High-resolution functional imaging with ultrasound contrast agents based on RF processing in an in vivo kidney experiment.

Knowledge of the relative tissue perfusion distribution is valuable in the diagnosis of numerous diseases. Techniques for the assessment of the relative perfusion distribution, based on ultrasound (US) contrast agents, have several advantages compared to established nuclear techniques. These are, among others, a better spatial and temporal resolution, the lack of exposure of the patient to ionizing radiation and the relatively low cost. In the present study, US radiofrequency (RF) image sequences are acquired, containing the signal intensity changes associated with the transit of a bolus contrast agent through the microvasculature of a dog kidney. The primary objective is to explore the feasibility of calculating functional images with high spatial resolution. The functional images characterize the transit of the contrast agent bolus and represent distributions of peak time, peak value, transit time, peak area, wash-in rate and wash-out decay constant. For the evaluation of the method, dog experiments were performed under optimized conditions where motion artefacts were minimized and an IA injection of the contrast agent Levovist was employed. It was demonstrated that processing of RF signals obtained with a 3.5-MHz echo system can provide functional images with a high spatial resolution of 2 mm in axial resolution, 2 to 5 mm in lateral resolution and a slice thickness of 2 mm. The functional images expose several known aspects of kidney perfusion, like perfusion heterogeneity of the kidney cortex and a different peripheral cortical perfusion compared to the inner cortex. Based on the findings of the present study, and given the results of complimentary studies, it is likely that the functional images reflect the relative perfusion distribution of the kidney.

Animals↗

Assessment of the spatial homogeneity of artery dimension parameters with high frame rate 2-D B-mode.

To elicit vessel wall inhomogeneities in diameter and distension along an arterial segment, a 2-D vessel wall-tracking system based on fast B-mode has been developed. The frame rate of a 7.5-MHz linear-array transducer (length 36 mm) is enhanced by increasing the pulse-repetition frequency to 10 kHz, decreasing the number of echo lines per frame from 128 to 64, or increasing the interspacing between echo lines with a factor of two or four. Dedicated software has been developed to extract for each echo-line the end-diastolic diameter from the B-mode image and the 2-D distension waveform from the underlying radiofrequency (RF) information. The method is validated in tubes with various focal lesion sizes. Straight segments of presumably homogeneous common carotid arteries have also been tested. The temporal and spatial SD of diameter or distension reveals inhomogeneities in time or space (i.e., inhomogeneities in artery characteristics). The method can be implemented in echo systems supporting high frame rates and real-time processing of radiofrequency data.

Adult↗

Does B-mode common carotid artery intima-media thickness differ from M-model?

An increased intima-media thickness of the common carotid artery is thought to be an early sign of atherosclerosis. Both B- and M-mode ultrasonographic techniques are used to measure the intima-media thickness of the common carotid artery (B-IMT and M-IMT, respectively). The present study compares intima-media thickness of the common carotid artery measured with the two techniques. Intima-media thickness was measured in a random population sample of 250 subjects. Comparison was made by mean and 95% confidence intervals of differences between B-IMT and M-IMT, by linear regression analysis, and by intraclass and concordance correlation coefficients. M-IMT was + 0.011 +/- 0.091 mm (95% confidence intervals: -0.167 to + 0.188 mm) larger than B-IMT, which was 0.661 +/- 0.136 mm (range: 0.380 to 1.120 mm). Intraclass and concordance correlation coefficients were 0.802 and 0.801, respectively. In conclusion, acceptable agreement exists between the two methods and there was no important systematic difference between B-IMT and M-IMT.

Adult↗

Non-invasive assessment of local arterial pulse pressure: comparison of applanation tonometry and echo-tracking.

OBJECTIVES: Pulse pressure is not constant throughout the arterial tree. Use of pulse pressure at one arterial site as surrogate for pulse pressure at another arterial site may be erroneous. The present study compares three non-invasive techniques to measure local pulse pressure: (i) internally calibrated readings from applanation tonometry, (ii) alternative calibration of pressure waves obtained with applanation tonometry and (iii) alternative calibration of arterial distension waves obtained with echo-tracking. Alternative calibration assumes mean and diastolic blood pressure constant throughout the large artery tree. DESIGN AND METHODS: Study 1 used invasive measurements in the ascending aorta as a reference method and internally calibrated tonometer readings and alternatively calibrated pressure waves at the common carotid artery as test methods. Study 2 used alternatively calibrated pressure waves as a reference method and alternatively calibrated distension waves and internally calibrated applanation tonometer readings as test methods. RESULTS: In study 1, pulse pressure from internally calibrated tonometer readings was 10.2+/-14.3 mmHg lower and pulse pressure from alternatively calibrated pressure waves was 1.8+/-5.2 mmHg higher than invasive pulse pressure. Pulse pressure from calibrated distension waves was 3.4+/-6.9 mmHg lower than pulse pressure from alternatively calibrated pressure waves. According to British Hypertension Society criteria, pulse pressure from the internally calibrated tonometer achieved grade D and pulse pressure from alternatively calibrated pressure waves achieved grade A. Pulse pressure from calibrated distension waves achieved grade B when alternatively calibrated pressure waves were used as a reference method. CONCLUSIONS: Pulse pressure obtained from alternatively calibrated tonometer-derived pressure waves and echo-tracking-derived distension waves demonstrates good accuracy. Accuracy of pulse pressure from internally calibrated applanation tonometer readings at the carotid artery is poor.

Adult↗

Association between arterial stiffness and atherosclerosis: the Rotterdam Study.

BACKGROUND AND PURPOSE: Studies of the association between arterial stiffness and atherosclerosis are contradictory. We studied stiffness of the aorta and the common carotid artery in relation to several indicators of atherosclerosis. METHODS: This study was conducted within the Rotterdam Study in >3000 elderly subjects aged 60 to 101 years. Aortic stiffness was assessed by measuring carotid-femoral pulse wave velocity, and common carotid artery stiffness was assessed by measuring common carotid distensibility. Atherosclerosis was assessed by common carotid intima-media thickness, plaques in the carotid artery and in the aorta, and the presence of peripheral arterial disease. Data were analyzed by ANCOVA with adjustment for age, sex, mean arterial pressure, and heart rate. RESULTS: Both aortic and common carotid artery stiffness were found to have a strong positive association with common carotid intima-media thickness, severity of plaques in the carotid artery, and severity of plaques in the aorta (P: for trend <0.01 for all associations). Subjects with peripheral arterial disease had significantly increased aortic stiffness (P:=0.001) and borderline significantly increased common carotid artery stiffness (P:=0.08) compared with subjects without peripheral arterial disease. Results were similar after additional adjustment for cardiovascular risk factors and after exclusion of subjects with prevalent cardiovascular disease. CONCLUSIONS: This population-based study shows that arterial stiffness is strongly associated with atherosclerosis at various sites in the vascular tree.

Age Distribution↗

Assessment of local pulse wave velocity in arteries using 2D distension waveforms.

The reciprocal of the arterial pulse wave velocity contains crucial information about the mechanical characteristics of the arterial wall but is difficult to assess noninvasively in vivo. In this paper, a new method to assess local pulse wave velocity (PWV) is presented. To this end, multiple adjacent distension waveforms are determined simultaneously along a short arterial segment, using a single 2D-vessel wall tracking system with a high frame rate (651 Hz). Each B-mode image consists of 16 echo lines spanning a total width of 15.86 mm. Dedicated software has been developed to extract the end-diastolic diameter from the B-mode image and the distension waveforms from the underlying radiofrequency (rf) information for each echo-line. The PWV is obtained by determining the ratio of the temporal and spatial gradient of adjacent distension velocity waveforms. The proposed method is verified in a phantom and in the common carotid artery (CCA) of humans. Phantom experiments show a high concordance between the PWV obtained from 2D distension velocity waveforms (4.21 +/- 0.02 m/s) and the PWV determined using two pressure catheters (4.26 +/- 0.02 m/s). Assuming linear spatial gradients, the PWV can also be obtained in vivo for CCA and averages to 5.5 +/- 1.5 m/s (intersubject variation, n = 23), which compares well to values found in literature. Furthermore, intrasubject PWV compares well with those calculated using the Bramwell-Hill equation. It can be concluded that the PWV can be obtained from the spatial and temporal gradient if the spatial gradient is linear over the observed length of the artery, i.e. the artery should be homogenous in diameter and distension and the influence of reflections must be small.

Adult↗

Variables of the insulin resistance syndrome are associated with reduced arterial distensibility in healthy non-diabetic middle-aged women.

AIMS/HYPOTHESIS: The insulin resistance syndrome is related to arterial stiffness in diabetic subjects. Whether the insulin resistance syndrome is also related to arterial stiffness in non-diabetic subjects is less clear. We studied the association between variables of the insulin resistance syndrome in relation to arterial distensibility in healthy middle-aged non-diabetic women. METHODS: This study was done in 180 non-diabetic women, aged 43-55, selected from the general population. Arterial distensibility was assessed in the carotid artery. The associations were evaluated using linear regression analyses. RESULTS: Strong associations were found between arterial distensibility and the variables of the insulin resistance syndrome: body mass index, waist-to-hip ratio, high-density-lipoprotein-cholesterol, triglycerides, glucose, insulin, apolipoprotein A1, plasminogen activator inhibitor-1-antigen and tissue-type plasminogen activator-antigen. After additional adjustment for mean arterial pressure, common carotid arterial distensibility remained associated with body mass index: beta-coefficient (95% confidence interval) per kg/m2: -0.24 (-0.42; -0.06); waist-to-hip ratio: -26.62 (-40.59; -12.65) per m/m; triglycerides: -1.42(-2.77; -0.08) per mmol/l; plasminogen activator inhibitor-1-antigen: -0.01 (-0.02; -0.00) per ng/ml and borderline significant associated with high-density-lipoprotein-cholesterol: 1.93 (-0.01; 3.87; p = 0.07) per mmol/l. Clustering of variables of the insulin resistance syndrome was strongly related to decreased arterial distensibility which remained after adjustment for mean arterial pressure. No association was found between arterial distensibility and variables that are not part of the insulin resistance syndrome: total cholesterol, LDL-cholesterol and apolipoprotein B. CONCLUSION/INTERPRETATION: The results of this study show that variables of the insulin resistance syndrome are associated with decreased arterial distensibility of the common carotid artery in healthy non-diabetic subjects.

Adult↗

The effect of pregnancy on the compliance of large arteries and veins in healthy parous control subjects and women with a history of preeclampsia.

OBJECTIVE: Early pregnancy is characterized by a fall in total peripheral vascular resistance. In this study we tested the hypothesis that this phenomenon is accompanied by rising compliances of the large arteries and veins. STUDY DESIGN: In 42 women with a history of preeclampsia and 10 healthy parous control subjects we measured the following variables in the midfollicular phase and the midluteal phase during the menstrual cycle and again at 5 and at 7 weeks of amenorrhea: cardiac output, mean arterial pressure, carotid and femoral artery compliances, and venous compliance. The total peripheral vascular resistance was determined as the ratio of mean arterial pressure and cardiac output. After screening for thrombophilia and hypertension, women with a history of preeclampsia were divided into subgroups with hypertension, thrombophilic disorders, and no underlying abnormalities. RESULTS: In parallel with the fall in total peripheral vascular resistance during early pregnancy, femoral artery compliance and venous compliance increased in the control group. Except for venous compliance, these changes were also observed in the women with thrombophilia and a history of preeclampsia. In the subgroups of the women with a history of preeclampsia with hypertension and with no underlying disorder both arterial and venous compliance failed to increase despite a drop in total peripheral vascular resistance. CONCLUSION: These data support the concept that during normal pregnancy the fall in total peripheral vascular resistance is paralleled by improved macrovascular compliance. The latter adaptive change did not occur in women with a history of preeclampsia with hypertension or without an underlying disorder.

Arteries↗

Experimental investigation of the pulse inversion technique for imaging ultrasound contrast agents.

The application of ultrasound contrast agents aims to detect low velocity blood flow in the microcirculation. To enhance discrimination between tissue and blood containing the contrast agent, harmonic imaging is used. Harmonic imaging requires the application of narrow-band signals and is obscured by high levels of native harmonics generated in an intervening medium. To improve discrimination between contrast agent and native harmonics, a pulse inversion technique has been proposed. Pulse inversion allows wide-band signals, thus preserving the axial resolution. The present study examines the interference of native harmonics and discusses the practical difficulties of wide-band pulse inversion measurements of harmonics by a single transducer. Native harmonics are not eliminated by pulse inversion. Furthermore, only even harmonics remain and are amplified by 6 dB, alleviating the requirement for selective filtering. Finally, it is shown that the contaminating third harmonic contained in the square wave activation signal leaks through in the emitted signal. The spectral location of the contaminating third harmonic is governed by the transducer spectral characteristics while the location of the native and contrast agent second harmonics is not. Thus the contaminating third harmonic and the native and contrast agent second harmonics may overlap and interfere. Optimal discrimination requires a balance between maximal sensitivity for the second harmonic at reception and minimal interference from the contaminating third harmonic.

Acoustics↗

In spontaneously hypertensive rats alterations in aortic wall properties precede development of hypertension.

In hypertension arterial wall properties do not necessarily depend on increased blood pressure alone. The present study investigates the relationship between the development of hypertension and thoracic aortic wall properties in 1.5-, 3-, and 6-mo-old spontaneously hypertensive rats (SHR); Wistar-Kyoto rats (WKY) served as controls. During ketamine-xylazine anesthesia, compliance and distensibility were assessed by means of a noninvasive ultrasound technique combined with invasive blood pressure measurements. Morphometric measurements provided in vivo media cross-sectional area and thickness, allowing the calculation of the incremental elastic modulus. Extracellular matrix protein contents were determined as well. Blood pressure was not significantly different in 1.5-mo-old SHR and WKY, but compliance and distensibility were significantly lower in SHR. Incremental elastic modulus was not significantly different between SHR and WKY at this age. Media thickness and media cross-sectional area were significantly larger in SHR than in WKY, but there was no consistent difference in collagen density and content between the strains. Blood pressure was significantly higher in 3- and 6-mo-old SHR than in WKY, and compliance was significantly lower in SHR. The findings in this study show that in SHR, in which hypertension develops over weeks, alterations in functional aortic wall properties precede the development of hypertension. The decrease in compliance and distensibility at a young age most likely results from media hypertrophy rather than a change in intrinsic elastic properties.

Adrenergic alpha-Agonists↗

Effect of age on brachial artery wall properties differs from the aorta and is gender dependent: a population study.

Compliance and distensibility are wall properties of large arteries, which may play a role in cardiovascular disease. The purpose of this study was to investigate whether the influence of age on these vessel wall properties differs between vascular territories and is gender-dependent. In a population sample of 498 men and women 20 to 79 years of age, diameter, distensibility, and compliance coefficient of the muscular brachial artery were measured with an echo-tracking device. Distensibility of the aorta was measured with the use of pulse-wave velocity. The effects of age and gender were assessed and adjusted for confounding factors such as mean blood pressure, pulse rate, body mass index, smoking, alcohol intake, and antihypertensive treatment. Covariance analysis showed no relation between gender and distensibility of the elastic aorta. Distensibility of the muscular brachial artery was lower in men, whereas men had a larger diameter and larger compliance of the brachial artery. With age, distensibility of the aorta decreased in both sexes to the same extent, whereas distensibility of the brachial artery did not change significantly. With age, brachial artery diameter increased; this increase was more pronounced in women. In men brachial artery compliance did not change with age, whereas in women compliance of the brachial artery increased with age. This study (1) confirms that distensibility of the aorta, an elastic artery, decreases with age. (2) In contrast to the aorta, after adjustment for confounding factors, in both men and women, no relation exists between age and distensibility of the muscular brachial artery. (3) Brachial artery diameter increase with age is more pronounced in women than in men. (4) In contrast to the well-known decrease in arterial compliance of elastic arteries with age, brachial artery compliance is not decreased with age and is increased in women. In conclusion, the effect of age on large-artery wall properties is not uniform but depends on gender and vascular territory.

Adult↗

Evaluation of off-line automated intima-media thickness detection of the common carotid artery based on M-line signal processing.

Intima-media thickness (IMT) measurements have gained increasing attention, because IMT is assumed to represent the endothelial adaptive response to physiological and pathophysiological processes. The main aim of the present study was to assess the intrasubject intrasession variability of a new off-line automated radio frequency (RF) IMT method in comparison with an already established off-line manual B-mode IMT method. IMT also was assessed by means of an on-line manual B-mode and an on-line manual RF IMT method. We investigated posterior wall IMT 0-1 cm proximal to the bulb in both common carotid arteries of 16 young (20-31 y; mean 25 y) female and male and 13 elderly (51-65 y; mean 56 y) female volunteers. Two commercially available ultrasound devices (Pie Medical Scanner 200 and Ultramark 9) were used to assess the effects of signal processing on the off-line automated RF IMT method. Intrasubject intrasession variability was determined using the standard deviation to evaluate and compare the various methods. Spearman rank correlation coefficients and Bland and Altman bias and limits of agreement were calculated to objectivate the comparability between the various methods. Intrasubject intrasession variation of IMT estimates was not statistically different between any of the methods. We observed a good comparability between the commonly used off-line manual B-mode IMT method and the off-line automated RF IMT method at the level of the common carotid artery.

Adult↗

Three months use of third-generation oral contraceptives does not affect artery wall properties.

In several studies, artery wall properties have been shown to differ between men and women. It has been hypothesized that these differences may result from hormonal influences but, in a previous study, we were unable to detect any influence of the menstrual cycle on artery wall properties. Therefore, we investigated the differences in artery wall properties, if any, between the menstrual cycle and the use of a third-generation oral contraceptive for 3 months. We investigated the right common carotid (CCA) and femoral (CFA) arteries of normotensive young (18-25-y-old) women volunteers (n = 14). The arterial cross-sectional distensibility and compliance coefficients were determined by means of a specially designed ultrasonic wall-tracking device and automatic brachial artery cuff blood-pressure measurements. The menstrual cycles and the cycles during oral contraceptive use (30 microg ethinylestradiol and 75 microg gestodene) were monitored by ultrasonographic evaluation and the assessment of plasma levels of 17beta-oestradiol and progesterone. The distensibility and cross-sectional compliance coefficients of both the CCA and CFA did not differ significantly between the menstrual cycle and the use of oral contraceptives, despite different ovarian hormone levels. Brachial arterial blood pressure was also not affected. We conclude that 3 months use of a third-generation oral contraceptive does not influence the wall properties of peripheral arteries and cannot explain the observed difference between genders. The absence of a rise in blood pressure and the low androgenic profile of this specific oral contraceptive may have contributed to our findings.

Adolescent↗

An integrated system for the non-invasive assessment of vessel wall and hemodynamic properties of large arteries by means of ultrasound.

OBJECTIVES: To integrate methods for non-invasive assessment of vessel wall properties (diastolic diameter, distension waveform and intima-media thickness) and hemodynamic properties (blood flow velocity and shear rate distribution) of large arteries by means of dedicated ultrasound signal processing. METHODS: we have developed an arterial laboratory (ART-lab) system. ART-lab consists of software running on a standard personal computer, equipped with a data acquisition card for the acquisition of radio frequency (RF) ultrasound signals obtained with a conventional echo scanner. It operates either (1) off-line or (2) in real-time. Real-time operation is restricted to the assessment of vessel wall properties because of limitations in computational power. RESULTS: This paper provides an overview of ART-lab ultrasound radio frequency data acquisition and dedicated RF-signal processing methods. The capabilities of the system are illustrated with some typical applications. CONCLUSIONS: ART-lab in real-time mode is a useful tool for monitoring arterial vessel wall dynamics, while off-line it can be employed to investigate the elastic vessel wall properties in combination with hemodynamics, such as blood flow velocity and shear rate distribution.

Arteries↗

In the femoral artery bifurcation, differences in mean wall shear stress within subjects are associated with different intima-media thicknesses.

In elastic arteries, intima-media thickening is more pronounced in areas with low than with high mean and peak wall shear stress. These findings in elastic arteries are not necessarily representative of the situation in muscular arteries. The former arteries have to store volume energy, whereas the latter are mainly conductive vessels. It was the aim of the present study to investigate noninvasively whether differences in wall shear stress within a muscular artery bifurcation, if any, were associated with different intima-media thicknesses (IMTs). The effect of age on the possible differences was assessed as well. We determined IMT and mean, peak systolic, and the maximum cyclic change in shear stress near the posterior wall in the common (FC) and the superficial (FS) femoral artery 20 to 30 mm from the flow divider in 54 presumed healthy subjects between 21 and 74 years of age. Results were considered in terms of intrasubject differences. Before the study, the reliability of the ultrasonic system to assess wall shear rate and IMT was determined in terms of intrasubject variability. IMT at the posterior wall was significantly larger in the FC than in the FS, probably owing to the significantly lower mean wall shear stress at this site in the FC. The relative differences in IMT and mean wall shear stress between FC and FS were independent of age. The difference in wall shear stress between both arteries can likely be explained by a different influence of reflections. In both the FC and FS, mean, peak systolic, and maximum cyclic change in shear stress near the posterior wall did not change significantly with age, whereas IMT did increase significantly with age.

Adult↗

Menopausal status and distensibility of the common carotid artery.

Although several studies have shown that exogenous estrogens have beneficial effects on arterial characteristics, the effect of endogenous estrogen on the vascular system is still unknown. In this study, distensibility, an indicator of arterial elasticity, of the common carotid artery was compared in pre- and postmenopausal women. The study comprised 93 premenopausal and 93 postmenopausal women of similar age (range, 43 to 55 years). Women were selected from respondents to a mailed questionnaire about the menopause, which was sent to all women aged 40 to 60 years in the Dutch town of Zoetermeer (n=12 675). Postmenopausal women who were at least 3 years past natural menopause or whose menses had stopped naturally before age 48, were age-matched with premenopausal women with regular menses and without menopausal complaints. The selection aimed at maximizing the contrast in estrogen status between pre- and postmenopausal women of the same age. Distensibility of the carotid artery was measured noninvasively with B-mode ultrasound and a vessel wall movement detector system. Arterial distensibility is expressed as the change in arterial diameter (distension, DeltaD) with the cardiac cycle, adjusted for lumen diameter, pulse pressure, and mean arterial blood pressure. Compared with premenopausal women, postmenopausal women had significantly lower arterial distension (DeltaD 370.5 microm [SE 9.5] versus 397.3 microm [SE 9.6]). These results suggest that the distensibility of the common carotid artery is negatively affected by natural menopause in presumed healthy women.

Adult↗

Angle-independent motion measurement by correlation of ultrasound signals assessed with a single circular-shaped transducer.

In medicine, pulsed ultrasound is a widespread noninvasive technique that measures motion in the direction of the ultrasound beam, i.e., axial motion. The magnitude of the actual motion can be determined only if the angle between the ultrasound beam and the direction of motion (transducer-to-motion angle) is known. For blood flow measurements, current pulsed ultrasound systems assume this angle to be equal to the angle between the ultrasound beam and the longitudinal direction of the vessel, as can be estimated from a two-dimensional brightness-mode (B-mode) image that is obtained prior to the blood flow measurement. For tissue motion measurements, current pulsed ultrasound systems are mostly unable to determine the transducer-to-motion angle. Recently, a model has been derived for the correlation of(analytic) radiofrequency (rf) signals, assessed with a circular-shaped ultrasound transducer along the same line of observation. In the present paper, this model is used to derive estimators, requiring only the calculation of a few correlation coefficients, for the motion components (axial, lateral and actual) and for some of the signal parameters (center frequency, bandwidth and signal-to-noise ratio) of the assessed rf signals. The transducer-to-motion angle can be derived from the estimated motion components. For the evaluation of the estimators, rf signals were acquired with a motion-controlled experimental arrangement. The results of the evaluation study show that the transducer-to-motion angle can be estimated with a mean standard deviation of less than 2 degrees.

Algorithms↗