Search PubMed⌕ Search

Biomedical subjects

A Mehrabi

Publications and source records attributed to A Mehrabi.

At least 37 records · Page 2Linked to original sources

["Multimedia symposium wares". An enrichment of medical and graduate education?].

The continual development of the internet has supported the spread of surgical knowledge by electronic means. High quality products have to be offered from a software as well as a contents point of view. The question as to whether these new media and their contents have a real value for efficient and motivating use in medical education needed to be answered by first assessing a quality profile for the development of surgical educational modules which were then evaluated on the basis of so-called "symposia ware". First, the reactions and opinions of physicians at 47 universities were assessed by a standardized questionnaire concerning their demands on multimedia teaching/learning modules. Several different aspects of technique, content, presentation, didactics and background knowledge were analyzed. In a second step, their opinions were evaluated concerning two applications (symposia implemented on CD-ROM as a slideshow with original slides and audio) with surgical and gastroenterological contents by standardized questionnaire. Questions concerning personal background such as educational status and experience with computers, e-mail and the internet on one hand and the CD-ROM itself concerning content, relevance for daily clinical work and continuing medical education as well as the quality of the application on the other hand, were evaluated using marks (1 = best, 6 = worst). A total of 320 physicians participated in the first part of the interview. Of these, 93% were equipped with computers in hospital as well as privately. The Internet was used by 90% of them. The majority declined a full text presentation as well as the application of scroll fields. The participants rather favored the integration of text, pictures, animations and videos. Furthermore, 95% demanded the provision on the internet. Thirty-seven colleagues in their 5th (1-11) year of training were interviewed, and of those, 27 were working in a surgical department and 10 in a medical department. Individual computer knowledge was rated with a median of 3. This revealed that 60% were equipped with computers in hospital as well as at home, the remaining 40% had computers either in hospital or at home. All participants used the internet. In total, 57% had experience with "Symposia ware". The rating of the "Symposia ware" itself was positive. Relevance and applicability of a slideshow for imparting knowledge were rated with a median of 2. This showed that 81% would buy the CD-ROM in principle, and 89% would spent up to 50 EUR. Quality, language, content and user-friendliness were all rated 2. Physicians frequently use computers and the internet. All this indicates a high degree of acceptance of electronic teaching/learning modules in medical education. A uniform structure of contents as well as a platform-independent, web-based presentation is appreciated. To enhance illustration, a picture and video-oriented visualization should be chosen. Overall, "symposia ware" is rated positively. It should cost no more than 50 EUR and it represents a valuable source of information for physicians.

CD-ROM↗

Characterization of renal parenchymal perfusion during experimental infrarenal aortic clamping and declamping with enhanced thermodiffusion electrodes.

Despite multiple previous experimental and clinical investigations, it has not been fully clarified until now whether infrarenal aortic cross-clamping (IRAC) induces a significant disturbance of renal parenchymal perfusion. Most renal cortical flow data collected thus far have been heterogenous because of inherent limitations of available measurement technology. The enhanced thermal diffusion (TD) electrode is a newly developed and previously validated prototype device that allows continuous quantification of parenchymal kidney perfusion after local probe implantation. We monitored renal perfusion during experimental IRAC with TD for the first time, thereby also evaluating the potential applicability of the method in clinical aortic surgery. IRAC (20 min) followed by sudden declamping was performed in pigs under general anesthesia (n = 14). Renal cortical blood flow (RCBF) was continuously quantified by TD, total aortic flow (TABF) and renal artery flow (RABF) were measured by ultrasonic flow probes, and parameters of systemic circulation were determined by Swan-Ganz catheter. Our results showed that kidney perfusion can be continuously quantified using TD electrodes during experimental aortic surgery in a porcine model. IRAC does not lead to a significant impairment of RCBF in young pigs as measured by TD. Renal perfusion appears to be predominantly pressure driven. Consequently, abrubt aortic declamping can bring about prolonged renal ischemia. Transfer of the TD method to RCBF monitoring during clinical aortic surgery appears to be feasible and should be investigated in selected cases.

Animals↗

Endothelin-1 and big-endothelin concentrations are elevated in liver graft tissue during cold storage and reperfusion.

Endothelin (ET) and its precursor big-ET were synchronously analyzed by RIA in liver biopsies and systemic plasma during porcine orthotopic liver transplantation (OLT) before graft harvesting (phase A), after cold storage (phase B), and early (phase C) and late reperfusion (phase D). Tissue and plasma concentrations were correlated with length of survival and reperfusion. Increased tissue ET/big-ET levels were already detected during phase B (ET: 46 +/- 20; big-ET: 245 +/- 119 pg/mg cytosolic protein) and remained elevated in phase C (ET: 49 +/- 16; big-ET: 306 +/- 144 pg/mg) compared to baseline (ET: 32 +/- 13; big-ET: 185 +/- 164 pg/mg; p < 0.05). In phase D, a rapid concentration decline was detected (ET: 36 +/- 26; big-ET: 163 +/- 138 pg/mg). Systemic ET levels were elevated in phase B (3.4 +/- 3.0 pg/ml), C, (2.8 +/- 1.2 pg/ml) and D (2.6 +/- 2.0 pg/ml), compared to baseline (1.7 +/- 1.1 pg/ml; p < 0.05). ET/big-ET kinetics in liver tissue and systemic plasma showed analogous characteristics. Intrahepatic ET accumulation during storage and early reperfusion could be of relevance for harvest-related disturbances of hepatic microcirculation.

Animals↗

Effects of exogenous endothelin-1 application on liver perfusion in native and transplanted porcine livers.

PURPOSE: This study was designed to assess and differentiate the impact of progressivly increasing portal venous endothelin-1 (ET) plasma concentrations on hepatic micro- and macroperfusion of native porcine livers (Group A) and liver grafts after experimental transplantation (Group B). METHODS: A standardized gradual increment in systemic ET plasma concentration (0-58 pg/ml) was induced by continuous ET-1 infusion into the portal vein in both groups (A: n = 10, B: n = 10). Control animals received only saline (n = 5, each group). Hepatic microcirculation (HMC) was quantified by thermodiffusion electrodes, hepatic artery flow (HAF), and portal venous flow (PVF) by Doppler flowmetry. RESULTS: No changes in ET or perfusion parameters were observed in controls. The mean ET level after orthotopic liver transplantation (OLT) in Group B was elevated (baseline: 3.8 +/- 2.4 pg/ml) compared with Group A (2.8 +/- 1.9 pg/ml). With rising ET levels HAF decreased progressively in Group A from 205 +/- 97 (baseline) to 160 +/- 72 ml/min, and in Group B from 161 +/- 87 to 146 +/- 68 ml/min. PVF decreased in Group A from 722 +/- 253 to 370 +/- 198 ml/min, and in Group B from 846 +/- 263 to 417 +/- 203 ml/min. Baseline HMC in Group A was 86 +/- 15 and decreased significantly to 29 +/- 9 ml/100 g/min, and baseline MC in Group B was 90 +/- 22 and decreased to 44 +/- 32 ml/100 g/min. No significant alteration in systemic circulation was noted at the ET concentrations investigated. CONCLUSIONS: Significant impairment of hepatic micro- and macrocirculation was detected after induction of systemic ET levels above 9.4 pg/ml both in native and in transplanted livers. Disturbance of HMC was caused predominantly by reduction of portal venous flow, while the effect of ET on HAF was less pronounced. Characteristics of flow impairment in transplanted and native livers were analogous after short cold ischemic graft storage (6 h).

Animals↗

Intramucosal pH and liver endotoxin clearance during experimental liver transplantation.

The study was designed to assess the gastrointestinal ischaemia and the influence of the specific Kupffer cell toxin gadolinium chloride (GdCl3) on the hepatic and extrahepatic endotoxin [lipopolysaccharide (LPS)] clearance during experimental orthotopic liver transplantation (OLT) in pigs. In eight pig liver transplantations, the donors received 20 mg/kg of GdCl3 24 h before explantation, while controls (n = 8) received normal saline. Gastric and sigmoid intramucosal pH (pHi), LPS and endotoxin-neutralising capacity (ENC) levels were measured in the portal vein and superior vena cava after laparatomy, at the end of the anhepatic phase and 1 h after reperfusion. During the anhepatic phase, the sigmoid pHi decreased significantly from 7.32 +/- 0.02 to 7.29 +/- 0.03 (P < 0.001) and was associated with a substantial increase of portal LPS. Following reperfusion, the systemic LPS concentrations were significantly lower in the pretreated group [39 +/- 23 pg/ml (Control); 14 +/- 7 (GdCl3); P < 0.05] suggesting an improved liver LPS clearance [86% (GdCl3); 58.2% (Control); P < 0.05]. This corresponded to an increased ENC in the pretreated group [118 +/- 52 ENU/ml (GdCl3) vs 81 +/- 45 ENU/ml (Control); P < 0.05]. The anhepatic phase induced splanchnic ischaemia which correlated with portal endotoxaemia. Donor preconditioning with GdCl3 leads to lower systemic LPS concentrations in the recipient and increases ENC values in the early phase after OLT. An improved hepatocellular LPS extraction and/or an activation of the extrahepatic reticulo-endothelial system as a result of GdCl3 treatment is discussed.

Animals↗

Sequential (domino) transplantation of the liver in a transthyretin-50 familial amyloid polyneuropathy. Special reference to cardiological diagnosis and complications.

BACKGROUND: General shortage of cadaveric organs has led to a search for alternative methods to expand the donor pool. Sequential (domino) transplantation is yet another attempt to compensate for the declining consent to organ donation. PATIENTS AND METHODS: To qualify for a domino liver transplantation, the following preconditions must be fulfilled: (1) extrahepatic disease must exist, (2) liver must be fully functional, and (3) the genetic defect in the host should recur within a sufficient latency period. Familial amyloid polyneuropathy (FAP) is an autosomal dominant disease which involves a genetic defect for transthyretin (TTR), which is predominantly produced in the liver. RESULTS: In this report, we describe a rare case of a FAP TTR-50 variant undergoing domino liver transplantation. Since myocardial symptoms precede peripheral polyneuropathy, special emphasis should be placed on arrhythmias and the restrictive cardiomyopathy necessitating a veno-venous bypass or a cardiac pacemaker in order to improve cardiac contractility. The type of anastomosis of the suprahepatic inferior vena cava and possible alternatives are discussed. CONCLUSION: Despite ethical problems, the advantages of the domino procedure are obvious: (1) expansion of the donor pool, (2) ability to use living donors, and (3) presence of very short ischemic time and thus excellent liver function. Due to the kinetics of TTR production and deposition, donors and recipients of FAP livers should be followed up using an extensive neurological and cardiological protocol.

Adult↗

A new way for surgical education--development and evaluation of a computer-based training module.

Computer-based training (CBT) programs teach the material of a specific field and at the same time offer various ways of objectively assessing the knowledge gained. The interactive use of multi-media components such as text, graphics, animation, sound, digital slide shows, and videos as well as quizzes can theoretically facilitate the learning process. The aim of this study was the development and evaluation of a CBT-program by surgeons for student training. Using SuperCard, a teaching module for Distal Radius Fracture (DRF) was developed, which contains detailed clinical information. Video clips and vivid animations combine theoretical knowledge with practical experience. Fourth-year medical students (n = 103) were tested after using the module for 90 min. Other students (n = 47) served as the control group. In a 90 min lecture, DRF was discussed. CBT gained in all evaluated criteria (distinctiveness, detailed description, presentation of materials, structure, motivation for learning, time saved learning and memory retention) 15-20% better scores than the lecture. Although 82% of the students stated that their experience with computers was limited or insufficient, 100% found the use of CBT systems useful in student teaching. Most of them suggested the use of such programs as a method of exam preparation/self study (90%) or as a supplement to a lecture (40%). Based on these evaluations, CBT modules are an appropriate future teaching and learning system that is well accepted. In conclusion, the results of this study show that CBT-programs could be a valuable supplement to medical education. In addition, further development of CBT-programs and their use as information systems for surgical residency programs at universities can be suggested.

Adult↗

Assessment of hepatic perfusion in pigs by pharmacokinetic analysis of dynamic MR images.

The purpose of this study was to evaluate a new method based on magnetic resonance imaging for the characterization of hepatic perfusion. In nine pigs dynamic MRI was performed before and after partial occlusion of the portal vein. The pharmacokinetic analysis of the contrast enhancement resulted in a set of parameters (amplitude, A; perfusion rate, kp; elimination rate, kappa(e1); lag time, t(lag)) of which kp was expected to correlate with hepatic perfusion. Reference measurements were done with ultrasound flow-meters and with a thermal diffusion probe (TDP). MR perfusion rate kp significantly dropped under partial portal vein occlusion from an average of 11.3 to 4.9 min(-1) (P < 0.001), while the difference in amplitude A was not significant. The correlation between kp and the TDP measurement was r = 0.89 (P < 0.001). Pharmacokinetic analysis of MRI contrast enhancement provides a non-invasive assessment of hepatic perfusion.

Animals↗

[The VCS clip--experimental experiences with a new vascular suture stapling device].

Despite improvements in technique and suture material, vascular anastomosis is still associated with a significant rate of early (stenosis, thrombosis) and late (intimal hyperplasia) complications. Although automatic mechanical staplers were practical und comparatively safe to use, they did not play a major role in vascular surgery, probably due to the complexity and difficult handling. In an experimental study with the VCS clip system, we found a significant improvement in performing a hepatic artery anastomosis [9.2 +/- 1.5 min (VCS) vs 20.6 +/- 2.7 min (suture), P < 0.001], early patency and flow rate [150 +/- 29.1 ml/min (1.0 h)-->79.9 +/- 24.0 ml/min (24 h) (suture) vs 186 +/- 45 ml/min (1.0 h)-->162 +/- 48 ml/min (VCS), P < 0.005]. Besides easy handling, the VCS clip system allows for a fast, standardized vascular anastomosis without intimal penetration.

Anastomosis, Surgical↗

Development of a computer based training program for liver transplantation.

The existence and future of every scientific area is directly and indirectly dependent on advanced education in that area and the quality of the work performed. Our aim in developing this program was to improve advanced education in liver transplant surgery and to ensure the quality of the work performed by every surgeon operating in this field. We developed a module that contains extensive information on the pathogenesis, symptoms, diagnosis, X-rays and treatment plans as well as operation-videos and case studies on the most common aspects in liver transplantation. This "teachware" is now on CD-ROM and can be installed on every personal computer without special computer knowledge. The expansion and updating of the material is technically facilitated with the help of an authoring tool.

CD-ROM↗