Search PubMed⌕ Search

Biomedical subjects

A P Fitzpatrick

Publications and source records attributed to A P Fitzpatrick.

At least 37 records · Page 2Linked to original sources

Evaluation of acute dual-chamber pacing with a range of atrioventricular delays on cardiac performance in refractory heart failure.

OBJECTIVES: This study evaluated how variations in atrioventricular (AV) delay affect hemodynamic function in patients with refractory heart failure being supported with intravenous inotropic and intravenous or oral inodilating agents. BACKGROUND: Although preliminary data have suggested that dual-chamber pacing with short AV delays may improve cardiac function in patients with heart failure, detailed Doppler and invasive hemodynamic assessment of patients with refractory New York Heart Association class IV heart failure has not been performed. METHODS: Nine patients with functional class IV clinical heart failure had Doppler assessment of transvalvular flow and right heart catheterization performed during pacing at AV delays of 200, 150, 100 and 50 to 75 ms. RESULTS: Systemic arterial, pulmonary artery, right atrial and pulmonary capillary wedge pressures, cardiac index, systemic and pulmonary vascular resistances, stroke volume index, left ventricular stroke work index (SWI) and arteriovenous oxygen content difference demonstrated no significant changes during dual-chamber pacing with AV delays of 200 to 50 to 75 ms. There were also no changes in the Doppler echocardiographic indexes of systolic or diastolic ventricular function. The study was designed with SWI as the outcome variable. Assuming a clinically significant change in the SWI of 5 g/min per m2, a type I error of 0.05 and the observed standard deviation from our study, the observed power of our study is 85% (type II error of 15%). CONCLUSIONS: Changes in AV delay between 200 and 50 ms during dual-chamber pacing do not significantly affect acute central hemodynamic data, including cardiac output and systolic or diastolic ventricular function in patients with severe refractory heart failure due to dilated cardiomyopathy.

Aged↗

Tachycardia-induced cardiomyopathy: a review of animal models and clinical studies.

The increasing prevalence of congestive heart failure has focused importance on the search for potentially reversible etiologies of cardiomyopathy. The concept that incessant or chronic tachycardias can lead to ventricular dysfunction that is reversible is supported by both animal models of chronic rapid pacing as well as human studies documenting improvement in ventricular function with tachycardia rate or rhythm control. Sustained rapid pacing in experimental animal models can produce severe biventricular systolic dysfunction. Hemodynamic changes occur as soon as 24 h after rapid pacing, with continued deterioration in ventricular function for up to 3 to 5 weeks, resulting in end-stage heart failure. The recovery from pacing-induced cardiomyopathy demonstrates that the myopathic process associated with rapid heart rates is largely reversible. Within 48 h after termination of pacing, hemodynamic variables approach control levels, and left ventricular ejection fraction shows significant recovery with subsequent normalization after 1 to 2 weeks. In humans, descriptions of reversal of cardiomyopathy with rate or rhythm control of incessant or chronic tachycardias have been reported with atrial tachycardias, accessory pathway reciprocating tachycardias, atrioventricular (AV) node reentry and atrial fibrillation (AF) with rapid ventricular responses. Control of AF rapid ventricular responses has been demonstrated to improve ventricular dysfunction with cardioversion to sinus rhythm, pharmacologic ventricular rate control and AV junction ablation and permanent ventricular pacing. The investigation of potential tachycardia-induced cardiomyopathy in patients with heart failure requires further prospective confirmation in larger numbers of patients, with study of mechanisms, patient groups affected and optimal therapies.

Animals↗

Biophysical characteristics of radiofrequency lesion formation in vivo: dynamics of catheter tip-tissue contact evaluated by intracardiac echocardiography.

During clinical radiofrequency catheter ablation a wide range of delivered power may be necessary to achieve success despite an apparently stable catheter position on fluoroscopy. The purpose of this study was to use intracardiac echocardiography to characterize the relation between catheter tip-tissue contact and the efficiency of heating during applications of radiofrequency energy in vivo and to determine whether intracardiac echocardiography could be used prospectively to improve tissue contact. A closed-loop temperature feedback control system was used during radio-frequency applications at five anatomic regions in the right atrium of 15 anesthetized dogs to ensure achievement of a predetermined temperature (70 degrees C) at the catheter tip thermistor by automatic adjustment of delivered power (maximum 100 W). The efficiency-of-heating index was defined as the ratio of steady-state temperature (degrees Celsius) to power (watts). Two-dimensional intracardiac echocardiography was used to evaluate movement of the catheter tip relative to the endocardium. Perpendicular contact was scored as good, average, or poor and lateral catheter sliding as < 2, 2 to 5, or > 5 mm. Two groups of animals were included: group 1, in which tissue contact was guided by fluoroscopic and electrographic criteria for stability of contact, with intracardiac echocardiography used simply to observe the application; and group 2, in which tissue contact was guided by intracardiac echocardiography. Of 66 applications, 18 (27.3%) had poor perpendicular contact on echocardiography, and 12 (18.2%) demonstrated lateral sliding of > 5 mm even though they had been considered to have good tissue contact by fluoroscopic and electrographic criteria. Perpendicular catheter contact and anatomic location were shown to be independently related to the efficiency-of-heating index. Applications with good perpendicular contact had a significantly higher efficiency-of-heating index and a significantly greater lesion size than those with average or poor contact. The percentage of applications having good perpendicular tissue contact and the lesion size were significantly greater when tissue contact was guided by intracardiac echocardiography compared with fluoroscopic and electrographic guidance. This study demonstrates that variations in catheter tip-tissue contact account for differences in the efficiency of tissue heating, independently of the anatomic site of the application. Poor tissue contact was observed by intracardiac echocardiography and confirmed by indexes of tissue heating in approximately one third of radiofrequency applications despite a fluoroscopic appearance and electrographic morphologic appearance suggestive of good tissue contact. There was a significant correlation between echocardiographic evaluation of tissue contact, parameters of tissue heating (efficiency-of-heating index), and lesion size. In addition, intracardiac echocardiography could be used prospectively to improve the percentage of good contact applications and increase the lesion size.

Analysis of Variance↗

Slow AV nodal pathway ablation utilizing a unique temperature controlled radiofrequency energy system.

Thirty-nine consecutive patients with symptomatic AV nodal reentrant tachycardia (AVNRT) underwent temperature guided slow AV nodal pathway ablation (group 1). Forty-three consecutive patients undergoing nontemperature guided slow AV nodal pathway ablation late in our experience compose the control population (group 2). Slow pathway ablation was achieved in all patients of both groups. The mean fluoroscopy and ablation times for group 1 were significantly shorter than for group 2 (26.1 +/- 14.9 vs 33.9 +/- 18.9 min, P < 0.05; 19.9 +/- 12.1 vs 30.9 +/- 23.3 min, P < or = 0.02). There were no episodes of coagulum formation in group 1, while there were 15 episodes (7.1% of energy applications) in group 2 (P = 0.0006) despite a significantly higher applied power in group 1 (53.4 +/- 25.1 vs 35.6 +/- 9.5W, P = 0.0001). Successful energy applications were associated with significantly higher temperatures than unsuccessful applications in group 1 (55.6 degrees +/- 5.8 degrees C vs. 52.9 degrees +/- 6.8 degrees C, P < or = 0.03). The minimum temperature required for successful ablation was 48 degrees C for two patients (5%) and was > or = 50 degrees C for the remainder of patients (37/39 [95%]). The catheter ablation system used in this study was safe, effective, and prevented coagulum formation while delivering relatively high power. In addition, shorter ablation times and radiation exposure were seen with this system. Although successful energy applications and the production of junctional rhythm were associated with higher achieved temperatures, temperature alone did not predict either endpoint. Future prospective, randomized trials are needed to confirm these findings and further evaluate the value of temperature monitoring.

Atrioventricular Node↗

Percutaneous multielectrode endocardial mapping during ventricular tachycardia in the swine model.

BACKGROUND: Identification of critical areas within the ventricular tachycardia circuit is a prerequisite for catheter ablation. Currently, mapping during ventricular tachycardia, usually performed with standard catheters, is difficult and time-consuming and can be used only in patients with hemodynamically stable tachycardia. METHODS AND RESULTS: A total of 43 pigs underwent closed-chest induction of myocardial infarction. A basket-shaped catheter carrying 64 electrodes was deployed in the left ventricle during normal sinus rhythm. Unipolar pacing at 3 mA was successful in 78% of the basket catheter electrodes, demonstrating good electrode-tissue contact. Hemodynamic and echocardiographic measurements did not reveal any significant interference with myocardial or valvular function during or after catheter deployment. One hundred eighteen episodes of monomorphic ventricular tachycardia were induced in 28 pigs through right ventricular stimulation, 81 of which were mapped and analyzed. Ventricular tachycardia mapping was rapid, requiring only several beats and < 10 seconds to complete. Presystolic potentials, a possible target for ablation, were identified in 58% of the tachycardia episodes mapped. Pathological examination revealed only minor valvular and endocardial catheter-induced lesions immediately after mapping and none a month later. CONCLUSIONS: The multielectrode catheter enables rapid and safe percutaneous endocardial mapping of ventricular tachycardia in the swine model. Exploration of the clinical potential of the multielectrode catheter seems warranted.

Animals↗

Long-term results of electrophysiologically guided sotalol therapy for life-threatening ventricular arrhythmias.

The efficacy and safety of sotalol therapy for ventricular arrhythmias was evaluated in 133 patients with drug-refractory ventricular arrhythmias. All patients had baseline electrophysiologic studies before and after oral sotalol therapy. Sixty-six patients were discharged home, treated with sotalol (52 patients without inducible ventricular tachycardia or fibrillation and 14 patients with hemodynamically stable inducible ventricular tachycardia). The mean follow-up period was 41 +/- 27 months for the 14 patients with hemodynamically stable ventricular tachycardia. Sotalol was effective in 8 of these 14 patients. Recurrent nonlethal ventricular tachycardia occurred in 3 patients; 2 patients had sudden death; and 1 patient had adverse side effects. The 52 patients without inducible ventricular tachycardia were followed up for a mean period of 36 +/- 30 months. Thirty-five of 52 patients were successfully treated. Two patients had recurrent ventricular tachycardia; both of these episodes of ventricular tachycardia occurred within the first year. Four patients had sudden cardiac death; three of these deaths occurred within the first month, and the last episode of sudden death occurred after 8 years of sotalol therapy. The actuarial incidence of sotalol efficacy was 76% at 1 year, 72% at 2 years, 64% at 4 years, and 52% at 5 years. Approximately 46% of patients receiving long-term sotalol treatment reported side effects. Side effects severe enough to warrant withdrawal of sotalol occurred in 7 (11%) patients. The results of our study suggest that sotalol is effective for selected patients with drug refractory ventricular arrhythmias. Although the incidence of side effects are high, patients appear to tolerate long-term sotalol therapy well.

Adult↗

Quality of life and outcomes after radiofrequency His-bundle catheter ablation and permanent pacemaker implantation: impact of treatment in paroxysmal and established atrial fibrillation.

One hundred seven patients underwent atrioventricular (AV)-junctional ablation and pacing for atrial fibrillation, and 90 were alive 2.3 +/- 1.2 years later. Quality of life index (1.9 +/- 1.2 to 3.6 +/- 1.1; 3.6 +/- 1.1; p<0.001) and ease of activities of daily living (2 +/- 0.4 to 2.4 +/- 0.3; p<0.001) were significantly improved. Doctor visits (10 +/- 13 to 5.06 +/-7; p<0.03), hospital admissions (2.8 +/- 6.8 vs 0.17 +/- 0.54; p<0.03, and antiarrhythmic drug trials (6.2 +/- 4 to 0.46 +/- 1.5; p<0.001) decreased significantly after treatment. Congestive heart failure episodes decreased from 18 before to 8 afterward. Twenty-eight of 36 patients with dual-chamber pacemakers remained in a dual-chamber mode at follow-up. Radiofrequency AV-junctional catheter ablation and pacing is a highly successful form of treatment for medically refractory atrial fibrillation.

Activities of Daily Living↗

Effect of patient characteristics on the yield of prolonged baseline head-up tilt testing and the additional yield of drug provocation.

OBJECTIVE: To define the value of tilt testing and hte additional yield of drug provocation over prolonged baseline tilt in different patient subgroups. (Many different protocols are in use for head-up tilt testing in heterogeneous groups of patients. Not all patients in reported series have recurrent syncope, and there is often a wide age range and a variable incidence of structural heart disease.) DESIGN: In a prospective study, baseline 60 degrees head-up tilt testing was undertaken for 45 minutes, initially without drug provocation. Patients who remained symptom free were given intravenous isoprenaline (isoproterenol) and further tilting or edrophonium (10 mg bolus) during tilt, in an order determined randomly before the start of the test. If they were symptom free after the first drug, they were given the other drug. A positive test was recorded when syncope or pre-syncope occurred with a rapid fall (> 30%) in blood pressure. The impact on tilt result of the type of symptoms, presence of significant structural heart disease (SHD), presence of a non-cardiovascular cause of sudden diminished consciousness (SDC), and age was then assessed by subgroup analysis. PATIENTS: 145 patients (73 female, mean age 51 (25), range 8-94) with one or more episodes of pre-syncope or syncope. RESULTS: 39 patients (27%, 21 female, age 49 (25) years) had positive tests and 106 (73%, 52 female, age 52 (25) years) negative tests. 27 (69%) had a positive test during baseline tilt at 20.5 (10.8) minutes, five (13%) with isoprenaline infusion, and seven (18%) with edrophonium bolus. Patients with recurrent syncope rather than single syncopal episodes or single or recurrent pre-syncope were more likely to have a positive tilt test (41% v 17%, P < 0.005) and patients with SHD or SDC (69/14 patients) were much less likely than patients without (16% v 42%, P < 0.0001). The yield of positive tests was similar if patients were below (26%) or above (27%) the mean age (50 years). When multiple factors were combined, the yield ranged from 0% for 21 patients under 50 years with SHD or SDC and without recurrent syncope to 73% in 11 patients over 50 years with recurrent syncope and no SHD or SDC. The additional yield in subgroups over 45 minute baseline tilt (70 (11)%) of isoprenaline (13 (10)%) was similar to that of edrophonium (17 (8)%, P = NS), but six (50% of those who were drug positive) patients required a second drug to produce a positive result (two with isoprenaline second, four with edrophonium second). CONCLUSIONS: Head-up tilt testing in a heterogeneous population has a low yield. Simple clinical characteristics define the type of patient who is likely to have a positive tilt test and the patient who is not and in whom other investigations should receive priority. The great majority of positive tests will occur during prolonged baseline testing if this is used. Isoprenaline and edrophonium produced similar additional yields of positive tests.

Age Factors↗

Radiofrequency catheter modification of the sinus node for "inappropriate" sinus tachycardia.

BACKGROUND: Radiofrequency catheter ablation is the treatment of choice for patients with paroxysmal supraventricular tachycardias refractory to medical therapy. However, in symptomatic patients with inappropriate sinus tachycardia resistant to drug therapy, catheter ablation of the His' bundle with permanent pacemaker insertion is currently applied. We evaluated the safety and efficacy of radiofrequency modification of the sinus node as alternative therapy for patients with inappropriate sinus tachycardia. METHODS AND RESULTS: Sixteen patients with disabling episodes of inappropriate sinus tachycardia refractory to drug therapy (4.2 +/- 0.3 drug trials) underwent either total sinus node ablation or sinus node modification. The region of the sinus node was identified as the region of earliest atrial activation in sinus rhythm during electrophysiological study. This region was further defined by use of intracardiac echocardiography (ICE) in 9 patients, in whom it was found that an ablation catheter could be guided reliably and maintained on the crista terminalis. Radiofrequency energy was delivered during tachycardia between either a standard 4-mm or custom 10-mm thermistor-imbedded catheter tip and a skin patch. Total sinus node ablation was performed successfully in all 4 patients in whom it was attempted and was characterized by a junctional escape rhythm. Sinus node modification was successfully achieved in all 12 patients in whom it was attempted and was characterized by a 25% reduction in the sinus heart rate. For the group as a whole, exercise stress testing after ablation revealed a gradual chronotropic response, with a significant reduction in maximal heart rate (132.8 +/- 6.5 versus 179.5 +/- 3.6 beats per minute [bpm]; P < .001) without evidence of an exaggerated heart rate response to a light workload (103.0 +/- 4.1 versus 139.5 +/- 3.5 bpm; P < .001). Twenty-four-hour ambulatory ECG monitoring revealed a significant decrease in maximal heart rate and mean heart rate after ablation (167.2 +/- 2.6 versus 96.7 +/- 5.0 bpm, P < .001, and 125.6 +/- 5.0 versus 54.1 +/- 5.3 bpm, P < .001, respectively). There was a significant decrease in the number of applications of radiofrequency energy required in patients undergoing modification of the sinus node when guided by ICE compared with fluoroscopy alone (3.6 +/- 0.8 versus 10.4 +/- 2.1; P < .01) as well as a decrease in fluoroscopy time (33.0 +/- 9.5 versus 58.5 +/- 8.4 minutes). After a mean follow-up period of 20.5 +/- 0.3 months, there were no recurrences of inappropriate sinus tachycardia in patients who underwent a total sinus node ablation. However, 2 patients who had a total sinus node ablation subsequently required permanent pacing because of symptomatic pauses, and 1 patient developed an ectopic atrial tachycardia. After a mean follow-up of 7.1 +/- 1.7 months, there were two recurrences of inappropriate sinus tachycardia in patients who underwent sinus node modification. However, no significant bradycardia or pauses were observed. Complications encountered during the study included 1 patient who developed transient right diaphragmatic paralysis and another patient who developed transient superior vena cava syndrome. CONCLUSIONS: Sinus node modification is feasible in humans and should be considered as an alternative to complete atrioventricular junctional ablation for patients with disabling inappropriate sinus tachycardia refractory to medical management. Sinus node modification may be aided by ICE.

Adult↗

Use of P wave configuration during atrial tachycardia to predict site of origin.

OBJECTIVES: This study sought to construct an algorithm to differentiate left atrial from right atrial tachycardia foci on the basis of surface electrocardiograms (ECGs). BACKGROUND: Atrial tachycardia is an uncommon form of supraventricular tachycardia, often resistant to drug therapy. METHODS: A total of 31 consecutive patients with atrial tachycardia due to either abnormal automaticity or triggered rhythm underwent detailed atrial endocardial mapping and successful radiofrequency catheter ablation of a single atrial focus. P wave configuration was analyzed from 12-lead ECGs during tachycardia during either spontaneous or pharmacologically induced atrioventricular block. P waves inscribed above the isoelectric line (TP interval) were classified as positive, below as negative, above and below (or conversely, below and above) as biphasic and flat P waves as isoelectric (0). In 17 patients the tachycardia was located in the right atrium: crista terminalis (n = 4); right atrial appendage (n = 4); lateral wall (n = 4); posteroinferior right atrium (n = 3); tricuspid annulus (n = 1); and near the coronary sinus (n = 1). In 14 patients, atrial tachycardia was located in the left atrium: at the entrance of the right (n = 6) or left (n = 4) superior pulmonary veins; left inferior pulmonary vein (n = 1); inferior left atrium (n = 1); base of left atrial appendage (n = 1); and high lateral left atrium (n = 1). RESULTS: There were no differences in P wave vectors between sites at the right atrial lateral wall versus the right atrial appendage or between sites at the entrance of right versus left superior pulmonary veins. However, analysis of P wave configuration showed that leads aVL and V1 were most helpful in distinguishing right atrial from left atrial foci. The sensitivity and specificity of using a positive or biphasic P wave in lead aVL to predict a right atrial focus was 88% and 79%, respectively. The sensitivity and specificity of a positive P wave in lead V1 in predicting a left atrial focus was 93% and 88%, respectively. CONCLUSIONS: 1) Analyses of surface P wave configuration proved to be reasonably good in differentiating right atrial from left atrial tachycardia foci. 2) Leads II, III and aVF were helpful in providing clues for differentiating superior from inferior foci.

Adolescent↗

Role of right atrial endocardial structures as barriers to conduction during human type I atrial flutter. Activation and entrainment mapping guided by intracardiac echocardiography.

BACKGROUND: The importance of barriers in atrial flutter has been demonstrated in animals. We used activation and entrainment mapping, guided by intracardiac echocardiography (ICE), to determine whether the crista terminalis (CT) and eustachian ridge (ER) are barriers to conduction during typical atrial flutter in humans. METHODS AND RESULTS: In eight patients, ICE was used to guide the placement of 20-pole and octapolar catheters along the CT and interatrial septum and a roving catheter to nine sites: just posterior (1) and anterior (2) to the CT along the lateral right atrium, at the fossa ovalis (3), and just posterior and anterior to the ER at the low posterolateral (4 and 5), low posterior (6 and 7), and low posteromedial (8 and 9) right atrium. Entrainment was performed, and each site was considered within the flutter circuit if the postpacing interval-flutter cycle length (PPI-FCL) and the stimulus time-activation time (stim time-act time) were < 10 msec. Split potentials were recorded along the CT with components activated in a low-to-high pattern and a high-to-low pattern. Conduction times, as percentage of FCL, were significantly different at sites on either side of the CT and ER: site 1 (33 +/- 13%) and site 2 (43 +/- 12%) (P = .02), site 4 (48 +/- 24%) and site 5 (75 +/- 8.9%) (P = .02), and site 6 (22 +/- 10%) and site 7 (82 +/- 5.3%) (P = .0009). During entrainment, no surface fusion was observed at sites 5, 7, or 9. The PPI-FCL and stim time-act time were not significantly different than 0 at sites 2, 7, 5, or 9, indicating that they were within the flutter circuit, whereas sites 1, 3, 4, and 6 were not. CONCLUSIONS: ICE enabled the correlation of functional electrophysiological properties with specific anatomic landmarks, identifying the CT and ER as barriers to conduction during human atrial flutter.

Aged↗

New algorithm for the localization of accessory atrioventricular connections using a baseline electrocardiogram.

OBJECTIVES: In this study, we propose a new algorithm for accessory atrioventricular pathway localization using a 12-lead electrocardiogram (ECG). BACKGROUND: Radiofrequency catheter ablation produces a very discrete lesion, and ECG localization based on surgical dissection is obsolete. METHODS: Stepwise discriminant analysis was used to assess the relation of 18 pre-excited ECG (QRS duration > 100 ms) variables to the site of successful ablation in 93 patients. The most discriminating variables were combined to form rules for each location. The ECGs were retested by these rules to determine predictive accuracy. RESULTS: If the precordial QRS transition was at or before lead V1, the pathway had been ablated on the left side. If it was after lead V2, the pathway had been ablated on the right side. If the QRS transition was between leads V1 and V2 or at lead V2, then if the R wave amplitude in lead I was greater than the S wave by > or = 1.0 mV, it was right-sided; otherwise, it was left-sided (p < 0.0001, sensitivity 100%, specificity 97%). Right-side pathways. If the QRS transition was between leads V2 and V3, the pathway was right septal; if after lead V4, it was right lateral. If it was between leads V3 and V4, then if the delta wave amplitude in lead II was > or = 1.0 mV, it was right septal; otherwise, it was right lateral (p < 0.0001, sensitivity 97%, specificity 95%). In right lateral locations, if the delta wave frontal axis was > or = 0 degrees, or if it was < 0 degrees but the R wave amplitude in lead III was > or = 0 mV, it was anterolateral; otherwise, it was posterolateral (p < 0.0001, sensitivity 100%, specificity 87.3%). Anteroseptal pathways had a sum of delta wave polarities in leads II, III and aVF > or = +2(p < 0.0001, sensitivity 100%, specificity 100%). Posteroseptal pathways (inferior delta wave sum < or = -2) were less well discriminated from right midseptal pathways (inferior delta wave sum < or = 1 > or = -1) (p < 0.0001, sensitivity 76.5%, specificity 71%) [corrected]. Left-sided pathways. Two or more positive delta waves in the inferior leads or the presence of an S wave amplitude in lead aVL greater than the R wave, or both, discriminated left anterolateral pathways from posterior pathways (p < 0.001, sensitivity and specificity 100%). If the R wave in lead I was greater than the S wave by > or = 0.8 mV, and the sum of inferior delta wave polarities was negative, the location was posteroseptal; otherwise, it was posterolateral (p < 0.05, sensitivity 71.4%, specificity 100%). CONCLUSIONS: Using the algorithm derived, a right-sided accessory pathway can be reliably distinguished from one that is left-sided, right free wall from right septal, right anterolateral from posterolateral and anteroseptal from other right septal pathways. Left anterolateral pathways can be distinguished from left posterior pathways and left posterolateral pathways from left posteroseptal pathways.

Algorithms↗

Permanent pacing for cardioinhibitory malignant vasovagal syndrome.

OBJECTIVE: To evaluate the effect of permanent pacing in cardioinhibitory malignant vasovagal syndrome. PATIENTS AND METHODS: 37 patients with permanent pacemakers for cardioinhibitory malignant vasovagal syndrome. All presented with syncope (median six episodes, median frequency two episodes a year) and after conventional investigation and invasive electrophysiological assessment they remained undiagnosed, and without a generally accepted indication for pacemaker implantation. In all vasovagal syncope with cardioinhibition (heart rate at syncope < 60 beats/min) developed during tilt tests performed according to the Westminster protocol (head up tilt at 60 degrees with a footplate support for 45 minutes or until syncope intervenes). Dual chamber pacemakers were implanted in 35 (95%) and VVI pacemakers in the remaining two (5%). RESULTS: Over a mean (SD) follow up since implantation of 50.2 (23.9) months symptomatic improvement occurred in 89%: 62% remained free of syncope and 27% were completely symptom free. The collective syncopal burden of these 37 patients was reduced from 136 to 11 episodes each year. During follow up three patients died from unrelated causes. Patients who become asystolic during the tilt test (sinus pause of at least four seconds) experienced no greater benefit from pacing than those with less extreme cardioinhibition. Patients who remained free of syncope since implantation were younger than those who continued to experience syncope. Patients who remained completely symptom free after implantation were younger, more likely to be male, and had had fewer syncopal episodes before implantation than those who continued to experience syncope or presyncope. No other demographic, clinical, investigative, or pacing variable suggested a more favourable outcome after implant. CONCLUSIONS: This retrospective and uncontrolled experience suggests a possible role for permanent pacing in selected patients with cardioinhibitory malignant vasovagal syndrome. Improved acquisition of tilt test data may enable better selection of patients who are suitable for permanent pacing. A randomised prospective study to compare permanent pacing with no treatment or with medical treatment in cardioinhibitory malignant vasovagal syndrome is indicated.

Adult↗

Radiofrequency catheter ablation of atrial arrhythmias. Results and mechanisms.

BACKGROUND: Radio frequency catheter ablation is accepted therapy for patients with paroxysmal supraventricular tachycardia and has a low rate of complications. For patients with atrial arrhythmias, catheter ablation of the His bundle has been an option when drugs fail or produce untoward side effects. Although preventing rapid ventricular response, this procedure requires a permanent pacemaker and does not restore the atrium to normal rhythm. Therefore, we evaluated the safety and efficacy of radiofrequency ablation directed at the atrial substrate. METHODS AND RESULTS: Thirty-seven patients with 42 atrial arrhythmias (mean +/- SD age, 41 +/- 24 years) who had failed a median of three drugs were enrolled. Diagnoses were automatic atrial tachycardia in 12, atypical atrial flutter in 1, typical atrial flutter in 18, reentrant atrial tachycardia in 8, and sinus node reentry in 3 patients. Sites for atrial flutter ablation were based on anatomic barriers in the floor of the right atrium. For automatic atrial tachycardia, the site of earliest activation before the P wave was sought. All with reentrant atrial tachycardia had previous surgery for congenital heart disease and reentry around a surgical scar, anatomic defect, or atriotomy incision and our goal was to identify a site of early activation in a zone of slow conduction. At target sites, 20 to 50 W of radiofrequency energy was delivered during tachycardia between the 4- or 5-mm catheter tip and a skin patch, except in 4 patients with atrial flutter, in whom a catheter with a 10-mm thermistor-embedded tip was used. Procedure end point was inability to reinduce tachycardia. Acute success was achieved in 11 of 12 (92%) with automatic atrial tachycardia, 17 of 18 (94%) with typical atrial flutter, 7 of 8 (88%) with reentrant atrial tachycardia, and 3 of 3 (100%) with sinus node reentry but not in the patient with atypical atrial flutter. For tachycardia involving reentry (reentrant atrial tachycardia and atrial flutter), successful ablation required severing an isthmus of slow conduction. For those with atrial flutter, this was between the tricuspid annulus and the coronary sinus os (10) or posterior (4) or posterolateral (3) between the inferior vena cava (2) or an atriotomy scar (1) and the tricuspid annulus. Deep venous thrombosis occurred in 1 patient. At mean follow-up of 290 +/- 40 days, the ablated arrhythmia recurred in 1 (9%) with automatic atrial tachycardia, 5 (29%) with atrial flutter, and 1 (14%) with reentrant atrial tachycardia, all of whom had successful repeat ablation. Previously undetected arrhythmias occurred in 2 patients who are either asymptomatic or controlled with medication. CONCLUSIONS: Ablation of automatic and reentrant atrial tachycardia and atrial flutter had a high success rate and caused no complications from energy application. Repeat procedures may be required for long-term success, especially in patients with atrial flutter. The mechanism by which ablation is successful is similar for atrial flutter and other forms of atrial reentry and involves severing a critical isthmus of slow conduction bounded by anatomic or structural obstacles. Automatic arrhythmias are abolished by directing lesions at the focus of abnormal impulse formation.

Adult↗

Radiofrequency catheter ablation guided by intracardiac echocardiography.

BACKGROUND: Radiofrequency catheter ablation requires precise positioning of the ablation electrode. Fluoroscopically guided catheter manipulation has limitations, and there are risks of radiation exposure. The purpose of this study was to examine the feasibility of guiding catheter ablation within the right atrium with catheter-based intracardiac echocardiography. METHODS AND RESULTS: A 10F, 10-MHz intracardiac imaging catheter was used to direct an ablation electrode at four or five anatomic landmarks in the right atrium. Thirty-eight radiofrequency energy applications were performed in nine anesthetized dogs, and 38 lesions were identified on pathological examination. Lesions were created a mean of 1.9 +/- 2.1 mm from the ultrasound-guided site. Twenty-six of 38 lesions (68%) were less than 2.2 mm from the imaged site. Intracardiac echocardiography also was used to confirm stable electrode-endocardial contact in 37 energy applications (97%) and identified catheter movement in 9 energy applications (24%). Discrete lesions, microcavitations, and thrombi were observed in 13 (34%), 23 (61%), and 19 (50%) of 38 energy applications, respectively. Microcavitations predicted the appearance of thrombus. Fluoroscopy time required to create four or five lesions decreased from 23 minutes in the first study to less than 2 minutes in the last five studies. CONCLUSIONS: Catheter-based intracardiac echocardiography can accurately guide catheter ablation directed at anatomic landmarks and potentially reduced ionizing radiation exposure. Intracardiac imaging can be used to confirm endocardial contact, identify electrode movement, and directly visualize lesions. Intracardiac echocardiography also can be used to identify microcavitations, which predict thrombus formation during radiofrequency energy applications.

Animals↗

Electrophysiological laboratory, electrophysiologist-implanted, nonthoracotomy-implantable cardioverter/defibrillators.

BACKGROUND: Implantable cardioverter/defibrillators (ICDs) have conventionally been implanted in the operating room by surgeons. However, technological developments have reduced size and increased simplicity, bringing the procedure into the realm of the electrophysiologist. The purpose of this study was to evaluate the safety and efficacy of implantation of the entire ICD system by electrophysiologists in an electrophysiology laboratory. METHODS AND RESULTS: Between July 1993 and February 1994, 23 patients (21 men; age, 64 +/- 11 years) underwent transvenous ICD implantation by electrophysiologists working alone, entirely in the electrophysiology laboratory. Indications for ICD were sudden death in 10 patients, uncontrolled life-threatening ventricular tachycardia in 12, and syncope with cardiomyopathy and familial sudden death in 1. Seventeen patients had coronary artery disease and a past history of acute myocardial infarction. Four patients had idiopathic dilated cardiomyopathy, 1 had coronary ectasia and poor left ventricular function, and another had poor left ventricular function related to valvular dysfunction. The mean left ventricular ejection fraction was 34 +/- 10% (range, 20% to 50%). General anesthesia was administered in 22 cases, and deep sedation was used in 1 elderly patient. After positioning of transvenous leads and subcutaneous patch/array lead positioning, defibrillation testing was performed. After transvenous and subcutaneous lead tunneling, all generators were placed subcutaneously in an abdominal pocket. The mean total time in the electrophysiology laboratory was 254 +/- 68 minutes (range, 150 to 375 minutes), with 104 +/- 42 minutes for anesthetic and other preparation, 159 +/- 45 minutes for implantation, and 8.7 +/- 5 minutes (range, 3 to 25 minutes) of fluoroscopy required for positioning of transvenous and subcutaneous lead systems. Implant times showed a significant improvement when the first 10 cases (188 +/- 44 minutes) were compared with the last 10 in the series (124 +/- 44 minutes, P < .01). The mean defibrillation threshold was 17 +/- 5 J (range, 5 to 25 J). There were 5 complications (22%): 1 patch-site hematoma, 1 pneumothorax related to subclavian venous puncture, 1 pulmonary embolism, and 2 patients requiring overnight ventilation after hemodynamic deterioration following defibrillation testing. There were no deaths, and there were no infections. The mean time to hospital discharge after the implant was 5.1 +/- 3.5 days. After 11.6 +/- 9 weeks of follow-up, all devices were functioning satisfactorily, all patients had successfully defibrillated at postimplant predischarge checkup with 29 +/- 5 J, and there had been no late complications. CONCLUSIONS: This is the first report to show that nonthoracotomy ICD implantation may be successfully carried out by electrophysiologists working alone in the electrophysiology laboratory, with a high rate of success and few complications, even in high-risk patients. This high rate of success and safety probably relates to the availability of high-quality fluoroscopy and familiarity with electrophysiology laboratory equipment and personnel.

Adult↗