Search PubMed⌕ Search

Biomedical subjects

A Odgaard

Publications and source records attributed to A Odgaard.

At least 19 recordsLinked to original sources

A comparison of structural and mechanical properties in cancellous bone from the femoral head and acetabulum.

Mechanical interlock obtained by penetration of bone cement into cancellous bone is critical to the success of cemented total hip replacement (THR). Although acetabular component loosening is an important mode of THR failure, the properties of acetabular cancellous bone relevant to cement penetration are not well characterized. Bone biopsies (9 mm diameter, 10 mm long) were taken from the articular surfaces of the acetabulum and femoral head during total hip replacement. After mechanical and chemical defatting the two groups of bone specimens were characterized using flow measurement, mechanical testing and finally serial sectioning and three-dimensional computer reconstruction. The mean permeabilities of the acetabular group (1.064 x 10(-10) m2) and femoral group (1.155 x 10(-10) m2) were calculated from the flow measurements, which used saline solution and a static pressure of 9.8 kPa. The mean Young's modulus, measured non-destructively, was 47.4 MPa for the femoral group and 116.4 MPa for the acetabular group. Three-dimensional computer reconstruction of the specimens showed no significant differences in connectivity and porosity between the groups. Results obtained using femoral head cancellous bone to investigate bone cement penetration and fixation are directly relevant to fixation in the acetabulum.

Acetabulum↗

Changes in the three-dimensional microstructure of human tibial cancellous bone in early osteoarthritis.

We obtained medial and lateral subchondral cancellous bone specimens from ten human post-mortem proximal tibiae with early osteoarthritis (OA) and ten normal age- and gender-matched proximal tibiae. The specimens were scanned by micro-CT and the three-dimensional microstructural properties were quantified. Medial OA cancellous bone was significantly thicker and markedly plate-like, but lower in mechanical properties than normal bone. Similar microstructural changes were also observed for the lateral specimens from OA bone, although there had been no sign of cartilage damage. The increased trabecular thickness and density, but relatively decreased connectivity suggest a mechanism of bone remodelling in early OA as a process of filling trabecular cavities. This process leads to a progressive change of trabeculae from rod-like to plate-like, the opposite to that of normal ageing. The decreased mechanical properties of subchondral cancellous bone in OA, which are due to deterioration in architecture and density, indicate poor bone quality.

Aged↗

Parallel plate model for trabecular bone exhibits volume fraction-dependent bias.

Unbiased stereological methods were used in conjunction with microcomputed tomographic (micro-CT) scans of human and animal bone to investigate errors created when the parallel plate model was used to calculate morphometric parameters. Bone samples were obtained from the human proximal tibia, canine distal femur, rat tail, and pig spine and scanned in a micro-CT scanner. Trabecular thickness, trabecular spacing, and trabecular number were calculated using the parallel plate model. Direct thickness, and spacing and connectivity density were calculated using unbiased three-dimensional methods. Both thickness and spacing calculated using the plate model were well correlated to the direct three-dimensional measures (r(2) = 0. 77-0.92). The correlation between trabecular number and connectivity density varied greatly (r(2) = 0.41-0.94). Whereas trabecular thickness was consistently underestimated using the plate model, trabecular spacing was underestimated at low volume fractions and overestimated at high volume fractions. Use of the plate model resulted in a volume-dependent bias in measures of thickness and spacing (p < 0.001). This was a result of the fact that samples of low volume fraction were much more "rod-like" than those of the higher volume fraction. Our findings indicate that the plate model provides biased results, especially when populations with different volume fractions are compared. Therefore, we recommend direct thickness measures when three-dimensional data sets are available.

Adolescent↗

Properties of growing trabecular ovine bone. Part II: architectural and mechanical properties.

We aimed to highlight the relationship between age and the architectural properties of trabecular bone, to outline the patterns in which the variations in these properties take place, and to investigate the influence of the architecture on the mechanical properties of trabecular bone in growing animals. We studied 30 lambs in three age groups and 20 sheep in two age groups. Cubes of subchondral bone were cut from the proximal tibia according to a standardised protocol. They were serially sectioned and their architectural properties were determined. Similar cubes were obtained from the identical anatomical position of the contralateral tibia and their compressive mechanical properties measured. The values obtained from the skeletally immature and mature individuals were compared. Multiple regression analyses were performed between the architectural and the mechanical properties. The bone volume fraction, the mean trabecular volume, the architectural and the mechanical anisotropy, the elastic modulus, the bone strength, the energy absorption to failure, and the elastic energy correlated positively with increasing age whereas the connectivity density, the bone surface density, the ultimate strain, the absorption of viscoelastic energy and the relative loss of energy correlated inversely. The values of all variables were significantly different in the skeletally mature and immature groups. We determined the patterns in which the variations took place. The bone volume fraction of the trabecular bone tissue was found to be the major predictor of its compressive mechanical properties. Together with the mean trabecular volume and the bone surface density, it explained 81% of the variations in the compressive elastic modulus of specimens obtained from the contralateral tibiae.

Age Factors↗

Accuracy of cancellous bone volume fraction measured by micro-CT scanning.

Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner supplied algorithm (method I). A significant deviation of volume fraction from method I was found: both the y-intercept and the slope of the regression line were significantly different from those of the Archimedes-based volume fraction (p < 0.001). New individual thresholds were determined based on a calibration of volume fraction to the Archimedes-based volume fractions (method II). The mean thresholds of the two methods were applied to segment 20 randomly selected specimens. The results showed that volume fraction using the mean threshold of method I was underestimated by 4% (p = 0.001), whereas the mean threshold of method II yielded accurate values. The precision of the measurement was excellent. Our data show that care must be taken when applying thresholds in generating 3-D data, and that a fixed threshold may be used to obtain reliable volume fraction data. This fixed threshold may be determined from the Archimedes-based volume fraction of a subgroup of specimens. The threshold may vary between different materials, and so it should be determined whenever a study series is performed.

Adolescent↗

The role of an effective isotropic tissue modulus in the elastic properties of cancellous bone.

Conceptually, the elastic characteristics of cancellous bone could be predicted directly from the trabecular morphology--or architecture--and by the elastic properties of the tissue itself. Although hardly any experimental evidence exists, it is often implicitly assumed that tissue anisotropy has a negligible effect on the apparent elastic properties of cancellous bone. The question addressed in this paper is whether this is actually true. If it is, then micromechanical finite element analysis (micro-FEA) models, representing trabecular architecture, using an 'effective isotropic tissue modulus' should be able to predict apparent elastic properties of cancellous bone. To test this, accurate multi-axial compressive mechanical tests of 29 whale bone specimens were simulated with specimen-specific micro-FEA computer models built from true three-dimensional reconstructions. By scaling the micro-FEA predictions by a constant tissue modulus, 92% of the variation of Young's moduli determined experimentally could be explained. The correlation even increased to 95% when the micro-FEA moduli were scaled to the isotropic tissue moduli of individual specimens. Excellent agreement was also found in the elastic symmetry axes and anisotropy ratios. The prediction of Poisson's ratios was somewhat less precise at 85% correlation. The results support the hypothesis; for practical purposes, the concept of an 'effective isotropic tissue modulus' concept is a viable one. They also suggest that the value of such a modulus for individual cases might be inferred from the average tissue density, hence the degree of mineralization. Future studies must clarify how specific the tissue modulus should be for different types of bone if adequate predictions of elastic behavior are to be made in this way.

Animals↗

Connectivity and the elastic properties of cancellous bone.

This study addresses the possible significance of trabecular connectivity for the mechanical quality of cancellous bone. A total of 141 cubic trabecular bone specimens collected from autopsy material from 56 individuals without any known bone or metastatic diseases were used. Age variation was in the range of 14-91 years and a wide range of trabecular architecture was found. Each specimen was three-dimensionally reconstructed with a voxel size of either 20 or 25 microm. Using the detailed three-dimensional reconstructions as input for microstructural finite-element models, the complete elastic properties of the trabecular architecture were obtained and maximum and mean stiffness could be calculated. Volume fraction and true three-dimensional architectural measurements of connectivity density and surface density were determined. Connectivity density was determined in an unbiased manner by the Euler number, which is a topological property. Using multiple regression analysis it was found that volume fraction explained by far the greatest part (84%-94%) of the variation in both mean and maximum stiffness. When connectivity density and surface density were included, the correlations increased marginally to 89%-95%. Noticeably negative regression coefficients were found for connectivity density. The results suggest that, in normal cancellous bone, the connectivity density has very limited value for assessment of elastic properties by morphological variables, but if a relation exists then stiffness decreases with increasing connectivity.

Adolescent↗

Constitutive relationships of fabric, density, and elastic properties in cancellous bone architecture.

The hypothesis that trabecular morphology can predict the elastic properties of cancellous bone has only partly been verified and no predictive analytical model is currently available. Such models are becoming increasingly relevant as the resolution levels of three-dimensional scanning techniques approach the size of trabeculae. This study took advantage of micro-finite-element methods and tested the aforementioned hypothesis in normal cancellous bone material collected at six anatomical locations from 56 individuals. Numerical analysis was based on high-resolution three-dimensional computer reconstructions of cancellous bone specimens from which the complete elastic characteristics and trabecular morphology, represented by three different fabric measures (the mean intercept length and two volume-based ones), were calculated. Each fabric measure was analyzed individually using the tensorial relationships derived by Cowin (Mech Mater 4:137-147; 1985). Models for both stiffness and compliance entries were developed. The models based on stiffness entries could explain 93.4%-95.6% of the variance, whereas those based on compliance entries could explain 89.2%-89.4%. When using the former model, the MIL (mean intercept length measure) performed slightly better than the two volume-based measures, VO (volume orientation) and SVD (star volume distribution), with 23% less remaining variance. The high correlations found strongly support the hypothesis and increase the hope that, on the basis of information on trabecular morphology, it will be possible to obtain considerably better estimates of bone quality in vivo compared with the rough two-dimensional density measurements used today.

Adolescent↗

Relationships between bone morphology and bone elastic properties can be accurately quantified using high-resolution computer reconstructions.

It would be advantageous if the mechanical properties of trabecular bone could be directly inferred from stereomorphometric parameters. For that purpose, apparent density and mean intercept length, as measures of bone mass and directionality (fabric), are commonly correlated with the elastic characteristics of bone samples, as determined in compression tests. However, complete and accurate relationships have not yet been established in this way. This may be due not only to the occurrence of artifacts in both the stereomorphometric and the mechanical assessments but also to an inherent inadequacy of mean intercept length in characterizing the full mechanical significance of bone architecture or nonhomogeneities in trabecular tissue properties not accounted for in stereomorphometry. In this study, we introduce a computer modeling approach allowing these biases to be eliminated. With use of high-resolution three-dimensional computer reconstructions of trabecular bone specimens for stereomorphometry and for microstructural finite element models to simulate mechanical tests, unbiased comparisons become feasible. The purpose was to investigate if accurate and complete relationships can be established in this way. Four different fabric measures were considered: mean intercept length and three volume-based ones. Compliance matrices were calculated from fabric tensors, with use of the mathematical relationship proposed by Cowin for 29 vertebral whale-bone specimens. These were correlated with the compliance constants determined directly from the microstructural finite element model simulation. The nine orthotropic elastic constants of all 29 specimens were well predicted from their stereomorphometric fabric and volume fraction values, with correlation coefficients ranging from R2adj = 0.9934 to 0.9963. When individual compliance components were considered (1/Ei, 1/Gij, or -v[ij]/Ei), correlation coefficients ranged from R2adj = 0.924 to 0.982. All four fabric measures performed equally well. It is concluded that volume fraction and fabric measures correlate highly with the apparent elastic properties of bone samples, provided that anisotropy and nonhomogeneity in the elastic properties of the trabecular tissue itself have negligible effects on the apparent properties. Whether this is true for bone in general remains to be seen, as only a subset was analyzed here. These methods, however, can be valuable in similar assessments of other subsets.

Animals↗

Star length distribution: a volume-based concept for the characterization of structural anisotropy.

Determination and quantification of anisotropy is of great interest in research fields dealing with physical structures or surface textures. In this paper, a volume-based method is presented, which essentially determines the mean object length in a certain direction for a typical point within a structure or texture. The mean object lengths for all orientations together form the so-called star length distribution (SLD). The validity and the accuracy of the SLD method are investigated, and illustrated by applying it to trabecular bone. By using a line sampling algorithm, the relation with other anisotropy measures could be studied analytically. Preliminary tests suggest that with SLD a more exact description of the mechanical properties of porous structures may be obtained than with other anisotropy measures. However, due to possible secondary orientations that become apparent with SLD, a fabric tensor must be of rank higher than two in order to properly describe an orthogonal structure mathematically.

Adolescent↗

Star length distribution: a volume-based concept for the characterization of structural anisotropy.

Determination and quantification of anisotropy is of great interest in research fields dealing with physical structures or surface textures. In this paper, a volume-based method is presented, which essentially determines the mean object length in a certain direction for a typical point within a structure or texture. The mean object lengths for all orientations together form the so-called star length distribution (SLD). The validity and the accuracy of the SLD method are investigated, and illustrated by applying it to trabecular bone. By using a line sampling algorithm, the relation with other anisotropy measures could be studied analytically. Preliminary tests suggest that with SLD a more exact description of the mechanical properties of porous structures may be obtained than with other anisotropy measures. However, due to possible secondary orientations that become apparent with SLD, a fabric tensor must be of rank higher than two in order to properly describe an orthogonal structure mathematically.

Journal Article↗

Structure and function of vertebral trabecular bone.

STUDY DESIGN: A combined morphologic and finite-element study on vertebral trabecular bone. OBJECTIVE: To relate the form and function of vertebral trabecular bone, in an attempt to better understand the mechanical function of a lumbar vertebra. SUMMARY OF BACKGROUND DATA: The architecture of bone is closely related to its mechanical function (Wolff's Law). In the human spine, vertebrae are subjected to a large variety of loads. Yet, these bones show a typical architecture, which means that they carry typical loads. METHODS: Five trabecular bone cubes from specific sites of a lumbar vertebra were 3D-reconstructed for computerized analysis. The architecture of the specimens was quantified by the bone volume fraction and a measure of anisotropy, the mean bone length. A finite element model was used to calculate internal stresses within a homogeneous vertebral body under basic loads. For each load case, bone volume fraction of the specimens was compared with the equivalent von Mises stress, and mean bone length was compared with the principal stress directions. RESULTS: Bone volume fraction poorly related to the von Mises stress in the physiologic load case of axial compression. However, high bone volume fractions exist at locations where multiple load situations occur (e.g., near the pedicles and endplates). Remarkably, these sites also show finer architectures. Comparison of mean bone length with principal stresses revealed that the vertebral trabecular bone architecture particularly, but not entirely, corresponds to the stress field under axial compression. The horizontal struts near the end-plates were found to be due to the function of the healthy intervertebral disc, and facetal joint loads introduce stress components that relate well with the bone structures near the pedicle bases. CONCLUSIONS: The trabecular bone architecture and the vertical orientation of the facet joints suggest that walking may be the main activity that determines the lumbar vertebral bone architecture.

Anatomy, Cross-Sectional↗

Fabric and elastic principal directions of cancellous bone are closely related.

Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much effort has been spent in expressing these relations, but the techniques and variables necessary for this have not been fully identified. It is obvious, however, that some measure of architectural anisotropy (fabric) is needed. Within the last few years, volume-based measures of fabric have been introduced as alternatives to the mean intercept length method, which has some theoretical problems. This paper seeks to answer which of four different fabric measures best predicts finite element calculated mechanical anisotropy directions. Twenty-nine cancellous bone specimens were three-dimensionally reconstructed using the automated serial sectioning technique. A series of large-scale finite-element analyses were performed on each of the three-dimensional reconstructions to calculate the compliance matrix for each specimen, from which the mechanical principal directions were derived. The architectural anisotropy was determined in three-dimensional space for each specimen using mean intercept length (MIL), volume orientation (VO), star volume distribution (SVD) and star length distribution (SLD). Each of the architectural anisotropy results were expressed by a fabric tensor. Architectural main directions were determined from the fabric tensors and compared with the FE-calculated mechanical anisotropy directions. All architectural measures predicted the mechanical main directions rather well, which supports the assumption that mechanical anisotropy directions are aligned with fabric directions. MIL showed a significant, though very small (1.4 degrees), deviation from the primary mechanical direction. VO had difficulty in determining secondary and tertiary mechanical directions; its mean deviation was 8.9 degrees. SVD and SLD provided marginally better predictors of mechanical anisotropy directions than MIL and VO.

Animals↗

Three-dimensional methods for quantification of cancellous bone architecture.

Recent development in three-dimensional (3-D) imaging of cancellous bone has made possible true 3-D quantification of trabecular architecture. This provides a significant improvement of the tools available for studying and understanding the mechanical functions of cancellous bone. This article reviews the different techniques for 3-D imaging, which include serial sectioning, X-ray tomographic methods, and NMR scanning. Basic architectural features of cancellous bone are discussed, and it is argued that connectivity and architectural anisotropy (fabric) are of special interest in mechanics-architecture relations. A full characterization of elastic mechanical properties is, with traditional mechanical testing, virtually impossible, but 3-D reconstruction in combination with newly developed methods for large-scale finite element analysis allow calculations of all elastic properties at the cancellous bone continuum level. Connectivity has traditionally been approached by various 2-D methods, but none of these methods have any known relation to 3-D connectivity. A topological approach allows unbiased quantification of connectivity, and this further allows expressions of the mean size of individual trabeculae, which has previously also been approached by a number of uncertain 2-D methods. Anisotropy may be quantified by fundamentally different methods. The well-known mean intercept length method is an interface-based method, whereas the volume orientation method is representative of volume-based methods. Recent studies indicate that volume-based methods are at least as good as interface-based methods in predicting mechanical anisotropy. Any other architectural property may be quantified from 3-D reconstructions of cancellous bone specimens as long as an explicit definition of the property can be given. This challenges intuitive and vaguely defined architectural properties and forces bone scientists toward 3-D thinking.

Anisotropy↗

Simultaneous measurement of stiffness and energy absorptive properties of articular cartilage and subchondral trabecular bone.

The purpose of this study was to develop a method for simultaneous measurement of the mechanical properties of articular cartilage and underlying trabecular bone. Cylindrical bone-cartilage specimens from human cadaver knees were tested under non-destructive axial compression. The specimens wer mounted in a cage by three screws fixed to the subchondral bone plate to create a reference plane between the cartilage and the bone. Each test was carried out as a single test cycle between a 0.12 MPa (4 N) pre-stress and 0.5 per cent bone strain. Twenty conditioning cycles were performed prior to each test cycle. In order to determine the reproducibility of the test method, the test procedure was repeated after turning the cage through 90 degrees. The specimens were then kept at +5 degrees C for 24 hours, and the procedure was repeated. The normalized stiffness and energy absorptive properties were calculated from each test cycle. No significant difference was found between the results obtained on the first and on the second day. Both days the stiffness of cartilage was significantly larger during the second test, indicating that 20 conditioning cycles may not provide a viscoelastic steady state.

Adult↗

Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture.

A method is presented to find orthotropic elastic symmetries and constants directly from the elastic coefficients in the overall stiffness matrix of trabecular bone test specimens. Contrary to earlier developed techniques, this method does not require pure orthotropic behavior or additional fabric measurements. The method uses high-resolution computer reconstructions of trabecular bone specimens as input for large-scale FE-analyses to determine all the 21 elastic coefficients in the overall stiffness matrix of the specimen, using a direct mechanics approach. An optimization procedure is then used to find the coordinate transformation that yields the best orthotropic representation of this matrix. The method is illustrated here relative to two trabecular bone specimens. The techniques developed here can be used to obtain a complete characterization of the mechanical properties of trabecular architecture. With the development of in vivo reconstruction techniques, even in vivo measurements will be possible.

Algorithms↗

Identification of oestrogen receptors and oestrogen receptor mRNA in human adipose tissue.

The distribution of adipose tissue has a major impact on the morbidity and mortality associated with obesity. Furthermore, the distribution of adipose tissue seems to be regulated by sex hormones. Controversy exists over whether the effects of sex hormones (oestrogen and testosterone) on human adipose tissue are an indirect or a direct effect as contradictory results have been obtained when investigating the existence of these receptors in human adipose tissue. In the present study the authors reinvestigated the possible existence of oestrogen receptors (ERs) in human adipose tissue. Human adipocytes from both genders were found to contain specific oestrogen binding sites determined by ligand-binding techniques. The binding protein had a molecular weight of 65 kD (which is similar to that of the ER found elsewhere) and it was found that adipocytes contained mRNA encoding the ER. Moreover, human preadipocytes had no oestrogen-binding capacity and did not possess mRNA encoding the ER. Finally, the authors detected regional differences in receptor density. Women had an equal oestrogen-binding capacity in adipose tissue from the subcutaneous abdominal and the visceral depot, whereas men had twice as high oestrogen-binding capacity in subcutaneous adipose tissue compared with adipose tissue in the visceral fat depot. These findings indicate that mature human adipocytes possess ERs and thus, might be an oestrogen-responsive tissue and that oestrogen may be acting directly in mature adipocytes via its specific receptor. Human preadipocytes, however, seemed not to be an oestrogen-responsive tissue. Finally, preliminary data suggest that there might be differences in ER densities in different fat depots.

Abdomen↗

A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models.

The apparent mechanical behavior of trabecular bone depends on properties at the tissue or trabecular level. Many investigators have attempted to determine trabecular tissue properties and loading. However, accuracy and applicability of all methods reported are limited. The small size of the trabeculae and a possible size effect are complicating factors when using traditional testing methods on single trabeculae. Other methods reported, using models that describe the trabecular structure, are of limited value because they consider bone as a repetitive structure in order to describe a reasonably large region of bone. The present study introduces a new finite-element method strategy that enables analysis of reasonably large regions of trabecular bone in full detail. The method uses three-dimensional serial reconstruction techniques to construct a large-scale FE model, by directly converting voxels to elements. A 5 mm cube of trabecular bone was modeled in this way, resulting in a FE model that consists of 296,679 elements. Special strategies were developed to solve the set of equations that results from the FE approach. Using this model in combination with experimental apparent data taken from the literature, the upper and lower boundaries for the tissue modulus were calculated to be 10.1 and 2.23 GPa, respectively. From the local stress and strain distributions it was concluded that the deformation mode of the trabeculae in the present cube was predominantly in bending. It was concluded that the method developed offers new perspectives for the study of trabecular bone.

Algorithms↗