

OBJECTIVES: It has been suggested that arteries age more quickly in borderline hypertensives (BHT) than in normotensives. If this hypothesis is correct, the decrease in distensibility and compliance in the carotid artery bifurcation should be most pronounced in the carotid artery bulb, because this site is known to be the most affected by age. DESIGN: Arterial distensibility was measured non-invasively by means of an ultrasound vessel wall moving-detector system at various sites along the carotid artery bifurcation in BHT and normotensive controls. METHODS: Sixteen bifurcations of male BHT (mean age 38 years) and 15 bifurcations of normotensive age-matched controls (NTO) were studied in subjects from a population study on borderline hypertension. To evaluate age-related changes, 18 bifurcations of normotensive young male subjects (NTY; mean age 24 years) were included in the study. RESULTS: In NTY subjects no significant variations in distensibility were found along the carotid artery bifurcation, but in NTO subjects the proximal and distal parts of the carotid artery bulb were significantly less distensible than the common carotid artery. In BHT the distensibility was significantly lower at all levels in the bulb than in the common carotid artery, and its proximal part was significantly stiffer than the rest of the bulb. CONCLUSIONS: The findings in this study indicate faster ageing of the carotid artery bifurcation in male BHT than in normotensives of comparable age. In particular, the proximal part of the carotid artery bulb, where the baroreceptors are predominantly located, is most affected by the disease.

Adult↗

Effect of long-term hemodialysis on arterial compliance in end-stage renal failure.

To assess the influence of long-term hemodialysis on arterial compliance, the elastic vessel wall properties of the common carotid artery were determined in 20 normotensive renal transplant recipients (age 44.7 +/- 4.1 years) 8-12 weeks after first transplantation and in 10 healthy controls (age 45.9 +/- 5.2 years). Arterial distension was measured by using a multigate pulsed Doppler system, blood pressure curve was recorded by finger-plethysmography. 10 patients with a prior long-term hemodialysis of 51 +/- 11 months were compared to 10 patients with a prior short hemodialysis of 18 +/- 7 months. The patients and controls had been matched in respect of age, sex and blood pressure. In the long and short-term hemodialysis group, the proportion of patients (n = 10) with a history of mild hypertension was similar--mild hypertension for 25 +/- 10 months (n = 5) and for 27 +/- 9 months (n = 5). In the group with long-term hemodialysis, the cross-sectional compliance and the distensibility coefficient was significantly reduced in comparison to the group with short-term hemodialysis (p < 0.005) and to the control group (p < 0.001). A significant inverse correlation between the hemodialysis period and the distensibility coefficient (r = -0.59; p < 0.005) showed a decrease in arterial compliance with the length of hemodialysis treatment. The results demonstrate that vessel wall elasticity decreases with the length of hemodialysis treatment and is reduced by hemodialysis-dependent factors, which are detached from sustained arterial hypertension. As cause of reduced arterial compliance in long-term hemodialysis hypervolemia, hypercirculation and disturbed calcium-phosphate metabolism is suggested.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Arterial alterations with aging and high blood pressure. A noninvasive study of carotid and femoral arteries.

Noninvasive in situ evaluations of pulsatile changes of blood pressure and arterial diameter were performed at the sites of the common carotid and femoral arteries in a population of 78 untreated normotensive and hypertensive subjects. Arterial segments were studied by using an original echo-tracking technique for internal diameter and validated applanation tonometry for local pulse pressure measurements. Whereas mean arterial pressure is known to be identical in all parts of the arterial tree, pulse pressure was significantly lower in the carotid (52.7 +/- 2.2 mm Hg) than in the brachial (62.0 +/- 2.0 mm Hg) or femoral (62.5 +/- 2.5 mm Hg) arteries. Despite a higher pulse pressure and diastolic diameter, the femoral artery had a lower pulsatile change in diameter (3.47 +/- 0.18% versus 6.07 +/- 0.28%; p < 0.0001) and distensibility coefficient (9.36 +/- 0.58 versus 21.60 +/- 1.75 x 10(-3) kPa-1) than the carotid artery. Local cross-sectional compliance of the carotid artery was higher than that of the femoral artery (7.42 +/- 0.46 versus 6.20 +/- 0.28 m2.kPa-1.10(-7); p < 0.05). Whereas age was strongly correlated with arterial parameters at the site of the carotid artery (pulse pressure: r = 0.54, p < 0.0001; pulsatile change in arterial diameter: r = -0.62, p < 0.0001; distensibility coefficient: r = -0.70, p < 0.0001), no significant correlation was observed at the femoral artery. Mean blood pressure was the second factor of carotid artery alterations: the higher the mean blood pressure, the lower the distensibility of this artery (r = -0.36, p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Carotid arterial haemodynamics after mild degrees of lower-body negative pressure in man.

1. Pulsatile changes in the diameter of the common carotid artery were studied transcutaneously using an echo-tracking technique in 15 normal subjects: eight subjects before and during application of graded lower-body negative pressure from -5 to -15 mmHg, and seven subjects before and during weight-bearing head-up tilt at 30 and 60 degrees. 2. In concomitant studies of changes in forearm vascular resistance, it was seen that mild lower-body negative pressure produced deactivation of cardiopulmonary receptors without changes in systemic blood pressure or heart rate. 3. After lower-body negative pressure, a significant decrease in carotid arterial diastolic diameter [from 0.662 +/- 0.028 to 0.624 +/- 0.033 cm (lower-body negative pressure -10 mmHg) and 0.640 +/- 0.030 cm lower-body negative pressure -15 mmHg), P < 0.001 and < 0.05] was observed. 4. After head-up tilt, carotid arterial diameter was also significantly decreased at 30 and 60 degrees, whereas a significant increase in heart rate occurred only at 60 degrees and mean blood pressure did not change. 5. The study provides evidence that the geometry of the arterial wall is substantially modified by non-invasive manoeuvres such as head-up tilting and lower-body negative pressure. The latter is assumed to selectively deactivate human cardiopulmonary receptors, but the present data suggest that local changes may also influence carotid baroreceptors.

Adult↗

A comparison method for mean frequency estimators for Doppler ultrasound.

Mean frequency estimators as used in pulsed Doppler ultrasound equipment should provide an accurate (quality) and consistent (robustness) estimate over a wide range of signal conditions. In a simplified signal model, the main parameters to consider are the noise level, mean frequency, bandwidth and power of both the Doppler signal and the stationary component over a given time window. It may be expected that one estimator for a given parameter combination exhibits a good performance while another estimator for the same parameter combination behaves poorly. To allow direct comparison between different types of frequency estimators, a method is introduced to evaluate the quality and robustness of estimators for a common signal space covering a wide range of realistic parameter combinations. The method is illustrated using three different mean frequency estimators: (1) a first order autoregressive estimator in combination with a stationary echo filter; (2) a second order autoregressive estimator; and (3) a complex linear regression estimator in combination with a stationary echo filter. It is concluded that, for the parameter combination considered, the complex linear regression estimator exhibits the best quality (low variance and bias of the estimate) and robustness (consistent quality for all parameter combinations).

Artifacts↗

Introduction to large artery properties as a target for risk reduction by antihypertensive therapy.

AIM: To review the effect of antihypertensive drugs on pulsatile stress and shear stress. RESULTS OF DATA REVIEW: Mortality and morbidity in hypertension are better correlated with systolic than diastolic blood pressure, indicating a pulsatile stress effect. Distensibility and compliance are large artery properties and important determinants of pulsatile stress. beta-Blockers with vasodilating properties, several selective beta 1-blockers, angiotensin converting enzyme inhibitors and calcium antagonists are first-line antihypertensive drugs that improve these properties of large arteries. The impact of shear stress on the ill effects associated with hypertension is not clear. CONCLUSION: Some but not all classes of antihypertensive drugs can improve large artery properties, and thereby alleviate pulsatile stress.

Antihypertensive Agents↗