Search PubMed⌕ Search

Biomedical subjects

A Namiki

Publications and source records attributed to A Namiki.

At least 19 recordsLinked to original sources

Immunohistochemical analysis of acid-sensing ion channel 2 expression in rat dorsal root ganglion and effects of axotomy.

Several studies have suggested that acid-sensing ion channel 2 (ASIC2) plays a role in mechanoperception and acid sensing in the peripheral nervous system. We examined the expression and distribution of ASIC2 in the rat dorsal root ganglion, the co-localization of ASIC2 with tropomyosin-related kinase (trk) receptors, and the effects of axotomy on ASIC2 expression. ASIC2 immunoreactivity was observed in both neurons and satellite cells. ASIC2-positive neurons accounted for 16.5 +/- 2.4% of the total neurons in normal dorsal root ganglion. Most ASIC2-positive neurons were medium-to-large neurons and were labeled with neurofilament 200 kD (NF200). Within these neurons, ASIC2 was not evenly distributed throughout the cytoplasm, but rather was accumulated prominently in the cytoplasm adjacent to the axon hillock and axonal process. We next examined the co-localization of ASIC2 with trk receptors. trkA was expressed in few ASIC2-positive neurons, and trkB and trkC were observed in 85.2% and 53.4% of ASIC2-positive neurons, respectively, while only 6.9% of ASIC2-positive neurons were co-localized with trkC alone. Peripheral axotomy markedly reduced ASIC2 expression in the axotomized dorsal root ganglion neurons. On the other hand, intense ASIC2 staining was observed in satellite cells. These results show that ASIC2 is expressed in the distinct neurochemical population of sensory neurons as well as satellite cells, and that peripheral axotomy induced marked reductions in ASIC2 in neurons.

Acid Sensing Ion Channels↗

Effects of thiopental on bispectral index and heart rate variability.

BACKGROUND AND OBJECTIVE: Thiopental has been reported to reduce sympathetic tone, however, it is not clear whether change in heart rate variability is associated with depth of anaesthesia. The purpose of the present study was to evaluate changes in heart rate variability at different depths of hypnosis during induction of anaesthesia with thiopental. METHODS: We studied 17 ASA I patients scheduled for minor surgery. The depth of hypnosis was monitored by the BIS. Spectral analysis of heart rate variability using a maximum entropy method resulted in a characteristic power spectrum with two main regions, a high frequency and a low frequency. Haemodynamics, entropy, low frequency, high frequency and low frequency/high frequency were monitored in an awake state and after the induction of anaesthesia. RESULTS: Heart rate increased in a BIS-dependent manner, whereas blood pressure showed no significant changes during the study period. High frequency, entropy and low frequency decreased with a reduction in the BIS value. Low frequency/high frequency showed no significant change during the study period. CONCLUSIONS: Induction of anaesthesia with thiopental increased heart rate and decreased high frequency, entropy and low frequency in a BIS-dependent manner, indicating that thiopental reduces cardiac parasympathetic tone depending on the depth of hypnosis.

Adult↗

Angular distributions of H-induced HD and D2 desorptions from the Si(100) surfaces.

We measured angular distributions of HD and D2 molecules desorbed via the reactions H+DSi(100)-->HD [abstraction (ABS)] and H+DSi(100)-->D2 [adsorption-induced-desorption (AID)], respectively. It was found that the angular distribution of HD molecules desorbed along ABS is broader than that of D2 molecules desorbed along AID, i.e., the former could be fit with cos(2.0+/-0.2) theta, while the latter with cos(5.0+/-0.5) theta. This difference of the angular distributions between the two reaction paths suggests that their dynamic mechanisms are different. The observed cos2 theta distribution for the ABS reaction was reproduced by the classical trajectory calculations over the London-Eyring-Polanyi-Sato potential-energy surfaces. The simulation suggests that the HD desorption along the ABS path takes place along the direction of Si-D bonds, but the apparent angular distribution is comprised of multiple components reflecting the different orientations of D-occupied Si dimers in the (2 x 1) and (1 x 2) double domain structures.

Journal Article↗

Desorption dynamics of deuterium molecules from the Si(100)-(3x1) dideuteride surface.

We measured polar angle (theta)-resolved time-of-flight spectra of D2 molecules desorbing from the Si(100)-(3x1) dideuteride surface. The desorbing D2 molecules exhibit a considerable translational heating with mean desorption kinetic energies of approximately 0.25 eV, which is mostly independent of the desorption angles for 0 degrees<or=theta<or=30 degrees. The observed desorption dynamics of deuterium was discussed along the principle of detailed balance to predict their adsorption dynamics onto the monohydride Si surface.

Journal Article↗

Performance of three systems for warming intravenous fluids at different flow rates.

This study compared the intravenous fluid warming capabilities of three systems at different flow rates. The devices studied were a water-bath warmer, a dry-heat plate warmer, and an intravenous fluid tube warmer Ambient temperature was controlled at 22 degrees to 24 degrees C. Normal saline (0.9% NaCl) at either room temperature (21 degrees to 23 degrees C) or at ice-cold temperature (3 degrees to 5 degrees C) was administered through each device at a range of flow rates (2 to 100 ml/min). To mimic clinical conditions, the temperature of the fluid was measured with thermocouples at the end of a one metre tube connected to the outflow of the warmer for the first two devices and at the end of the 1.2 m warming tubing for the intravenous fluid tube warmer The temperature of fluid delivered by the water bath warmer increased as the flow rate was increased up to 15 to 20 ml/min but decreased with greater flow rates. The temperature of the fluid delivered by the dry-heat plate warmer significantly increased as the flow rate was increased within the range tested (due to decreased cooling after leaving the device at higher flow rates). The temperature of fluid delivered by the intravenous fluid tube warmer did not depend on the flow rate up to 20 ml/min but significantly and fluid temperature-dependently decreased at higher flow rates (>30 ml/min). Under the conditions of our testing, the dry heat plate warmer delivered the highest temperature fluid at high flow rates.

Anesthetics, Intravenous↗

Endothelin-1 enhances capsaicin-evoked intracellular Ca2+ response via activation of endothelin a receptor in a protein kinase Cepsilon-dependent manner in dorsal root ganglion neurons.

Increasing evidence indicates that endothelin-1 has a role for peripheral nociceptive signaling in animals and humans. However, the mechanisms of the nociceptive effects of endothelin-1 have not been fully understood. The current study investigated the effects of endothelin-1 on the capsaicin-evoked intracellular Ca2+ response of cultured adult mice dorsal root ganglion neurons. Dorsal root ganglia were harvested from adult male C57B6N mice and were cultured. With a digital image analysis system, we detected the [Ca2+]i image of cultured dorsal root ganglion cells after loading with Fura-2 acetoxymethyl. In addition, co-localization of protein kinase Cepsilon with transient receptor potential V1 and the translocation of protein kinase Cepsilon were investigated using immunohistochemical methods. Endothelin-1 (10 nM) enhanced an increase in [Ca2+]i by capsaicin (10 nM) from 87.6+/-11.6 nM to 414.8+/-62.3 nM (71 of 156 neurons). The inhibition of endothelin A receptor (BQ-123) significantly suppressed the enhancing effect of endothelin-1. In addition, a nonselective protein kinase C inhibitor (bisindolylmaleimide I) significantly suppressed the enhancing effect of endothelin-1. A myristoyl-tagged membrane-permeant-protein kinase Cepsilon V1-2 inhibitory peptide also significantly suppressed the enhancing effect of endothelin-1. In the immunocytochemical study, protein kinase Cepsilon immunoreactivity was found in most of transient receptor potential V1-positive neurons. After endothelin-1 application, protein kinase Cepsilon immunoreactivity was observed to be translocated from the cytosol to the cell membrane in transient receptor potential V1-positive neurons. Our results indicate that endothelin-1 enhances the response of dorsal root ganglion neurons to capsaicin in a protein kinase Cepsilon-dependent manner. Our findings may lead to a new strategy to treat pain associated with endothelin-1.

Algorithms↗

Coverage dependent desorption dynamics of deuterium on Si(100) surfaces: interpretation with a diffusion-promoted desorption model.

We studied coverage dependence of time-of-flight (TOF) spectra of D2 molecules thermally desorbed from the D/Si(100) surface. The mean translational energies Et of desorbed D2 molecules were found to increase from 0.20+/-0.05 eV to 0.40+/-0.04 eV as the desorption coverage window was decreased from 1.0 ML> or =thetaD> or =0.9 ML to 0.2 ML> or =thetaD> or =0 ML, being consistent with the kinetics switch predicted in the interdimer mechanism. The measured TOF spectra were deconvoluted into 2H, 3H, and 4H components by a curve fitting method along the principle of detailed balance. As a result, it turned out that the desorption kinetics changes from the 4H to the 3H situation at high coverage above thetaD=0.9 ML, while the 2H desorption is dominant for a quite wide coverage region up to thetaD=0.8 ML. A dynamic desorption mechanism by which the desorption is promoted by D-atom diffusion to dangling bonds was proposed.

Journal Article↗

Intermittent pneumatic foot compression can activate blood fibrinolysis without changes in blood coagulability and platelet activation.

BACKGROUND: Intermittent pneumatic foot compression (IPC) is a useful technique for prophylaxis of peri-operative venous thromboembolism. The aim of this study was to determine the effect of IPC on blood coagulation/fibrinolysis and platelet function using a blood viscometer (Sonoclot) and a platelet aggregation monitor (WBA analyzer(TM)), respectively. Using the same blood samples, serum levels of tissue-type plasminogen activator (t-PA), thrombomodulin (TM) and activated protein C (APC) were also measured. METHODS: The soles and legs of each subject (n = 8) were compressed for 3 s (130 mmHg) at a 0.3-Hz interval using an IPC device. Parameters were measured 2 min before and at the end of 60-min compression. RESULTS: Parameters of the Sonoclot time-to-peak were shortened and clot retraction rate was increased significantly by IPC, whereas the other parameters did not change. These results indicate that IPC can activate blood fibrinolysis but not coagulability. A parameter of the WBA analyzer PATI (platelet aggregatory threshold index) did not change, indicating that IPC cannot activate platelet function per se. The concentration of t-PA decreased slightly but significantly. A decrease in the concentration of t-PA can lead to activation of fibrinolysis. Other humoral parameters did not change, indicating that IPC has no effect on endothelial function. Although neither blood coagulability nor platelet function were affected by IPC, fibrinolytic activity increased slightly, probably by activation of t-PA function. CONCLUSION: IPC is useful for prophylaxis for thromboembolism by activation of blood fibrinolysis as well as inhibition of blood stasis.

Activated Protein C Resistance↗

Comparative study between propofol in a long-chain triglyceride and propofol in a medium/long-chain triglyceride during sedation with target-controlled infusion.

This study was performed to compare the pharmacological characteristics of propofol in an emulsion of both medium- and long-chain triglycerides (MCT/LCT) with those of propofol in an LCT emulsion, by measuring the sedative level and the plasma concentration of propofol during sedation using a target-controlled infusion (TCI) technique. Forty ASA 1 or 2 adult patients who required spinal anaesthesia for surgery were enrolled in this study. The patients were divided into two groups: a propofol LCT group (n = 20) and a propofol MCT/LCT group (n = 20). Propofol was injected intravenously at target blood concentrations of 2.0, 3.0 and 4.0 microg x ml(-1). The bispectral (BIS) index was recorded, and arterial blood was drawn to measure the actual plasma concentrations of propofol at each predicted concentration. Propofol was assayed by high-performance liquid chromatography. Propofol MCT/LCT was associated with significantly less pain than propofol LCT (P < 0.05). There were no significant differences between the two groups in BIS index or in plasma concentration of propofol at each predicted concentration. Computer-generated TCI of propofol MCT/LCT during sedation is comparable with that of propofol LCT with respect to pharmacokinetics and pharmacodynamics. The formulation of MCT/LCT has a beneficial effect with respect to less pain on injection.

Adult↗

Modulated hydrogen beam study of adsorption-induced desorption of deuterium from Si(100)-3x1:D surfaces.

We have studied the kinetic mechanism of the adsorption-induced-desorption (AID) reaction, H+D/Si(100) --> D2. Using a modulated atomic hydrogen beam, two different types of AID reaction are revealed: one is the fast AID reaction occurring only at the beam on-cycles and the other the slow AID reaction occurring even at the beam off-cycles. Both the fast and slow AID reactions show the different dependence on surface temperature Ts, suggesting that their kinetic mechanisms are different. The fast AID reaction overwhelms the slow one in the desorption yield for 300 K < or = Ts < or = 650 K. It proceeds along a first-order kinetics with respect to the incident H flux. Based on the experimental results, both two AID reactions are suggested to occur only on the 3x1 dihydride phase accumulated during surface exposure to H atoms. Possible mechanisms for the AID reactions are discussed.

Journal Article↗

Recovery characteristics and post-operative delirium after long-duration laparoscope-assisted surgery in elderly patients: propofol-based vs. sevoflurane-based anesthesia.

BACKGROUND: Post-operative mental dysfunction may be an important problem in elderly patients. This study was designed to compare the effects of propofol and sevoflurane anesthesia on recovery characteristics and the incidence of post-operative delirium (POD) in long-duration laparoscopic surgery for elderly patients. METHODS: Fifty ASA physical status I-II patients over the age of 65 scheduled for laparoscopic surgery lasting 3 h or more randomly received propofol (group P, n = 25) or sevoflurane (group S, n = 25) for both induction and maintenance of general anesthesia. Both groups were combined with continuous perioperative epidural analgesia. The level of primary anesthetics was adjusted to maintain changes in mean arterial pressure within 20% of the pre-anesthetic values. The emergence times from anesthesia (eye opening, extubation, response to command, and orientation) were recorded, and the occurrence of POD was assessed by the delirium rating scale (DRS) during the first 3 days after surgery. All patients received oxygen and continuous epidural analgesia postoperatively. RESULTS: Immediate emergence, i.e. eye opening and extubation was significantly faster after sevoflurane (P < 0.05). There was no significant difference between the incidences of POD in the two groups during the first 3 days after surgery. The scores for DRS on day 2 and 3 after surgery, however, were significantly higher in group P than in group S (P < 0.01). CONCLUSION: Sevoflurane may be preferable to propofol for general anesthesia in combination with epidural analgesia with respect to less effect on mental function during the early postoperative period for long-duration laparoscopic surgery in elderly patients.

Aged↗

Left ventricular mechanical performance in elderly patients after induction of anaesthesia. A comparison of inhalational induction with sevoflurane and intravenous induction with fentanyl and propofol.

We investigated changes in left ventricular mechanical performance in 40 patients aged > 70 years in whom anaesthesia had been induced with sevoflurane or with fentanyl and propofol. The ratio of ventricular contractility to arterial properties, which reflects left ventricular performance, was estimated from the ratio of ventricular end-systolic elastance to effective arterial elastance. This ratio decreased after induction in both groups, the magnitude of the decrease being significantly greater in the fentanyl/propofol group than in the sevoflurane group. Decreases in mean arterial pressure after induction of anaesthesia in the two groups were similar, whereas the magnitude of the decrease in heart rate in the sevoflurane group was greater than that in the fentanyl/propofol group. Sevoflurane may therefore be preferable to fentanyl and propofol for induction of anaesthesia in elderly patients because of its lesser effect on left ventricular performance.

Aged↗

The type of carbon dioxide absorbent has no relation to the concentration of carbon monoxide in the breathing circuit during low-flow isoflurane anaesthesia in smoking and non-smoking subjects.

The present study was designed to investigate the concentrations of carbon monoxide (CO) in the anaesthetic circuit and of arterial carboxyhaemoglobin (COHb) during low-flow isoflurane anaesthesia in smoking and non-smoking subjects using three kinds of cardon dioxide (CO2) absorbent. Thirty smoking and 30 non-smoking subjects were selected for this study, and these two groups were each divided into three groups according to the type of CO2 absorbent used (Wakolime A, Drägersorb Free, and Amsorb). Anaesthesia was maintained with 1.0% isoflurane and nitrous oxide (1. 0 l min(-1))/oxygen (1.0 l min(-1)). Concentrations of CO in the inspired breathing circuit and concentrations of arterial COHb were measured at 0, 1, 2, 3, and 4 hours after exposure to isoflurane. In the smoking groups there were no significant differences in CO concentrations in the circuit between the groups and the CO concentrations did not change significantly during the study period. There were also no significant differences in the arterial COHb values between the groups and the COHb concentrations remained constant. There was a significant linear correlation between the concentrations of CO and COHb (r=0.86, n =30, P<0.001). In the non-smoking groups all of the parameters remained constant at low levels that were independent of the type of CO2 absorbents tested. The major source for increased intraoperative CO exposure is related to the patient's smoking status, and the type of CO2 absorbent used has no relation to an increase in CO concentration in the breathing circuit.

Absorption↗

Reductions in levels of bacterial superantigens/cannabinoids by plasma exchange in a patient with severe toxic shock syndrome.

Toxic shock syndrome is a rare but potentially fatal toxin-mediated febrile illness. We report a case of toxic shock syndrome complicated by life-threatening organ dysfunction with high toxin-1 and staphylococcus enterotoxin type A levels that were successfully reduced by early introduction of plasma exchanges. The report shows the time course of the concentrations of anandamide and 2-arachidonyl glyceride and confirms that early introduction of plasma exchange can result in a rapid reduction of circulating toxins and mediators in the treatment of life-threatening multiple organ dysfunction.

Adolescent↗

Pneumocephalus following an epidural blood patch.

Pneumocephalus is a rare complication of epidural block. We report a case of pneumocephalus complicating an epidural blood patch performed 3 days after unintentional dural puncture. Pneumocephalus may occur during an epidural blood patch procedure, even if the epidural needle tip is within the epidural space.

Aged↗

Severe paradoxical intracranial embolism and pulmonary emboli during hip hemiarthroplasty.

Both paradoxical intracranial embolism, an intracranial arterial embolism caused by venous embolic material that has passed through a right-to-left shunt, and pulmonary arterial embolism are life-threatening complications of joint arthroplasty. We report a case of severe paradoxical intracranial embolism and pulmonary embolism that occurred during hip hemiarthroplasty.

Aged↗

Translational heating of D(2) molecules thermally desorbed from Si(100) and Ge(100) surfaces.

The translational energies of D(2) molecules thermally desorbed from the Si(100) and Ge(100) surfaces under a heating rate of 6 K/s have been measured. In contrast to the previous laser desorption study, results show a considerable translational heating; the observed translational temperature is about 3 times higher than the desorption temperature for both surfaces. This fact indicates that energy barriers for adsorption are present even in the desorption pathway. Detailed balance is applicable to the adsorption and desorption dynamics of hydrogen on the Si(100) surface.

Journal Article↗