Search PubMed⌕ Search

Biomedical subjects

A M Wilson

Publications and source records attributed to A M Wilson.

At least 37 records · Page 2Linked to original sources

The role of the extrinsic thoracic limb muscles in equine locomotion.

Muscles have two major roles in locomotion: to generate force and to absorb/generate power (do work). Economical force generation is achieved by short-fibred pennate muscle while the maximum power output of a muscle is architecture independent. In this study we tested the hypothesis that there is an anatomical and structural separation between the force-generating anti-gravity muscles and the propulsive (limb/trunk moving) muscles of the equine forelimb. Muscle mass and fascicle length measurements were made on the thoracic limb extrinsic muscles of six fresh horse cadavers. Physiological cross-sectional area and maximum isometric force were then estimated. Maximum power was estimated from muscle volume and published contraction velocity data. The majority of extrinsic forelimb muscles were large with long fascicles arranged in parallel to the long axis of the muscle. Muscles arranged in this way are optimised for doing work. The architecture of serratus ventralis thoracis (SVT) was unique. It had short (48 +/- 17 mm) fascicles, arranged at about 45 degrees to the long axis of the muscle, which would suggest a force-generating, anti-gravity role. The muscle belly of SVT was sandwiched between two broad, thick sheets of aponeurosis. Hence, SVT could make a significant contribution to the overall elastic properties of the thoracic limb.

Animals↗

Functional specialisation of pelvic limb anatomy in horses (Equus caballus).

We provide quantitative anatomical data on the muscle-tendon units of the equine pelvic limb. Specifically, we recorded muscle mass, fascicle length, pennation angle, tendon mass and tendon rest length. Physiological cross sectional area was then determined and maximum isometric force estimated. There was proximal-to-distal reduction in muscle volume and fascicle length. Proximal limb tendons were few and, where present, were relatively short. By contrast, distal limb tendons were numerous and long in comparison to mean muscle fascicle length, increasing potential for elastic energy storage. When compared with published data on thoracic limb muscles, proximal pelvic limb muscles were larger in volume and had shorter fascicles. Distal limb muscle architecture was similar in thoracic and pelvic limbs with the exception of flexor digitorum lateralis (lateral head of the deep digital flexor), the architecture of which was similar to that of the pelvic and thoracic limb superficial digital flexors, suggesting a functional similarity.

Animals↗

Fit to fly: practical challenges in neonatal transfers by air.

Air transport of infants in incubators should be undertaken in a manner that is safe for both staff and infant and satisfies all directives by appropriate regulatory bodies. In Scotland during the last two years, certification of an infant incubator system for use in both rotary and fixed wing aircraft has been accomplished. This is a report of the issues addressed during this project, which will be common to all neonatal transport services intending to develop air transport capability.

Aerospace Medicine↗

A modified Hill muscle model that predicts muscle power output and efficiency during sinusoidal length changes.

The power output of a muscle and its efficiency vary widely under different activation conditions. This is partially due to the complex interaction between the contractile component of a muscle and the serial elasticity. We investigated the relationship between power output and efficiency of muscle by developing a model to predict the power output and efficiency of muscles under varying activation conditions during cyclical length changes. A comparison to experimental data from two different muscle types suggests that the model can effectively predict the time course of force and mechanical energetic output of muscle for a wide range of contraction conditions, particularly during activation of the muscle. With fixed activation properties, discrepancies in the work output between the model and the experimental results were greatest at the faster and slower cycle frequencies than that for which the model was optimised. Further optimisation of the activation properties across each individual cycle frequency examined demonstrated that a change in the relationship between the concentration of the activator (Ca2+) and the activation level could account for these discrepancies. The variation in activation properties with speed provides evidence for the phenomenon of shortening deactivation, whereby at higher speeds of contraction the muscle deactivates at a faster rate. The results of this study demonstrate that predictions about the mechanics and energetics of muscle are possible when sufficient information is known about the specific muscle.

Animals↗

Effects of series elasticity and activation conditions on muscle power output and efficiency.

The activation of a muscle depends on the function that it is performing and on the architectural properties of that muscle; the two are inextricably linked. Activation conditions such as activation timing, duration and amplitude can be varied throughout a cyclical movement (such as locomotion) and the length change of the whole muscle tendon unit (MTU) can also be varied. Architecturally, muscles have a range of fibre lengths, maximum force-producing capabilities and stiffness of the series elastic element (SEE). In the present work we use a model to explore the relationship between power output and efficiency of a muscle across a range of contraction conditions. We have also examined the mechanical and energetic effects of changing muscle architecture within the model. Our results indicate that whilst there are clear optimal conditions for achieving maximum power output and maximum efficiency, the design of the muscle allows high levels of both to be achieved over a range of activation conditions. This range changes with both SEE compliance and the amplitude of the cyclical length change. The results suggest that a compliant SEE allows a muscle to function closer to the maximum of both power output and efficiency. In addition, by varying the amplitude of the activation level, the efficiency can theoretically remain unchanged, whilst the power output can be modulated.

Animals↗

In vivo mechanical properties of the human Achilles tendon during one-legged hopping.

Compliant tendons act as energy stores, which benefit the energetics and power output of a muscle-tendon unit. However the compliance of tendon and the material properties may vary between individuals and hence alter the energy storing capacity of the tendon. We aimed to determine the in vivo Achilles tendon (AT) stress and strain during one-legged hopping and hence the contribution of elastic recoil to mechanical energy changes. We simultaneously measured the length of the Achilles tendon from the muscle-tendon junction to the insertion on the calcaneous and the approximate AT force in ten male participants. The position of the muscle-tendon junction was determined using ultrasound images that were projected into three-dimensional space. Achilles tendon force was measured using inverse dynamics. The results demonstrated that one-legged hopping elicited high tendon strains and that the force-length relationship of the whole tendon is relatively linear, particularly at high strains. The stiffness, elastic modulus and hysteresis varied across the population (inter-quartile range of 145-231 N mm-1, 0.67-1.07 GPa and 17-35%, respectively). These values are within the reported biological range. An average of 38 J of energy was recovered from the elastic recoil of the tendon, which contributes 16% of the total average mechanical work of the hop (254 J). The high strains measured here (average peak strain was 8.3%) and in other studies may be possible due to the complex architecture of the Achilles tendon; however, prolonged hopping may well cause tendon damage. In conclusion, the properties of the elastic Achilles tendon can contribute significantly to the total mechanical work of the body during one-legged hopping; however, individual variation in the properties of the tendon vary the energy storing capacity of this structure.

Achilles Tendon↗

Deep digital flexor tendon force and digital mechanics in normal ponies and ponies with rotation of the distal phalanx as a sequel to laminitis.

REASONS FOR PERFORMING STUDY: Previous studies have implicated tension in the deep digital flexor tendon (DDFT) in the rotation of the distal phalanx (DP) after the breakdown of the dorsal laminae caused by laminitis. Howeveer, once the DP has rotated, the DDFT should become shorter, reducing the force it exerts on the DP. OBJECTIVE: To compare DDFT force and ground reaction forces (GRFs) in normal ponies and ponies with rotation of the DP as a sequel to laminitis. METHODS: Six normal ponies (Group 1) and 6 sound ponies with 6-13 degrees of rotation of the DP in relation to the dorsal hoof wall (Group 2) were assessed at trot using forceplate and motion analysis. The force in the DDFT was calculated by assuming that the extending moment at the distal interphalangeal (DIP) joint resulting from the GRF was equal to the flexing moment created by the force in the DDFT during the stance phase (inverse dynamics). RESULTS: In early stance, the peak DDFT force (mean+/-s.d.) in the normal ponies was 1.92+/-1.63 N/kg. However, in Group 2, the point of zero moment was palmar to the centre of rotation of the DIP joint for the first 40% of stance and hence DDFT force was zero. Force in the DDFT reached a peak of 10.00+/-3.56 N/kg at 60.7+/-5.6% of stance in Group 1 and 6.41+/-1.37 N/kg at 79.2+/-9.6% of stance in Group 2. CONCLUSIONS: DDFT force in Group 2 laminitic ponies was much reduced until late stance, when it neared normal values. POTENTIAL RELEVANCE: Further studies of ponies with rotation of the DP as a sequel to laminitis should assist farriery aimed at reducing the force in the DDFT through the breakover phase of stance to protect damaged dorsal laminae.

Animals↗

Accuracy of non-differential GPS for the determination of speed over ground.

Accurate determination of speed is important in many studies of human and animal locomotion. Some global positioning system (GPS) receivers can data log instantaneous speed. The speed accuracy of these systems is, however, unclear with manufacturers reporting velocity accuracies of 0.1-0.2 ms(-1). This study set out to trial non-differential GPS as a means of determining speed under real-life conditions. A bicycle was ridden around a running track and a custom-made bicycle speedometer was calibrated. Additional experiments were performed around circular tracks of known circumference and along a straight road. Instantaneous speed was determined simultaneously by the custom speedometer and a data logging helmet-mounted GPS receiver. GPS speed was compared to speedometer speed. The effect on speed accuracy of satellite number; changing satellite geometry, achieved through shielding the GPS antenna; speed; horizontal dilution of precision and cyclist position on a straight or a bend, was evaluated. The relative contribution of each variable to overall speed accuracy was determined by ANOVA. The speed determined by the GPS receiver was within 0.2 ms(-1) of the true speed measured for 45% of the values with a further 19% lying within 0.4 ms(-1) (n = 5060). The accuracy of speed determination was preserved even when the positional data were degraded due to poor satellite number or geometry. GPS data loggers are therefore accurate for the determination of speed over-ground in biomechanical and energetic studies performed on relatively straight courses. Errors increase on circular paths, especially those with small radii of curvature, due to a tendency to underestimate speed.

Animals↗

No evidence of sustained myocardial injury following an Ironman distance triathlon.

We aimed to determine whether an Ironman distance triathlon resulted in sustained myocardial injury detected by electrocardiography, biochemical markers or echocardiographic assessment of left ventricular systolic and diastolic function. Electrocardiograms, blood for analysis of creatine kinase (CK) and its MB fraction, cardiac troponin I (cTnI) and echocardiograms were obtained in 15 male athletes prior to and at a mean of 4.7 days after competing in the Australian Ironman Triathlon. Regional wall motion scores, left ventricular ejection fraction (LVEF) and mitral inflow parameters were determined from the echocardiograms by a blinded investigator. Levels of cTnI were undetectable in all athletes and total CK was mildly elevated in 7/15 athletes prior to the event. Baseline wall motion, ejection fraction and diastolic filling were normal in all athletes. CK levels were increased post-race (p < 0.05) with a mean post-race level of 451U/l. Levels of cTnI were undetectable post-race in 14 athletes with a level of 0.9 microg/l recorded in one athlete, although all were within the laboratory's normal range for the assay. Mitral inflow parameters and LVEF did not change post-race and regional wall motion was normal in 14 of 15 athletes. Regional wall motion abnormalities detected in 1 athlete had resolved by 25 days post-race. These findings indicate that ultraendurance exercise does not result in sustained myocardial injury in this group of elite athletes.

Adult↗

The role of the extrinsic thoracic limb muscles in equine locomotion.

Muscles have two major roles in locomotion: to generate force and to absorb/generate power (do work). Economical force generation is achieved by short-fibred pennate muscle while the maximum power output of a muscle is architecture independent. In this study we tested the hypothesis that there is an anatomical and structural separation between the force-generating anti-gravity muscles and the propulsive (limb/trunk moving) muscles of the equine forelimb. Muscle mass and fascicle length measurements were made on the thoracic limb extrinsic muscles of six fresh horse cadavers. Physiological cross-sectional area and maximum isometric force were then estimated. Maximum power was estimated from muscle volume and published contraction velocity data. The majority of extrinsic forelimb muscles were large with long fascicles arranged in parallel to the long axis of the muscle. Muscles arranged in this way are optimised for doing work. The architecture of serratus ventralis thoracis (SVT) was unique. It had short (48 +/- 17 mm) fascicles, arranged at about 45 degrees to the long axis of the muscle, which would suggest a force-generating, anti-gravity role. The muscle belly of SVT was sandwiched between two broad, thick sheets of aponeurosis. Hence, SVT could make a significant contribution to the overall elastic properties of the thoracic limb.

Animals↗

Management of ischaemic heart disease in women of child-bearing age.

Ischaemic heart disease is rare in young women but is expected to increase with increasing average age of child bearing. Diagnosis of myocardial ischaemia in this group is complicated by limited data about maternal and fetal safety of the standard diagnostic tests routinely used in other patients. Management of these patients remains difficult, as many standard treatments, such as beta-blockers and angiotensin converting enzyme inhibitors are pregnancy category C or D, and there is little experience with many of the newer treatments such as coronary artery stenting, clopidogrel and glycoprotein IIb/IIIa inhibitors in pregnancy. An interesting case of a woman, who had an acute myocardial infarction treated with thrombolysis and coronary artery stenting, and who subsequently became pregnant, is reported here, and other published reports regarding the management of coronary artery disease, both acute and chronic, in pregnant women are explored.

Adult↗

Determination of peak vertical ground reaction force from duty factor in the horse (Equus caballus).

Measurement of peak vertical ground reaction force (GRFz) from multiple limbs simultaneously during high-speed, over-ground locomotion would enhance our understanding of the locomotor mechanics of cursorial animals. Here, we evaluate the accuracy of predicting peak GRFz from duty factor (the proportion of the stride for which the limb is in contact with the ground). Foot-mounted uniaxial accelerometers, combined with UHF FM telemetry, are shown to be practical and accurate for the field measurement of stride timing variables, including duty factor. Direct comparison with the force plate produces a mean error of 2.3 ms and 3.5 ms for the timing of foot on and foot off, respectively, across all gaits. Predictions of peak GRFz from duty factor show mean errors (with positive values indicating an overestimate) of 0.8+/-0.04 N kg(-1) (13%; N=42; mean +/- S.E.M.) at walk, -0.3+/-0.06 N kg(-1) (3%; N=75) at trot, -2.3+/-0.27 N kg(-1) (16%; N=18) for the non-lead limb at canter and +2.1+/-0.7 N kg(-1) (19%; N=9) for the lead limb at canter. The substantial over- and underestimate seen at canter, in the lead and non-lead limbs, respectively, is attributed to the different functions performed by the two limbs in the asymmetrical gaits. The difference in load experienced by the lead and non-lead limbs decreased with increasing speed.

Acceleration↗

Relationship of foot conformation and force applied to the navicular bone of sound horses at the trot.

REASONS FOR PERFORMING STUDY: Collapsed heels conformation has been implicated as causing radical biomechanical alterations, predisposing horses to navicular disease. However, the correlation between hoof conformation and the forces exerted on the navicular bone has not been documented. HYPOTHESIS: The angle of the distal phalanx in relation to the ground is correlated to the degree of heel collapse and foot conformation is correlated to the compressive force exerted by the deep digital flexor tendon on the navicular bone. METHODS: Thirty-one shod Irish Draught-cross type horses in routine work and farriery care were trotted over a forceplate, with 3-dimensional (3D) motion analysis system. A lateromedial radiograph of the right fore foot was obtained for each horse, and various measurements taken. Correlation coefficients were determined between hoof conformation measurements and between each of these and the force parameters at the beginning (15%) of stance phase, the middle of stance (50%) and at the beginning of breakover (86% of stance phase). Significance was defined as P<0.05. RESULTS: The force exerted on the navicular bone was negatively correlated (P<0.05) to the angle of the distal phalanx to the ground and to the ratio between heel and toe height. This was attributed to a smaller extending moment at the distal interphalangeal joint. There was not a significant correlation between the angle of the distal phalanx and the degree of heel collapse, and heel collapse was not significantly correlated to any of the force parameters. CONCLUSIONS: Hoof conformation has a marked correlation to the forces applied to the equine foot. Heel collapse, as defined by the change in heel angle in relation to toe angle, appears to be an inaccurate parameter. The forces applied on the foot are well correlated to the changes in the ratio of heel to toe heights and the angles of the distal phalanx. POTENTIAL RELEVANCE: Assessment of hoof conformation should be judged based on these parameters, as they may have clinical significance, whereas parallelism of the heel and toe is of less importance.

Animals↗

Effects of mediator antagonism on mannitol and adenosine monophosphate challenges.

BACKGROUND: Airway hyper-responsiveness (AHR) to indirect stimuli is a useful non-invasive surrogate inflammatory marker in the evaluation of asthma, while histamine and cysteinyl leukotrienes are important inflammatory mediators. OBJECTIVE: To evaluate AHR to indirect bronchoconstrictor stimuli and time taken to recover following single doses of montelukast 10 mg and desloratadine 5 mg in combination, montelukast 10 mg alone and placebo. METHODS: Fifteen mild-to-moderate persistent asthmatics completed a randomized, double-blind, cross-over study. Patients received encapsulated montelukast 10 mg/desloratadine 5 mg combination, montelukast 10 mg alone and placebo, 10-14 h prior to challenge on two separate occasions. The mannitol threshold dose, AMP threshold concentration and recovery times after challenge were measured along with lung function. RESULTS: Compared to placebo, montelukast/desloratadine conferred improvements (P < 0.05) in adenosine monophosphate (AMP) threshold concentration and mannitol threshold dose: a 3.2-fold (95% CI 2.2-4.6) and 2.4-fold (95% CI 1.7-3.3) difference, respectively, while compared to montelukast this amounted to a 2.0-fold (95% CI 1.2-3.4) and 1.5-fold (95% CI 1.1-2.4) improvement, respectively. Montelukast was not significantly different from placebo. Both montelukast/desloratadine and montelukast compared to placebo, shortened recovery following both challenges (P < 0.05): a 27-min (95% CI 17-37) and 29-min (95% CI 20-36) reduction, respectively, for AMP, and a 27-min (95% CI 17-37) and 26-min (95% CI 17-35) reduction, respectively for mannitol. CONCLUSION: The dissociated effects of single doses of montelukast alone but not montelukast/desloratadine combination on AHR and recovery time, highlights the relative roles of histamine in initiating the bronchoconstrictor response and cysteinyl leukotrienes in sustaining it. Similar improvements in AHR and recovery time were observed following both indirect bronchoconstrictor stimuli.

Acetates↗

Are needle-free injections a useful alternative for growth hormone therapy in children? Safety and pharmacokinetics of growth hormone delivered by a new needle-free injection device compared to a fine gauge needle.

The clinical safety, use and pharmacokinetics of a new needle-free device for delivery of growth hormone (GH) were compared with those of conventional needle injection devices. In an open-label, randomized, 4-period crossover study, 18 healthy adults received single subcutaneous injections of Genotropin administered by the Genotropin ZipTip needle-free device and by conventional injection. Bioequivalence was established between the devices. In a separate open-label, randomized, multicenter, 2-period crossover study, pediatric patients underwent 2-weeks Genotropin treatment administered by the Genotropin ZipTip and by a fine-gauge needle device (>95% used the Genotropin Pen). In total, 128/133 patients who were treated completed the study. Genotropin ZipTip was well tolerated and >50% of patients found no difference between the devices for all parameters assessed. After study completion, >20% patients preferred to continue using Genotropin ZipTip. Although statistical analyses demonstrated superiority of the Genotropin Pen versus Genotropin ZipTip for bleeding, pain, soreness, and bruising, Genotropin ZipTip was considered to provide a safe and bioequivalent alternative to needle injection.

Adolescent↗

Circadian variation in biochemical markers of bone cell activity and insulin-like growth factor-I in two-year-old horses.

Studies in humans have found circadian changes to be one of the most important sources of controllable preanalytical variability when evaluating bone cell activity using biochemical markers. It remains unclear whether similar circadian changes influence bone marker concentrations in the horse. The aim of this study was to characterize changes in serum concentrations of three biochemical markers of bone cell activity over a 24-h period in six 2-yr-old Thoroughbred mares, and to determine circadian variability in IGF-I, which regulates bone turnover. Three bone markers were measured in serum: osteocalcin, a marker of bone formation, the carboxy-terminal propeptide of type-I collagen (a marker of bone formation), and the carboxy-terminal telopeptide of type-I collagen (a marker of bone resorption). Data were analyzed using the cosinor technique, which fits a 24-h cycle to each dataset. A significant circadian rhythm was observed for osteocalcin (P = 0.028), with an estimated amplitude of 7.6% of the mean (95% confidence interval 1.3% to 16.3%), and an estimated peak time of 0900. However, the observed rhythm for the carboxy-terminal telopeptide of type-I collagen (amplitude = 7.4%) was not significant (P = 0.067), and there were no significant changes in concentrations of the carboxy-terminal propeptide of type-I collagen over the 24-h study period (P = 0.44). There was a small but significant circadian rhythm for IGF-I (P = 0.04), with an estimated amplitude of 3.4% (95% confidence interval 0.2 to 7.1%) and peak at 1730. Further studies are now required to determine the potential association between circadian changes in IGF-I and osteocalcin in the horse. Although no significant circadian variation was found in concentrations of the car-boxy-terminal propeptide of type-I collagen and the carboxy-terminal telopeptide of type-I collagen, this may in part be a result of the age of the animals that were still skeletally immature. Future studies should aim to determine whether these markers develop a circadian rhythm at a later age when growth is complete. In the meantime, consistency in time of sampling should continue to be considered best practice when measuring biochemical markers of bone turnover in the horse.

Age Factors↗

Effect of foot balance on the intra-articular pressure in the distal interphalangeal joint in vitro.

REASONS FOR PERFORMING STUDY: Increased joint pressure has been implicated in the progression of osteoarthritis. HYPOTHESIS: That intra-articular pressure in the distal interphalangeal joint (DIP) is significantly higher in legs loaded with heel up (HU), low heel (TU), lateral side up (LU) and medial side up (MU) imbalance compared to the balanced position. METHODS: Twelve elbow down limbs were compressed in a hydraulic loading jig and DIP pressure measured. RESULTS: Elevating the heels by 5 degrees significantly increased DIP pressure. After 5 ml of contrast was injected into the joint, heel elevation caused a greater increase in DIP pressure and heel lowering decreased DIP pressure. Silicone rubber castings were taken of 20 DIP whilst under load. The articular contact area was localised on the dorsal aspect in the HU position, palmar aspect in the TU position and towards the elevated side with lateromedial imbalance. CONCLUSIONS: Altered foot orientation, which could result from trimming and shoeing, therefore influences intra-articular pressure in the DIP and the articular contact area. POTENTIAL CLINICAL RELEVANCE: The results support the view that a balanced foot is the ideal and that the elevated heels may be detrimental to long term viability of the DIP joint.

Abattoirs↗