Search PubMed⌕ Search

Biomedical subjects

A P Bradley

Publications and source records attributed to A P Bradley.

4 recordsLinked to original sources

On the dual structure of the auditory brainstem response in dogs.

OBJECTIVE: To use the over-complete discrete wavelet transform (OCDWT) to further examine the dual structure of auditory brainstem response (ABR) in the dog. METHODS: ABR waveforms recorded from 20 adult dogs at supra-threshold (90 and 70dBnHL) and threshold (0-15dBSL) levels were decomposed using a six level OCDWT and reconstructed at individual scales (frequency ranges) A6 (0-391Hz), D6 (391-781Hz), and D5 (781-1563Hz). RESULTS: At supra-threshold stimulus levels, the A6 scale (0-391Hz) showed a large amplitude waveform with its prominent wave corresponding in latency with ABR waves II/III; the D6 scale (391-781Hz) showed a small amplitude waveform with its first four waves corresponding in latency to ABR waves I, II/III, V, and VI; and the D5 scale (781-1563Hz) showed a large amplitude, multiple peaked waveform with its first six waves corresponding in latency to ABR waves I, II, III, IV, V, and VI. At threshold stimulus levels (0-15dBSL), the A6 scale (0-391Hz) continued to show a relatively large amplitude waveform, but both the D6 and D5 scales (391-781 and 781-1563Hz, respectively) now showed relatively small amplitude waveforms. CONCLUSIONS: A dual structure exists within the ABR of the dog, but its relative structure changes with stimulus level. SIGNIFICANCE: The ABR in the dog differs from that in the human both in the relative contributions made by its different frequency components, and the way these components change with stimulus level.

Acoustic Stimulation↗

On wavelet analysis of auditory evoked potentials.

OBJECTIVE: To determine a preferred wavelet transform (WT) procedure for multi-resolution analysis (MRA) of auditory evoked potentials (AEP). METHODS: A number of WT algorithms, mother wavelets, and pre-processing techniques were examined by way of critical theoretical discussion followed by experimental testing of key points using real and simulated auditory brain-stem response (ABR) waveforms. Conclusions from these examinations were then tested on a normative ABR dataset. RESULTS: The results of the various experiments are reported in detail. CONCLUSIONS: Optimal AEP WT MRA is most likely to occur when an over-sampled discrete wavelet transformation (DWT) is used, utilising a smooth (regularity >or=3) and symmetrical (linear phase) mother wavelet, and a reflection boundary extension policy. SIGNIFICANCE: This study demonstrates the practical importance of, and explains how to minimize potential artefacts due to, 4 inter-related issues relevant to AEP WT MRA, namely shift variance, phase distortion, reconstruction smoothness, and boundary artefacts.

Adult↗

The performance of a variable-flow indirect calorimeter.

Indirect calorimetry estimates energy expenditure from measurement of respiratory gas exchange volumes. This paper considers the design and evaluation of an indirect calorimeter, the Europa GEM, suitable for use in nutritional research. The calorimeter is of the ventilated hood, flow-through type and is intended for use with spontaneously breathing patients. Our aim was to develop an accurate, flexible instrument with a high level of automation. Performance was assessed in a laboratory simulation using reference gas injections (n = 24) producing a mean error of 0.3 +/- 2% in oxygen consumption (VO2), 1.8 +/- 1% in carbon dioxide production (VCO2) and 1.4 +/- 1.5% in respiratory quotient (RQ). In order to investigate the effect of FeCO2 on error multiplication a further subdivision (n = 8) of tests at FeCO2 = 0.5%, 0.75% and 1% was made by modulating the air flow through the hood. However, the predicted increase in system accuracy with increasing FeCO2 was not apparent in practice.

Calorimetry, Indirect↗